J Appl Lab Med ; 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39225046

RESUMEN

BACKGROUND: A dual filtration-based method for determination of serum labile bound copper (LBC) and LBC fraction (LBC/total copper) was developed. Reduced total copper, elevated LBC, and elevated LBC fraction have been reported in Wilson disease (WD). METHODS: To evaluate the diagnostic performance of these markers, samples were obtained from 21 WD treatment-naïve (WD-TN, no WD treatment or <28 days of treatment) patients, 46 WD standard-of-care-treated (WD-SOC) patients, along with 246 patients representing other potential disorders of copper status. These were then compared to 213 reference interval population patients. RESULTS: Receiver operating characteristic curves for the reference population vs WD-TN yielded areas under the curve for total copper, LBC, and LBC fraction, of 0.99, 0.81, and 0.98, respectively. Using Youden cutoffs, sensitivity/specificity for WD-TN was 95%/97% for total copper, 71%/85% for LBC, and 95%/94% for LBC fraction. LBC values, but not total copper and LBC fraction, differed substantially between WD-TN and WD-SOC cohorts.We propose a dual model wherein total copper and LBC fraction results must agree to be classified as a "positive" or "negative" result for WD. This correctly classified 19/21 WD-TN patients as positive, and 194/213 reference interval patients as negative. The remaining "indeterminate" patients (representing approximately 9% of the reference and the WD-TN populations) exhibited conflicting total copper and LBC fraction results. When indeterminate results are excluded, this model exhibited apparent 100% sensitivity/specificity. CONCLUSIONS: Agreement of total serum copper and LBC fraction classification may constitute an effective "rule-in" and "rule-out" assessment for WD-TN patients.

2.
World J Orthop ; 15(8): 773-782, 2024 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-39165877

RESUMEN

BACKGROUND: There is concern regarding potential long-term cardiotoxicity with systemic distribution of metals in total joint arthroplasty (TJA) patients. AIM: To determine the association of commonly used implant metals with echocardiographic measures in TJA patients. METHODS: The study comprised 110 TJA patients who had a recent history of high chromium, cobalt or titanium concentrations. Patients underwent two-dimensional, three-dimensional, Doppler and speckle-strain transthoracic echocardiography and a blood draw to measure metal concentrations. Age and sex-adjusted linear and logistic regression models were used to examine the association of metal concentrations (exposure) with echocardiographic measures (outcome). RESULTS: Higher cobalt concentrations were associated with increased left ventricular end-diastolic volume (estimate 5.09; 95%CI: 0.02-10.17) as well as left atrial and right ventricular dilation, particularly in men but no changes in cardiac function. Higher titanium concentrations were associated with a reduction in left ventricle global longitudinal strain (estimate 0.38; 95%CI: 0.70 to 0.06) and cardiac index (estimate 0.08; 95%CI, -0.15 to -0.01). CONCLUSION: Elevated cobalt and titanium concentrations may be associated with structural and functional cardiac changes in some patients. Longitudinal studies are warranted to better understand the systemic effects of metals in TJA patients.

3.
Lab Med ; 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39136221

RESUMEN

BACKGROUND: Due to the ability of metal ions to cross the blood-brain barrier, there has been interest in analyzing cerebrospinal fluid (CSF) for trace element concentrations to investigate possible correlations with neurodegenerative diseases. In this study, Sarstedt polypropylene CSF collection tubes were analyzed to determine the contamination levels of aluminum, titanium, chromium, manganese, cobalt, nickel, molybdenum, gadolinium, vanadium, arsenic, cadmium, mercury, lead, thallium, selenium, copper, zinc, and iron. METHODS: Sarstedt polypropylene CSF collection tubes from 2 separate lots (n = 10 per lot) were filled with a 2 mL aliquot of a CSF pool with known element concentrations. After 24 hours of leaching at room temperature, all 18 elements were analyzed via inductively coupled plasma mass spectrometry (ICP-MS). Results were subtracted from the initial pool concentration to determine contamination levels. RESULTS: No detectable contamination above the assay limit of detection was found in 11 analytes. Molybdenum and selenium contamination was measured in all tubes, and aluminum, titanium, manganese, thallium, and zinc had minimal levels of sporadic detectable contamination in 25% or fewer of the tubes tested. CONCLUSIONS: Sarstedt polypropylene CSF tubes are an acceptable collection tube for the analysis of most assessed metals in CSF.

4.
Int J Qual Health Care ; 36(3)2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-38955670

RESUMEN

Beta-lactam antibiotics are widely used in the intensive care unit due to their favorable effectiveness and safety profiles. Beta-lactams given to patients with sepsis must be delivered as soon as possible after infection recognition (early), treat the suspected organism (appropriate), and be administered at a dose that eradicates the infection (adequate). Early and appropriate antibiotic delivery occurs in >90% of patients, but less than half of patients with sepsis achieve adequate antibiotic exposure. This project aimed to address this quality gap and improve beta-lactam adequacy using the Define, Measure, Analyze, Improve, and Control Lean Six Sigma quality improvement framework. A multidisciplinary steering committee was formed, which completed a stakeholder analysis to define the gap in practice. An Ishikawa cause and effect (Fishbone) diagram was used to identify the root causes and an impact/effort grid facilitated prioritization of interventions. An intervention that included bundled education with the use of therapeutic drug monitoring (TDM; i.e. drug-level testing) was projected to have the highest impact relative to the amount of effort and selected to address beta-lactam inadequacy in the critically ill. The education and TDM intervention were deployed through a Plan, Do, Study, Act cycle. In the 3 months after "go-live," 54 episodes of beta-lactam TDM occurred in 41 unique intensive care unit patients. The primary quality metric of beta-lactam adequacy was achieved in 94% of individuals after the intervention. Ninety-four percent of clinicians gauged the education provided as sufficient. The primary counterbalance of antimicrobial days of therapy, a core antimicrobial stewardship metric, was unchanged over time (favorable result; P = .73). Application of the Define, Measure, Analyze, Improve, and Control Lean Six Sigma quality improvement framework effectively improved beta-lactam adequacy in critically ill patients. The approach taken in this quality improvement project is widely generalizable to other drugs, drug classes, or settings to increase the adequacy of drug exposure.


Asunto(s)
Antibacterianos , Enfermedad Crítica , Unidades de Cuidados Intensivos , Mejoramiento de la Calidad , Gestión de la Calidad Total , beta-Lactamas , Humanos , Enfermedad Crítica/terapia , Antibacterianos/uso terapéutico , Antibacterianos/administración & dosificación , beta-Lactamas/uso terapéutico , Sepsis/tratamiento farmacológico , Monitoreo de Drogas/métodos
5.
Transfusion ; 64(9): 1617-1622, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38979963

RESUMEN

INTRODUCTION: Phosphatidylethanol (PEth) is a long-term marker of alcohol consumption used frequently in clinical scenarios such as liver transplant evaluation. Recent cases have demonstrated that packed red blood cell (pRBC) transfusion creates the potential for artificial elevation or decrease of observed PEth concentrations in recipients. Very little is known about the prevalence or stability of PEth in pRBCs. METHODS: Apheresis and whole-blood (WB) donations were tested for PEth using liquid chromatography - tandem mass spectrometry with limit of quantitation 10 ng/mL. Units were stored under routine blood bank conditions to evaluate the stability of PEth and the impact of irradiation. RESULTS: Over 40% of apheresis and WB donors had PEth ≥10 ng/mL (maximum observed 587 ng/mL). As WB units were processed into component pRBCs, PEth concentrations increased and were higher than donor WB levels (EDTA sample) prior to collection (maximum observed 711 ng/mL). Storage for up to 5 weeks post donation resulted in mean 17.3% decrease in PEth-positive units; in contrast to a prior report, we observed no PEth formation in units with negative (<10 ng/mL) baseline concentrations. Irradiation of pRBCs did not substantially affect PEth concentrations in either PEth-positive or PEth-negative units. DISCUSSION: PEth concentrations in healthy blood donors may potentially confound alcohol use or abstinence assessment in pRBC recipients. Transfusion medicine services and clinical practices such as transplantation and behavioral medicine should recognize this phenomenon and collaborate on testing protocols to appropriately interpret PEth in pRBC recipients.


Asunto(s)
Biomarcadores , Donantes de Sangre , Glicerofosfolípidos , Humanos , Glicerofosfolípidos/sangre , Biomarcadores/sangre , Eliminación de Componentes Sanguíneos , Eritrocitos/metabolismo , Eritrocitos/química , Consumo de Bebidas Alcohólicas/sangre , Transfusión de Eritrocitos , Conservación de la Sangre , Femenino , Masculino , Cromatografía Liquida , Espectrometría de Masas en Tándem
6.
Clin Chem ; 70(7): 978-986, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38757262

RESUMEN

BACKGROUND: Abuse of fentanyl and its analogs is a major contributor to the opioid overdose epidemic in the United States, but detecting and quantifying trace amounts of such drugs remains a challenge without resorting to sophisticated mass spectrometry-based methods. METHODS: A sensitive immunoassay with a sub-picogram limit of detection for fentanyl and a wide range of fentanyl analogs has been developed, using a novel high-affinity antibody fused with NanoLuc, a small-size luciferase that can emit strong and stable luminescence. When used with human urine samples, the assay has a sub-picogram limit of detection for fentanyl, with results fully concordant with LC-MS. RESULTS: When applied to clinical samples, the novel chemiluminescence immunoassay can detect low positive fentanyl missed by routine screening immunoassays, with a limit of detection of 0.8 pg/mL in human urine. When applied to environmental samples, the assay can detect levels as low as 0.25 pg fentanyl per inch2 of environment surface. Assay turnaround time is less than 1 h, with inexpensive equipment and the potential for high-throughput automation or in-field screening. CONCLUSIONS: We have established a novel assay that may have broad applications in clinical, environmental, occupational, and forensic scenarios for detection of trace amounts of fentanyl and its analogs.


Asunto(s)
Fentanilo , Mediciones Luminiscentes , Fentanilo/orina , Fentanilo/análisis , Humanos , Inmunoensayo/métodos , Mediciones Luminiscentes/métodos , Límite de Detección , Detección de Abuso de Sustancias/métodos , Analgésicos Opioides/orina , Analgésicos Opioides/análisis
9.
Crit Care Explor ; 5(12): e1011, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38107538

RESUMEN

IMPORTANCE: Meropenem dosing is typically guided by creatinine-based estimated glomerular filtration rate (eGFR), but creatinine is a suboptimal GFR marker in the critically ill. OBJECTIVES: This study aimed to develop and qualify a population pharmacokinetic model for meropenem in critically ill adults and to determine which eGFR equation based on creatinine, cystatin C, or both biomarkers best improves model performance. DESIGN SETTING AND PARTICIPANTS: This single-center study evaluated adults hospitalized in an ICU who received IV meropenem from 2018 to 2022. Patients were excluded if they had acute kidney injury, were on kidney replacement therapy, or were treated with extracorporeal membrane oxygenation. Two cohorts were used for population pharmacokinetic modeling: a richly sampled development cohort (n = 19) and an opportunistically sampled qualification cohort (n = 32). MAIN OUTCOMES AND MEASURES: A nonlinear mixed-effects model was developed using parametric methods to estimate meropenem serum concentrations. RESULTS: The best-fit structural model in the richly sampled development cohort was a two-compartment model with first-order elimination. The final model included time-dependent weight normalized to a 70-kg adult as a covariate for volume of distribution (Vd) and time-dependent eGFR for clearance. Among the eGFR equations evaluated, eGFR based on creatinine and cystatin C expressed in mL/min best-predicted meropenem clearance. The mean (se) Vd in the final model was 18.2 (3.5) liters and clearance was 11.5 (1.3) L/hr. Using the development cohort as the Bayesian prior, the opportunistically sampled cohort demonstrated good accuracy and low bias. CONCLUSIONS AND RELEVANCE: Contemporary eGFR equations that use both creatinine and cystatin C improved meropenem population pharmacokinetic model performance compared with creatinine-only or cystatin C-only eGFR equations in adult critically ill patients.

10.
Arch Pathol Lab Med ; 2023 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-37870242

RESUMEN

CONTEXT.­: Clinical testing for Wilson disease (WD) is potentially challenging. Measuring the fraction of labile bound copper (LBC) to total copper may be a promising alternative diagnostic tool with better sensitivity and specificity than some current biomarker approaches. A dual filtration-based inductively coupled mass spectrometry (ICP-MS) assay to measure LBC in serum was developed. OBJECTIVE.­: To establish a reference interval for LBC and LBC to total copper (LBC fraction) in a healthy adult population, and to examine associations between total copper, LBC, and LBC fraction with age, sex, menopausal status, hormone replacement therapy, and supplement use. DESIGN.­: Serum samples were collected from healthy male (n = 110) and female (n = 104) patients between the ages of 19 and 80 years. Total copper and LBC were analyzed using ICP-MS. Results were used to calculate the LBC fraction. Reference intervals were calculated for the 2.5th and 97.5th percentiles for both LBC and LBC fraction. RESULTS.­: The reference intervals for LBC were determined to be 13 to 105 ng/mL and 12 to 107 ng/mL for female and male patients, respectively. The reference intervals for the LBC fraction were 1.0% to 8.1% and 1.2% to 10.5% for female and male patients, respectively. No significant associations were found regarding age, menopausal status, hormone replacement therapy, or vitamin and supplement use. CONCLUSIONS.­: Sex-specific reference intervals have now been established for LBC and LBC fraction. These data in conjunction with further testing of WD populations can be used to assess the sensitivity and specificity of LBC fraction in screening, monitoring, and diagnosis.

11.
Antimicrob Agents Chemother ; 67(11): e0081023, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37882514

RESUMEN

Cefepime exhibits highly variable pharmacokinetics in critically ill patients. The purpose of this study was to develop and qualify a population pharmacokinetic model for use in the critically ill and investigate the impact of various estimated glomerular filtration rate (eGFR) equations using creatinine, cystatin C, or both on model parameters. This was a prospective study of critically ill adults hospitalized at an academic medical center treated with intravenous cefepime. Individuals with acute kidney injury or on kidney replacement therapy or extracorporeal membrane oxygenation were excluded. A nonlinear mixed-effects population pharmacokinetic model was developed using data collected from 2018 to 2022. The 120 included individuals contributed 379 serum samples for analysis. A two-compartment pharmacokinetic model with first-order elimination best described the data. The population mean parameters (standard error) in the final model were 7.84 (0.24) L/h for CL1 and 15.6 (1.45) L for V1. Q was fixed at 7.09 L/h and V2 was fixed at 10.6 L, due to low observed interindividual variation in these parameters. The final model included weight as a covariate for volume of distribution and the eGFRcr-cysC (mL/min) as a predictor of drug clearance. In summary, a population pharmacokinetic model for cefepime was created for critically ill adults. The study demonstrated the importance of cystatin C to prediction of cefepime clearance. Cefepime dosing models which use an eGFR equation inclusive of cystatin C are likely to exhibit improved accuracy and precision compared to dosing models which incorporate an eGFR equation with only creatinine.


Asunto(s)
Antibacterianos , Cistatina C , Adulto , Humanos , Cefepima/farmacocinética , Tasa de Filtración Glomerular , Estudios Prospectivos , Enfermedad Crítica/terapia , Creatinina
12.
Clin Biochem ; 120: 110651, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37748668

RESUMEN

INTRODUCTION: Phosphatidylethanol (PEth) is a marker of alcohol consumption used in clinical and forensic settings. PEth positivity in individuals expected to abstain from alcohol can have serious consequences. PEth is located on erythrocytes, thus packed red blood cell (pRBC) transfusion is a potential cause of false-positive results. This report is the first to demonstrate this phenomenon in an authentic patient who was negative for PEth immediately prior to transfusion. METHODS: Residual blood samples collected for clinical testing before and after pRBC transfusion and citrated pRBC segments were tested for PEth homologues 16:0/18:1 (POPEth) and 16:0/18:2 (PLPEth) by liquid chromatography - tandem mass spectrometry with limit of quantitation 10 ng/mL (0.01 µmol/L). CASE: A 56-year-old male with new-onset leukemia required transfusion of 4 pRBC units on hospital days 1-2. Blood collected at admission (day 0) showed POPEth and PLPEth < 10 ng/mL (<0.01 µmol/L). Blood collected after completion of the fourth pRBC transfusion demonstrated POPEth = 57 ng/mL (0.08 µmol/L), PLPEth = 38 ng/mL (0.05 µmol/L). One citrated segment demonstrated extremely elevated PEth, supporting pRBC transfusion as the source. DISCUSSION: This case demonstrates pRBC transfusion elevating PEth to concentrations associated with moderate alcohol consumption. Studies suggest that healthy individuals (potential donors) could have PEth concentrations sufficient to cause significant elevation of PEth from a single pRBC unit. This is concerning for populations such as liver transplant candidates who are required to abstain from alcohol, but whose disease sequelae may require pRBC transfusion. CONCLUSIONS: pRBC transfusion can artificially elevate PEth into clinically and forensically relevant ranges. Individuals interpreting toxicology testing should consider recent pRBC transfusion when evaluating PEth concentrations.

13.
J Am Coll Clin Pharm ; 6(8): 964-975, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37731602

RESUMEN

Beta-lactam therapeutic drug monitoring (TDM) can improve precision dosing and clinical outcomes in critically ill patients, but has not been implemented widely in the United States. Mayo Clinic recently implemented a beta-lactam TDM program. This single-center experience forms the basis of the manuscript which outlines practical considerations involved with implementation, including the pharmacist's role as a leader. Our implementation effort focused on three primary domains. First, we aimed to ensure a supportive organizational infrastructure. Early leadership engagement by the pharmacist-led core team facilitated advocacy for the clinical need, allocation of resources, and assay development. Second, core clinical workflows were developed that addressed the preferred patient population for use, desirable pharmacokinetic and pharmacodynamic targets, and the preferred sampling strategy. Clinical tools to guide pharmacists in interpreting the results (e.g., pharmacokinetics calculator) and documenting decisions were developed. Third, stakeholders were offered repeated exposure to evidence and expertise to facilitate understanding and application of the new practice. This act of 'individual internalization' seems to be uniquely important to beta-lactam TDM implementation compared with implementation of other antimicrobial TDM programs. Educational strategies and supportive materials that were developed were focused on providing substantive and varied information tailored to the stakeholders' role in the process. For pharmacists, this included both clinical and operational considerations. A continuous improvement plan to support management of the process was instituted to address necessary updates and changes that inevitably emerged. In summary, the described approach to implementation of a pharmacist led beta-lactam TDM program could be used as a roadmap to aid other institutions that aim to develop such a program.

14.
Artículo en Inglés | MEDLINE | ID: mdl-37714050

RESUMEN

Phosphatidylethanol (PEth) is a group of phospholipids formed exclusively in the presence of ethanol on the erythrocyte membrane, making it a direct biomarker for long-term ethanol consumption for which a clinical reference interval has been established. Here, we describe an assay for quantitation for two most abundant PEth homologues, PEth 16:0/18:1 and PEth 16:0/18:2, from human whole blood, and present challenges overcome throughout the development process. Since PEth is localized within erythrocyte membranes, a reliable sample preparation technique is an important aspect of PEth analysis. Therefore, various erythrocyte lysing agents for recovery of exogenously spiked standards and controls were evaluated to identify one that performed comparably to the recovery of endogenous analytes found in authentic samples. A supported liquid extraction (SLE) technique was employed for sample cleanup and enrichment which together with liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis enabled automated sample preparation, appropriate chromatographic resolution, and minimal system carryover. This resulted in a laboratory developed test with an analytical measurement range (AMR) of 10-1000 ng/mL (slope = 0.9902-1.0138, R2 = 0.9958-0.9972), that was precise (intra-day precision: 3.4-4.1%; inter-day precision: 4.4-8.2% over the AMR), accurate when compared with an available external laboratory test (slope = 0.9943-1.0206, R2 = 0.9635-0.9678, no lower decision point interpretation changes), with effective analyte recovery (77.2-83.5%), and established stability characteristics, while chromatographically separating the analytes to ensure no additive effects due to the isotopic distribution of the opposing analyte.


Asunto(s)
Glicerofosfolípidos , Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida , Espectrometría de Masas en Tándem/métodos , Etanol , Biomarcadores
15.
Med Mycol ; 61(8)2023 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-37537152

RESUMEN

Posaconazole therapeutic drug monitoring (TDM) is widely utilized to assess therapeutic efficacy and safety; however, clinical effects of very high serum concentrations are unknown. A retrospective review of 90 patients receiving posaconazole for treatment or prophylaxis of invasive fungal infections with serum concentrations ≥3000 ng/mL from 1/1/2019 to 4/30/2021 evaluated the incidence and type of adverse drug reactions (ADRs). Symptomatic ADRs were very common in patients with posaconazole concentrations of ≥5000 ng/mL and 3000-4999 ng/mL (80% vs. 58.8%; P = 0.31). Posaconazole TDM should be performed for both treatment and prophylaxis indications and dose decrease for serum concentrations >3000 ng/mL should be considered.


Drug level monitoring is commonly used to evaluate appropriate dosing and effectiveness of posaconazole, a medication used to treat fungal infections. Patients with high levels commonly had side effects. Posaconazole monitoring should be completed, and doses reduced when levels are high.


Asunto(s)
Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Infecciones Fúngicas Invasoras , Animales , Antifúngicos/efectos adversos , Infecciones Fúngicas Invasoras/tratamiento farmacológico , Infecciones Fúngicas Invasoras/prevención & control , Infecciones Fúngicas Invasoras/veterinaria , Estudios Retrospectivos , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/epidemiología , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/veterinaria
16.
J Alzheimers Dis ; 94(4): 1335-1342, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37393495

RESUMEN

Total joint arthroplasty (TJA) implants are composed of metals, ceramics, and/or polyethylene. Studies suggest that the debris released from metal implants may possess neurotoxic properties with reports of neuropsychiatric symptoms and memory deficits, which could be relevant to Alzheimer's disease and related dementias. This exploratory study examined the cross-sectional correlation of blood metal concentrations with cognitive performance and neuroimaging findings in a convenience sample of 113 TJA patients with history of elevated blood metal concentrations of either titanium, cobalt and/or chromium. Associations with neuroimaging measures were observed but not with cognitive scores. Larger studies with longitudinal follow-up are warranted.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Estudios Transversales , Artroplastia de Reemplazo de Cadera/métodos , Metales , Neuroimagen , Cognición
17.
J Rural Med ; 18(2): 149-153, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37032984

RESUMEN

Arsenic cannot be tasted, seen or smelled and can vary in concentration between water wells even in condensed areas. American domestic well water is not regulated to meet the same drinking water standards as other types of water supplies and often contains arsenic. If arsenic is not detected in a well water sample, it is unlikely to be found later. Conversely, if it is detected in a new well, it is recommended to retest six months later as levels may fluctuate in the first months following well construction. It is up to the well owner to test their water and remove arsenic through commercially available water filters. If it is not detected and removed via filtration, a variety of serious, yet common, medical conditions may arise from chronic arsenic exposure, some of which are life-threatening. These include diabetes mellitus, hypertension, skin cancer, renal, bladder and lung cancers, polyneuropathy and cardiac QTc prolongation. Testing is best done through urine speciation if an initial total urine arsenic concentration is elevated. Consider a complete blood count, renal and liver function tests, an electrocardiogram as well as a urinalysis assessing for evidence of hematuria when examining patients with histories concerning for chronic arsenic exposure.

18.
Ther Drug Monit ; 45(4): 508-518, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37076424

RESUMEN

BACKGROUND: Beta-lactam therapeutic drug monitoring (BL TDM; drug level testing) can facilitate improved outcomes in critically ill patients. However, only 10%-20% of hospitals have implemented BL TDM. This study aimed to characterize provider perceptions and key considerations for successfully implementing BL TDM. METHODS: This was a sequential mixed-methods study from 2020 to 2021 of diverse stakeholders at 3 academic medical centers with varying degrees of BL TDM implementation (not implemented, partially implemented, and fully implemented). Stakeholders were surveyed, and a proportion of participants completed semistructured interviews. Themes were identified, and findings were contextualized with implementation science frameworks. RESULTS: Most of the 138 survey respondents perceived that BL TDM was relevant to their practice and improved medication effectiveness and safety. Integrated with interview data from 30 individuals, 2 implementation themes were identified: individual internalization and organizational features. Individuals needed to internalize, make sense of, and agree to BL TDM implementation, which was positively influenced by repeated exposure to evidence and expertise. The process of internalization appeared more complex with BL TDM than with other antibiotics (ie, vancomycin). Organizational considerations relevant to BL TDM implementation (eg, infrastructure, personnel) were similar to those identified in other TDM settings. CONCLUSIONS: Broad enthusiasm for BL TDM among participants was found. Prior literature suggested that assay availability was the primary barrier to implementation; however, the data revealed many more individual and organizational attributes, which impacted the BL TDM implementation. Internalization should particularly be focused on to improve the adoption of this evidence-based practice.


Asunto(s)
Monitoreo de Drogas , beta-Lactamas , Humanos , beta-Lactamas/uso terapéutico , Monitoreo de Drogas/métodos , Enfermedad Crítica , Antibacterianos/uso terapéutico , Vancomicina/uso terapéutico
19.
Front Immunol ; 14: 1130209, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36993965

RESUMEN

Total joint arthroplasty (TJA) implants are composed of metal components. Although they are regarded safe, the long-term immunological effects of chronic exposure to the specific implant materials are unknown. We recruited 115 hip and/or knee TJA patients (mean age 68 years) who provided a blood draw for measurement of chromium, cobalt, titanium concentrations, inflammatory markers and systemic distribution of immune cells. We examined differences between the immune markers and the systemic concentrations of chromium, cobalt and titanium. CD66-b neutrophils, early natural killer cells (NK), and eosinophils were present in higher percentages in patients with chromium and cobalt concentrations greater than the median. The opposite pattern was observed with titanium where the percentages of CD66-b neutrophils, early NK, and eosinophils were higher in patients with undetectable titanium. Cobalt concentrations were positively correlated with a higher percentage of gamma delta T cells. Both chromium and cobalt concentrations were positively correlated with higher percentages of plasmablasts. Titanium concentrations were positively correlated with higher CD4 effector memory T cells, regulatory T cell count and Th1 CD4 helper cells. In this exploratory study, we observed altered distribution of immune cells in TJA patients with elevated systemic metal concentrations. Although these correlations were not strong, these exploratory findings warrant further investigation into the role of increased metals circulating in blood and its role in immune modulation.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Anciano , Titanio/farmacología , Estudios Transversales , Biomarcadores , Cromo , Cobalto/farmacología
20.
Clin Chem ; 69(4): 336-349, 2023 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-36945128

RESUMEN

BACKGROUND: Exposure to heavy metals is common as a result of environmental contamination of air, water, and soil as well as accumulation in food, tobacco, herbal medicines, and occupational contact. However, clinically relevant toxicity is much less prevalent. Toxic effects, when they occur, may present with non-specific symptoms, resulting in a very large differential for clinicians to consider. CONTENT: Arsenic, cadmium, lead, and mercury are four heavy metals with no biological role in humans. However, these metals are commonly used in industrial applications and consumer products. Since these elements are not biodegradeable, their potential toxic effects may be long-lasting within the environment. These heavy metals have the potential to accumulate in vital organs such as the brain, heart, and kidney where they may disrupt normal cellular functioning and if exposures are repetitive or of high concentration, toxicity may result. SUMMARY: The objective of this review is to provide an overview of arsenic, cadmium, lead, and mercury physical properties, common sources of exposure, basic toxicokinetics and health effects, and to review clinical guidelines and treatment strategies. Acute and chronic symptoms and recommended laboratory biomarker testing are also discussed.


Asunto(s)
Arsénico , Mercurio , Metales Pesados , Humanos , Arsénico/toxicidad , Cadmio/toxicidad , Mercurio/toxicidad , Metales Pesados/toxicidad , Contaminación Ambiental/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...