Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Nat Commun ; 15(1): 6749, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39117667

RESUMEN

Ingestible electronics have the capacity to transform our ability to effectively diagnose and potentially treat a broad set of conditions. Current applications could be significantly enhanced by addressing poor electrode-tissue contact, lack of navigation, short dwell time, and limited battery life. Here we report the development of an ingestible, battery-free, and tissue-adhering robotic interface (IngRI) for non-invasive and chronic electrostimulation of the gut, which addresses challenges associated with contact, navigation, retention, and powering (C-N-R-P) faced by existing ingestibles. We show that near-field inductive coupling operating near 13.56 MHz was sufficient to power and modulate the IngRI to deliver therapeutically relevant electrostimulation, which can be further enhanced by a bio-inspired, hydrogel-enabled adhesive interface. In swine models, we demonstrated the electrical interaction of IngRI with the gastric mucosa by recording conductive signaling from the subcutaneous space. We further observed changes in plasma ghrelin levels, the "hunger hormone," while IngRI was activated in vivo, demonstrating its clinical potential in regulating appetite and treating other endocrine conditions. The results of this study suggest that concepts inspired by soft and wireless skin-interfacing electronic devices can be applied to ingestible electronics with potential clinical applications for evaluating and treating gastrointestinal conditions.


Asunto(s)
Ghrelina , Animales , Porcinos , Ghrelina/metabolismo , Ghrelina/sangre , Robótica/instrumentación , Mucosa Gástrica/metabolismo , Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Femenino , Humanos , Suministros de Energía Eléctrica , Tracto Gastrointestinal , Electrodos
2.
Med ; 5(7): 780-796.e10, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38663403

RESUMEN

BACKGROUND: Dosing of chemotherapies is often calculated according to the weight and/or height of the patient or equations derived from these, such as body surface area (BSA). Such calculations fail to capture intra- and interindividual pharmacokinetic variation, which can lead to order of magnitude variations in systemic chemotherapy levels and thus under- or overdosing of patients. METHODS: We designed and developed a closed-loop drug delivery system that can dynamically adjust its infusion rate to the patient to reach and maintain the drug's target concentration, regardless of a patient's pharmacokinetics (PK). FINDINGS: We demonstrate that closed-loop automated drug infusion regulator (CLAUDIA) can control the concentration of 5-fluorouracil (5-FU) in rabbits according to a range of concentration-time profiles (which could be useful in chronomodulated chemotherapy) and over a range of PK conditions that mimic the PK variability observed clinically. In one set of experiments, BSA-based dosing resulted in a concentration 7 times above the target range, while CLAUDIA keeps the concentration of 5-FU in or near the targeted range. Further, we demonstrate that CLAUDIA is cost effective compared to BSA-based dosing. CONCLUSIONS: We anticipate that CLAUDIA could be rapidly translated to the clinic to enable physicians to control the plasma concentration of chemotherapy in their patients. FUNDING: This work was supported by MIT's Karl van Tassel (1925) Career Development Professorship and Department of Mechanical Engineering and the Bridge Project, a partnership between the Koch Institute for Integrative Cancer Research at MIT and the Dana-Farber/Harvard Cancer Center.


Asunto(s)
Sistemas de Liberación de Medicamentos , Fluorouracilo , Medicina de Precisión , Fluorouracilo/farmacocinética , Fluorouracilo/administración & dosificación , Conejos , Animales , Sistemas de Liberación de Medicamentos/métodos , Medicina de Precisión/métodos , Humanos , Infusiones Intravenosas , Antimetabolitos Antineoplásicos/farmacocinética , Antimetabolitos Antineoplásicos/administración & dosificación
3.
Nat Mater ; 23(9): 1292-1299, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38413810

RESUMEN

Pills are a cornerstone of medicine but can be challenging to swallow. While liquid formulations are easier to ingest, they lack the capacity to localize therapeutics with excipients nor act as controlled release devices. Here we describe drug formulations based on liquid in situ-forming tough (LIFT) hydrogels that bridge the advantages of solid and liquid dosage forms. LIFT hydrogels form directly in the stomach through sequential ingestion of a crosslinker solution of calcium and dithiol crosslinkers, followed by a drug-containing polymer solution of alginate and four-arm poly(ethylene glycol)-maleimide. We show that LIFT hydrogels robustly form in the stomachs of live rats and pigs, and are mechanically tough, biocompatible and safely cleared after 24 h. LIFT hydrogels deliver a total drug dose comparable to unencapsulated drug in a controlled manner, and protect encapsulated therapeutic enzymes and bacteria from gastric acid-mediated deactivation. Overall, LIFT hydrogels may expand access to advanced therapeutics for patients with difficulty swallowing.


Asunto(s)
Hidrogeles , Hidrogeles/química , Animales , Ratas , Porcinos , Polietilenglicoles/química , Alginatos/química
4.
Sci Robot ; 9(87): eadh8170, 2024 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-38416855

RESUMEN

Postoperative ileus (POI) is the leading cause of prolonged hospital stay after abdominal surgery and is characterized by a functional paralysis of the digestive tract, leading to symptoms such as constipation, vomiting, and functional obstruction. Current treatments are mainly supportive and inefficacious and yield acute side effects. Although electrical stimulation studies have demonstrated encouraging pacing and entraining of the intestinal slow waves, no devices exist today to enable targeted intestinal reanimation. Here, we developed an ingestible self-propelling device for intestinal reanimation (INSPIRE) capable of restoring peristalsis through luminal electrical stimulation. Optimizing mechanical, material, and electrical design parameters, we validated optimal deployment, intestinal electrical luminal contact, self-propelling capability, safety, and degradation of the device in ex vivo and in vivo swine models. We compared the INSPIRE's effect on motility in models of normal and depressed motility and chemically induced ileus. Intestinal contraction improved by 44% in anesthetized animals and up to 140% in chemically induced ileus cases. In addition, passage time decreased from, on average, 8.6 days in controls to 2.5 days with the INSPIRE device, demonstrating significant improvement in motility. Luminal electrical stimulation of the intestine via the INSPIRE efficaciously restored peristaltic activity. This noninvasive option offers a promising solution for the treatment of ileus and other motility disorders.


Asunto(s)
Ileus , Robótica , Animales , Porcinos , Motilidad Gastrointestinal/fisiología , Ileus/terapia , Ileus/etiología , Intestinos , Complicaciones Posoperatorias
5.
Adv Sci (Weinh) ; 11(9): e2308346, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38084435

RESUMEN

Modulation of autophagy, specifically its inhibition, stands to transform the capacity to effectively treat a broad range of cancers. However, the clinical efficacy of autophagy inhibitors has been inconsistent. To delineate clinical and epidemiological features associated with autophagy inhibition and a positive oncological clinical response, a retrospective analysis of patients is conducted treated with hydroxychloroquine, a known autophagy inhibitor. A direct correlation between smoking status and inhibition of autophagy with hydroxychloroquine is identified. Recognizing that smoking is associated with elevated circulating levels of carbon monoxide (CO), it is hypothesized that supplemental CO can amplify autophagy inhibition. A novel, gas-entrapping material containing CO in a pre-clinical model is applied and demonstrated that CO can dramatically increase the cytotoxicity of autophagy inhibitors and significantly inhibit the growth of tumors when used in combination. These data support the notion that safe, therapeutic levels of CO can markedly enhance the efficacy of autophagy inhibitors, opening a promising new frontier in the quest to improve cancer therapies.


Asunto(s)
Hidroxicloroquina , Neoplasias Pulmonares , Masculino , Humanos , Hidroxicloroquina/efectos adversos , Neoplasias Pulmonares/tratamiento farmacológico , Monóxido de Carbono/farmacología , Próstata , Estudios Retrospectivos , Autofagia
6.
Emerg Infect Dis ; 30(1): 129-132, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38147044

RESUMEN

The site of enterohepatic Helicobacter colonization/infection in humans is still unknown. We report microbiologically and histopathologically confirmed H. fennelliae localization in the large intestine in an immunocompromised patient in Japan. This case contributes to better understanding of the life cycle of enterohepatic Helicobacter species.


Asunto(s)
Helicobacter , Intestinos , Humanos , Japón , Helicobacter/genética , Huésped Inmunocomprometido
7.
Sci Adv ; 9(51): eadj3003, 2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-38134286

RESUMEN

Effective therapies for obesity require invasive surgical and endoscopic interventions or high patient adherence, making it challenging for patients with obesity to effectively manage their disease. Gastric mechanoreceptors sense distension of the stomach and perform volume-dependent vagal signaling to initiate the gastric phase and influence satiety. In this study, we developed a new luminal stimulation modality to specifically activate these gastric stretch receptors to elicit a vagal afferent response commensurate with mechanical distension. We designed the Vibrating Ingestible BioElectronic Stimulator (VIBES) pill, an ingestible device that performs luminal vibratory stimulation to activate mechanoreceptors and stroke mucosal receptors, which induces serotonin release and yields a hormonal metabolic response commensurate with a fed state. We evaluated VIBES across 108 meals in swine which consistently led to diminished food intake (~40%, P < 0.0001) and minimized the weight gain rate (P < 0.05) as compared to untreated controls. Application of mechanoreceptor biology could transform our capacity to help patients suffering from nutritional disorders.


Asunto(s)
Obesidad , Estómago , Humanos , Animales , Porcinos , Obesidad/terapia , Obesidad/metabolismo , Mecanorreceptores/metabolismo , Aumento de Peso , Nervio Vago/fisiología
8.
ACS Mater Lett ; 5(9): 2508-2517, 2023 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-37680546

RESUMEN

Delivering heat in vivo could enhance a wide range of biomedical therapeutic and diagnostic technologies, including long-term drug delivery devices and cancer treatments. To date, providing thermal energy is highly power-intensive, rendering it oftentimes inaccessible outside of clinical settings. We developed an in vivo heating method based on the exothermic reaction between liquid-metal-activated aluminum and water. After establishing a method for consistent activation, we characterized the heat generation capabilities with thermal imaging and heat flux measurements. We then demonstrated one application of this reaction: to thermally actuate a gastric resident device made from a shape-memory alloy called Nitinol. Finally, we highlight the advantages and future directions for leveraging this novel in situ heat generation method beyond the showcased example.

9.
Nat Electron ; 6(3): 242-256, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37745833

RESUMEN

Localization and tracking of ingestible microdevices in the gastrointestinal (GI) tract is valuable for the diagnosis and treatment of GI disorders. Such systems require a large field-of-view of tracking, high spatiotemporal resolution, wirelessly operated microdevices and a non-obstructive field generator that is safe to use in practical settings. However, the capabilities of current systems remain limited. Here, we report three dimensional (3D) localization and tracking of wireless ingestible microdevices in the GI tract of large animals in real time and with millimetre-scale resolution. This is achieved by generating 3D magnetic field gradients in the GI field-of-view using high-efficiency planar electromagnetic coils that encode each spatial point with a distinct magnetic field magnitude. The field magnitude is measured and transmitted by the miniaturized, low-power and wireless microdevices to decode their location as they travel through the GI tract. This system could be useful for quantitative assessment of the GI transit-time, precision targeting of therapeutic interventions and minimally invasive procedures.

10.
J Gen Fam Med ; 24(5): 307-310, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37727618

RESUMEN

We report a case of mild encephalitis/encephalopathy with a reversible splenial lesion (MERS) in a 31-year-old man. He had been diagnosed with mild COVID-19 3 days earlier and presented to the emergency department with altered mental status. Brain magnetic resonance imaging (MRI) showed a high-intensity area confined to the splenium of the corpus callosum on diffusion-weighted imaging, which is consistent with MERS. MERS is characterized by a reversible change in the splenium of the corpus callosum. MERS secondary to COVID-19 has been reported recently. It is important to consider MERS in COVID-19 patients with impaired consciousness.

11.
AAPS J ; 25(5): 81, 2023 08 17.
Artículo en Inglés | MEDLINE | ID: mdl-37589795

RESUMEN

mRNA vaccines can be translated into protein antigens, in vivo, to effectively induce humoral and cellular immunity against these proteins. While current mRNA vaccines have generated potent immune responses, the need for ultracold storage conditions (- 80 °C) and healthcare professionals to administer the vaccine through the parenteral route has somewhat limited their distribution in rural areas and developing countries. Overcoming these challenges stands to transform future deployment of mRNA vaccines. In this study, we developed an mRNA vaccine that can trigger a systemic immune response through administration via the gastrointestinal (GI) tract and is stable at 4 °C. A library of cationic branched poly(ß-amino ester) (PBAE) polymers was synthesized and characterized, from which a polymer with high intracellular mRNA delivery efficiency and immune stimulation capacity was down-selected. mRNA vaccines made with the lead polymer-elicited cellular and humoral immunity in mice. Furthermore, lyophilization conditions of the formulation were optimized to enable storage under refrigeration. Our results suggest that PBAE nanoparticles are potent mRNA delivery platforms that can elicit B cell and T cell activation, including antigen-specific cellular and humoral responses. This system can serve as an easily administrable, potent oral mRNA vaccine.


Asunto(s)
Nanopartículas , Vacunas Sintéticas , Animales , Ratones , Vacunas de ARNm , Linfocitos B
12.
bioRxiv ; 2023 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-37503258

RESUMEN

Effective therapies for obesity either require invasive surgical or endoscopic interventions or high patient adherence, making it challenging for the nearly 42% of American adults who suffer from obesity to effectively manage their disease. Gastric mechanoreceptors sense distension of the stomach and perform volume-dependent vagal signaling to initiate the gastric phase and influence satiety. In this study, we developed a new luminal stimulation modality to specifically activate these gastric stretch receptors to elicit a vagal afferent response commensurate with mechanical distension. Here we developed the Vibrating Ingestible BioElectronic Stimulator (VIBES) pill - an ingestible device that performs luminal vibratory stimulation to activate mechanoreceptors and stroke mucosal receptors, which induces serotonin release as well as yields a hormonal metabolic response commensurate with a fed state. We evaluated VIBES across 108 meals in swine which consistently led to diminished food intake (~40%, p< 0.0001) and minimized the weight gain rate (p< 0.03) as compared to untreated controls. Application of mechanoreceptor biology could transform our capacity to help patients suffering from nutritional disorders.

13.
Adv Healthc Mater ; 12(27): e2301033, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37314859

RESUMEN

Patient adherence to chronic therapies can be suboptimal, leading to poor therapeutic outcomes. Dosage forms that enable reduction in dosing frequency stand to improve patient adherence. Variation in gastrointestinal transit time, inter-individual differences in gastrointestinal physiology and differences in physicochemical properties of drugs represent challenges to the development of such systems. To this end, a small intestine-targeted drug delivery system is developed, where prolonged gastrointestinal retention and sustained release are achieved through tissue adhesion of drug pills mediated by an essential intestinal enzyme catalase. Here proof-of-concept pharmacokinetics is demonstrated in the swine model for two drugs, hydrophilic amoxicillin and hydrophobic levodopa. It is anticipated that this system can be applicable for many drugs with a diverse of physicochemical characteristics.


Asunto(s)
Adhesivos , Sistemas de Liberación de Medicamentos , Humanos , Animales , Porcinos , Preparaciones Farmacéuticas , Tracto Gastrointestinal , Intestino Delgado
14.
Med ; 4(8): 541-553.e5, 2023 08 11.
Artículo en Inglés | MEDLINE | ID: mdl-37339635

RESUMEN

BACKGROUND: While peripheral nerve stimulation (PNS) has shown promise in applications ranging from peripheral nerve regeneration to therapeutic organ stimulation, clinical implementation has been impeded by various technological limitations, including surgical placement, lead migration, and atraumatic removal. METHODS: We describe the design and validation of a platform technology for nerve regeneration and interfacing: adaptive, conductive, and electrotherapeutic scaffolds (ACESs). ACESs are comprised of an alginate/poly-acrylamide interpenetrating network hydrogel optimized for both open surgical and minimally invasive percutaneous approaches. FINDINGS: In a rodent model of sciatic nerve repair, ACESs significantly improved motor and sensory recovery (p < 0.05), increased muscle mass (p < 0.05), and increased axonogenesis (p < 0.05). Triggered dissolution of ACESs enabled atraumatic, percutaneous removal of leads at forces significantly lower than controls (p < 0.05). In a porcine model, ultrasound-guided percutaneous placement of leads with an injectable ACES near the femoral and cervical vagus nerves facilitated stimulus conduction at significantly greater lengths than saline controls (p < 0.05). CONCLUSION: Overall, ACESs facilitated lead placement, stabilization, stimulation, and atraumatic removal, enabling therapeutic PNS as demonstrated in small- and large-animal models. FUNDING: This work was supported by K. Lisa Yang Center for Bionics at MIT.


Asunto(s)
Estimulación Eléctrica Transcutánea del Nervio , Animales , Porcinos , Nervio Ciático , Ultrasonografía , Regeneración Nerviosa/fisiología
16.
Sci Robot ; 8(77): eade9676, 2023 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-37099636

RESUMEN

The gut-brain axis, which is mediated via enteric and central neurohormonal signaling, is known to regulate a broad set of physiological functions from feeding to emotional behavior. Various pharmaceuticals and surgical interventions, such as motility agents and bariatric surgery, are used to modulate this axis. Such approaches, however, are associated with off-target effects or post-procedure recovery time and expose patients to substantial risks. Electrical stimulation has also been used to attempt to modulate the gut-brain axis with greater spatial and temporal resolution. Electrical stimulation of the gastrointestinal (GI) tract, however, has generally required invasive intervention for electrode placement on serosal tissue. Stimulating mucosal tissue remains challenging because of the presence of gastric and intestinal fluid, which can influence the effectiveness of local luminal stimulation. Here, we report the development of a bioinspired ingestible fluid-wicking capsule for active stimulation and hormone modulation (FLASH) capable of rapidly wicking fluid and locally stimulating mucosal tissue, resulting in systemic modulation of an orexigenic GI hormone. Drawing inspiration from Moloch horridus, the "thorny devil" lizard with water-wicking skin, we developed a capsule surface capable of displacing fluid. We characterized the stimulation parameters for modulation of various GI hormones in a porcine model and applied these parameters to an ingestible capsule system. FLASH can be orally administered to modulate GI hormones and is safely excreted with no adverse effects in porcine models. We anticipate that this device could be used to treat metabolic, GI, and neuropsychiatric disorders noninvasively with minimal off-target effects.


Asunto(s)
Hambre , Robótica , Animales , Porcinos , Hormonas
17.
Adv Mater ; 35(11): e2208227, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36321332

RESUMEN

Actively triggerable materials, which break down upon introduction of an exogenous stimulus, enable precise control over the lifetime of biomedical technologies, as well as adaptation to unforeseen circumstances, such as changes to an established treatment plan. Yet, most actively triggerable materials are low-strength polymers and hydrogels with limited long-term durability. By contrast, metals possess advantageous functional properties, including high mechanical strength and conductivity, that are desirable across several applications within biomedicine. To realize actively triggerable metals, a mechanism called liquid metal embrittlement is leveraged, in which certain liquid metals penetrate the grain boundaries of certain solid metals and cause them to dramatically weaken or disintegrate. In this work, it is demonstrated that eutectic gallium indium (EGaIn), a biocompatible alloy of gallium, can be formulated to reproducibly trigger the breakdown of aluminum within different physiologically relevant environments. The breakdown behavior of aluminum after triggering can further be readily controlled by manipulating its grain structure. Finally, three possible use cases of biomedical devices constructed from actively triggerable metals are demonstrated.


Asunto(s)
Aluminio , Galio , Aleaciones , Galio/química , Indio/química , Conductividad Eléctrica
18.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2491-2494, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-36085797

RESUMEN

More than two decades ago it was discovered that nitric oxide (NO) concentrations in gas aspirated during colonoscopy were more than 100 times higher in patients diagnosed with Ulcerative Colitis (UC) than controls. While this provides a diagnostic opportunity, it has not been possible to perform in situ detection of NO via a non-invasive manner. This work presents the feasibility of in situ detection of NO by means of a capsule-like electrochemical gas sensor. Our in vivo results in a large animal model of intestinal inflammation show that NO can be directly detected at the site of inflammation and that it quickly dissipates to surrounding tissues, demonstrating the importance of in situ detection.


Asunto(s)
Inflamación , Óxido Nítrico , Animales , Biomarcadores , Colonoscopía , Modelos Animales de Enfermedad , Inflamación/diagnóstico
19.
Sci Robot ; 7(70): eabp9066, 2022 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-36170378

RESUMEN

Oral drug delivery of proteins is limited by the degradative environment of the gastrointestinal tract and poor absorption, requiring parenteral administration of these drugs. Luminal mucus represents the initial steric and dynamic barrier to absorption. To overcome this barrier, we report the development of the RoboCap, an orally ingestible, robotic drug delivery capsule that locally clears the mucus layer, enhances luminal mixing, and topically deposits the drug payload in the small intestine to enhance drug absorption. RoboCap's mucus-clearing and churning movements are facilitated by an internal motor and by surface features that interact with small intestinal plicae circulares, villi, and mucus. Vancomycin (1.4 kilodaltons of glycopeptide) and insulin (5.8 kilodaltons of peptide) delivery mediated by RoboCap resulted in enhanced bioavailability 20- to 40-fold greater in ex vivo and in vivo swine models when compared with standard oral delivery (P < 0.05). Further, insulin delivery via the RoboCap resulted in therapeutic hypoglycemia, supporting its potential to facilitate oral delivery of drugs that are normally precluded by absorption limitations.


Asunto(s)
Nanopartículas , Procedimientos Quirúrgicos Robotizados , Administración Oral , Animales , Tracto Gastrointestinal/metabolismo , Insulina/metabolismo , Moco/metabolismo , Péptidos/metabolismo , Porcinos , Vancomicina/metabolismo
20.
Biomaterials ; 288: 121703, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36030104

RESUMEN

Intravesical instillation is an efficient drug delivery route for the local treatment of various urological conditions. Nevertheless, intravesical instillation is associated with several challenges, including pain, urological infection, and frequent clinic visits for catheterization; these difficulties support the need for a simple and easy intravesical drug delivery platform. Here, we propose a novel biodegradable intravesical device capable of long-term, local drug delivery without a retrieval procedure. The intravesical device is composed of drug encapsulating biodegradable polycaprolactone (PCL) microcapsules and connected by a bioabsorbable Polydioxanone (PDS) suture with NdFeB magnets in the end. The device is easily inserted into the bladder and forms a 'ring' shape optimized for maximal mechanical stability as informed by finite element analysis. In this study, inserted devices were retained in a swine model for 4 weeks. Using this device, we evaluated the system's capacity for delivery of lidocaine and resiquimod and demonstrated prolonged drug release. Moreover, a cost-effectiveness analysis supports device implementation compared to the standard of care. Our data support that this device can be a versatile drug delivery platform for urologic medications.


Asunto(s)
Sistemas de Liberación de Medicamentos , Vejiga Urinaria , Administración Intravesical , Animales , Sistemas de Liberación de Medicamentos/métodos , Liberación de Fármacos , Porcinos , Vejiga Urinaria/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...