Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
BMC Plant Biol ; 24(1): 504, 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38840239

RESUMEN

The domestication process in grapevines has facilitated the fixation of desired traits. Nowadays, vegetative propagation through cuttings enables easier preservation of these genotypes compared to sexual reproduction. Nonetheless, even with vegetative propagation, various phenotypes are often present within the same vineyard due to the accumulation of somatic mutations. These mutations are not the sole factors influencing phenotype. Alongside somatic variations, epigenetic variation has been proposed as a pivotal player in regulating phenotypic variability acquired during domestication. The emergence of these epialleles might have significantly influenced grapevine domestication over time. This study aims to investigate the impact of domestication on methylation patterns in cultivated grapevines. Reduced-representation bisulfite sequencing was conducted on 18 cultivated and wild accessions. Results revealed that cultivated grapevines exhibited higher methylation levels than their wild counterparts. Differential Methylation Analysis between wild and cultivated grapevines identified a total of 9955 differentially methylated cytosines, of which 78% were hypermethylated in cultivated grapevines. Functional analysis shows that core methylated genes (consistently methylated in both wild and cultivated accessions) are associated with stress response and terpenoid/isoprenoid metabolic processes. Meanwhile, genes with differential methylation are linked to protein targeting to the peroxisome, ethylene regulation, histone modifications, and defense response. Collectively, our results highlight the significant roles that epialleles may have played throughout the domestication history of grapevines.


Asunto(s)
Productos Agrícolas , Metilación de ADN , Domesticación , Epigénesis Genética , Vitis , Vitis/genética , Productos Agrícolas/genética , Productos Agrícolas/crecimiento & desarrollo , Fenotipo
2.
An Pediatr (Engl Ed) ; 99(5): 304-311, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37867012

RESUMEN

INTRODUCTION: The aim of this study was to evaluate the accuracy of imaging tests (prenatal ultrasound [US] and postnatal computed tomography [CT]) in comparison to histology for diagnosis of congenital lung malformations (CLMs). MATERIAL AND METHODS: Retrospective study of patients with a prenatal diagnosis of CLM whose postnatal follow-up included thoracic CT scan and histological examination of the lesion. We collected data on demographic variables, gestational age at diagnosis, US findings and the history of multiple gestation. We used the kappa coefficient to determine the level of agreement between the findings of prenatal US and postnatal tests (CT and histology).We analysed paired data on the size of the lesion, its location and the presence or absence of systemic arterial vascularization. RESULTS: The sample included 56 patients with 57 lesions. The mean gestational age at diagnosis was 22.42 weeks (SD, 3.94) and 57% were male. Malformations most frequently involved the left lung and the lower lobes. The agreement between CT and histology in the detection of cystic lesions was moderate (κ = 0.55) but stronger compared to the agreement between US and histology (κ = 0.10). The agreement between CT and histology was substantial (κ = 0.66) in the detection of systemic vascularization of the lesion and stronger compared to the agreement between US and histology. Both imaging methods were highly accurate in the identification of the location of the pulmonary lesions. CONCLUSIONS: postnatal CT offers a substantial concordance with histological findings, especially in the detection of systemic vascularization, and an accurate prediction of the anatomy of the lesion.


Asunto(s)
Enfermedades Pulmonares , Ultrasonografía Prenatal , Embarazo , Femenino , Humanos , Masculino , Estudios Retrospectivos , Ultrasonografía Prenatal/métodos , Imagen por Resonancia Magnética/métodos , Enfermedades Pulmonares/congénito , Enfermedades Pulmonares/patología , Pulmón/diagnóstico por imagen , Pulmón/anomalías
3.
Fetal Diagn Ther ; 50(2): 136-142, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36996799

RESUMEN

INTRODUCTION: Cystic fibrosis (CF) is a potentially severe disease. The development of new therapies with cystic fibrosis transmembrane conductance regulator (CFTR) modulators has been a great advance in the management of this condition because they improve the function of the faulty CFTR protein rather than palliate its consequences. CFTR modulator therapy improves pancreatic and lung function and, therefore, quality of life, with greater benefits the sooner treatment is started. For this reason, the use of these therapies is being approved for increasingly younger patients. Only two cases of pregnant women taking CFTR modulator therapy with CF fetuses have been reported, suggesting that it could resolve meconium ileus (MI) prenatally and delay/prevent other consequences of CF. CASE PRESENTATION: We report a case of a healthy pregnant patient who underwent CFTR modulator therapy with elexacaftor-tezacaftor-ivacaftor (ETI) in order to treat her fetus with CF (F508del homozygous CFTR mutation) and MI. Ultrasound findings suggestive of MI were observed at 24 weeks. Both parents were tested for CFTR mutations, and both were carriers of the F508del CFTR mutation. The fetus was diagnosed with CF by amniocentesis at 26+2 weeks. Maternal ETI therapy was initiated at 31+1 weeks, and no dilated bowel was observed at 39 weeks. There were no signs of bowel obstruction after birth. Maternal ETI treatment was continued during breastfeeding, with normal liver function. Immunoreactive trypsinogen in the newborn was 58.1 ng/mL, sweat chloride test was 80 mmol/L, and fecal elastase on the second day of life was 58 µg/g. CONCLUSION: Prenatal ETI treatment, as well as during breastfeeding, could solve, prevent, and/or delay CF complications.


Asunto(s)
Regulador de Conductancia de Transmembrana de Fibrosis Quística , Fibrosis Quística , Humanos , Embarazo , Recién Nacido , Femenino , Regulador de Conductancia de Transmembrana de Fibrosis Quística/genética , Fibrosis Quística/complicaciones , Fibrosis Quística/tratamiento farmacológico , Fibrosis Quística/genética , Calidad de Vida , Mutación , Feto/metabolismo
4.
Plants (Basel) ; 11(20)2022 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-36297712

RESUMEN

Increase in soil salinity, driven by climate change, is a widespread constrain for viticulture across several regions, including the Mediterranean basin. The implementation of salt-tolerant varieties is sought after to reduce the negative impact of salinity in grape production. An accession of wild grapevine (Vitis vinifera L. ssp. sylvestris), named AS1B, found on the coastline of Asturias (Spain), could be of interest toward the achievement of salt-tolerant varieties, as it demonstrated the ability to survive and grow under high levels of salinity. In the present study, AS1B is compared against widely cultivated commercial rootstock Richter 110, regarding their survival capabilities, and transcriptomic profiles analysis allowed us to identify the genes by employing RNA-seq and gene ontology analyses under increasing salinity and validate (via RT-qPCR) seven salinity-stress-induced genes. The results suggest contrasting transcriptomic responses between AS1B and Richter 110. AS1B is more responsive to a milder increase in salinity and builds up specific mechanisms of tolerance over a sustained salt stress, while Richter 110 maintains a constitutive expression until high and prolonged saline inputs, when it mainly shows responses to osmotic stress. The genetic basis of AS1B's strategy to confront salinity could be valuable in cultivar breeding programs, to expand the current range of salt-tolerant rootstocks, aiming to improve the adaptation of viticulture against climate change.

5.
Sensors (Basel) ; 21(19)2021 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-34640957

RESUMEN

One of the most popular options in the Structural Health Monitoring field is the tracking of the modal parameters, which are estimated through the frequency response functions of the structure, usually in the form of accelerances, which are computed as the ratio between the measured accelerations and the applied forces. This requires the use of devices capable of synchronously recording accelerations at several points of the structure at high sampling rates and the subsequent computational analysis using the recorded data. To this end, this work presents and validates a new scalable acquisition system based on multiple myRIO devices and digital MEMS (Micro-Electro-Mechanical System) accelerometers, intended for modal analysis of large structures. A simple form of this system was presented by the authors in a previous work, showing that a single board with some accelerometers connected to it got to obtain high quality measurements in both time and frequency domains. Now, a larger system composed by several slave boards connected and synchronized to a master one is presented. Delays lower than 100 ns are found between the synchronised channels of the proposed system. For validation purposes, a case study is presented where the devices are deployed on a timber platform to estimate its modal properties, which are compared with the ones provided by a commercial system, based on analog accelerometers, to show that similar results are obtained at a significantly lower cost.


Asunto(s)
Aceleración , Sistemas Microelectromecánicos
6.
J Clin Med ; 10(16)2021 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-34441986

RESUMEN

To assess prospectively the capability of our previously reported global multiparameter scoring system to predict coarctation of the aorta (CoAo) in fetuses with cardiac asymmetry, we applied and analyzed the performance of our scoring system in predicting postnatal CoAo in fetuses undergoing prenatal echocardiographic assessment because of cardiac asymmetry between 2011 and 2021, and we determined the cut-off points of the score with the best balance between specificity and sensitivity, and of maximum sensitivity and specificity. CoAo was confirmed in 39/179 newborns (21.8%). We found a significantly higher probability of CoAo in fetuses with CoAo than in cases without CoAo (84.2 ± 18.2% vs. 26.0 ± 28.6%, p < 0.001). The AUC of the ROC of the score was 0.93 (95% CI 0.89-0.97). The cut-off value with the best balance between specificity and sensitivity was a predicted risk of ≥53% (sensitivity 92.3% and specificity 80.0%). The cut-off point of maximum sensitivity was ≥35% (sensitivity 100% and specificity 72.9%), and that of maximum specificity was ≥96% (sensitivity 43.6% and specificity 96.4%). In none of the fetuses with a probability of CoAo < 35% was this condition confirmed after birth. This occurred in 102 fetuses in the whole study population (57%) and in 84 of the 111 in whom CoAo was suspected beyond 28 weeks (75.7%). This multiparameter score allows an adequate discrimination between fetuses without CoAo and those with CoAo, reducing the false positive diagnoses in cardiac asymmetry.

7.
Sensors (Basel) ; 21(12)2021 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-34204484

RESUMEN

Pedestrian detection by a car is typically performed using camera, LIDAR, or RADAR-based systems. The first two systems, based on the propagation of light, do not work in foggy or poor visibility environments, and the latter are expensive and the probability associated with their ability to detect people is low. It is necessary to develop systems that are not based on light propagation, with reduced cost and with a high detection probability for pedestrians. This work presents a new sensor that satisfies these three requirements. An active sound system, with a sensor based on a 2D array of MEMS microphones, working in the 14 kHz to 21 kHz band, has been developed. The architecture of the system is based on an FPGA and a multicore processor that allow the system to operate in real time. The algorithms developed are based on a beamformer, range and lane filters, and a CFAR (Constant False Alarm Rate) detector. In this work, tests have been carried out with different people and in different ranges, calculating, in each case and globally, the Detection Probability and the False Alarm Probability of the system. The results obtained verify that the developed system allows the detection and estimation of the position of pedestrians, ensuring that a vehicle travelling at up to 50 km/h can stop and avoid a collision.


Asunto(s)
Sistemas Microelectromecánicos , Peatones , Accidentes de Tránsito , Urgencias Médicas , Estudios de Factibilidad , Humanos
8.
Pediatr Infect Dis J ; 40(3): e115-e117, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33565817

RESUMEN

In utero transmission of severe acute respiratory syndrome coronavirus 2 infection is a point of debate. We report a case of severe acute respiratory syndrome coronavirus 2 vertical transmission from asymptomatic mother, with molecular detection in mother's blood at delivery and neonatal nasopharyngeal swabs at 5 and 28 hours of life and later IgG seroconversion. The newborn was asymptomatic.


Asunto(s)
COVID-19/transmisión , Transmisión Vertical de Enfermedad Infecciosa , SARS-CoV-2/aislamiento & purificación , Enfermedades Asintomáticas , COVID-19/diagnóstico , COVID-19/virología , Femenino , Humanos , Recién Nacido , Madres , Embarazo , SARS-CoV-2/genética
9.
Sensors (Basel) ; 21(2)2021 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-33477780

RESUMEN

This paper presents the design, development and testing of a low-cost Structural Health Monitoring (SHM) system based on MEMS (Micro Electro-Mechanical Systems) triaxial accelerometers. A new control system composed by a myRIO platform, managed by specific LabVIEW software, has been developed. The LabVIEW software also computes the frequency response functions for the subsequent modal analysis. The proposed SHM system was validated by comparing the data measured by this set-up with a conventional SHM system based on piezoelectric accelerometers. After carrying out some validation tests, a high correlation can be appreciated in the behavior of both systems, being possible to conclude that the proposed system is sufficiently accurate and sensitive for operative purposes, apart from being significantly more affordable than the traditional one.

10.
Sensors (Basel) ; 20(3)2020 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-31973156

RESUMEN

Detecting and finding people are complex tasks when visibility is reduced. This happens, for example, if a fire occurs. In these situations, heat sources and large amounts of smoke are generated. Under these circumstances, locating survivors using thermal or conventional cameras is not possible and it is necessary to use alternative techniques. The challenge of this work was to analyze if it is feasible the integration of an acoustic camera, developed at the University of Valladolid, on an unmanned aerial vehicle (UAV) to locate, by sound, people who are calling for help, in enclosed environments with reduced visibility. The acoustic array, based on MEMS (micro-electro-mechanical system) microphones, locates acoustic sources in space, and the UAV navigates autonomously by closed enclosures. This paper presents the first experimental results locating the angles of arrival of multiple sound sources, including the cries for help of a person, in an enclosed environment. The results are promising, as the system proves able to discriminate the noise generated by the propellers of the UAV, at the same time it identifies the angles of arrival of the direct sound signal and its first echoes reflected on the reflective surfaces.


Asunto(s)
Sistemas Microelectromecánicos/métodos , Tecnología de Sensores Remotos/métodos , Diseño de Equipo , Humanos
12.
BMC Anesthesiol ; 19(1): 17, 2019 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-30704463

RESUMEN

BACKGROUND: Bupivacaine and levobupivacaine have similar pharmacokinetic and pharmacodynamic characteristics, and are used regularly in spinal anesthesia. Whether potential differences in their hemodynamic and anesthetic profiles could determine a differential risk of complications in elderly subjects, is controversial. The main objective was to compare the effects of intrathecally administered levobupivacaine (LB) versus bupivacaine (B), on regional cerebral O2 saturation during spinal anesthesia, cognitive status and neurological complications in elderly patients undergoing surgery for hip fracture. METHODS: This was a randomized, controlled, single blind study. 58 patients aged 70 or older undergoing surgery for hip fracture with spinal anesthesia were allocated with a 1:1 ratio to receive LB or B, combined with fentanyl 15 µg, by intrathecal route. The primary outcome was the proportion of intraoperative time with regional cerebral desaturation (≥20% reduction in regional cerebral oxygen saturation from baseline), monitored by near -infrared spectroscopy. Secondary endpoints included hemodynamic parameters, level of sensory and motor block, changes in Short Portable Mental Status Questionnaire (SPMSQ), and neurological complications. RESULTS: The mean percentage of intraoperative time with desaturation in the B group was 6.1% (SD: 17.5) and 4.7% (SD: 11.9) in the left and right hemisphere respectively; in the LB group the mean was 4.8% (SD: 11.4) in the left hemisphere and 2.4% (SD: 8.3) in the right one. No statistically significant differences were found between treatment groups. The level of sensory block at the start of surgery was lower for LB than for B (Th10 vs Th8, p:0.047) and motor block at 15 min was lower for LB (2.5 vs 3, p:0.009). No differences in postoperative SPMSQ were observed. Neurological complications such as confusional state, agitation or disorientation were reported in 50% of patients in the B group and 21.4% of patients in the LB group, p = 0.05. CONCLUSIONS: No statistically significant differences in regional cerebral oxygen saturation or hemodynamic parameters were observed between both treatment groups. Bupivacaine and levobupivacaine differed in sensory and motor block achieved. While no differences were observed in cognitive impairment measured by the SPMSQ between treatment groups neurological complications reported by the physician were more frequent with bupivacaine. TRIAL REGISTRATION: European Union Clinical Trials Register ( EudraCT 2013-000846 -20 ) (April 9th, 2013). ClinicalTrials.gov ( NCT01960543 ) (September 23rd, 2013).


Asunto(s)
Anestesia Raquidea/métodos , Bupivacaína/administración & dosificación , Fracturas de Cadera/cirugía , Levobupivacaína/administración & dosificación , Oxígeno/metabolismo , Anciano , Anciano de 80 o más Años , Anestésicos Locales/administración & dosificación , Femenino , Fentanilo/administración & dosificación , Humanos , Inyecciones Espinales , Masculino , Procedimientos Ortopédicos/métodos , Método Simple Ciego
13.
J Matern Fetal Neonatal Med ; 32(4): 617-625, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28978246

RESUMEN

INTRODUCTION: Cytomegalovirus (CMV) is the leading cause of congenital infection worldwide. Data about the management of CMV infection in pregnant women are scarce, and treatment options are very limited. The aim of the study is to investigate the effectiveness of cytomegalovirus hyperimmune globulin (CMV-HIG) for the prevention and treatment of congenital CMV (cCMV) infection. MATERIALS AND METHODS: A retrospective observational study was conducted in three tertiary hospitals in Madrid. In the period 2009-2015, CMV-HIG (Cytotect® CP Biotest, Biotest) treatment was offered to all pregnant women with primary CMV infection and/or detection of CMV-DNA in amniotic fluid in participating centers. Women were divided into prevention and treatment groups (PG and TG, respectively). Those with primary CMV infection who had not undergone amniocentesis comprised the PG and received monthly CMV-HIG (100 UI/kg). If CMV-DNA was subsequently detected in amniotic fluid, one extra dose of CMV-HIG (200 UI/kg) was given 4 weeks after the last dose. Those women were considered to be part of the PG group despite detection of CMV-DNA in amniotic fluid. In the case of a negative result in CMV-DNA detection in amniotic fluid or if amniocentesis was not performed, monthly HIG was given up to the end of the pregnancy. RESULTS: Thirty-six pregnant women were included. Median gestational age at birth was 39 weeks (interquartile range: 38-40) and two children (5.5%) were premature (born at 28 and 34 weeks' gestation). Amniocentesis was performed in 30/36 (83.4%) pregnancies and CMV PCR was positive in 21 of them (70%). One fetus with a positive PCR in amniotic fluid that received one dose of HIG after amniocentesis presented a negative CMV-PCR in urine at birth, and was asymptomatic at 12 months of age. Twenty-four children were infected at birth, and 16/21 (76.2%) presented no sequelae at 12 months, while two (9.5%) had a mild unilateral hearing loss and three (14.3%) severe hearing loss or neurological sequelae. Seventeen women were included in the PG and 19 in the TG. In the PG 7/17 (41%) fetuses were infected, one pregnancy was terminated due to abnormalities in cordocentesis and one showed a mild hearing loss at 12 months of age. In the TG, 18/19 children (95%) were diagnosed with cCMV, while the remaining neonate had negative urine CMV at birth. Eight out of the 19 fetuses (42.1%) showed CMV related abnormalities in the fetal US before HIG treatment. Complete clinical assessment in the neonatal period and at 12 months of age was available in 16 and 15 children, respectively. At birth 50% were symptomatic and at 12 months of age, 4/15 (26.7%) showed a hearing loss and 3/15 (20%) neurologic impairment. Fetuses with abnormalities in ultrasonography before HIG presented a high risk of sequelae (odds ratios: 60; 95%CI: 3-1185; p = .007). DISCUSSION: Prophylactic HIG administration in pregnant women after CMV primary infection seems not to reduce significantly the rate of congenital infection, but is safe and it could have a favorable effect on the symptoms and sequelae of infected fetuses. The risk of long-term sequelae in fetuses without US abnormalities before HIG is low, so it could be an option in infected fetuses with normal imaging. On the other hand, the risk of sequelae among infected fetuses with abnormalities in fetal ultrasonography before HIG despite treatment is high.


Asunto(s)
Infecciones por Citomegalovirus/terapia , Enfermedades Fetales/prevención & control , Inmunoglobulinas Intravenosas/administración & dosificación , Complicaciones Infecciosas del Embarazo/terapia , Adulto , Amniocentesis , Líquido Amniótico/virología , Infecciones por Citomegalovirus/congénito , Infecciones por Citomegalovirus/prevención & control , Femenino , Enfermedades Fetales/virología , Humanos , Lactante , Recién Nacido , Transmisión Vertical de Enfermedad Infecciosa/prevención & control , Embarazo , Complicaciones Infecciosas del Embarazo/virología , Estudios Retrospectivos , España , Centros de Atención Terciaria , Ultrasonografía Prenatal
14.
Sensors (Basel) ; 18(1)2017 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-29295485

RESUMEN

Using arrays with digital MEMS (Micro-Electro-Mechanical System) microphones and FPGA-based (Field Programmable Gate Array) acquisition/processing systems allows building systems with hundreds of sensors at a reduced cost. The problem arises when systems with thousands of sensors are needed. This work analyzes the implementation and performance of a virtual array with 6400 (80 × 80) MEMS microphones. This virtual array is implemented by changing the position of a physical array of 64 (8 × 8) microphones in a grid with 10 × 10 positions, using a 2D positioning system. This virtual array obtains an array spatial aperture of 1 × 1 m². Based on the SODAR (SOund Detection And Ranging) principle, the measured beampattern and the focusing capacity of the virtual array have been analyzed, since beamforming algorithms assume to be working with spherical waves, due to the large dimensions of the array in comparison with the distance between the target (a mannequin) and the array. Finally, the acoustic images of the mannequin, obtained for different frequency and range values, have been obtained, showing high angular resolutions and the possibility to identify different parts of the body of the mannequin.

15.
Sensors (Basel) ; 16(10)2016 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-27727174

RESUMEN

This paper proposes a scalable and multi-platform framework for signal acquisition and processing, which allows for the generation of acoustic images using planar arrays of MEMS (Micro-Electro-Mechanical Systems) microphones with low development and deployment costs. Acoustic characterization of MEMS sensors was performed, and the beam pattern of a module, based on an 8 × 8 planar array and of several clusters of modules, was obtained. A flexible framework, formed by an FPGA, an embedded processor, a computer desktop, and a graphic processing unit, was defined. The processing times of the algorithms used to obtain the acoustic images, including signal processing and wideband beamforming via FFT, were evaluated in each subsystem of the framework. Based on this analysis, three frameworks are proposed, defined by the specific subsystems used and the algorithms shared. Finally, a set of acoustic images obtained from sound reflected from a person are presented as a case study in the field of biometric identification. These results reveal the feasibility of the proposed system.

16.
Rev. chil. obstet. ginecol ; 81(3): 229-233, jun. 2016. ilus
Artículo en Español | LILACS | ID: lil-788914

RESUMEN

Las cardiopatías son las malformaciones congénitas más frecuentes del desarrollo prenatal, en las que se produce un defecto en la arquitectura normal del corazón fetal interfiriendo en su buen funcionamiento en la vida postnatal. La proporción entre las diferentes cardiopatías varía mucho, sin embargo el Síndrome de Corazón Izquierdo Hipoplásico representa el 2-3% del total de cardiopatías congénitas constituyendo la forma más severa de lesiones obstructivas del corazón izquierdo y la de peor pronóstico. Su diagnóstico en etapas precoces de la gestación es hoy un reto para el obstetra, ya que su carácter evolutivo dificulta este hecho, no siendo en ocasiones, hasta etapas avanzadas de la gestación cuando se produce la alteración anatómica y la subsiguiente expresión ecográfica. Es en este punto donde se debe hacer hincapié, intentando aumentar el número de casos detectados precozmente, lo cual permitiría un adecuado aseso-ramiento familiar y la toma de decisiones oportuna. En los últimos años la introducción de terapias en patología cardíaca fetal, ha despertado un gran interés por tratar de modificar la evolución de esta enfermedad, siendo la valvuloplastía con balón aórtico la técnica de elección en pacientes seleccionados.


Congenital heart defects are the most frecuently congenital malformations in the prenatal development and consist of defect in the normal architecture of the fetal heart which interfering with its proper functioning. The proportion between the different heart disease varies widely, however Hypoplastic Left Heart Syndrome (HLHS) represent 2-3% of all congenital heart diseases and constitute the most severe obstructive lesions of the left heart and worse prognosis. The quickly diagnosis in early stages of the disease is an obstetrician challenge, however, it s evolutional feature hinders this proposal even in advanced stages of pregnancy when the anatomical alteration and subsequent ultrasound expression can be occur. At this point that should be emphasized to try increasing the number of cases detected early, which would allow a proper family counseling and timely decision. Recent years the introduction of therapies on fetal cardiac pathology, has aroused great interest in trying to change the course of the disease and the fetal aortic valvuloplasty with aortic balloon would be the choice technique in selected patients.


Asunto(s)
Humanos , Femenino , Embarazo , Adulto , Ultrasonografía Prenatal , Síndrome del Corazón Izquierdo Hipoplásico/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Síndrome del Corazón Izquierdo Hipoplásico/complicaciones , Diagnóstico Precoz , Cardiopatías Congénitas
17.
Rev Esp Cardiol (Engl Ed) ; 69(9): 836-41, 2016 Sep.
Artículo en Inglés, Español | MEDLINE | ID: mdl-27156642

RESUMEN

INTRODUCTION AND OBJECTIVES: There are few reports of the appearance of pulmonary arterial hypertension following arterial switch surgery in the neonatal period to correct transposition of the great arteries. We assessed the frequency and clinical pattern of this complication in our series of patients. METHODS: Our database was reviewed to select patients with transposition of the great arteries corrected by neonatal arterial switch at our hospital and who developed pulmonary hypertension over time. RESULTS: We identified 2 (1.3%) patients with transposition of the great arteries successfully repaired in the first week of life who later experienced pulmonary arterial hypertension. The first patient was a 7-year-old girl diagnosed with severe pulmonary hypertension at age 8 months who did not respond to medical treatment and required lung transplantation. The anatomic pathology findings were consistent with severe pulmonary arterial hypertension. The second patient was a 24-month-old boy diagnosed with severe pulmonary hypertension at age 13 months who did not respond to medical therapy. CONCLUSIONS: Pulmonary hypertension is a rare but very severe complication that should be investigated in all patients with transposition of the great arteries who have undergone neonatal arterial switch, in order to start early aggressive therapy for affected patients, given the poor therapeutic response and poor prognosis involved.


Asunto(s)
Operación de Switch Arterial/efectos adversos , Hipertensión Pulmonar/etiología , Complicaciones Posoperatorias/epidemiología , Presión Esfenoidal Pulmonar/fisiología , Transposición de los Grandes Vasos/cirugía , Cateterismo Cardíaco , Femenino , Estudios de Seguimiento , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/fisiopatología , Incidencia , Recién Nacido , Masculino , Estudios Retrospectivos , España/epidemiología
18.
Ginecol Obstet Mex ; 79(8): 493-6, 2011 Aug.
Artículo en Español | MEDLINE | ID: mdl-21966847

RESUMEN

Otocephaly is a rare and lethal congenital malformation characterized by the presence of agnathia, microstomia, aglossia and synotia. Despite its frequent association with severe malformations, diagnosis in the few published cases is usually made at III trimester. In this case, three-dimensional ultrasound scan was performed in a Chinese primigravida with no remarkable personal nor familiar history since mandible was difficulty visualized with two-dimensional sonography at 21 weeks of gestation. Multiplanar and rendering mode showed the typical cervicofacial features of otocephaly without associated malformations. After parental counselling, they opted for termination of pregnancy and necropsy confirmed our prenatal findings. Our case shows the usefulness of three-dimensional ultrasound in assessing fetal cervicofacial pathology. Volumetric capture allows a delayed study of fetal anatomy and multiplanar mode offers the reconstruction of views whose achivement is difficult with conventional 2D ultrasound. Surface rendering provides excellent spatial vision and enables parents to understand the severity of the malformation thus helping with their decisions.


Asunto(s)
Región Branquial/anomalías , Anomalías Craneofaciales/diagnóstico por imagen , Imagenología Tridimensional , Ultrasonografía Prenatal/métodos , Aborto Eugénico , China/etnología , Anomalías Craneofaciales/embriología , Femenino , Humanos , Recién Nacido , Embarazo , Segundo Trimestre del Embarazo , Adulto Joven
19.
Sensors (Basel) ; 11(11): 10724-37, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22346668

RESUMEN

The rising older people population has increased the interest in ambient assisted living systems. This article presents a system for monitoring the disabled or older persons developed from an existing surveillance system. The modularity and adaptability characteristics of the system allow an easy adaptation for a different purpose. The proposed system uses a network of sensors capable of motion detection that includes fall warning, identification of persons and a configurable control system which allows its use in different scenarios.


Asunto(s)
Instituciones de Vida Asistida/métodos , Monitoreo Ambulatorio/métodos , Tecnología de Sensores Remotos/métodos , Accidentes por Caídas/prevención & control , Acústica , Algoritmos , Hogares para Ancianos , Humanos , Vida Independiente , Monitoreo Ambulatorio/instrumentación , Casas de Salud , Dispositivo de Identificación por Radiofrecuencia/métodos , Tecnología de Sensores Remotos/instrumentación , Grabación en Video/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...