Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Radiol Cardiothorac Imaging ; 6(2): e230182, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38602469

RESUMEN

Fetal cardiac MRI using Doppler US gating is an emerging technique to support prenatal diagnosis of congenital heart disease and other cardiovascular abnormalities. Analogous to postnatal electrocardiographically gated cardiac MRI, this technique enables directly gated MRI of the fetal heart throughout the cardiac cycle, allowing for immediate data reconstruction and review of image quality. This review outlines the technical principles and challenges of cardiac MRI with Doppler US gating, such as loss of gating signal due to fetal movement. A practical workflow of patient preparation for the use of Doppler US-gated fetal cardiac MRI in clinical routine is provided. Currently applied MRI sequences (ie, cine or four-dimensional flow imaging), with special consideration of technical adaptations to the fetal heart, are summarized. The authors provide a literature review on the clinical benefits of Doppler US-gated fetal cardiac MRI for gaining additional diagnostic information on cardiovascular malformations and fetal hemodynamics. Finally, future perspectives of Doppler US-gated fetal cardiac MRI and further technical developments to reduce acquisition times and eliminate sources of artifacts are discussed. Keywords: MR Fetal, Ultrasound Doppler, Cardiac, Heart, Congenital, Obstetrics, Fetus Supplemental material is available for this article. © RSNA, 2024.


Asunto(s)
Imagen por Resonancia Magnética , Atención Prenatal , Femenino , Embarazo , Humanos , Radiografía , Corazón Fetal/diagnóstico por imagen , Tecnología
2.
J Cardiovasc Magn Reson ; 26(1): 101035, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38460841

RESUMEN

BACKGROUND: Patients are increasingly using Generative Pre-trained Transformer 4 (GPT-4) to better understand their own radiology findings. PURPOSE: To evaluate the performance of GPT-4 in transforming cardiovascular magnetic resonance (CMR) reports into text that is comprehensible to medical laypersons. METHODS: ChatGPT with GPT-4 architecture was used to generate three different explained versions of 20 various CMR reports (n = 60) using the same prompt: "Explain the radiology report in a language understandable to a medical layperson". Two cardiovascular radiologists evaluated understandability, factual correctness, completeness of relevant findings, and lack of potential harm, while 13 medical laypersons evaluated the understandability of the original and the GPT-4 reports on a Likert scale (1 "strongly disagree", 5 "strongly agree"). Readability was measured using the Automated Readability Index (ARI). Linear mixed-effects models (values given as median [interquartile range]) and intraclass correlation coefficient (ICC) were used for statistical analysis. RESULTS: GPT-4 reports were generated on average in 52 s ± 13. GPT-4 reports achieved a lower ARI score (10 [9-12] vs 5 [4-6]; p < 0.001) and were subjectively easier to understand for laypersons than original reports (1 [1] vs 4 [4,5]; p < 0.001). Eighteen out of 20 (90%) standard CMR reports and 2/60 (3%) GPT-generated reports had an ARI score corresponding to the 8th grade level or higher. Radiologists' ratings of the GPT-4 reports reached high levels for correctness (5 [4, 5]), completeness (5 [5]), and lack of potential harm (5 [5]); with "strong agreement" for factual correctness in 94% (113/120) and completeness of relevant findings in 81% (97/120) of reports. Test-retest agreement for layperson understandability ratings between the three simplified reports generated from the same original report was substantial (ICC: 0.62; p < 0.001). Interrater agreement between radiologists was almost perfect for lack of potential harm (ICC: 0.93, p < 0.001) and moderate to substantial for completeness (ICC: 0.76, p < 0.001) and factual correctness (ICC: 0.55, p < 0.001). CONCLUSION: GPT-4 can reliably transform complex CMR reports into more understandable, layperson-friendly language while largely maintaining factual correctness and completeness, and can thus help convey patient-relevant radiology information in an easy-to-understand manner.

3.
Heliyon ; 10(6): e28142, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38533048

RESUMEN

Rationale and objectives: Aim of this study was to assess the impact of contrast media dose (CMD) reduction on diagnostic quality of photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). Methods: CT scans of the abdominal region with differing CMD acquired in portal venous phase on a PCD-CT were included and compared to EID-CT scans. Diagnostic quality and contrast intensity were rated. Additionally, readers had to assign the scans to reduced or regular CMD. Regions-of-interest (ROIs) were placed in defined segments of portal vein, inferior vena cava, liver, spleen, kidneys, abdominal aorta and muscular tissue. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Results: Overall 158 CT scans performed on a PCD-CT and 68 examinations on an EID-CT were analyzed. Overall diagnostic quality showed no significant differences for PCD-CT with standard CMD which scored a median 5 (IQR:5-5) and PCD-CT with 70% CMD scoring 5 (4-5). (For PCD-CT, 71.69% of the examinations with reduced CMD were assigned to regular CMD by the readers, for EID-CT 9.09%. Averaged for all measurements SNR for 50% CMD was reduced by 19% in PCD-CT (EID-CT 34%) and CNR by 48% (EID-CT 56%). Virtual monoenergetic images (VMI)50keV for PCD-CT images acquired with 50% CMD showed an increase in SNR by 72% and CNR by 153%. Conclusions: Diagnostic interpretability of PCD-CT examinations with reduction of up to 50% CMD is maintained. PCD-CT deducted scans especially with 70% CMD were often not recognized as CMD reduced scans. Compared to EID-CT less decline in SNR and CNR is observed for CMD reduced PCD-CT images. Employing VMI50keV for CMD-reduced PCD-CT images compensated for the effects.

4.
Front Radiol ; 4: 1346550, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38445105

RESUMEN

Purpose: Due to a lack of data, there is an ongoing debate regarding the optimal frontline interventional therapy for unresectable hepatocellular carcinoma (HCC). The aim of the study is to compare the results of transarterial radioembolization (TARE) as the first-line therapy and as a subsequent therapy following prior transarterial chemoembolization (TACE) in these patients. Methods: A total of 83 patients were evaluated, with 38 patients having undergone at least one TACE session prior to TARE [27 male; mean age 67.2 years; 68.4% stage Barcelona clinic liver cancer (BCLC) B, 31.6% BCLC C]; 45 patients underwent primary TARE (33 male; mean age 69.9 years; 40% BCLC B, 58% BCLC C). Clinical [age, gender, BCLC stage, activity in gigabecquerel (GBq), Child-Pugh status, portal vein thrombosis, tumor volume] and procedural [overall survival (OS), local tumor control (LTC), and progression-free survival (PFS)] data were compared. A regression analysis was performed to evaluate OS, LTC, and PFS. Results: No differences were found in OS (95% CI: 1.12, P = 0.289), LTC (95% CI: 0.003, P = 0.95), and PFS (95% CI: 0.4, P = 0.525). The regression analysis revealed a relationship between Child-Pugh score (P = 0.005), size of HCC lesions (>10 cm) (P = 0.022), and OS; neither prior TACE (Child-Pugh B patients; 95% CI: 0.120, P = 0.729) nor number of lesions (>10; 95% CI: 2.930, P = 0.087) correlated with OS. Conclusion: Prior TACE does not affect the outcome of TARE in unresectable HCC.

5.
Epilepsia ; 65(5): 1462-1474, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38436479

RESUMEN

OBJECTIVE: Interictal blood-brain barrier dysfunction in chronic epilepsy has been demonstrated in animal models and pathological specimens. Ictal blood-brain barrier dysfunction has been shown in humans in vivo using an experimental quantitative magnetic resonance imaging (MRI) protocol. Here, we hypothesized that interictal blood-brain barrier dysfunction is also present in people with drug-resistant epilepsy. METHODS: Thirty-nine people (21 females, mean age at MRI ± SD = 30 ± 8 years) with drug-resistant epilepsy were prospectively recruited and underwent interictal T1-relaxometry before and after administration of a paramagnetic contrast agent. Likewise, quantitative T1 was acquired in 29 people without epilepsy (12 females, age at MRI = 48 ± 18 years). Quantitative T1 difference maps were calculated and served as a surrogate imaging marker for blood-brain barrier dysfunction. Values of quantitative T1 difference maps inside hemispheres ipsilateral to the presumed seizure onset zone were then compared, on a voxelwise level and within presumed seizure onset zones, to the contralateral side of people with epilepsy and to people without epilepsy. RESULTS: Compared to the contralateral side, ipsilateral T1 difference values were significantly higher in white matter (corrected p < .05), gray matter (uncorrected p < .05), and presumed seizure onset zones (p = .04) in people with epilepsy. Compared to people without epilepsy, significantly higher T1 difference values were found in the anatomical vicinity of presumed seizure onset zones (p = .004). A subgroup of people with hippocampal sclerosis demonstrated significantly higher T1 difference values in the ipsilateral hippocampus and in regions strongly interconnected with the hippocampus compared to people without epilepsy (corrected p < .01). Finally, z-scores reflecting the deviation of T1 difference values within the presumed seizure onset zone were associated with verbal memory performance (p = .02) in people with temporal lobe epilepsy. SIGNIFICANCE: Our results indicate a blood-brain barrier dysfunction in drug-resistant epilepsy that is detectable interictally in vivo, anatomically related to the presumed seizure onset zone, and associated with cognitive deficits.


Asunto(s)
Barrera Hematoencefálica , Epilepsia Refractaria , Imagen por Resonancia Magnética , Humanos , Barrera Hematoencefálica/fisiopatología , Barrera Hematoencefálica/patología , Barrera Hematoencefálica/diagnóstico por imagen , Femenino , Masculino , Adulto , Persona de Mediana Edad , Epilepsia Refractaria/fisiopatología , Epilepsia Refractaria/diagnóstico por imagen , Adulto Joven , Estudios Prospectivos , Epilepsia/fisiopatología , Epilepsia/diagnóstico por imagen
6.
Front Cardiovasc Med ; 11: 1323443, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38410246

RESUMEN

Purpose: This study aims to evaluate deep learning (DL) denoising reconstructions for image quality improvement of Doppler ultrasound (DUS)-gated fetal cardiac MRI in congenital heart disease (CHD). Methods: Twenty-five fetuses with CHD (mean gestational age: 35 ± 1 weeks) underwent fetal cardiac MRI at 3T. Cine imaging was acquired using a balanced steady-state free precession (bSSFP) sequence with Doppler ultrasound gating. Images were reconstructed using both compressed sensing (bSSFP CS) and a pre-trained convolutional neural network trained for DL denoising (bSSFP DL). Images were compared qualitatively based on a 5-point Likert scale (from 1 = non-diagnostic to 5 = excellent) and quantitatively by calculating the apparent signal-to-noise ratio (aSNR) and contrast-to-noise ratio (aCNR). Diagnostic confidence was assessed for the atria, ventricles, foramen ovale, valves, great vessels, aortic arch, and pulmonary veins. Results: Fetal cardiac cine MRI was successful in 23 fetuses (92%), with two studies excluded due to extensive fetal motion. The image quality of bSSFP DL cine reconstructions was rated superior to standard bSSFP CS cine images in terms of contrast [3 (interquartile range: 2-4) vs. 5 (4-5), P < 0.001] and endocardial edge definition [3 (2-4) vs. 4 (4-5), P < 0.001], while the extent of artifacts was found to be comparable [4 (3-4.75) vs. 4 (3-4), P = 0.40]. bSSFP DL images had higher aSNR and aCNR compared with the bSSFP CS images (aSNR: 13.4 ± 6.9 vs. 8.3 ± 3.6, P < 0.001; aCNR: 26.6 ± 15.8 vs. 14.4 ± 6.8, P < 0.001). Diagnostic confidence of the bSSFP DL images was superior for the evaluation of cardiovascular structures (e.g., atria and ventricles: P = 0.003). Conclusion: DL image denoising provides superior quality for DUS-gated fetal cardiac cine imaging of CHD compared to standard CS image reconstruction.

7.
Sci Rep ; 14(1): 497, 2024 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-38177651

RESUMEN

Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (≥ 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100-190 keV (10 keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1-3) and 1 (1-3); e.g. VMI130 keV 2 (1-5); p < 0.0001 and 2 (1-4); p < 0.0001). In quantitative assessment, VMI130 keV showed best results with a corrected attenuation closest to 0 (PI: 30.48 ± 98.16; VMI130 keV: - 0.55 ± 73.38; p = 0.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130 keV showed best results and are recommended to support head and neck CT scans.


Asunto(s)
Implantes Dentales , Artefactos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Mejilla , Relación Señal-Ruido , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
8.
IEEE Trans Med Imaging ; 43(3): 940-953, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37856267

RESUMEN

In cardiac cine magnetic resonance imaging (MRI), the heart is repeatedly imaged at numerous time points during the cardiac cycle. Frequently, the temporal evolution of a certain region of interest such as the ventricles or the atria is highly relevant for clinical diagnosis. In this paper, we devise a novel approach that allows for an automatized propagation of an arbitrary region of interest (ROI) along the cardiac cycle from respective annotated ROIs provided by medical experts at two different points in time, most frequently at the end-systolic (ES) and the end-diastolic (ED) cardiac phases. At its core, a 3D TV- L1 -based optical flow algorithm computes the apparent motion of consecutive MRI images in forward and backward directions. Subsequently, the given terminal annotated masks are propagated by this bidirectional optical flow in 3D, which results, however, in improper initial estimates of the segmentation masks due to numerical inaccuracies. These initially propagated segmentation masks are then refined by a 3D U-Net-based convolutional neural network (CNN), which was trained to enforce consistency with the forward and backward warped masks using a novel loss function. Moreover, a penalization term in the loss function controls large deviations from the initial segmentation masks. This method is benchmarked both on a new dataset with annotated single ventricles containing patients with severe heart diseases and on a publicly available dataset with different annotated ROIs. We emphasize that our novel loss function enables fine-tuning the CNN on a single patient, thereby yielding state-of-the-art results along the complete cardiac cycle.


Asunto(s)
Imagen por Resonancia Cinemagnética , Flujo Optico , Humanos , Imagen por Resonancia Cinemagnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Corazón/diagnóstico por imagen , Ventrículos Cardíacos , Imagen por Resonancia Magnética/métodos , Atrios Cardíacos
9.
Radiology ; 308(3): e230427, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37750774

RESUMEN

Background Deep learning (DL) reconstructions can enhance image quality while decreasing MRI acquisition time. However, DL reconstruction methods combined with compressed sensing for prostate MRI have not been well studied. Purpose To use an industry-developed DL algorithm to reconstruct low-resolution T2-weighted turbo spin-echo (TSE) prostate MRI scans and compare these with standard sequences. Materials and Methods In this prospective study, participants with suspected prostate cancer underwent prostate MRI with a Cartesian standard-resolution T2-weighted TSE sequence (T2C) and non-Cartesian standard-resolution T2-weighted TSE sequence (T2NC) between August and November 2022. Additionally, a low-resolution Cartesian DL-reconstructed T2-weighted TSE sequence (T2DL) with compressed sensing DL denoising and resolution upscaling reconstruction was acquired. Image sharpness was assessed qualitatively by two readers using a five-point Likert scale (from 1 = nondiagnostic to 5 = excellent) and quantitatively by calculating edge rise distance. The Friedman test and one-way analysis of variance with post hoc Bonferroni and Tukey tests, respectively, were used for group comparisons. Prostate Imaging Reporting and Data System (PI-RADS) score agreement between sequences was compared by using Cohen κ. Results This study included 109 male participants (mean age, 68 years ± 8 [SD]). Acquisition time of T2DL was 36% and 29% lower compared with that of T2C and T2NC (mean duration, 164 seconds ± 20 vs 257 seconds ± 32 and 230 seconds ± 28; P < .001 for both). T2DL showed improved image sharpness compared with standard sequences using both qualitative (median score, 5 [IQR, 4-5] vs 4 [IQR, 3-4] for T2C and 4 [IQR, 3-4] for T2NC; P < .001 for both) and quantitative (mean edge rise distance, 0.75 mm ± 0.39 vs 1.15 mm ± 0.68 for T2C and 0.98 mm ± 0.65 for T2NC; P < .001 and P = .01) methods. PI-RADS score agreement between T2NC and T2DL was excellent (κ range, 0.92-0.94 [95% CI: 0.87, 0.98]). Conclusion DL reconstruction of low-resolution T2-weighted TSE sequences enabled accelerated acquisition times and improved image quality compared with standard acquisitions while showing excellent agreement with conventional sequences for PI-RADS ratings. Clinical trial registration no. NCT05820113 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Turkbey in this issue.


Asunto(s)
Aprendizaje Profundo , Neoplasias de la Próstata , Humanos , Masculino , Anciano , Imagen por Resonancia Magnética , Estudios Prospectivos , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía
10.
Diagnostics (Basel) ; 13(13)2023 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-37443565

RESUMEN

Persistent or recurrent cardiovascular symptoms have been identified as one of the hallmarks of long-COVID or post-acute sequelae of SARS-CoV-2 infection (PASC). The purpose of this study was to determine the prevalence and extent of cardiac abnormalities in patients referred for cardiac MRI due to clinical evidence of PASC. To investigate this, two tertiary care hospitals identified all patients who were referred for cardiac MRI under the suspicion of PASC in a 2-year period and retrospectively included them in this study. Patients with previously known cardiac diseases were excluded. This resulted in a total cohort of 129 patients (63, 51% female; age 41 ± 16 years). The majority of patients (57%) showed normal cardiac results. No patient had active myocarditis or an acute myocardial infarction. However, 30% of patients had evidence of non-ischemic myocardial fibrosis, which exceeds the prevalence in the normal adult population and suggests that a possible history of myocarditis might explain persistent symptoms in the PASC setting.

11.
Sci Rep ; 13(1): 8955, 2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37268675

RESUMEN

Aim of this study was to assess the impact of virtual monoenergetic images (VMI) in combination and comparison with iterative metal artifact reduction (IMAR) on hip prosthesis-associated artifacts in photon-counting detector CT (PCD-CT). Retrospectively, 33 scans with hip prosthesis-associated artifacts acquired during clinical routine on a PCD-CT between 08/2022 and 09/2022 were analyzed. VMI were reconstructed for 100-190 keV with and without IMAR, and compared to polychromatic images. Qualitatively, artifact extent and assessment of adjacent soft tissue were rated by two radiologists using 5-point Likert items. Quantitative assessment was performed measuring attenuation and standard deviation in most pronounced hypodense and hyperdense artifacts, artifact-impaired bone, muscle, vessels, bladder and artifact-free corresponding tissue. To quantify artifacts, an adjusted attenuation was calculated as the difference between artifact-impaired tissue and corresponding tissue without artifacts. Qualitative assessment improved for all investigated image reconstructions compared to polychromatic images (PI). VMI100keV in combination with IMAR achieved best results (e.g. diagnostic quality of the bladder: median PI: 1.5 (range 1-4); VMI100keV+IMAR: 5 (3-5); p < 0.0001). In quantitative assessment VMI100keV with IMAR provided best artifact reduction with an adjusted attenuation closest to 0 (e.g. bone: PI: 302.78; VMI100keV+IMAR: 51.18; p < 0.0001). The combination of VMI and IMAR significantly reduces hip prosthesis-associated artifacts in PCD-CT and improves the diagnostic quality of surrounding tissue.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Estudios Retrospectivos , Metales , Tomografía Computarizada por Rayos X/métodos , Artefactos , Algoritmos
12.
J Am Heart Assoc ; 12(9): e029492, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-37119085

RESUMEN

Background The objective of this study was to investigate cardiac abnormalities in intensive care unit (ICU) survivors of critical illness and to determine whether temporary acute kidney injury (AKI) is associated with more pronounced findings on cardiovascular magnetic resonance. Methods and Results There were 2175 patients treated in the ICU (from 2015 until 2021) due to critical illness who were screened for study eligibility. Post-ICU patients without known cardiac disease were prospectively recruited from March 2021 to May 2022. Participants underwent cardiovascular magnetic resonance including assessment of cardiac function, myocardial edema, late gadolinium enhancement, and mapping including extracellular volume fraction. Student t test, Mann-Whitney U test, and χ2 tests were used. There were 48 ICU survivors (46±15 years of age, 28 men, 29 with AKI and continuous kidney replacement therapy, and 19 without AKI) and 20 healthy controls who were included. ICU survivors had elevated markers of myocardial fibrosis (T1: 995±31 ms versus 957±21 ms, P<0.001; extracellular volume fraction: 24.9±2.5% versus 22.8±1.2%, P<0.001; late gadolinium enhancement: 1% [0%-3%] versus 0% [0%-0%], P<0.001), more frequent focal late gadolinium enhancement lesions (21% versus 0%, P=0.03), and an impaired left ventricular function (eg, ejection fraction: 57±6% versus 60±5%, P=0.03; systolic longitudinal strain: 20.3±3.7% versus 23.1±3.5%, P=0.004) compared with healthy controls. ICU survivors with AKI had higher myocardial T1 (1002±33 ms versus 983±21 ms; P=0.046) and extracellular volume fraction values (25.6±2.6% versus 23.9±1.9%; P=0.02) compared with participants without AKI. Conclusions ICU survivors of critical illness without previously diagnosed cardiac disease had distinct abnormalities on cardiovascular magnetic resonance including signs of myocardial fibrosis and systolic dysfunction. Findings were more abnormal in participants who experienced AKI with necessity of continuous kidney replacement therapy during their ICU stay. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT05034588.


Asunto(s)
Lesión Renal Aguda , Cardiomiopatías , Cardiopatías Congénitas , Masculino , Humanos , Adulto , Medios de Contraste , Enfermedad Crítica , Gadolinio , Imagen por Resonancia Cinemagnética , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/etiología , Cardiomiopatías/patología , Fibrosis , Espectroscopía de Resonancia Magnética , Sobrevivientes , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/etiología
13.
Eur J Radiol ; 163: 110831, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37059004

RESUMEN

PURPOSE: To compare standard breath-hold (BH) cine imaging to a radial pseudo-golden-angle free-breathing (FB) technique in congenital heart disease (CHD). METHODS: In this prospective study, short-axis and 4-chamber BH and FB cardiac MRI sequences of 25 participants with CHD acquired at 1.5 Tesla, were quantitatively compared regarding ventricular volumes, function, interventricular septum thickness (IVSD), apparent signal to noise ratio (aSNR), and estimated contrast to noise ratio (eCNR). For qualitative comparison, three image quality criteria (contrast, endocardial edge definition, and artefacts) were rated on a 5-point Likert scale (5: excellent, 1: non-diagnostic). Paired t-Test was used for group comparisons, Bland-Altman analysis for agreement between techniques. Inter-reader agreement was compared using intraclass correlation coefficient. RESULTS: IVSD (BH 7.4 ± 2.1 mm vs FB 7.4 ± 1.9 mm, p =.71), biventricular ejection fraction (left ventricle [LV]: 56.4 ± 10.8% vs 56.1 ± 9.3%, p =.83; right ventricle [RV]: 49.5 ± 8.6% vs 49.7 ± 10.1%, p =.83), and biventricular end diastolic volume (LV: 176.3 ± 63.9 ml vs 173.9 ± 64.9 ml, p =.90; RV: 185.4 ± 63.8 ml vs 189.6 ± 66.6 ml, p =.34) were comparable. Mean measurement time for FB short-axis sequences was 8.1 ± 1.3 compared to 4.4 ± 1.3 min for BH (p <.001). Subjective image quality between sequences was deemed comparable, (4.6 ± 0.6 vs 4.5 ± 0.6, p =.26, for 4-chamber views) with a significant difference regarding short-axis views (4.9 ± 0.3 vs 4.5 ± 0.6, p =.008). aSNR was similar (BH 25.8 ± 11.2 vs FB 22.2 ± 9.5, p =.24), while eCNR was higher for BH (89.1 ± 36.1 vs 68.5 ± 32.1, p =.03). CONCLUSION: FB sequences yielded comparable results to BH regarding image quality, biventricular volumetry, and function, though measurement times were longer. The FB sequence described might be clinically valuable when BHs are insufficiently performed.


Asunto(s)
Cardiopatías Congénitas , Respiración , Humanos , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Contencion de la Respiración , Reproducibilidad de los Resultados
14.
Eur Radiol ; 33(8): 5498-5508, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36949253

RESUMEN

OBJECTIVES: To find simple imaging-based features on cardiac magnetic resonance (CMR) that are associated with major adverse cardiovascular events (MACE) in takotsubo syndrome (TTS). METHODS: Patients with TTS referred for CMR between 2007 and 2021 were retrospectively evaluated. Besides standard CMR analysis, commonly known complications of TTS based on expert knowledge were assessed and summarised via a newly developed PE2RT score (one point each for pleural effusion, pericardial effusion, right ventricular involvement, and ventricular thrombus). Clinical follow-up data was reviewed up to three years after discharge. The relationship between PE2RT features and the occurrence of MACE (cardiovascular death or new hospitalisation due to acute myocardial injury, arrhythmia, or chronic heart failure) was examined using Cox regression analysis and Kaplan-Meier estimator. RESULTS: Seventy-nine patients (mean age, 68 ± 14 years; 72 women) with TTS were included. CMR was performed in a median of 4 days (IQR, 2-6) after symptom onset. Over a median follow-up of 13.3 months (IQR, 0.4-36.0), MACE occurred in 14/79 (18%) patients: re-hospitalisation due to acute symptoms (9/79, 11%) or chronic heart failure symptoms (4/79, 5%), and cardiac death (1/79, 1%). Patients with MACE had a higher PE2RT score (median [IQR], 2 [2-3] vs 1 [0-1]; p < 0.001). PE2RT score was associated with MACE on Cox regression analysis (hazard ratio per PE2RT feature, 2.44; 95%CI: 1.62-3.68; p < 0.001). Two or more PE2RT complications were strongly associated with the occurrence of MACE (log-rank p < 0.001). CONCLUSIONS: The introduced PE2RT complication score might enable an easy-to-assess outcome evaluation of TTS patients by CMR. KEY POINTS: • Complications like pericardial effusion, pleural effusion, right ventricular involvement, and ventricular thrombus (summarised as PE2RT features) are relatively common in takotsubo syndrome. • The proposed PE2RT score (one point per complication) was associated with the occurrence of major adverse cardiac events on follow-up. • Complications easily detected by cardiac magnetic resonance imaging can help clinicians derive long-term prognostic information on patients with takotsubo syndrome.


Asunto(s)
Insuficiencia Cardíaca , Cardiomiopatía de Takotsubo , Trombosis , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Cardiomiopatía de Takotsubo/diagnóstico por imagen , Función Ventricular Izquierda , Estudios Retrospectivos , Imagen por Resonancia Magnética/efectos adversos , Pronóstico , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/etiología , Espectroscopía de Resonancia Magnética , Imagen por Resonancia Cinemagnética/efectos adversos , Valor Predictivo de las Pruebas , Factores de Riesgo
15.
Radiol Cardiothorac Imaging ; 5(1): e220129, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36860838

RESUMEN

Purpose: To apply Doppler US (DUS)-gated fetal cardiac cine MRI in clinical routine and investigate diagnostic performance in complex congenital heart disease (CHD) compared with that of fetal echocardiography. Materials and Methods: In this prospective study (May 2021 to March 2022), women with fetuses with CHD underwent fetal echocardiography and DUS-gated fetal cardiac MRI on the same day. For MRI, balanced steady-state free precession cine images were acquired in the axial and optional sagittal and/or coronal orientations. Overall image quality was assessed on a four-point Likert scale (from 1 = nondiagnostic to 4 = good image quality). The presence of abnormalities in 20 fetal cardiovascular features was independently assessed by using both modalities. The reference standard was postnatal examination results. Differences in sensitivities and specificities were determined by using a random-effects model. Results: The study included 23 participants (mean age, 32 years ± 5 [SD]; mean gestational age, 36 weeks ± 1). Fetal cardiac MRI was completed in all participants. The median overall image quality of DUS-gated cine images was 3 (IQR, 2.5-4). In 21 of 23 participants (91%), underlying CHD was correctly assessed by using fetal cardiac MRI. In one case, the correct diagnosis was made by using MRI only (situs inversus and congenitally corrected transposition of the great arteries). Sensitivities (91.8% [95% CI: 85.7, 95.1] vs 93.6% [95% CI: 88.8, 96.2]; P = .53) and specificities (99.9% [95% CI: 99.2, 100] vs 99.9% [95% CI: 99.5, 100]; P > .99) for the detection of abnormal cardiovascular features were comparable between MRI and echocardiography, respectively. Conclusion: Using DUS-gated fetal cine cardiac MRI resulted in performance comparable with that of using fetal echocardiography for diagnosing complex fetal CHD.Keywords: Pediatrics, MR-Fetal (Fetal MRI), Cardiac, Heart, Congenital, Fetal Imaging, Cardiac MRI, Prenatal, Congenital Heart DiseaseClinical trial registration no. NCT05066399 Supplemental material is available for this article. © RSNA, 2023See also the commentary by Biko and Fogel in this issue.

16.
BMC Neurol ; 23(1): 86, 2023 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-36855093

RESUMEN

BACKGROUND: Outcome assessment in stroke patients is essential for evidence-based stroke care planning. Computed tomography (CT) is the mainstay of diagnosis in acute stroke. This study aimed to investigate whether CT-derived cervical fat-free muscle fraction (FFMF) as a biomarker of muscle quality is associated with outcome parameters after acute ischemic stroke. METHODS: In this retrospective study, 66 patients (mean age: 76 ± 13 years, 30 female) with acute ischemic stroke in the anterior circulation who underwent CT, including CT-angiography, and endovascular mechanical thrombectomy of the middle cerebral artery between August 2016 and January 2020 were identified. Based on densitometric thresholds, cervical paraspinal muscles covered on CT-angiography were separated into areas of fatty and lean muscle and FFMF was calculated. The study cohort was binarized based on median FFMF (cutoff value: < 71.6%) to compare clinical variables and outcome data between two groups. Unpaired t test and Mann-Whitney U test were used for statistical analysis. RESULTS: National Institute of Health Stroke Scale (NIHSS) (12.2 ± 4.4 vs. 13.6 ± 4.5, P = 0.297) and modified Rankin scale (mRS) (4.3 ± 0.9 vs. 4.4 ± 0.9, P = 0.475) at admission, and pre-stroke mRS (1 ± 1.3 vs. 0.9 ± 1.4, P = 0.489) were similar between groups with high and low FFMF. NIHSS and mRS at discharge were significantly better in patients with high FFMF compared to patients with low FFMF (NIHSS: 4.5 ± 4.4 vs. 9.5 ± 6.7; P = 0.004 and mRS: 2.9 ± 2.1 vs.3.9 ± 1.8; P = 0.049). 90-day mRS was significantly better in patients with high FFMF compared to patients with low FFMF (3.3 ± 2.2 vs. 4.3 ± 1.9, P = 0.045). CONCLUSION: Cervical FFMF obtained from routine clinical CT might be a new imaging-based muscle quality biomarker for outcome prediction in stroke patients.


Asunto(s)
Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Proyectos Piloto , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Músculos , Accidente Cerebrovascular/diagnóstico por imagen
17.
Cardiovasc Intervent Radiol ; 46(5): 658-663, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36826490

RESUMEN

PURPOSE: To investigate and compare the physical properties of the new generation Gore VIATORR-Controlled Expansion Endoprosthesis (VCX) to those of the predecessor VIATORR stent in an in vitro experimental setup. MATERIALS AND METHODS: A total of 12 stents (8 VCX; 4 VIATORR; GORE, USA) were examined. Radial resistive force (RRF) and chronic outward force (COF) were assessed using a radial force testing machine (RX-650, Machine Solutions Inc., USA). To assess the radial forces of the VCX above 8 mm, balloon expansion was performed between cycles. RESULTS: All VCX stents show an abrupt decrease in COF at an external diameter of 8.3 mm; RRF decreases likewise at an external diameter of 8.5 mm. The predecessor VIATORR stent without the "controlled expansion" feature shows linear radial force reduction until full expansion at a diameter of 10 mm. The physical properties of the VCX can be altered by balloon modulation. Point of COF (RRF) reduction shifts to 8.5 mm (8.6 mm), 8.6 mm (8.8 mm) and 9.3 mm (9.6 mm) following modulation with a 8 mm, 9 mm and 10 mm balloon. CONCLUSIONS: The VCX shows an abrupt and disproportionate decrease in COF and RRF at an external diameter of 8.3 mm, thus passive expansion to its nominal diameter of 10 mm is not to be expected. By means of balloon dilatation the physical properties of the stent can be altered, enabling customized TIPS creation. The previous VIATORR stent shows continuous COF and RRF until total expansion.


Asunto(s)
Derivación Portosistémica Intrahepática Transyugular , Humanos , Stents , Diseño de Prótesis
18.
Invest Radiol ; 58(3): 209-215, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36070533

RESUMEN

OBJECTIVES: The aim of this study was to compare a new compressed sensing (CS) method for T2-weighted propeller acquisitions (T2 CS ) with conventional T2-weighted propeller sequences (T2 conv ) in terms of achieving a higher image quality, while reducing the acquisition time. MATERIALS AND METHODS: Male participants with a clinical suspicion of prostate cancer were prospectively enrolled and underwent prostate magnetic resonance imaging at 3 T. Axial and sagittal images of the T2 conv sequence and the T2 CS sequence were acquired. Sequences were qualitatively assessed by 2 blinded radiologists concerning artifacts, image-sharpness, lesion conspicuity, capsule delineation, and overall image quality using 5-point Likert items ranging from 1 (nondiagnostic) to 5 (excellent). The apparent signal-to-noise ratio and apparent contrast-to-noise ratio were evaluated. PI-RADS scores were assessed for both sequences. Statistical analysis was performed by using Wilcoxon signed rank test and paired samples t test. Intrarater and interrater reliability of qualitative image evaluation was assessed using intraclass correlation coefficient (ICC) estimates. RESULTS: A total of 29 male participants were included (mean age, 66 ± 8 years). The acquisition time of the T2 CS sequence was respectively 26% (axial plane) and 24% (sagittal plane) shorter compared with the T2 conv sequence (eg, axial: 171 vs 232 seconds; P < 0.001). In the axial plane, the T2 CS sequence had fewer artifacts (4 [4-4.5] vs 4 [3-4]; P < 0.001), better image-sharpness (4 [4-4.5] vs 3 [3-3.5]; P < 0.001), better capsule delineation (4 [3-4] vs 3 [3-3.5]; P < 0.001), and better overall image quality (4 [4-4] vs 4 [3-4]; P < 0.001) compared with the T2 conv sequence. The ratings of lesion conspicuity were similar (4 [4-4] vs 4 [3-4]; P = 0.166). In the sagittal plane, the T2 CS sequence outperformed the T2 conv sequence in the categories artifacts (4 [4-4] vs 3 [3-4]; P < 0.001), image sharpness (4 [4-5] vs 4 [3-4]; P < 0.001), lesion conspicuity (4 [4-4] vs 4 [3-4]; P = 0.002), and overall image quality (4 [4-4] vs 4 [3-4]; P = 0.002). Capsule delineation was similar between both sequences (3 [3-4] vs 3 [3-3]; P = 0.07). Intraobserver and interobserver reliability for qualitative scoring were good (ICC intra: 0.92; ICC inter: 0.86). Quantitative analysis revealed a higher apparent signal-to-noise ratio (eg, axial: 52.2 ± 9.7 vs 22.8 ± 3.6; P < 0.001) and a higher apparent contrast-to-noise ratio (eg, axial: 44.0 ± 9.6 vs 18.6 ± 3.7; P ≤ 0.001) of the T2 CS sequence. PI-RADS scores were the same for both sequences in all participants. CONCLUSIONS: CS-accelerated T2-weighted propeller acquisition had a superior image quality compared with conventional T2-weighted propeller sequences while significantly reducing the acquisition time.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata , Humanos , Masculino , Persona de Mediana Edad , Anciano , Imagen por Resonancia Magnética/métodos , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados , Neoplasias de la Próstata/diagnóstico por imagen , Relación Señal-Ruido , Artefactos
19.
Acta Radiol ; 64(7): 2229-2237, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34747661

RESUMEN

BACKGROUND: Epicardial (ECF) and pericardial fat (PCF) are important prognostic markers for various cardiac diseases. However, volumetry of the fat compartments is time-consuming. PURPOSE: To investigate whether total volume of ECF and PCF can be estimated by axial single-slice measurements and in a four-chamber view. MATERIAL AND METHODS: A total of 113 individuals (79 patients and 34 healthy) were included in this retrospective magnetic resonance imaging (MRI) study. The total volume of ECF and PCF was determined using a 3D-Dixon sequence. Additionally, the area of ECF and PCF was obtained in single axial layers at five anatomical landmarks (left coronary artery, right coronary artery, right pulmonary artery, mitral valve, coronary sinus) of the Dixon sequence and in a four-chamber view of a standard cine sequence. Pearson's correlation coefficient was calculated between the total volume and each single-slice measurement. RESULTS: Axial single-slice measurements of ECF and PCF correlated strongly with the total fat volumes at all landmarks (ECF: r = 0.85-0.94, P < 0.001; PCF: r = 0.89-0.94, P < 0.001). The best correlation was found at the level of the left coronary artery for ECF and PCF (r = 0.94, P < 0.001). Correlation between single-slice measurement in the four-chamber view and the total ECF and PCF volume was lower (r = 0.75 and r = 0.8, respectively, P < 0.001). CONCLUSION: Single-slice measurements allow an estimation of ECF and PCF volume. This time-efficient analysis allows studies of larger patient cohorts and the opportunistic determination of ECF/PCF from routine examinations.


Asunto(s)
Imagen por Resonancia Magnética , Pericardio , Humanos , Estudios Retrospectivos , Pericardio/diagnóstico por imagen , Pericardio/patología , Tórax , Tejido Adiposo/diagnóstico por imagen , Tejido Adiposo/patología
20.
Eur Heart J Cardiovasc Imaging ; 24(7): 949-960, 2023 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-36423215

RESUMEN

AIMS: The exact role of portal hypertension in cirrhotic cardiomyopathy remains unclear, and it is uncertain whether cardiac abnormalities also occur in non-cirrhotic portal hypertension (NCPH). This magnetic resonance imaging (MRI) study aimed to evaluate the presence of subclinical myocardial dysfunction, oedema, and fibrosis in NCPH. METHODS AND RESULTS: In this prospective study (2018-2022), participants underwent multiparametric abdominal and cardiac MRI including assessment of cardiac function, myocardial oedema, late gadolinium enhancement (LGE), and abdominal and cardiac mapping [T1 and T2 relaxation times, extracellular volume fraction (ECV)]. A total of 111 participants were included [44 participants with NCPH (48 ± 15 years; 23 women), 47 cirrhotic controls, and 20 healthy controls]. The cirrhotic group was dichotomized (Child A vs. Child B/C). NCPH participants demonstrated a more hyperdynamic circulation compared with healthy controls (cardiac index: 3.7 ± 0.6 vs. 3.2 ± 0.8 L/min/m², P = 0.004; global longitudinal strain: -27.3 ± 4.6 vs. -24.6 ± 3.5%, P = 0.022). The extent of abnormalities indicating myocardial fibrosis and oedema in NCPH was comparable with Child A cirrhosis (e.g. LGE presence: 32 vs. 33 vs. 69%, P = 0.004; combined T1 and T2 elevations: 46 vs. 27 vs. 69%, P = 0.017; NCPH vs. Child A vs. Child B/C). Correlations between splenic T1 and myocardial T1 values were found (r = 0.41; P = 0.007). Splenic T1 values were associated with the presence of LGE (odds ratio, 1.010; 95% CI: 1.002, 1.019; P = 0.013). CONCLUSION: MRI parameters of myocardial fibrosis and oedema were altered in participants with NCPH to a similar extent as in compensated cirrhosis and were associated with splenic markers of portal hypertension, indicating specific portal hypertensive cardiomyopathy.


Asunto(s)
Cardiomiopatías , Hipertensión Portal , Niño , Humanos , Femenino , Medios de Contraste , Estudios Prospectivos , Gadolinio , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/etiología , Fibrosis , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Edema/diagnóstico por imagen , Edema/etiología , Edema/patología , Hipertensión Portal/diagnóstico por imagen , Hipertensión Portal/etiología , Hipertensión Portal/patología , Imagen por Resonancia Cinemagnética , Valor Predictivo de las Pruebas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA