Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 85(11): 11E801, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430366

RESUMEN

Results from the operation of an electromagnetic valve, that does not incorporate ferromagnetic materials, are presented. Image currents induced on a conducting disc placed near a pancake solenoid cause it to move away from the solenoid and open the vacuum seal. A new and important design feature is the use of Lip Seals for the sliding piston. The pressure rise in the test chamber is measured directly using a fast time response Baratron gauge. The valve injects over 200 Torr l of nitrogen in less than 3 ms, which remains unchanged at moderate magnetic fields.

2.
Phys Rev Lett ; 107(16): 165005, 2011 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-22107397

RESUMEN

The first sustainment of toroidal plasma current of 50 kA at up to 3 times the injected currents, added in quadrature, using steady inductive helicity injection is described. Separatrix currents-currents not linking the helicity injectors-are sustained up to 40 kA. Decreases in the n=1 toroidal mode of the poloidal magnetic field at higher current amplifications indicate more quiescent, direct toroidal current drive. Results are achieved in HIT-SI (with a spheromak of major radius 0.3 m) during deuterium operations immediately after helium operation. These results represent a breakthrough in the development of this new current drive method for magnetic confinement fusion.

3.
Phys Rev Lett ; 104(9): 095003, 2010 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-20366991

RESUMEN

Transient coaxial helicity injection (CHI) started discharges in the National Spherical Torus Experiment (NSTX) have attained peak currents up to 300 kA and when coupled to induction, it has produced up to 200 kA additional current over inductive-only operation. CHI in NSTX has shown to be energetically quite efficient, producing a plasma current of about 10 A/J of capacitor bank energy. In addition, for the first time, the CHI-produced toroidal current that couples to induction continues to increase with the energy supplied by the CHI power supply at otherwise similar values of the injector flux, indicating the potential for substantial current generation capability by CHI in NSTX and in future toroidal devices.

4.
Phys Rev Lett ; 97(17): 175002, 2006 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-17155478

RESUMEN

A method of coaxial helicity injection has successfully produced a closed flux current without the use of the central solenoid in the NSTX device, on a size scale closer to a spherical torus reactor, for a proof-of-principle demonstration of this concept. For the first time, a remarkable 60 times current multiplication factor was achieved. Grad-Shafranov plasma equilibrium reconstructions are used to verify the existence of closed flux current. In some discharges the generated current persists for a surprisingly long time approximately 400 ms.

5.
Phys Rev Lett ; 97(11): 115003, 2006 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-17025894

RESUMEN

A spheromak is formed for the first time using a new steady state inductive helicity injection method. Using two inductive injectors with odd symmetry and oscillating at 5.8 kHz, a steady state spheromak with even symmetry is formed and sustained through nonlinear relaxation. A spheromak with about 13 kA of toroidal current is formed and sustained using about 3 MW of power. This is a much lower power threshold for spheromak production than required for electrode-based helicity injection. Internal magnetic probe data, including oscillations driven by the injectors, agree with the plasma being in the Taylor state. The agreement is remarkable considering the only fitting parameter is the amplitude of the spheromak component of the state.

6.
Phys Rev Lett ; 90(7): 075005, 2003 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-12633238

RESUMEN

The first successful results on the transfer of a coaxial helicity injection (CHI) produced discharge to inductive operation are reported. CHI-assisted plasma startup is more robust than inductive only operation. After hand off for inductive operation, the initial 90 kA of CHI-produced current drops to 40 kA, then ramps up to 170 kA, using only 30 mV s, more than 30% higher than that produced by induction alone. These significant performance enhancing results were obtained on the HIT-II spherical torus experiment (major/minor radius of 0.3/0.2 m).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...