Clin Biomech (Bristol, Avon) ; 120: 106362, 2024 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-39447321

RESUMEN

BACKGROUND: While traditional metallic cerclage remains the primary method in clinical application, non-metallic cerclage systems have recently gained popularity due to low risks of soft tissue irritation and bone intrusion. The objective of this study was to assess the performance of a novel non-metallic suture-based cerclage in comparison to traditional metallic cerclage cables for fixation of periprosthetic femoral fractures. METHODS: An extended trochanteric osteotomy was performed on eight pairs of cadaveric femora, followed by reduction using either metallic cerclages (Group I) or the suture-based cerclage (Group II). A modular tapered fluted stem was then implanted in each specimen. The fragment translation during canal preparation and stem implantation was quantified using laser-scanning. Subsequently, each specimen underwent 500 cycles of multiaxial loading, with fragment translation and stem subsidence measured using a motion capture system. FINDINGS: Following stem implantation, specimens in Group II exhibited a significantly greater lateral fragment translation (466 µm vs 754 µm, p = 0.017). However, there were no significant differences in anterior and distal translation between groups (p > 0.05). During multiaxial loading, the average stem subsidence in Group I was 0.36 mm (range, 0.04-1.42 mm), compared to 0.41 mm (range, 0.03-1.29) in Group II (p > 0.05). No significant difference was found in fragment translations between the two groups (p > 0.05). INTERPRETATION: The suture-based cerclage system exhibited comparable biomechanical performance in fixation stability to conventional metallic cerclage cables. Yet, it was associated with a larger residual lateral gap between the fragments following stem implantation. Ultimately, the choice of fixation method should account for multiple factors, including patient characteristics, surgeon preference, and bone quality.

2.
J Orthop Trauma ; 38(9): 491-496, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39150300

RESUMEN

OBJECTIVES: Prophylactic cerclage cables are often placed intraoperatively about a fracture to prevent propagation. However, biomechanical data supporting optimal cable placement location are lacking. The objective of this study was to evaluate the impact of prophylactic cerclage placement location on the propagation of femoral shaft fractures. METHODS: The diaphysis of 14 fresh-frozen cadaveric femora were included. Volumetric bone mineral density in the femoral shaft was obtained from quantitative computed tomography scans. For each specimen, a 5-mm longitudinal fracture was created proximally to simulate a pre-existing fracture. After reaming of the femoral canal, a 3 degrees tapered wedge was advanced with an MTS machine at 0.2 mm/s until failure. The tests were conducted with a CoCr cable placed at varying distances (5 mm, 10 mm, 15 mm, 20 mm, and cableless) from the distal tip of the initial fracture. A compression loadcell was used to measure the cable tension during the tests. The axial force, displacement, and cable tension were monitored for comparison between groups. RESULTS: In the cableless group, the mean force needed to propagate the fracture was 1017.8 ± 450.3 N. With the addition of a cable at 5 mm below the fracture, the failure force nearly doubled to 1970.4 ± 801.1 N (P < 0.001). This also led to significant increases in stiffness (P = 0.006) and total work (P = 0.001) when compared with the control group. By contrast, in the 15 and 20 mm groups, there were no significant changes in the failure force, stiffness, and total work as compared with the control group (P > 0.05). CONCLUSIONS: Propagation of femoral shaft fracture was effectively resisted when a prophylactic cable was placed within 5 mm from the initial fracture, whereas cables placed more than 10 mm below the initial fracture were not effective in preventing fracture propagation.


Asunto(s)
Cadáver , Fracturas del Fémur , Humanos , Fracturas del Fémur/cirugía , Fracturas del Fémur/prevención & control , Fracturas del Fémur/fisiopatología , Femenino , Anciano , Masculino , Fenómenos Biomecánicos , Hilos Ortopédicos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Anciano de 80 o más Años , Persona de Mediana Edad
3.
Clin Biomech (Bristol, Avon) ; 118: 106303, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38991405

RESUMEN

BACKGROUND: In total hip arthroplasty via the direct anterior approach, appropriate exposure is critical to allow preparation of the femur. The objective of this study was to explore the optimal soft tissue releases needed to allow broaching of the femur through a combination of experimental tests and computer simulations. METHODS: Fourteen full-body cadaveric specimens were included in this study. Total hip arthroplasty was performed via the direct anterior approach with the femur at 20° adduction and 20°extension. Soft tissue releases were performed sequentially, namely, the transverse iliofemoral ligament, descending iliofemoral ligament, ischio-femoral ligament, conjoint tendon, and obturator externus. After each release, the femur mobility was assessed by applying a 6 Nm external rotation torque and a 120 N distraction force. Subsequently, using specimen-specific models and models of the broach and handle, the broach passage after each release was simulated, and the release that allowed broach passage was analyzed. FINDINGS: The average external rotation after releasing the transverse and descending iliofemoral ligaments increased by 14.1° ± 6.1° and 13.8° ± 5.3°. With subsequent soft tissue releases, the rotational mobility increased incrementally, though the impact decreased. Impingement between the broach passage and the pelvis was mainly at the anterior superior iliac spine and the anterior inferior iliac spine. The volume of impingement decreased from 4.8 ± 4.5 cm3 after resection of the femoral head to 1.8 ± 1.6 cm3 and 1.2 ± 1.9 cm3 after release of the transverse and descending iliofemoral ligament, respectively. INTERPRETATION: With sequential soft-tissue releases, the femur mobility increased incrementally. However, the number of releases needed for each femur varied extensively between specimens. Most (10/14) femurs became accessible after the release of the ilio-femoral or ischio-femoral ligament.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fémur , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Masculino , Simulación por Computador , Articulación de la Cadera/cirugía , Articulación de la Cadera/fisiopatología , Femenino , Anciano , Cadáver , Rango del Movimiento Articular , Persona de Mediana Edad , Rotación , Ligamentos/cirugía , Fenómenos Biomecánicos , Cápsula Articular/cirugía , Cápsula Articular/fisiopatología
4.
Am J Sports Med ; 52(4): 968-976, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38343203

RESUMEN

BACKGROUND: Historical MCL (medial collateral ligament) reconstruction (MCLR) techniques have focused on the superficial MCL (sMCL) to restore valgus stability while frequently ignoring the importance of the deep MCL (dMCL) in controlling tibial external rotation. The recent recognition of the medial ligament complex importance has multiple studies revisiting medial anatomy and questioning contemporary MCLR techniques. PURPOSE: To assess whether (1) an isolated sMCL reconstruction (sMCLR), (2) an isolated dMCL reconstruction (dMCLR), or (3) a novel single-strand short isometric construct (SIC) would restore translational and rotational stability to a knee with a dMCL and sMCL injury. STUDY DESIGN: Controlled laboratory study. METHODS: Biomechanical testing was performed on 14 fresh-frozen cadaveric knee specimens using a custom multiaxial knee activity simulator. The specimens were divided into 2 groups. The first group was tested in 4 states: intact, after sectioning the sMCL and dMCL, isolated sMCLR, and isolated dMCLR. The second group was tested in 3 states: intact, after sectioning the sMCL and dMCL, and after single-strand SIC reconstruction (SICR). In each state, 4 loading conditions were applied at 0°, 20°, 40°, 60°, and 90° of knee flexion: 8-N·m valgus torque, 5-N·m external rotation torque, 90-N anterior drawer, and combined 90-N anterior drawer plus 5-N·m tibial external rotation torque. Anterior translation, valgus rotation, and external rotation of the knee were measured for each state and loading condition using an optical motion capture system. RESULTS: sMCL and dMCL transection resulted in increased laxity for all loading conditions at all flexion angles. Isolated dMCLR restored external rotation stability to intact levels throughout all degrees of flexion, yet valgus stability was restored only at 0° of flexion. Isolated sMCLR restored valgus and external rotation stability at 0°, 20°, and 40° of flexion but not at 60° or 90° of flexion. Single-strand SICR restored valgus and external rotation stability at all flexion angles. In the combined anterior drawer plus external rotation test, isolated dMCL and single-strand SICR restored stability to the intact level at all flexion angles, while the isolated sMCL restored stability at 20° and 40° of flexion but not at 60° or 90° of flexion. CONCLUSION: In the cadaveric model, single-strand SICR restored valgus and rotational stability throughout the range of motion. dMCLR restored rotational stability to the knee throughout the range of motion but did not restore valgus stability. Isolated sMCLR restored external rotation and valgus stability in early flexion. CLINICAL RELEVANCE: In patients with anteromedial rotatory instability in the knee, neither an sMCLR nor a dMCLR is sufficient to restore stability.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Ligamentos Colaterales , Inestabilidad de la Articulación , Adulto , Humanos , Fenómenos Biomecánicos , Inestabilidad de la Articulación/cirugía , Cadáver , Articulación de la Rodilla/cirugía , Lesiones del Ligamento Cruzado Anterior/cirugía , Rango del Movimiento Articular , Ligamentos Colaterales/cirugía
5.
Clin Biomech (Bristol, Avon) ; 111: 106160, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38096680

RESUMEN

BACKGROUND: Pelvic tilt is an important sagittal parameter that varies greatly among individuals. The objective of this study was to quantify the effect of pelvic tilt on femoral head coverage and range of motion in a dysplastic population following periacetabular osteotomy. METHODS: Twenty-three dysplastic hips from 19 patients (17 female, 2 male) were included in this study. Three-dimensional models were reconstructed using pre-operative CT images, and patient-specific neutral pelvic tilt was obtained on an anteroposterior X-ray. Following a simulated periacetabular osteotomy, the pelvic tilt was changed from -15° to +15°, and the effects on femoral head coverage and hip range of motion was quantified using a customized MATLAB program. FINDINGS: Pelvic tilt did not significantly affect total femoral head coverage (P > 0.2). However, a 15° anterior tilt from neutral resulted in a 17.72 ± 9.45% increase in anterolateral coverage and a 23.96 ± 7.48% decrease in posterolateral coverage (P < 0.0001), as well as an 18.2 ± 8.4° loss of internal rotation at 90° of hip flexion. Contrarily, posterior pelvic tilt led to a 26.79 ± 9.04% reduction in anterolateral coverage (P < 0.0001) and an 18.02 ± 9.57% increase in posterolateral coverage (P < 0.0001), and the maximum internal rotation increased 11.8 ± 3.7°. INTERPRETATION: While pelvic tilt did not affect total femoral head coverage, it had a significant impact on the distribution of coverage within the superolateral region of the femoral head. Anterior pelvic tilt led to increased anterolateral coverage, but also had a negative impact on hip range of motion. An optimal surgical plan should achieve adequate coverage while not significantly limiting the patient's mobility.


Asunto(s)
Acetábulo , Cabeza Femoral , Humanos , Masculino , Femenino , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/cirugía , Tomografía Computarizada por Rayos X , Postura , Osteotomía/métodos , Estudios Retrospectivos , Articulación de la Cadera/cirugía
6.
J Arthroplasty ; 2023 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-38072096

RESUMEN

BACKGROUND: The morphology of the trochlear compartment of total knee arthroplasty (TKA) prostheses is a major determinant of postoperative patello-femoral kinematics, particularly with unresurfaced patellae. The objective of this study was to quantify and compare the trochlear morphology of a large series of contemporary and legacy TKA designs. METHODS: The 3-dimensional surface models of 22 femoral components (13 contemporary and 9 legacy) were created using high-resolution laser scanning. The trochlear profile of each component was analyzed from proximal to distal in 15° increments around the trochlear axis. In each profile, the following variables were measured: sulcus angle, medio-lateral deviation of the sulcus, the height and width of the facets, and the trochlear groove orientation. RESULTS: In the contemporary group, the sulcus angle decreased progressively along the trochlear arc to varying degrees, except for 2 symmetrical designs, whereas the sulcus angle of the legacy designs showed considerable variability. The height of the medial facet was very strongly correlated with that of the lateral facet in the contemporary group (R2 = 0.89), whereas the correlation was weak for the legacy designs (R2 = 0.36). Moreover, the trochlear sulcus deviated laterally from distal to proximal in 10 contemporary designs and 7 legacy designs, resulting in a trochlear groove orientation of 4.2 to 11.1° and 4.3 to 10.5°, respectively. In the remaining 5 designs (3 contemporary and 2 legacy), the sulcus was vertical. CONCLUSIONS: There is more consistency in trochlear morphology of contemporary TKA designs compared to that of legacy designs, yet there are still large variations between different designs.

7.
J Arthroplasty ; 38(7S): S292-S297, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36933680

RESUMEN

BACKGROUND: Due to increasing volume of total hip arthroplasties, periprosthetic femoral fractures have become a common complication with increased revision burden and perioperative morbidity. The objective of this study was to evaluate the fixation stability of Vancouver B2 fractures treated with 2 techniques. METHODS: A common B2 fracture was created by reviewing 30 type B2 cases. The fracture was then reproduced in 7 pairs of cadaveric femora. The specimens were divided into 2 groups. In Group I ("reduce-first"), the fragments were reduced first, followed by implantation of a tapered fluted stem. In Group II ("ream-first"), the stem was implanted in the distal femur first, followed by fragment reduction and fixation. Each specimen was loaded in a multiaxial testing frame with 70% of peak load during walking. A motion capture system was used to track the motion of the stem and fragments. RESULTS: The average stem diameter in Group II was 16.1 ± 0.4 mm, versus 15.4 ± 0.5 mm in Group I. The fixation stability was not significantly different in the 2 groups. After the testing, the average stem subsidence was 0.36 ± 0.31 mm and 0.19 ± 0.14 mm (P = .17) and the average rotation was 1.67 ± 1.30° and 0.91 ± 1.11° (P = .16) in Groups I and II, respectively. Compared to the stem, there was less motion of the fragments and there was no difference between the 2 groups (P > .05). CONCLUSIONS: When tapered fluted stems were used in combination with cerclage cables for treatment of Vancouver type B2 periprosthetic femoral fractures, both the "reduce-first" and "ream-first" techniques showed adequate stem and fracture stability.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Humanos , Prótesis de Cadera/efectos adversos , Reoperación/efectos adversos , Resultado del Tratamiento , Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas Periprotésicas/cirugía , Fracturas Periprotésicas/complicaciones , Fémur/cirugía , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas/efectos adversos , Estudios Retrospectivos
8.
J Arthroplasty ; 37(7S): S697-S702, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35307531

RESUMEN

BACKGROUND: Diaphyseal fixation remains the mainstay of revision THA. The stability of diaphyseal fixation can be quantified by the extent of contact between the stem and the endosteal cortex. This is highly affected by the morphology of the proximal femur. The purpose of this study was to examine factors affecting diaphyseal contact in the revision THA and to identify preoperative predictors of adequate fixation. METHODS: Three-dimensional femur models were created from CT scans of 33 Dorr B and C femora. The proximal 120 mm of the femur was omitted to mimic proximal bone deficiency. A tapered fluted stem (3 degrees, 150 mm) model was virtually implanted after reaming of the medullary canal. The contact length between stem and endosteal cortex was measured, in addition to other variables. The relationship between variables was evaluated using Spearman's correlation, and logistic regression analysis was used to identify predictors of the contact length (P < .05). RESULTS: The contact length varied widely between specimens (66.5 ± 16.6 mm, range: 21-98 mm). Contact increased with the depth of the isthmus below the lesser trochanter (range: 55-155 mm; r2 = 0.473, P = .005) and the distance between the isthmus and the distal edge of the damage zone (range: -9 to 96 mm; r2 = 0.508, P = .002). Stepwise regression identified the reaming length, distance between fracture and the isthmus, and isthmus diameter as independent predictors of contact length (r = 0.643). CONCLUSIONS: Contact is limited in specimens where the isthmus is more proximally located. In these cases, supplementary fixation using plating and/or longer, curved prosthesis may be considered.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Diseño de Prótesis , Reoperación/métodos , Estudios Retrospectivos
9.
J Arthroplasty ; 36(1): 349-355, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32741712

RESUMEN

BACKGROUND: The outcome of cementless total knee arthroplasty (TKA) relies on successful bony ingrowth into the implant surfaces. Failures due to aseptic loosening are still reported, especially in younger and more active patients. The objective of this study is to quantify the micromotion of a commercially available design of cementless tibial tray under loading conditions simulating walking and stair descent. METHOD: A commercially available design of cementless total knee arthroplasty was implanted in 7 cadaveric knees which were preconditioned with 500 cycles of 0°-100° flexion under a vertical load of 1050 N in a custom-built, multiaxial functional activity simulator. This was followed by application of the peak forces and moments occurring during walking and stair descent. During each loading procedure, 3-dimensional motion at the bone-prosthesis interface was measured using digital image correlation. RESULTS: The tray migrated 101 ± 25 µm on average during preconditioning, which was dominated by rotation in the sagittal plane (92% of total migration), combined with posterior translation (28%) and minimal rotation in the transverse plane (14%). The migration varied 2.7-fold (61-167 µm) between the 6 measurement zones. Stair descent produced significantly higher total micromotion than walking in zone #5 (62 ± 9 vs 51 ± 10 µm, P < .05) and zone #6 (68 ± 17 vs 37 ± 10 µm, P < .05). In addition, during stair descent, the tray exhibited significantly more tilting (anterior zones: 31 ± 17 vs -16 ± 20 µm, P < .05; posterior zones: -60 ± 8 vs -40 ± 7 µm, P < .05) and more anteroposterior displacement in the anterior zones (-25 ± 3 vs -13 ± 2 µm, P < .05) when compared to walking. CONCLUSION: The relative motion at the bone-prosthesis interface varied substantially around the periphery of the cementless tray. Under the loading conditions evaluated, the tray primarily underwent a rocking motion in the sagittal plane. Compared with walking, stair descent produced significantly more micromotion, especially in the posterior zones.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Diseño de Prótesis , Rango del Movimiento Articular , Tibia/cirugía , Caminata
10.
J Orthop Res ; 38(8): 1779-1786, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31965588

RESUMEN

Traditional studies of hip kinematics have not identified which anatomic structures limit the range of motion (ROM) when the hip is placed in different maneuvers. In this study, we attempted to answer two questions: (a) During which maneuvers is the motion of the hip limited by bony impingement between the femur and pelvis? (b) When is hip ROM determined by the constraint of soft tissues and to what extent? ROM of eight cadaveric hips was measured in 17 maneuvers using a motion capture system. The maneuvers were recreated in silico using 3D CT models of each specimen to detect the occurrence of bony impingement. If bony impingement was not detected, the variable component of 3D hip motion was increased until a collision was detected. The difference between the virtual ROM at the point of bony impingement and the initial ROM measured experimentally was termed as the soft-tissue restriction. The results showed that bony impingement was present in normal hips during maneuvers consisting of high abduction with flexion, and high flexion combined with adduction and internal rotation. At impingement-free maneuvers, the degree of soft tissue restriction varies remarkably, ranging from 4.9° ± 3.8° (internal rotation) at 90° of flexion to 80.0° ± 12.5° (internal rotation) at maximum extension. The findings shed light on the relative contributions of osseous and soft tissues to the motion of the hip in different maneuvers and allow for a better understanding of physical exams of different purposes in diagnosing bone- or soft tissue-related diseases.


Asunto(s)
Pinzamiento Femoroacetabular/fisiopatología , Articulación de la Cadera/fisiología , Rango del Movimiento Articular , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Simulación por Computador , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Biológicos
11.
J Arthroplasty ; 35(3): 870-876, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31694778

RESUMEN

BACKGROUND: Cementless total knee arthroplasty has been developed to decrease the incidence of failure in younger and more active patients. However, failures are still more common in cementless versus cemented components. It is hypothesized that this is triggered by incomplete bone-tray contact. The present study compares the final contact area of a cementless tray as a function of the initial osteotomy flatness. METHODS: Eight surgeons prepared 14 cadaveric knees for cementless total knee replacement using standard instrumentation. The topography of each osteotomy was captured with a laser scanner; 3-dimensional computer models of the surfaces were generated. After scanning each tibia, the surgeons implanted cementless tibial trays using a manual impactor. Each tibia was then dissected, embedded in mounting resin, and sectioned. The sectioned blocks were observed under stereomicroscopy to identify points of bone-tray contact which were incorporated into the 3-dimensional models. Maps were then generated illustrating depicting contacting and noncontacting areas. RESULTS: The mean initial flatness of all specimens was 1.1 ± 0.35 mm. After impaction, 79.4% ± 0.3% of the surface had established bony contact. Of the noncontacting areas, 17.6% were within 0.3 mm of the tray. Only 2.6% of the surface was at distances reported to impede ingrowth. Noncontacting areas were typically located centrally. A trend in decreasing percent contact area with increased flatness tolerance was observed (R2 = 0.605). CONCLUSION: (1) There is an inverse correlation between the flatness of the tibial osteotomy and the percentage of the bony surface in contact with underside of the tibial tray. (2) Almost all tray-tibia contact is generated during implantation through flattening of elevated features on the tibial surface. (3) Gaps between the tray and the tibia are consistently located in the central regions of the osteotomy proximal to the medullary canal.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Articulación de la Rodilla/cirugía , Osteotomía , Tibia/cirugía
12.
J Surg Educ ; 75(3): 739-748, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29037822

RESUMEN

OBJECTIVES: Comparison of range of motion measurements by 3 types of investigators with different levels and types of training using three different measurement techniques. The study hypothesis was that the accuracy and precision of range of motion measurements would vary based on (1) the level and type of experience of the investigator and (2) the measurement technique used. DESIGN/SETTING: Descriptive laboratory study. PARTICIPANTS: Ten fresh frozen cadavers (20 upper and 20 lower extremities). INTERVENTIONS: Shoulder, elbow, hip, and knee motion were measured using 3 different measurement techniques (digital photography, goniometry, and visual estimation) by 3 groups of investigators (attending orthopedic surgeons, physical therapists, and residents). Accuracy was defined by the difference from the reference standard (motion capture analysis), whereas precision was defined by the proportion of measurements within either 5° or 10° of the reference standard. Analysis of variance, t-tests, and chi-squared tests were used. RESULTS: Statistically significant (p < 0.05) differences in accuracy were found for hip flexion, abduction, internal rotation, external rotation, and knee flexion. However, none of these differences met the authors' defined clinical significance (maximum difference 3°). Precision was significantly (p < 0.05) different for elbow extension, hip flexion, abduction, internal rotation, external rotation, and knee flexion. CONCLUSION: This study found that clinically accurate measurements of shoulder, elbow, hip, and knee motion are obtained regardless of technique used or the investigators' level and type of experience. Precision was equivalent for all shoulder motions, elbow flexion, and knee extension, but varied by as much as 7% to 28% between groups for all other motions.


Asunto(s)
Competencia Clínica , Educación de Postgrado en Medicina/métodos , Rango del Movimiento Articular/fisiología , Artrometría Articular , Cadáver , Humanos , Internado y Residencia , Extremidad Inferior/fisiología , Ortopedia/educación , Fisioterapeutas/educación , Sensibilidad y Especificidad , Extremidad Superior/fisiología
13.
J Arthroplasty ; 33(4): 1012-1018, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29195854

RESUMEN

BACKGROUND: Total joint patients are particularly vulnerable to perioperative hypothermia (PH) (combined effects of anesthesia, radiation, and convective heat loss from exposed skin surfaces and cool temperatures in the operating room). There are limited studies on PH in these patients. METHODS: In a retrospective review of 204 patients undergoing primary hip and 179 undergoing primary knee replacement surgeries, time and temperature parameters were collected from the electronic health records from preoperative and postoperative recovery room nursing assessments, intraoperative anesthesia records, and floor nursing notes. Basic patient demographic data was recorded. Chi-squared and paired t-tests were used to compare between hypothermic and normothermic groups. RESULTS: At the time of incision, 60 of 179 (34%) total knee arthroplasty (TKA) patients and 80 of 204 (39%) total hip arthroplasty (THA) patients were hypothermic. In THA patients, 65% remained hypothermic for the duration of anesthesia compared to 33% of TKA patients. The largest drop in core body temperature in both THA and TKA patients occurred between preoperative holding and induction of anesthesia. In THA patients, spinal anesthesia had a significantly higher occurrence of PH. No significant patient factor was found to increase risk. CONCLUSION: Emphasis on preoperative holding protocols, decreasing time from operating room entry to incision, and increasing ambient room temperature could reduce risk of hypothermia in total joint replacement patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Hipotermia/etiología , Anciano , Anestesia , Frío , Registros Electrónicos de Salud , Femenino , Humanos , Masculino , Persona de Mediana Edad , Quirófanos , Periodo Posoperatorio , Estudios Retrospectivos , Riesgo
14.
J Orthop Sci ; 23(2): 310-315, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29274738

RESUMEN

BACKGROUND: Accurate measurements of shoulder and elbow motion are required for the management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. METHODS: Using infrared motion capture analysis as the reference standard, shoulder flexion/abduction/internal rotation/external rotation and elbow flexion/extension were measured using visual estimation, goniometry, and digital photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard (motion capture analysis), while precision was defined by the proportion of measurements within the authors' definition of clinical significance (10° for all motions except for elbow extension where 5° was used). Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. RESULTS: Although statistically significant differences were found in measurement accuracy between the three techniques, none of these differences met the authors' definition of clinical significance. Precision of the measurements was significantly higher for both digital photography (shoulder abduction [93% vs. 74%, p < 0.001], shoulder internal rotation [97% vs. 83%, p = 0.001], and elbow flexion [93% vs. 65%, p < 0.001]) and goniometry (shoulder abduction [92% vs. 74%, p < 0.001] and shoulder internal rotation [94% vs. 83%, p = 0.008]) than visual estimation. Digital photography was more precise than goniometry for measurements of elbow flexion only [93% vs. 76%, p < 0.001]. CONCLUSIONS: There was no clinically significant difference in measurement accuracy between the three techniques for shoulder and elbow motion. Digital photography showed higher measurement precision compared to visual estimation for shoulder abduction, shoulder internal rotation, and elbow flexion. However, digital photography was only more precise than goniometry for measurements of elbow flexion. Overall digital photography shows equivalent accuracy to visual estimation and goniometry, but with higher precision than visual estimation.


Asunto(s)
Artrometría Articular/métodos , Articulación del Codo/fisiología , Fotograbar/métodos , Rango del Movimiento Articular/fisiología , Articulación del Hombro/fisiología , Cadáver , Humanos , Masculino , Sensibilidad y Especificidad
15.
J Exp Orthop ; 4(1): 29, 2017 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-28884315

RESUMEN

BACKGROUND: Accurate measurements of knee and hip motion are required for management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion at the hip and knee. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. METHODS: Using infrared motion capture analysis as the reference standard, hip flexion/abduction/internal rotation/external rotation and knee flexion/extension were measured using visual estimation, goniometry, and photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard, while precision was defined by the proportion of measurements within either 5° or 10°. Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. RESULTS: Although two statistically significant differences were found in measurement accuracy between the three techniques, neither of these differences met clinical significance (difference of 1.4° for hip abduction and 1.7° for the knee extension). Precision of measurements was significantly higher for digital photography than: (i) visual estimation for hip abduction and knee extension, and (ii) goniometry for knee extension only. CONCLUSIONS: There was no clinically significant difference in measurement accuracy between the three techniques for hip and knee motion. Digital photography only showed higher precision for two joint motions (hip abduction and knee extension). Overall digital photography shows equivalent accuracy and near-equivalent precision to visual estimation and goniometry.

16.
Knee ; 23(6): 996-1001, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28029578

RESUMEN

INTRODUCTION: Obtaining satisfactory coronal plane alignment is important for success in revision total knee arthroplasty (TKA). The study objective was to determine tibial coronal plane alignment after TKA when a tibial stem was used and assess if there was an anatomic conflict in tibial stemmed component alignment. MATERIALS AND METHODS: A radiographic review of 88 revision TKA cases was performed. Full length leg radiographs were examined for varus/valgus alignment, defined as greater than or equal to three degrees from neutral 180 degrees, canal or non-canal filling tibial stems, and any native tibial bow. RESULTS: In tibias with a native valgus alignment of three or more degrees, a canal-filling stem allowed little flexibility to improve final positioning of the tibial stem and resulted in a valgus alignment of the tibial stem in 87.5% of cases, where a canal filling stem was utilized. A non-canal filling stem utilized in native valgus tibias allowed on average a two-degree improvement in tibial alignment and 64.7% of cases resulted in a neutral placement of the tibial stem. CONCLUSION: Implanting the tibial component in a desired position is limited by type of stem and the native angulation of the tibia. When anatomic conflict exists between tibial mechanical axis and the intramedullary canal, canal filling stems may compromise coronal alignment.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Desviación Ósea/prevención & control , Prótesis de la Rodilla , Tibia/cirugía , Desviación Ósea/diagnóstico por imagen , Humanos , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Tibia/diagnóstico por imagen
17.
J Arthroplasty ; 31(9 Suppl): 59-62, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27262420

RESUMEN

BACKGROUND: The objectives of this study were to quantify increased utilization of resources in revision total knee arthroplasty (TKA) compared with primary TKA, determine preoperative factors that predict outcome measures, and compare Medicare reimbursement for each procedure. METHODS: Seventy-eight revision TKA patients were compared with 80 primary TKA patients. Outcomes measured were surgical time, estimated blood loss, length of stay, and complications. RESULTS: Revision TKA showed 49% increased surgical time compared with primary TKA. Estimated blood loss was increased 91%. Tibial and femoral bone loss was associated with increased surgical time as was use of longer stemmed tibial components. Average Medicare hospital payment increased 29% ($13,464 for primary, $17,331 for revision). Average physician reimbursement represented a 36% increase. Relative value units were increased to 31%. CONCLUSION: There was substantial increase in work effort not commensurate with current Medicare reimbursement, which may limit patient access to revision TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Tempo Operativo , Reoperación/métodos , Cirujanos , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Femenino , Costos de la Atención en Salud , Recursos en Salud , Hospitales , Humanos , Tiempo de Internación , Masculino , Medicare , Persona de Mediana Edad , Mecanismo de Reembolso , Tibia , Estados Unidos
18.
J Arthroplasty ; 31(6): 1188-1193, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26777577

RESUMEN

BACKGROUND: Primary total hip arthroplasties (THAs) performed annually are projected to increase 174% by 2030, causing a parallel increase for revision THA. Increased surgical effort and readmission rates associated with revision THA may discourage surgeons from performing them. Although revision THA Medicare reimbursement is greater, it may be disproportionate to time and effort. We examined work input between primary and revision THA, assessing predictive factors. We also compared surgeon work input to current reimbursement. METHODS: A total of 156 patients were identified, 80 primary and 76 revision THA. Demographic, clinical, and radiographic data were collected. Radiographic data were collected from the most recent preoperative radiographs taken before primary or revision THA. Multiple linear and logistic regression models were used to identify patient factors contributing to select outcome variables by a stepwise method, with a probability value for entry (P = .05) and removal (P = .10). Residual analysis was performed, confirming validity of these models. RESULTS: Average age, body mass index, and percentage of female patients were similar between cohorts. There was no statistically significant difference between the demographic variables, although data revealed patient variables contributing to statistically significant increases in surgical time, length of stay, blood loss, and complications with revision THA. CONCLUSION: Despite a 66% increase in "percent effort" and 3-fold higher readmission rate, revision THA requires at least a 2-fold increase because of nonquantifiable factors. Revision THA demonstrates a substantial increase in work effort not commensurate with current Medicare reimbursement, which may force surgeons to limit or eliminate revision arthroplasties performed reducing access to patient care.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Reoperación/métodos , Cirujanos , Anciano , Artroplastia de Reemplazo de Cadera/economía , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Estudios de Cohortes , Femenino , Accesibilidad a los Servicios de Salud , Humanos , Masculino , Medicare , Persona de Mediana Edad , Tempo Operativo , Readmisión del Paciente/economía , Readmisión del Paciente/legislación & jurisprudencia , Readmisión del Paciente/estadística & datos numéricos , Mecanismo de Reembolso , Reoperación/economía , Reoperación/estadística & datos numéricos , Resultado del Tratamiento , Estados Unidos
19.
J Arthroplasty ; 30(11): 2012-6, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26021905

RESUMEN

This study was performed to study the relationship between the degree of varus deformity of osteoarthritic knees and the anatomic distribution of cartilage pathology. Bone wafers resected from the distal femur and proximal tibia were obtained from 107 patients (195 knees) with primary varus osteoarthritis. Severity and distribution of joint damage was scored for each articular surface and related to potential prognostic factors, including varus deformity, the ligamentous status of the knee, age, gender and BMI. There was highly significant association between varus angulation of the knee and the total damage score for the tibia (P=0.001), but not the femur (P=0.2947). The degree of deformity, and not the status of the ACL alone, determines wear pattern and provides insight for preoperative planning of TKA.


Asunto(s)
Anteversión Ósea/fisiopatología , Articulación de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/fisiopatología , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla , Anteversión Ósea/patología , Femenino , Fémur/patología , Fémur/cirugía , Humanos , Articulación de la Rodilla/patología , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/patología , Osteoartritis de la Rodilla/cirugía , Estudios Prospectivos , Tibia/patología , Tibia/cirugía
20.
Arthroscopy ; 28(10): 1481-9, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22796141

RESUMEN

PURPOSE: To evaluate knee stability after anterior cruciate ligament (ACL) reconstruction using 2 modern clinically relevant single-bundle constructs. METHODS: Two arthroscopic ACL reconstructions were performed on 6 fresh-frozen human cadaveric knees using bone-patellar tendon-bone autografts. The tibial tunnel was centered in the anatomic tibial footprint. The femoral tunnel was reamed through the anteromedial (AM) portal and centered alternately in either the AM portion of the femoral footprint (center-AM) or the center of the femoral footprint (center-center). Two external loading conditions were applied: (1) a 134-N anterior tibial load and (2) a 10-Nm valgus load combined with a 5-Nm internal tibial torque. Resulting kinematics were determined under 4 conditions: (1) ACL intact, (2) ACL deficient, (3) center-AM reconstruction, and (4) center-center reconstruction. RESULTS: In response to anterior tibial loading, anterior translation was similar in the ACL-intact knee and the 2 reconstructions at 0° to 60° of flexion but was greater in the reconstructed specimens at 90°. In response to the complex rotatory load, internal tibial rotation (ITR) at 30° of flexion was slightly greater in center-AM knees compared with ACL-intact knees (11.0° ± 0.6° v 10.5° ± 0.6°, P = .03). At other angles tested, ITR in both reconstructions was similar to the ACL-intact knee (P > .05). When we compared the 2 reconstruction alternatives, however, center-center knees exhibited greater resistance to ITR at all angles (P < .05). CONCLUSION: Anatomic single-bundle ACL reconstruction performed with the femoral tunnel placed through the AM portal restores translational and rotational knee stability to an extent that closely approximates the ACL-intact condition. When compared with the AM femoral tunnel position, a femoral tunnel positioned in the anatomic center of the femoral origin of the ACL may further improve rotatory stability without sacrificing anterior stability. CLINICAL RELEVANCE: This study provides additional biomechanical evidence in support of anatomic single-bundle ACL reconstruction with tunnels positioned in the center of the femoral and tibial footprints.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirugía , Fémur/cirugía , Articulación de la Rodilla/fisiopatología , Adulto , Anciano , Fenómenos Biomecánicos , Plastía con Hueso-Tendón Rotuliano-Hueso , Cadáver , Fémur/fisiopatología , Humanos , Inestabilidad de la Articulación/cirugía , Persona de Mediana Edad , Rotación , Tibia/fisiopatología , Tibia/cirugía