Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Front Pharmacol ; 15: 1441251, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39295941

RESUMEN

Background: Angiotensin-converting enzyme inhibitors (ACEIs) are prescribed for individuals with high cardiovascular (CV) risk; however, persistent cough limits the use of ACEIs in a large number of patients. The current study aimed to identify the genetic variants in the SLCO1B1 gene that might be associated with ACEI-related cough in a Pakistani hypertensive population. Methods: A prospective cohort study was conducted at a tertiary care hospital in Pakistan. A total of 74 patients who had been treated with ACEIs were recruited through a convenient sampling method. The study was approved by the Institutional Review Board & Ethics Committee of the Shifa International Hospital, Islamabad. Patients provided 2 ml of blood for sequencing after signing informed consent. Partial gene sequencing of SLCO1B1 was carried out to find single nucleotide polymorphisms (SNPs) and haplotypes. Results: It was found, through a structured questionnaire, that thirty-eight (38) patients experienced cough within 2 weeks of ACEI administration and were considered as a case group (cough), and thirty-six (36) patients were considered as a control group (no cough). The incidence of cough was 51%. We found six different SNPs and 9 haplotypes in the partial gene sequences of SLCO1B1. Haplotype H4 was associated significantly with cough after adjusting for sex and smoking status. Other SNPs and haplotypes were not significantly associated with ACE-Is-induced cough. Conclusion: These findings emphasize the significance of SLCO1B1 genetic variants, specifically H4, as a potential predictor of ACEI-induced cough. It could be included in clinical practice as a possible risk factor for ACEI-induced cough once confirmed in larger clinical trials with bigger sample sizes. The replication of these findings in larger and more diverse populations is likely to contribute to the therapeutic use of ACEIs by predicting ACEI-induced cough.

3.
ACS Omega ; 9(22): 23355-23363, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38854579

RESUMEN

An increase in cocaine abuse has been observed globally since the past decade. Cocaine is among the commonly abused stimulants used for recreational purposes. In this study, the SPE-UHPLC-MS/MS method was developed and validated to be applied on real specimens of 20 chronic cocaine abusers to quantify cocaine/metabolites in conventional as well as alternative biological matrices. Cocaine was extracted from biological specimens using solid-phase extraction followed by liquid chromatography tandem mass spectrometry analysis. Chromatographic separation was achieved on a Poroshell120EC-18 column (2.1 mm × 50 mm, 2.7 µm particle size) using water-acetonitrile in 0.1% formic acid as a mobile phase in gradient elution mode. The flow rate of the mobile phase was 0.5 mL/min with a gradient varying the percentage of acetonitrile linearity ranging 15-95% in 6.0 min acquisition time, and the injection volume was set at 5 µL. Positive electrospray ionization with multireaction ion monitoring mode using two ion transitions for cocaine/metabolites and one for cocaine-d3 was employed. The quantification method demonstrated good linear ranges of 0.025-250 ng/mL in blood, urine, and oral fluid (ng/mg for hair and nail) with a ≥0.991% determination coefficient. The detection limit and lower quantification limit were 0.005 and 0.025 ng/mL in all matrices, respectively. The mean extraction recovery and ionization suppression ranged from 89.3 to 99.8% and -4.6 to -14.4% in the studied matrices. Within-run and between-days precisions were 1.8-7.2% and 1.9-6.1%, respectively. This study will not only help in quantifying cocaine/metabolites in alternative specimens (hair, nail, and oral fluid) but also guide clinical and forensic toxicologists in interpretation of exhumation cases. Furthermore, multiple specimens' analyses can be of significance in estimating the time/manner of drug exposure, in confirming the results of laboratories in cases of doubtful clinical histories, or in aiding medico-legal investigations.

4.
Sci Rep ; 14(1): 11431, 2024 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-38763930

RESUMEN

Our current study reports the successful synthesis of thiolated chitosan-based nanoparticles for targeted drug delivery of 5-Fluorouracil. This process was achieved through the ionic gelation technique, aiming to improve the efficacy of the chemotherapeutic moiety by modifying the surface of the nanoparticles (NPs) with a ligand. We coated these NPs with hyaluronic acid (HA) to actively target the CD44 receptor, which is frequently overexpressed in various solid malignancies, including breast cancer. XRD, FTIR, SEM, and TEM were used for the physicochemical analysis of the NPs. These 5-Fluorouracil (5-FU) loaded NPs were evaluated on MDA-MB-231 (a triple-negative breast cell line) and MCF-10A (normal epithelial breast cells) to determine their in vitro efficacy. The developed 5-FU-loaded NPs exhibited a particle size within a favorable range (< 300 nm). The positive zeta potential of these nanoparticles facilitated their uptake by negatively charged cancer cells. Moreover, they demonstrated robust stability and achieved high encapsulation efficiency. These nanoparticles exhibited significant cytotoxicity compared to the crude drug (p < 0.05) and displayed a promising release pattern consistent with the basic diffusion model. These traits improve the pharmacokinetic profile, efficacy, and ability to precisely target these nanoparticles, offering a potentially successful anticancer treatment for breast cancer. However, additional in vivo assessments of these formulations are obligatory to confirm these findings.


Asunto(s)
Quitosano , Fluorouracilo , Receptores de Hialuranos , Nanopartículas , Neoplasias de la Mama Triple Negativas , Fluorouracilo/administración & dosificación , Fluorouracilo/farmacología , Fluorouracilo/química , Quitosano/química , Humanos , Receptores de Hialuranos/metabolismo , Neoplasias de la Mama Triple Negativas/tratamiento farmacológico , Neoplasias de la Mama Triple Negativas/metabolismo , Neoplasias de la Mama Triple Negativas/patología , Nanopartículas/química , Línea Celular Tumoral , Femenino , Portadores de Fármacos/química , Ácido Hialurónico/química , Sistemas de Liberación de Medicamentos , Antimetabolitos Antineoplásicos/farmacología , Antimetabolitos Antineoplásicos/administración & dosificación , Antimetabolitos Antineoplásicos/farmacocinética , Antimetabolitos Antineoplásicos/química , Supervivencia Celular/efectos de los fármacos , Tamaño de la Partícula
5.
Pak J Pharm Sci ; 35(6(Special)): 1683-1690, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36861229

RESUMEN

Vancomycin (VAN) is an effective antibiotic due to its broad-spectrum bactericidal action. High performance liquid chromatography (HPLC), a powerful analytical technique is used for the in vitro/ in vivo quantification of VAN. The current study was aimed to detect the VAN from in vitro as well as the plasma after the extraction from blood of rabbits. The method was developed and validated according to International Council on Harmonization (ICH) Q2 R1 guidelines. Results showed that the peak of VAN was recorded at 2.96 and 2.57 min, respectively in vitro and serum. The coefficient of VAN turned out to be >0.9994 each for in vitro and in vivo samples. VAN was found linear in the range of 6.2-25000ng/mL. The values of accuracy and precision in terms of coefficient of variation (CV) were less than 2%, indicating the validity of the method. The values for LOD and LOQ were estimated to be 1.5 and 4.5ng/mL, correspondingly, which were lower than the values calculated from in vitro media. Furthermore, the score of the greenness found out to be 0.81, depicting good score using AGREE tool. It was concluded that the developed method was found accurate, precise, robust, rugged, linear, detectable and quantifiable at prepared analytical concentrations and could be used for in vitro and in vivo VAN determination.


Asunto(s)
Plasma , Vancomicina , Animales , Conejos , Cromatografía Líquida de Alta Presión , Antibacterianos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...