Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
2.
J Clin Monit Comput ; 37(3): 761-763, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36463338

RESUMEN

PURPOSE: Scalp block is a regional anesthesia technique to reduce the sympathetic response to skull pin application and postoperative pain in patients undergoing craniotomy. These blocks are often performed prior to surgical incision, however, the effect that these blocks have on neuronavigation facial tracing recognition accuracy is unclear because they may distort facial anatomy. METHODS: A series of 25 patients undergoing supratentorial craniotomy were administered scalp blocks prior to surgical incision, and their effect on neuronavigation accuracy was assessed. Statistical analysis utilized a two-tailed matched t-test. RESULTS: Bilateral supraorbital and auriculotemporal scalp blocks did not significantly affect the accuracy of facial recognition registration. CONCLUSION: Scalp block does not interfere with neuronavigation facial recognition accuracy during neurosurgical procedures.


Asunto(s)
Reconocimiento Facial , Bloqueo Nervioso , Herida Quirúrgica , Humanos , Cuero Cabelludo/cirugía , Herida Quirúrgica/cirugía , Neuronavegación/métodos , Bloqueo Nervioso/métodos , Craneotomía/métodos , Dolor Postoperatorio
5.
Cureus ; 13(3): e13999, 2021 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-33880314

RESUMEN

INTRODUCTION:  Large-bore cannulas are critical to administering IV fluids and blood products during resuscitation and treatment of hemorrhage. Although catheter flow rates for crystalloid solutions are well defined, rapid administration of blood products is poorly characterized. In this in vitro study, we examined the effects of hemodilution and needleless connectors on red blood cell (RBC) flow rates. METHODS:  To determine RBC flow rates through large-bore cannulae, a crystalloid solution (Normosol®, Hospira, Lake Forest, IL) or RBC units were warmed and delivered under pressure (360 mmHg) using a Level 1 H-1200 Fast Flow Fluid Warmer (Smiths Medical, St. Paul, MN). Flow rates for crystalloid, packed RBCs and diluted RBCs were determined using a stopwatch. Additionally, the effect of the MaxPlus® clear needleless connector (CareFusion, San Diego, CA) was measured in all three infusion groups. RESULTS:  Flow rates for undiluted RBC units were 53% slower than crystalloid solution (220 mL/min vs. 463 mL/min; p=0.0003), however, when RBC units were diluted to a hematocrit of ~30% flow rate improved to 369 mL/min (p=0.005). The addition of the MaxPlus® needleless connector reduced flow of crystalloid solution by 47% (245 mL/min; p=0.0001), undiluted RBCs by 64% (78 mL/min; p=0.01), and diluted RBCs by 51% (180 mL/min; p=0.00003). Compared to undiluted RBC units, hemodilution increased RBC delivery rate through a MaxPlus® connector by 130% (p=0.004) and by 68% (p=0.02) when the catheter was directly connected to the Level 1 tubing (MaxPlus® excluded). CONCLUSION:  In settings requiring rapid transfusion of RBC units, needleless connectors should not be used and hemodilution should be considered in order to decrease the time required to deliver an equivalent red cell mass.

6.
Am J Obstet Gynecol MFM ; 3(1): 100256, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33451609

RESUMEN

Patients who present with brain tumors during pregnancy require unique imaging and neurosurgical, obstetrical, and anesthetic considerations. Here, we review the literature and discuss the management of patients who present with brain tumors during pregnancy. Between 2009 and 2019, 9 patients were diagnosed at our institution with brain tumors during pregnancy. Clinical information was extracted from the electronic medical records. The median age at presentation was 29 years (range, 25-38 years). The most common symptoms at presentation included headache (n=5), visual changes (n=4), hemiparesis (n=3), and seizures (n=3). The median gestational age at presentation was 20.5 weeks (range, 11-37 weeks). Of note, 8 patients (89%) delivered healthy newborns, and 1 patient terminated her pregnancy. In addition, 5 patients (56%) required neurosurgical procedures during pregnancy (gestational ages, 14-37 weeks) because of disease progression (n=2) or neurologic instability (n=3). There was 1 episode of postneurosurgery morbidity (pulmonary embolism [PE]) and no surgical maternal mortality. The median length of follow-up was 15 months (range, 6-45 months). In cases demonstrating unstable or progressive neurosurgical status past the point of fetal viability, neurosurgical intervention should be considered. The physiological and pharmacodynamic changes of pregnancy substantially affect anesthetic management. Pregnancy termination should be discussed and offered to the patient when aggressive disease necessitates immediate treatment and the fetal gestational age remains previable, although neurologically stable patients may be able to continue the pregnancy to term. Ultimately, pregnant patients with brain tumors require an individualized approach to their care under the guidance of a multidisciplinary team.


Asunto(s)
Neoplasias Encefálicas , Neoplasias Encefálicas/diagnóstico , Femenino , Viabilidad Fetal , Edad Gestacional , Humanos , Lactante , Recién Nacido , Mortalidad Materna , Procedimientos Neuroquirúrgicos , Embarazo
8.
J Neurosurg Anesthesiol ; 33(4): 351-355, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31876633

RESUMEN

BACKGROUND: Intraoperative neurophysiological monitoring is of critical importance in evaluating the functional integrity of the central nervous system during surgery of the central or peripheral nervous system. In a large recent study, transcranial motor-evoked potentials (TcMEPs) were found to be associated with a 0.7% risk of inducing a seizure as diagnosed by clinical observation and electromyography in patients having general anesthesia with intravenous anesthetics. The gold standard for seizure diagnosis, however, is electroencephalography (EEG). The aim of this single-institution retrospective study is to ascertain the risk of intraoperative seizures detected using EEG during surgeries in adult patients undergoing intraoperative monitoring with TcMEPs. METHODS: The authors retrospectively reviewed the intraoperative EEG records of 1175 patients anesthetized with a variety of anesthetic agents, including volatile and intravenous anesthetics, to ascertain the rate of EEG-diagnosed seizures attributable to TcMEPs. RESULT: Our analysis did not reveal a single seizure event attributable to TcMEPs in 1175 patients. CONCLUSION: The intraoperative use of TcMEPs does not seem to cause seizures.


Asunto(s)
Potenciales Evocados Motores , Monitorización Neurofisiológica Intraoperatoria , Adulto , Electromiografía , Humanos , Estudios Retrospectivos , Convulsiones/etiología
9.
J Clin Monit Comput ; 35(6): 1269-1277, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-32951188

RESUMEN

Measurement of pupillary characteristics, such as pupillary unrest in ambient light, and reflex dilation have been shown to be useful in a variety of clinical situations. Dedicated pupillometers typically capture images in the near-infrared to allow imaging in both light and darkness. However, because a subset of pupillary measurements can be acquired with levels of visible light suitable for conventional cameras, it is theoretically possible to capture data using general purpose cameras and computing devices such as those found on smartphones. Here we describe the development of a smartphone-based pupillometer and compare its performance with a commercial pupillometer. Smartphone pupillometry software was developed and then compared with a commercial pupillometer by performing simultaneous scans in both eyes, using the smartphone pupillometer and a commercial pupillometer. The raw scans were compared, as well as a selected pupillary index: pupillary unrest in ambient light. In 77% of the scans the software was able to successfully identify the pupil and iris. The raw data as well as calculated values of pupillary unrest in ambient light were in clinically acceptable levels of agreement; Bland-Altman analysis of raw pupil measurements yielded a 95% confidence interval of 0.26 mm. In certain situations a smartphone pupillometer may be an appropriate alternative to a commercial pupillometer.


Asunto(s)
Pupila , Teléfono Inteligente , Estudios de Factibilidad , Humanos
11.
A A Pract ; 14(13): e01337, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33185408

RESUMEN

The inadvertent crossover between O2 and N2O pipelines has become extremely rare in practice. We describe a case where it was possible to ventilate with 100% N2O instead of the intended 100% O2 on a modern anesthesia delivery system (Dräger Apollo; Drägerwerk AG & Co KgaA, Lübeck, Germany). This was the result of the incorrect assembly of diameter index safety system (DISS) components during preventative maintenance that defeated the DISS failsafe system. To make incorrect assembly easier to avoid, DISS component labeling could be more prominent and color-coded, or the internal construction of the gas manifold could incorporate DISS.


Asunto(s)
Anestesia , Óxido Nitroso , Humanos , Oxígeno
12.
J Stroke Cerebrovasc Dis ; 29(9): 104830, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32807407

RESUMEN

BACKGROUND AND PURPOSE: Nitric oxide (NO) plays a key role in ischemia and shows potential as a biomarker for ischemia. We measured mixed venous nitrite (NO2-) as a proxy for NO, during controlled cerebral ischemia in patients with moyamoya disease (MMD) during direct extracranial/intracranial (EC/IC) bypass surgery with temporary occlusion of the M4 branch of the middle cerebral artery (MCA) to permit anastomosis with the superficial temporal artery (STA). This small, focal ischemic event is not reliably detected using cerebral oximetry, somatosensory evoked potentials (SSEPs) or electroencephalography (EEG). METHODS: We enrolled nine adult MMD patients (n=8 female, n=1 male) undergoing direct EC/IC bypass surgery. Nitrite was measured at least one hour prior to MCA occlusion, and before, during and after anastomosis. Cortical function was monitored using either multi-lead EEG and SSEPs, or frontal EEG activity. RESULTS: Mixed venous NO2- was significantly elevated (p<0.05) within 12 min following arterial occlusion vs. baseline. An M4 branch of the MCA was cross clamped for a median duration of 18 (IQR = 5) minutes during anastomosis. One patient with elevated NO2- showed a transient neurologic deficit that resolved 3 days post-operatively. CONCLUSIONS: Mixed venous NO2- was significantly elevated shortly following cerebral artery occlusion vs. baseline in a majority of the study subjects, suggesting that NO2- is a potential biomarker for ischemia. Since all patients received identical burst suppression anesthesia and vasopressors, the fact that NO2- was not elevated during cross-clamp in all patients supports the conclusion that the NO2- elevation is likely due to ischemia.


Asunto(s)
Isquemia Encefálica/diagnóstico , Revascularización Cerebral , Arteria Cerebral Media/cirugía , Enfermedad de Moyamoya/cirugía , Nitritos/sangre , Arterias Temporales/cirugía , Oclusión Terapéutica , Adulto , Biomarcadores/sangre , Isquemia Encefálica/sangre , Isquemia Encefálica/etiología , Isquemia Encefálica/fisiopatología , Revascularización Cerebral/efectos adversos , Circulación Cerebrovascular , Circulación Colateral , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Cerebral Media/diagnóstico por imagen , Arteria Cerebral Media/fisiopatología , Enfermedad de Moyamoya/sangre , Enfermedad de Moyamoya/diagnóstico por imagen , Enfermedad de Moyamoya/fisiopatología , Valor Predictivo de las Pruebas , Factores de Riesgo , Arterias Temporales/diagnóstico por imagen , Arterias Temporales/fisiopatología , Oclusión Terapéutica/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Regulación hacia Arriba , Vasodilatación
14.
A A Pract ; 14(3): 69-71, 2020 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-31770135

RESUMEN

We present the case of a 42-year-old man with moyamoya disease presenting for cerebral revascularization surgery who developed critical hyperkalemia following a single intravenous (iv) dose of 1000 mg of acetazolamide 1 day preoperatively for a cerebrovascular reactivity study. His potassium increased from 5.1 to 6.7 mmol/L. Prompt treatment of this abnormality allowed this patient to undergo surgery the next day uneventfully. A paradoxical, critical increase in potassium can result from a single 1000-mg iv dose of acetazolamide.


Asunto(s)
Acetazolamida/efectos adversos , Hiperpotasemia/inducido químicamente , Acetazolamida/administración & dosificación , Administración Intravenosa , Adulto , Manejo de la Enfermedad , Humanos , Enfermedad de Moyamoya/cirugía
15.
A A Pract ; 13(11): 440-441, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31609724

RESUMEN

Operating room waste is categorized as noncontaminated solid waste (SW) and regulated medical waste (RMW). RMW is treated by autoclaving at an increased economic and environmental cost. We evaluated these costs with a focus on the disposable carbon dioxide (CO2) absorbers. At our institution, exhausted CO2 absorbers were discarded as RMW. We collaborated with product representatives, anesthesia and perioperative staff, and waste management personnel to identify opportunities and barriers for recycling and waste reduction. Ultimately, we agreed to discard CO2 absorbers as SW instead of RMW, a strategy that is practical, less expensive, and more environmentally appropriate.


Asunto(s)
Dióxido de Carbono/análisis , Eliminación de Residuos Sanitarios/economía , Residuos Sanitarios/clasificación , Anestesiología , Eliminación de Residuos Sanitarios/métodos , Quirófanos , Reciclaje , Estados Unidos
16.
Anesth Analg ; 129(5): e174, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31453866
17.
Cureus ; 11(1): e3863, 2019 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-30899614

RESUMEN

Background Postoperative management in patients undergoing craniotomy is unique and challenging. We utilized a population of patients who underwent bilateral extracranial-to-intracranial (EC-IC bypass) revascularization procedures for moyamoya disease and hypothesized that 1 gram (gm) of intravenous (IV) acetaminophen given immediately after intubation and again 45 minutes prior to the end of craniotomy may be more effective than saline in minimizing opiate consumption and decreasing pain scores. Methods In a double-blind, randomized, placebo-controlled crossover pilot study, 40 craniotomies in 20 patients were studied. A random number generator assigned patients to receive either 1 gram of IV acetaminophen or an equal volume of normal saline immediately after intubation and again 45 minutes prior to the end of their first operation. For the second surgery, patients received the study drug (IV acetaminophen or normal saline) that they did not receive during their first surgery. Results In the IV acetaminophen group, the average 24-hour postoperative fentanyl equivalent consumption was decreased but the difference was not statistically significant: 228 micrograms compared to 312 micrograms in the placebo group (Figure 1; p = 0.09). Pain scores did not significantly differ between the IV acetaminophen group and the placebo group in postoperative hours 0-12 (Figure 2; p = 0.44) or 24 (Figure 3; p = 0.77). Conclusion Our study demonstrates that in patients receiving bilateral craniotomies for moyamoya disease, IV acetaminophen when given immediately after intubation and again 45 minutes prior to closure does not significantly decrease 12- or 24-hour postoperative opiate consumption.

18.
Can J Neurol Sci ; 46(3): 355-357, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30905329

RESUMEN

Head rotation causes compression and occlusion of the ipsilateral internal jugular (IJ) vein. This can result in raised intracranial pressure and increased bleeding if the patient is having or has recently had surgery. The amount of head rotation in adults resulting in occlusion of the ipsilateral IJ vein is unknown however. We measured the amount of head turn that produced occlusion of the ipsilateral IJ vein in 25 patients having surgery under general anesthesia. On average, 80% of IJ veins occlude at a mean of 55.6° on the left and 53.3° on the right.


Asunto(s)
Anestesia General , Cabeza , Venas Yugulares , Rotación , Posición Supina , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad
19.
Oper Neurosurg (Hagerstown) ; 17(4): 424-431, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-30629245

RESUMEN

BACKGROUND: Modern robotic-assist surgical systems have revolutionized stereotaxy for a variety of procedures by increasing operative efficiency while preserving and even improving accuracy and safety. However, experience with robotic systems in deep brain stimulation (DBS) surgery is scarce. OBJECTIVE: To present an initial series of DBS surgery performed utilizing a frameless robotic solution for image-guided stereotaxy, and report on operative efficiency, stereotactic accuracy, and complications. METHODS: This study included the initial 20 consecutive patients undergoing bilateral robot-assisted DBS. The prior 20 nonrobotic, frameless cohort of DBS cases was sampled as a baseline historic control. For both cohorts, patient demographic and clinical data were collected including postoperative complications. Intraoperative duration and number of Microelectrode recording (MER) and final lead passes were recorded. For the robot-assisted cohort, 2D radial errors were calculated. RESULTS: Mean case times (total operating room, anesthesia, and operative times) were all significantly decreased in the robot-assisted cohort (all P-values < .02) compared to frameless DBS. When looking at trends in case times, operative efficiency improved over time in the robot-assisted cohort across all time assessment points. Mean radial error in the robot-assisted cohort was 1.40 ± 0.11 mm, and mean depth error was 1.05 ± 0.18 mm. There was a significant decrease in the average number of MER passes in the robot-assisted cohort (1.05) compared to the nonrobotic cohort (1.45, P < .001). CONCLUSION: This is the first report of application of frameless robotic-assistance with the Mazor Renaissance platform (Mazor Robotics Ltd, Caesarea, Israel) for DBS surgery, and our findings reveal that an initial experience is safe and can have a positive impact on operative efficiency, accuracy, and safety.


Asunto(s)
Estimulación Encefálica Profunda , Temblor Esencial/terapia , Globo Pálido/cirugía , Neuroestimuladores Implantables , Enfermedad de Parkinson/terapia , Implantación de Prótesis/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Núcleo Subtalámico/cirugía , Núcleos Talámicos Ventrales/cirugía , Anciano , Eficiencia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Técnicas Estereotáxicas
20.
Anesth Analg ; 128(5): 891-900, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-29505449

RESUMEN

Medications used in anesthesiology contain both pharmacologically active compounds and additional additives that are usually regarded as being pharmacologically inactive. These additives, called excipients, serve diverse functions. Despite being labeled inert, excipients are not necessarily benign substances. Anesthesiologists should have a clear understanding of their chemical properties and the potential for adverse reactions. This report catalogs the excipients found in drugs commonly used in anesthesiology, provides a brief description of their function, and documents examples from the literature regarding their adverse effects.


Asunto(s)
Anestesia/métodos , Excipientes/efectos adversos , Anestesia/normas , Anestésicos/química , Animales , Alcohol Bencilo/química , Química Farmacéutica , Cresoles/química , Hipersensibilidad a las Drogas , Ácido Edético/química , Excipientes/química , Humanos , Verde de Indocianina/química , Inyecciones Espinales , Yoduros/química , Manitol/química , Modelos Animales , Parabenos/química , Periodo Perioperatorio , Propilenglicol/química , Sulfitos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...