Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Knee ; 34: 259-269, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35077945

RESUMEN

BACKGROUND: The aim was to investigate the correlation of bone tracer uptake (BTU) in SPECT/CT and changes in coronal knee alignment after total knee arthroplasty (TKA). We questioned if undercorrection of preoperative varus alignment leads to a difference in BTU compared to neutral alignment. METHODS: Consecutive 66 patients who received SPECT/CT before and after TKA were retrospectively included. Adjusted mechanical alignment was the alignment target. The alignment of the knee was measured on 3D-CT by selecting standardized landmarks. Maximum (mean ± SD) and relative BTU (ratio to the reference) were recorded using a previously validated localization scheme (p < 0.05). RESULTS: In the native group, 20 knees were aligned (30.3%) in valgus (HKA > 181.5°), 12 (18.2%) in neutral (178.5°-181.5°) and 34 (51.5%) in varus (HKA < 178°). Overall TKA changed the alignment towards neutral. 48.5% remained in the same groups, whereas 50% of native valgus and 33% of varus knees changed to neutral after TKA. In native varus alignment mean BTU was significantly higher in some medial tibial and femoral regions (fem1ia (p = 0.010), fem1ip (p = 0.002), tib1a.mid (p = 0.005), tib1a.tray (p = 0.000), tib1p.tray (p = 0.000)); in native valgus alignment mean BTU was higher in the corresponding lateral tibial and femoral regions (fem2ip (p = 0.001), tib2a.tray (p = 0.011), tib2p.tray (p = 0.002)). After TKA, a significant decrease in femoral and tibial BTU (femoral preoperative BTU 1.64 +/-0.69; femoral postoperative BTU 0.95 +/-0.42; p = 0.000// tibial preoperative BTU 1.65 +/- 0.93; tibial postoperative BTU 1.16 +/- 0.48; p = 0.000) and an increase in patellar BTU was observed (p = 0.025). Native varus alignment correlated with a higher medial BTU decrease medially. Undercorrection of preoperative varus alignment showed no higher BTU after TKA. CONCLUSION: Preoperative varus alignment correlated with a higher decrease in BTU in specific femoral and tibial medial regions. Preoperative valgus alignment correlated with a higher decrease in the corresponding lateral regions. Undercorrection of preoperative varus alignment did not lead to higher bone loading reflected by BTU after TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Rótula/cirugía , Estudios Retrospectivos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Tibia/diagnóstico por imagen , Tibia/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...