1.
Methods Mol Biol ; 2817: 19-31, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38907144

RESUMEN

Clinical and biological samples are often scarce and precious (e.g., rare cell isolates, microneedle tissue biopsies, small-volume liquid biopsies, and even single cells or organelles). Typical large-scale proteomic methods, where significantly higher protein amounts are analyzed, are not directly transferable to the analysis of limited samples due to their incompatibility with pg-, ng-, and low-µg-level protein sample amounts. Here, we report the on-microsolid-phase extraction tip (OmSET)-based sample preparation workflow for sensitive analysis of limited biological samples to address this challenge. The developed platform was successfully tested for the analysis of 100-10,000 typical mammalian cells and is scalable to allow for lower and larger protein amounts and more samples to be analyzed (i.e., higher throughput of analysis).


Asunto(s)
Proteómica , Extracción en Fase Sólida , Flujo de Trabajo , Proteómica/métodos , Humanos , Extracción en Fase Sólida/métodos , Proteínas/análisis , Proteoma/análisis
2.
J Extracell Biol ; 3(3)2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38751711

RESUMEN

Extracellular vesicles (EVs) play a pivotal role in various biological pathways, such as immune responses and the progression of diseases, including cancer. However, it is challenging to isolate EVs at high purity from blood plasma and other biofluids due to their low abundance compared to more predominant biomolecular species such as lipoprotein particles and free protein complexes. Ultracentrifugation-based EV isolation, the current gold standard technique, cannot overcome this challenge due to the similar biophysical characteristics of such species. We developed several novel approaches to enrich EVs from plasma while depleting contaminating molecular species using multimode chromatography-based strategies. On average, we identified 716 ± 68 and 1054 ± 35 protein groups in EV isolates from 100 µL of plasma using multimode chromatography- and ultracentrifugation-based techniques, respectively. The developed methods resulted in similar EV isolates purity, providing significant advantages in simplicity, throughput, scalability, and applicability for various downstream analytical and potential clinical applications.

3.
Nat Commun ; 15(1): 3847, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38719792

RESUMEN

The development of reliable single-cell dispensers and substantial sensitivity improvement in mass spectrometry made proteomic profiling of individual cells achievable. Yet, there are no established methods for single-cell glycome analysis due to the inability to amplify glycans and sample losses associated with sample processing and glycan labeling. In this work, we present an integrated platform coupling online in-capillary sample processing with high-sensitivity label-free capillary electrophoresis-mass spectrometry for N-glycan profiling of single mammalian cells. Direct and unbiased quantitative characterization of single-cell surface N-glycomes are demonstrated for HeLa and U87 cells, with the detection of up to 100 N-glycans per single cell. Interestingly, N-glycome alterations are unequivocally detected at the single-cell level in HeLa and U87 cells stimulated with lipopolysaccharide. The developed workflow is also applied to the profiling of ng-level amounts (5-500 ng) of blood-derived protein, extracellular vesicle, and total plasma isolates, resulting in over 170, 220, and 370 quantitated N-glycans, respectively.


Asunto(s)
Electroforesis Capilar , Glicómica , Espectrometría de Masas , Polisacáridos , Análisis de la Célula Individual , Humanos , Electroforesis Capilar/métodos , Polisacáridos/metabolismo , Polisacáridos/sangre , Análisis de la Célula Individual/métodos , Células HeLa , Espectrometría de Masas/métodos , Glicómica/métodos , Proteómica/métodos , Vesículas Extracelulares/metabolismo , Lipopolisacáridos , Proteínas Sanguíneas/análisis , Proteínas Sanguíneas/metabolismo
4.
J Proteome Res ; 23(6): 2230-2240, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38690845

RESUMEN

Deep proteomic profiling of complex biological and medical samples available at low nanogram and subnanogram levels is still challenging. Thorough optimization of settings, parameters, and conditions in nanoflow liquid chromatography-tandem mass spectrometry (MS)-based proteomic profiling is crucial for generating informative data using amount-limited samples. This study demonstrates that by adjusting selected instrument parameters, e.g., ion injection time, automated gain control, and minimally altering the conditions for resuspending or storing the sample in solvents of different compositions, up to 15-fold more thorough proteomic profiling can be achieved compared to conventionally used settings. More specifically, the analysis of 1 ng of the HeLa protein digest standard by Q Exactive HF-X Hybrid Quadrupole-Orbitrap and Orbitrap Fusion Lumos Tribrid mass spectrometers yielded an increase from 1758 to 5477 (3-fold) and 281 to 4276 (15-fold) peptides, respectively, demonstrating that higher protein identification results can be obtained using the optimized methods. While the instruments applied in this study do not belong to the latest generation of mass spectrometers, they are broadly used worldwide, which makes the guidelines for improving performance desirable to a wide range of proteomics practitioners.


Asunto(s)
Proteómica , Espectrometría de Masas en Tándem , Proteómica/métodos , Humanos , Espectrometría de Masas en Tándem/métodos , Células HeLa , Cromatografía Liquida/métodos , Proteoma/análisis , Péptidos/análisis , Péptidos/química
5.
Cell Rep Methods ; 4(2): 100717, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38412830

RESUMEN

Method development for mass spectrometry (MS)-based thermal shift proteomic assays have advanced to probe small molecules with known and unknown protein-ligand interaction mechanisms and specificity, which is predominantly used in characterization of drug-protein interactions. In the discovery of target and off-target protein-ligand interactions, a thorough investigation of method development and their impact on the sensitivity and accuracy of protein-small molecule and protein-protein interactions is warranted. In this review, we discuss areas of improvement at each stage of thermal proteome profiling data analysis that includes processing of MS-based data, method development, and their effect on the overall quality of thermal proteome profiles. We also overview the optimization of experimental strategies and prioritization of an increased number of independent biological replicates over the number of evaluated temperatures.


Asunto(s)
Proteoma , Proteómica , Proteoma/análisis , Proteómica/métodos , Ligandos , Espectrometría de Masas/métodos , Análisis de Datos
6.
Mol Omics ; 20(3): 184-191, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38353725

RESUMEN

Nanoflow liquid chromatography-mass spectrometry is key to enabling in-depth proteome profiling of trace samples, including single cells, but these separations can lack robustness due to the use of narrow-bore columns that are susceptible to clogging. In the case of single-cell proteomics, offline cleanup steps are generally omitted to avoid losses to additional surfaces, and online solid-phase extraction/trap columns frequently provide the only opportunity to remove salts and insoluble debris before the sample is introduced to the analytical column. Trap columns are traditionally short, packed columns used to load and concentrate analytes at flow rates greater than those employed in analytical columns, and since these first encounter the uncleaned sample mixture, trap columns are also susceptible to clogging. We hypothesized that clogging could be avoided by using large-bore porous layer open tubular trap columns (PLOTrap). The low back pressure ensured that the PLOTraps could also serve as the sample loop, thus allowing sample cleanup and injection with a single 6-port valve. We found that PLOTraps could effectively remove debris to avoid column clogging. We also evaluated multiple stationary phases and PLOTrap diameters to optimize performance in terms of peak widths and sample loading capacities. Optimized PLOTraps were compared to conventional packed trap columns operated in forward and backflush modes, and were found to have similar chromatographic performance of backflushed traps while providing improved debris removal for robust analysis of trace samples.


Asunto(s)
Cromatografía Líquida con Espectrometría de Masas , Proteómica , Proteómica/métodos , Cromatografía Liquida
7.
J Extracell Vesicles ; 13(2): e12404, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38326288

RESUMEN

Extracellular vesicles (EVs), through their complex cargo, can reflect the state of their cell of origin and change the functions and phenotypes of other cells. These features indicate strong biomarker and therapeutic potential and have generated broad interest, as evidenced by the steady year-on-year increase in the numbers of scientific publications about EVs. Important advances have been made in EV metrology and in understanding and applying EV biology. However, hurdles remain to realising the potential of EVs in domains ranging from basic biology to clinical applications due to challenges in EV nomenclature, separation from non-vesicular extracellular particles, characterisation and functional studies. To address the challenges and opportunities in this rapidly evolving field, the International Society for Extracellular Vesicles (ISEV) updates its 'Minimal Information for Studies of Extracellular Vesicles', which was first published in 2014 and then in 2018 as MISEV2014 and MISEV2018, respectively. The goal of the current document, MISEV2023, is to provide researchers with an updated snapshot of available approaches and their advantages and limitations for production, separation and characterisation of EVs from multiple sources, including cell culture, body fluids and solid tissues. In addition to presenting the latest state of the art in basic principles of EV research, this document also covers advanced techniques and approaches that are currently expanding the boundaries of the field. MISEV2023 also includes new sections on EV release and uptake and a brief discussion of in vivo approaches to study EVs. Compiling feedback from ISEV expert task forces and more than 1000 researchers, this document conveys the current state of EV research to facilitate robust scientific discoveries and move the field forward even more rapidly.


Asunto(s)
Exosomas , Vesículas Extracelulares , Vesículas Extracelulares/metabolismo , Exosomas/metabolismo , Transporte Biológico , Biomarcadores/metabolismo , Fenotipo
8.
Adv Sci (Weinh) ; 11(11): e2306824, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38191978

RESUMEN

Protein complexes are essential for proteins' folding and biological function. Currently, native analysis of large multimeric protein complexes remains challenging. Structural biology techniques are time-consuming and often cannot monitor the proteins' dynamics in solution. Here, a capillary electrophoresis-mass spectrometry (CE-MS) method is reported to characterize, under near-physiological conditions, the conformational rearrangements of ∽1 MDa GroEL upon complexation with binding partners involved in a protein folding cycle. The developed CE-MS method is fast (30 min per run), highly sensitive (low-amol level), and requires ∽10 000-fold fewer samples compared to biochemical/biophysical techniques. The method successfully separates GroEL14 (∽800 kDa), GroEL7 (∽400 kDa), GroES7 (∽73 kDa), and NanA4 (∽130 kDa) oligomers. The non-covalent binding of natural substrate proteins with GroEL14 can be detected and quantified. The technique allows monitoring of GroEL14 conformational changes upon complexation with (ATPγS)4-14 and GroES7 (∽876 kDa). Native CE-pseudo-MS3 analyses of wild-type (WT) GroEL and two GroEL mutants result in up to 60% sequence coverage and highlight subtle structural differences between WT and mutated GroEL. The presented results demonstrate the superior CE-MS performance for multimeric complexes' characterization versus direct infusion ESI-MS. This study shows the CE-MS potential to provide information on binding stoichiometry and kinetics for various protein complexes.


Asunto(s)
Pliegue de Proteína , Proteínas , Conformación Proteica , Electroforesis Capilar , Espectrometría de Masas
SELECCIÓN DE REFERENCIAS