Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Appl Radiat Isot ; 170: 109559, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33476941

RESUMEN

From a commercial supplier, three independent lots of an aqueous solution containing 223Ra in equilibrium with its deteriorating progeny were considered for standardization, by using live-time anticoincidence counting (LTAC) in the Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI) Brazil. The ionization chamber calibration factors were obtained using measurements of independent lots of 223Ra in LTAC considering the absolute method in order to evaluate the constancy and reproducibility of the standardization. The calibration factors of three high-performance well-type ionization chamber systems and four commercial well-type ionization chambers were determined. The LTAC results showed that lots 2 and 3 were 1069.88 and 1097.44 kBq/kg, with corresponding relative standard uncertainties 0.12% and 0.20%, respectively. The spectrometry method results of each lot value were classified as positive by ANOVA hypothesis testing. The emission probabilities relating to the X- and γ-rays in region from 81 to 830 keV ware determined. Hence, LNMRI can provide calibration services for 223Ra.

2.
J Nutr Health Aging ; 24(8): 878-882, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33009539

RESUMEN

AIM: This is a cross-sectional study of relation between metabolic syndrome and cognitive function in community-dwelling non-demented older adults in Japan. We examine the effect of metabolic syndrome and its components on global cognitive function. We also aim to clarify differences of specific cognitive domains between the subjects with and without metabolic syndrome. METHODS: We studied 2150 subjects aged between 60 and 90 years whose scores on mini mental state examination (MMSE) were over 23 points. We analyzed difference in MMSE scores between the subjects with and without metabolic syndrome. Logistic regression analysis was performed with MMSE score as the dependent variable and metabolic syndrome components as the independent variable adjusted with age. We also examined differences in attention, logical memory, and verbal and category fluency between the subjects with and without metabolic syndrome. RESULTS: MMSE scores were not significantly different between subjects with and without metabolic syndrome. In logistic regression analysis, the score of MMSE was significantly negatively associated with triglycerides in males and significantly negatively associated with abdominal circumference in females. Subjects with metabolic syndrome showed significantly lower performance of attention tasks compared to subjects without metabolic syndrome. CONCLUSIONS: Our results suggest that in community-dwelling non-demented Japanese older adults, attention but not global cognitive function may be impaired by metabolic syndrome. Inverted association between some components of metabolic syndrome and global cognitive function indicate necessity of further studies on the relation between undernutrition and cognitive function.


Asunto(s)
Cognición/fisiología , Síndrome Metabólico/epidemiología , Anciano , Anciano de 80 o más Años , Estudios Transversales , Femenino , Humanos , Vida Independiente , Japón , Masculino
3.
Appl Radiat Isot ; 166: 109323, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32795698

RESUMEN

There are few long-lived radionuclides yielding high intensity gamma-rays emission with energies ranging from 100 keV to 500 keV that can be applied as radioactive gamma standard to calibrate HPGe detectors. Furthermore, this energy range represents the main emitted energies of the majority of radionuclides used in nuclear medicine. The Brazilian National Laboratory for Ionizing Radiation Metrology (LNMRI/IRD/CNEN) has attempted to identify radionuclides that have the potential to be used as a calibration source due to their long half-life as well as their emission spectrum. Hence, LNMRI promotes standardization studies of gamma-emitting radionuclides that meet these criteria on order to disseminate them. Thorium-229, with its well-defined energies and relatively high intensities, is one such candidate radionuclide for the energy and full-energy peak efficiency calibration of high-purity gamma spectrometers. Thorium-229 was standardized by the method of 4παß(LS)-γ(NaI(Tl)) live timed anticoincidence counting. The emission intensities of gamma-rays associated with the decay of 229Th have been determined by HPGe gamma ray spectrometry with accuracy and precision. The results are in agreement with current literature data.

4.
Appl Radiat Isot ; 134: 64-67, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28942991

RESUMEN

Traceability in Nuclear Medicine Service (NMS) measurements was checked by the Institute of Radioprotection and Dosimetry (IRD) through the Institute of Energy and Nuclear Research (IPEN). In 2016, IRD ran an intercomparison program and invited Brazilian NMS authorized to administer 131I to patients. Sources of 131I were distributed to 33 NMSs. Three other sources from the same solution were sent to IRD, after measurement at IPEN. These sources were calibrated in the IRD reference system. A correction factor of 1.013 was obtained. Ninety percent of the NMS comparisons results are within ±10% of the National Laboratory of Metrology of Ionizing Radiation (LNMRI) value, the Brazilian legal requirement.


Asunto(s)
Instituciones de Atención Ambulatoria , Radioisótopos de Yodo/análisis , Servicio de Medicina Nuclear en Hospital , Radiofármacos/análisis , Brasil , Calibración , Competencia Profesional , Control de Calidad , Reproducibilidad de los Resultados , Factores de Tiempo , Incertidumbre
5.
Appl Radiat Isot ; 134: 316-320, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29107514

RESUMEN

From a commercial supplier a solution containing 134Cs has been standardized at National Laboratory for Ionizing Radiation Metrology (LNMRI) for the first time using three Liquid scintillation based measurement. These measurement methods are 4πß-γ live-timed anticoincidence counting, 4πß-γ coincidence counting and 3H-standard efficiency tracing with the CNET methods. The results obtained by anticoincidence counting was adopted as reference value and its combined uncertainty was 0.38%. The agreement of this reference value with coincidence counting and CNET methods were 0.39% and 0.34% respectively and were in consistency with each uncertainty method. The weighted mean results coincidence counting and CNET methods are also in close agreement 0.03% with anticoincidence counting method and meets the requirement of primary and national standard. This standardization was made in order to reduce the uncertainty in 134Cs measurement in Brazil and also following a request made by Bureau International des Poids and Mesures for new submission to International Reference System. The LNMRI last submission was made in 1987. Therefore from a 134Cs master solution a NIST ampoules was prepared and LNMRI/IRD submitted it to the International Reference System, Bureau International of Poids and Measures (SIR/BIPM). In this paper will be analyzed the LNMRI measurement and performance each measurement methods and also take into account the reference value of KCDB, we determined also the 134Cs gamma emission probabilities of main energy.

6.
Appl Radiat Isot ; 134: 307-311, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29153654

RESUMEN

In this work, a 68(Ge+Ga) solution has been standardized at the National Institute of Ionizing Radiation Metrology (LNMRI), in Brazil, in the frame of an international key comparison CCRI(II)-K2.Ge-68 piloted by National Institute of Standards and Technology (NIST/USA). The 4πß(LS)-γ(NaI(Tl)) anticoincidence method with live-time and extended dead-time was used and its result was validated by 4πß(LS)-γ(NaI(Tl)) coincidence counting and liquid scintillation counting using the Triple to Double Coincidence Ratio (TDCR) method. The deviations of the activity concentration values of coincidence and TDCR measurements from the anticoincidence result were 1.7% and 0.63%, respectively, which were within experimental evaluated uncertainties at ~95% level of confidence (coverage factor k = 2). The combined relative standard uncertainties were 0.65%, 0.70% and 0.53% for anticoincidence, coincidence and TDCR methods, respectively. These values are consistent with the results reported by Cessna at the ICRM2017 conference.

7.
Appl Radiat Isot ; 134: 385-390, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29248210

RESUMEN

An international key comparison, identifier CCRI(II)-K2.Ge-68, has been performed. The National Institute of Standards and Technology (NIST) served as the pilot laboratory, distributing aliquots of a 68Ge/68Ga solution. Results for the activity concentration, CA, of 68Ge at a reference date of 12h00 UTC 14 November 2014 were submitted by 17 laboratories, encompassing many variants of coincidence methods and liquid-scintillation counting methods. The first use of 4π(Cherenkov)ß-γ coincidence and anticoincidence methods in an international comparison is reported. One participant reported results by secondary methods only. Two results, both utilizing pure liquid-scintillation methods, were identified as outliers. Evaluation using the Power-Moderated Mean method results in a proposed Comparison Reference Value (CRV) of 621.7(11)kBqg-1, based on 14 results. The degrees of equivalence and their associated uncertainties are evaluated for each participant. Several participants submitted 3.6mL ampoules to the BIPM to link the comparison to the International Reference System (SIR) which may lead to the evaluation of a Key Comparison Reference Value and associated degrees of equivalence.

8.
Appl Radiat Isot ; 122: 37-40, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28092780

RESUMEN

The absolute activity standardization measurement system of radionuclide by live-timed anticoincidence counting was implemented at LNMRI in 2008 to reduce the effects of some correction factors on the determination of activity with coincidence counting technique used for decades in the laboratory, for example, the corrections of dead time and resolution. With the live-timed anticoincidence system, the variety of radionuclides that can be calibrated by LNMRI was increased in relation to the type of decay. The objective of this study was to standardize the 106Ru activity, determine gamma emission probabilities by spectrometric method for some energies, and estimate measurement uncertainties.

9.
Appl Radiat Isot ; 109: 389-392, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26805708

RESUMEN

(123)I is widely used for radiodiagnostic procedures. It is produced by reaction of (124)Xe (p,2n) (123)Cs →(123)Xe →(123)I in cyclotrons. (121)Te and (125)I appear in a photon energy spectrum as impurities. An activity of (121)Te was calibrated absolutely by sum-peak method and its photon emitting probability was estimated, whose results were consistent with published results.

10.
Appl Radiat Isot ; 109: 236-241, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26688362

RESUMEN

Since the inception of its proficiency test program to evaluate radionuclide measurement in hospitals and clinics, the National Metrology Laboratory of Ionizing Radiation-LNMRI, that represents Brazilian National Metrology Institute (NMI) for ionizing radiation has expanded its measurement and calibration capability. Requirements from the National Health Surveillance Agency from Ministry of Health (ANVISA), to producers of radiopharmaceuticals provided an opportunity to improve the full traceability chain to the highest level. Fluorodeoxyglucose (FDG-(18)F) is the only radiopharmaceutical simultaneously produced by all Brazilian radiopharmaceutical production centers (RPCs). By running this proficiency test, LNMRI began to provide them with the required traceability. For evaluation, the ratio of RPC to reference value results and ISO/IEC17043:2010 criteria were used. The reference value established as calibration factor on the secondary standard ionization chamber was obtained from three absolute measurements systems, and routinely confirmed in each round of proficiency test by CIEMAT/NIST liquid scintillation counting. The γ-emitting impurities were checked using a High-Purity Germanium (HPGe) detector. The results show that Brazilian RPCs are in accordance with (accuracy within ±10%) the Brazilian standard for evaluation of measurements with radionuclide calibrators (CNEN NN 3.05., 2013). Nevertheless, the RPCs should improve the methodology of uncertainty estimates, essential when using the statistical criteria of ISO/IEC 17043 standard, in addition to improving accuracy to levels consistent with their position in the national traceability chain.


Asunto(s)
Radioisótopos de Flúor/análisis , Radioisótopos de Flúor/normas , Sector Público/normas , Radiometría/métodos , Radiometría/normas , Brasil , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Appl Radiat Isot ; 87: 188-91, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24361323

RESUMEN

In order to maintain the results of primary activity standardizations carried out in 2011 the LNMRI has determined the calibration factors for a pressurized 4π-ionization chamber for the nuclides (18)F and (68)Ga. This ionization chamber is coupled to a 6517A Keithley electrometer which is controlled by a homemade LabVIEW program. This paper will describe the main issues related to the calibration of an ionization chamber system for positron emitters and short half-life radionuclides such as timing, current measurement, background, decay, and (226)Ra check source measurements.

12.
Appl Radiat Isot ; 70(9): 2056-9, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22417696

RESUMEN

The National Laboratory for Metrology of Ionizing Radiation (LNMRI)/Brazil acquired (166m)Ho and (243)Am/(239)Np solutions from commercial suppliers in order to realize primary standardization and therefore reducing the associated uncertainties. The method used in the standardization was the live-timed 4πß(LS)-γ(ΝaI(Tl)) anticoincidence counting. The live-timed anticoincidence system is operated since 2006 in LNMRI and is composed of two MTR2 modules donated by Laboratoire National Henri Becquerel (LNE-LNHB)/France. The data acquisition system uses a homemade LabView program and an Excel file for calculus. These systems have been used for primary standardization at LNMRI for many radionuclides and recently took part in the (124)Sb and (177)Lu International Key Comparisons with good performance.


Asunto(s)
Americio/análisis , Americio/normas , Holmio/normas , Neptunio/análisis , Neptunio/normas , Radiometría/normas , Programas Informáticos/normas , Americio/química , Brasil , Semivida , Holmio/análisis , Internacionalidad , Lenguajes de Programación , Dosis de Radiación , Estándares de Referencia , Valores de Referencia
13.
Appl Radiat Isot ; 70(9): 1924-6, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22406221

RESUMEN

The National Laboratory for Metrology of Ionizing Radiation (LNMRI)/Brazil participated in the last (57)Co activity measurement comparison organized by IAEA, in 2008. This was made in order to realize primary standardization of this radionuclide and to reduce the measuring uncertainties in the laboratory. Additionally, one sample with 2.6g was taken from the IAEA master solution of (57)Co and was prepared to be used in the measurement of the radionuclide's half-life in an ionization chamber system. The (57)Co half-life was measured to be 271.82 (17) days.


Asunto(s)
Radioisótopos de Cobalto/análisis , Radioisótopos de Cobalto/química , Radiometría/instrumentación , Radiometría/normas , Brasil , Semivida , Internacionalidad , Dosis de Radiación , Estándares de Referencia , Valores de Referencia
14.
Appl Radiat Isot ; 70(9): 2087-90, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22425414

RESUMEN

A commercial solution of (65)Zn was standardized by the sum peak-method using a planar HPGe detector. The activity results were compared with measurements made with a well type 4πγ ionization chamber, which is traceable to BIPM.RI (II)-K2.Zn-65 key-comparison performed in 2002. The sum-peak value was 42.79 kBq/g and the ionization chamber value was 42.74 kBq/g both at the reference date. The uncertainty obtained in the sum peak standardization was 0.25% (k=1), and in the ionization chamber was 0.85% (k=1). The results showed that sum-peak method can be used in (65)Zn standardization and this method is easier, simpler and more practical than others methods.


Asunto(s)
Algoritmos , Radioisótopos/análisis , Radioisótopos/normas , Radiometría/instrumentación , Radiometría/normas , Radioisótopos de Zinc/análisis , Radioisótopos de Zinc/normas , Semivida , Internacionalidad , Dosis de Radiación , Radioisótopos/química , Estándares de Referencia , Valores de Referencia , Semiconductores , Radioisótopos de Zinc/química
15.
Appl Radiat Isot ; 70(9): 1825-30, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22445396

RESUMEN

An international Key Comparison of (177)Lu has recently been carried out. Twelve laboratories performed assays for radioactivity content on aliquots of a common master solution of (177)Lu, leading to eleven results submitted for entry into the Key Comparison Database of the Mutual Recognition Arrangement. A proposed Comparison Reference Value (CRV) was calculated to be 3.288(4)MBq/g using all eleven results. Degrees of equivalence and their uncertainties were calculated for each laboratory based on the CRV. Most of the values reported by the participating laboratories were within 0.6% of the CRV.


Asunto(s)
Lutecio/análisis , Lutecio/química , Radioisótopos/análisis , Radioisótopos/química , Radiometría/instrumentación , Radiometría/normas , Lutecio/normas , Dosis de Radiación , Radioisótopos/normas , Estándares de Referencia , Valores de Referencia
16.
Appl Radiat Isot ; 70(9): 2081-6, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22401938

RESUMEN

The activities of (177)Lu, (111)In and (123)I solutions have been absolutely determined using three different measurement methods. (177)Lu solution was standardized using the 4πß(PC)-γ(NaI) coincidence and 4πß(LS)-γ(NaI) live-timed anticoincidence methods. For the (111)In and (123)I solutions, besides these two mentioned methods, the coincidence sum-peak method was also applied. The measured activities results using these different methods are consistent within the evaluated experimental uncertainties demonstrating the equivalence of these methods. As an additional contribution to nuclear data, the half-lives have been determined using a well type IG12 ionization chamber.


Asunto(s)
Radioisótopos/análisis , Radioisótopos/normas , Radiometría/instrumentación , Radiometría/normas , Semivida , Internacionalidad , Dosis de Radiación , Radioisótopos/química , Estándares de Referencia , Valores de Referencia
17.
Appl Radiat Isot ; 68(7-8): 1207-10, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20153206

RESUMEN

An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories. In order to identify possible biases, the participants were asked to use all possible activity measurement methods available in their laboratory and then to determine their reference value for comparison. Thus, measurement results from 4pibeta-gamma coincidence/anti-coincidence counting, CIEMAT/NIST liquid-scintillation counting, 4pigamma counting with well-type ionization chambers and well-type crystal detectors were given. The results are compared and show a maximum discrepancy of about 1.6%: possible explanations are proposed.


Asunto(s)
Antimonio/análisis , Antimonio/normas , Cooperación Internacional , Fotones , Valores de Referencia , Reproducibilidad de los Resultados , Conteo por Cintilación , Soluciones , Pesos y Medidas
18.
Appl Radiat Isot ; 68(10): 2026-30, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20171111

RESUMEN

An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories, six of which sent results for photon emission intensities both in absolute and in relative terms. From these results and including previous published values, a consistent decay scheme was worked out, proving that problems in activity measurements have not been due to decay scheme data.

19.
Appl Radiat Isot ; 67(10): 1887-91, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19505830

RESUMEN

The sum-peak method was applied to standardize a (57)Co solution within the framework of an international comparison organized by International Atomic Energy Agency, in 2008, aimed toward international traceability of activity measurements. A planar germanium detector was used with the sources placed on top of the detector for activity determination measurements. An analytical expression for accidental summing correction was derived and the effect of the germanium characteristic KX-ray escape peak of 112keV was taken into account. The standard uncertainty associated to the activity concentration value was 0.37% and the result was compared with other measurement methods.

20.
Appl Radiat Isot ; 66(6-7): 886-9, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18356060

RESUMEN

The National Metrology Laboratory for Ionizing Radiation (LNMRI)/Brazil has implemented a live-timed anti-coincidence system with extending dead time to complement the existing systems in its Radionuclide Laboratory for activity measurements of radioactive sources. In this new system, the proportional counter has been replaced by a liquid-scintillation-counter for alpha and beta detection. In order to test the performance of the new system, radioactive solutions of (131)I, (124)Sb and (241)Am have been standardized. In this work the measurement method, the results and the associated uncertainties are described and discussed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...