Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
APMIS ; 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39113427

RESUMEN

Autoimmune polyendocrinopathy-candidiasis-ectodermal dystrophy (APECED) is an inborn error of immunity affecting both multiple endocrine organs and susceptibility to candidiasis, each with an autoimmune basis. Recently, high titer neutralizing anti-type I interferon (IFN) autoantibodies have been linked with increased severity of SARS-CoV-2 and varicella zoster virus infections in APECED patients. Examining immunity against cytomegalovirus (CMV), we found a higher prevalence of anti-CMV IgG antibodies in patients with APECED (N = 19) than in 44 healthy controls (90% vs 64%, p = 0.04); the similar difference in their IgG levels did not achieve significance (95 ± 74 vs 64 ± 35 IU/mL, ns.). In contrast, the frequency of CMV-specific T cells was lower (804 ± 718/million vs 1591 ± 972/million PBMC p = 0.03). We saw no correlations between levels of anti-CMV IgG and anti-IFN antibodies in APECED patients or in a separate cohort of patients with thymoma (n = 70), over 60% of whom also had anti-IFN antibodies. Our results suggest a dysregulated response to CMV in APECED patients and highlight immunodeficiency to viral infections as part of the disease spectrum.

2.
Scand J Immunol ; 99(4): e13353, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-39007994

RESUMEN

Lyme borreliosis, caused by Borrelia burgdorferi sensu lato, is the most common tickborne disease. Its neuronal form, neuroborreliosis, comprises 3 to 38% of borreliosis cases in Europe. Borrelia outer surface proteins and virulence factors, OspE and BBK32, have been previously reported to help cause infection by promoting attachment to human host epithelial cells and evading complement attack. We assessed the serological responses to BBK32 and OspE in 19 individuals diagnosed with neuroborreliosis to see whether antibodies that could both target the bacteria and neutralize the virulence mechanisms on the microbial surface emerge. Results evaluate levels of total protein, IgG and the chemokine CXCL13, a determinant for B-cell recruitment during neuroinflammation, in patients' cerebrospinal fluid samples. Antibody levels against BBK32 and OspE correlated with those against VlsE, a well-characterized diagnostic serological marker of the disease. A dual serological profile of the patients was observed. K-means clustering split the cohort into two discrete groups presenting distinct serological and CNS responses. One group contained young patients with low levels of anti-BBK32 and OspE antibodies. The other group showed stronger responses, possibly following prolonged infections or reinfections. Additionally, we assessed anti-ganglioside antibodies that could cause autoimmunity or complement dysregulation but observed that they did not correlate with neuroborreliosis in our patient cohort. The dual nature of antibody responses against the virulence factors BBK32 and OspE in neuroborreliosis patients may suggest the necessity of repeated exposures for efficient immune responses. Better protection could be achieved if the virulence factors were formulated into vaccines.


Asunto(s)
Anticuerpos Antibacterianos , Antígenos Bacterianos , Proteínas de la Membrana Bacteriana Externa , Borrelia burgdorferi , Neuroborreliosis de Lyme , Humanos , Neuroborreliosis de Lyme/inmunología , Neuroborreliosis de Lyme/sangre , Anticuerpos Antibacterianos/sangre , Anticuerpos Antibacterianos/inmunología , Proteínas de la Membrana Bacteriana Externa/inmunología , Persona de Mediana Edad , Femenino , Masculino , Adulto , Anciano , Borrelia burgdorferi/inmunología , Antígenos Bacterianos/inmunología , Factores de Virulencia/inmunología , Inmunoglobulina G/sangre , Inmunoglobulina G/inmunología , Quimiocina CXCL13/sangre , Quimiocina CXCL13/inmunología , Proteínas Bacterianas/inmunología , Formación de Anticuerpos/inmunología
3.
bioRxiv ; 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38746185

RESUMEN

The SARS-CoV-2 genome occupies a unique place in infection biology - it is the most highly sequenced genome on earth (making up over 20% of public sequencing datasets) with fine scale information on sampling date and geography, and has been subject to unprecedented intense analysis. As a result, these phylogenetic data are an incredibly valuable resource for science and public health. However, the vast majority of the data was sequenced by tiling amplicons across the full genome, with amplicon schemes that changed over the pandemic as mutations in the viral genome interacted with primer binding sites. In combination with the disparate set of genome assembly workflows and lack of consistent quality control (QC) processes, the current genomes have many systematic errors that have evolved with the virus and amplicon schemes. These errors have significant impacts on the phylogeny, and therefore over the last few years, many thousands of hours of researchers time has been spent in "eyeballing" trees, looking for artefacts, and then patching the tree. Given the huge value of this dataset, we therefore set out to reprocess the complete set of public raw sequence data in a rigorous amplicon-aware manner, and build a cleaner phylogeny. Here we provide a global tree of 3,960,704 samples, built from a consistently assembled set of high quality consensus sequences from all available public data as of March 2023, viewable at https://viridian.taxonium.org. Each genome was constructed using a novel assembly tool called Viridian (https://github.com/iqbal-lab-org/viridian), developed specifically to process amplicon sequence data, eliminating artefactual errors and mask the genome at low quality positions. We provide simulation and empirical validation of the methodology, and quantify the improvement in the phylogeny. Phase 2 of our project will address the fact that the data in the public archives is heavily geographically biased towards the Global North. We therefore have contributed new raw data to ENA/SRA from many countries including Ghana, Thailand, Laos, Sri Lanka, India, Argentina and Singapore. We will incorporate these, along with all public raw data submitted between March 2023 and the current day, into an updated set of assemblies, and phylogeny. We hope the tree, consensus sequences and Viridian will be a valuable resource for researchers.

4.
Microbiol Spectr ; 11(3): e0514422, 2023 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-37042772

RESUMEN

Central nervous system (CNS) infections such as meningitis and encephalitis are life-threatening conditions that demand hospital care and prompt identification of the causative agent. Since 2015, there has been only one CE-IVD-marked rapid multiplexed diagnostic assay in cassette format for bacterial and viral detection from cerebrospinal fluid (CSF): the BioFire FilmArray meningitis/encephalitis (ME) panel. In the beginning of 2022, Qiagen introduced the QIAstat-Dx meningitis/encephalitis panel. It is a CE-IVD-marked multiplex PCR cassette test intended for the identification of suspected infectious meningitis, encephalitis, or meningoencephalitis caused by bacterial, viral, or fungal pathogens. In this study, we evaluated patient and quality control samples using the QIAstat-Dx meningitis/encephalitis panel and compared the results to those of the BioFire FilmArray meningitis/encephalitis panel and reference methods (current routine analysis methods in our laboratory, PCR, or cultivation). The combined positive percent agreement between the two panel assays was 100%, and the negative percent agreement was 94%. We further compared specifically herpes simplex virus 1 (HSV-1), HSV-2, and varicella-zoster virus (VZV) dilution series using six commercial herpesvirus assays, including the two cassette tests. The results suggested that real-time PCR methods (with separate extraction) were the most sensitive methods. When comparing the cassette tests, the BioFire FilmArray meningitis/encephalitis panel produced more positive results than the QIAstat-Dx meningitis/encephalitis panel in the herpesvirus analyses. IMPORTANCE The diagnosis of infectious meningitis and encephalitis relies mostly on specific PCR and culturing methods, but commercial syndromic panel assays are bringing a change in diagnostics. With multiplexed analysis, the identification of the pathogen is potentially faster, and less sample material is needed. The novel QIAstat-Dx meningitis/encephalitis panel assay is intended for the rapid identification of pathogens from cerebrospinal fluid for suspected central nervous system (CNS) infection, which is a life-threatening condition and difficult to diagnose. We studied the performance of this panel assay using patient samples and dilution series of selected viruses. The evaluation data for this novel meningitis/encephalitis panel assay are useful for other clinical laboratories and organizations using or considering using this test.


Asunto(s)
Encefalitis , Meningitis , Virus , Humanos , Reacción en Cadena de la Polimerasa Multiplex/métodos , Meningitis/diagnóstico , Encefalitis/diagnóstico , Virus/genética , Bacterias
5.
J Clin Immunol ; 43(3): 653-661, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36512178

RESUMEN

Lymphocyte responses to mitogens constitute a key part of the diagnostics of combined immunodeficiency (CID). Currently, mostly radioactive thymidine incorporation and carboxyfluorescein diacetate succinimidyl ester (CFSE) dilution methods are used. Flow-cytometric assay for specific cell-mediated immune-response in activated whole blood (FASCIA) has been put forth as an easy-to-perform option for the measurement of lymphocyte responses with the advantage of recognizing different lymphocyte subtypes and avoiding the use of radioactive reagents. Our aim was to analyze retrospectively the usefulness of FASCIA in the diagnostics of CID. We included all lymphocyte stimulation tests done with FASCIA in HUSLAB (Helsinki, Finland) between February 2015 and September 2018 in our analysis. The cohort was divided into two groups according to the patients' final diagnoses: CID (n = 30) or non-CID (n = 159). We evaluated the stimulation responses with a combined FASCIA score (the average of all mitogen responses). The FASCIA score was significantly lower among the CID group compared to the other patients (p = 0.002), and in the ROC analysis, the AUC was 0.75 (p < 0.001) for the FASCIA score. When the three mitogens were analyzed separately, phytohemagglutinin (PHA) was best in separating patients with CID from non-CID (in the ROC analysis AUC 0.71, p = 0.001). Immunosuppressive medication affected the FASCIA result significantly and needs to be considered when evaluating the results. In conclusion, FASCIA can reliably detect the CID patients in the absence of immunosuppressive medication. It emerges as a method with many benefits compared to tests requiring radioactive reagents or the complicated CFSE staining.


Asunto(s)
Activación de Linfocitos , Mitógenos , Humanos , Estudios Retrospectivos , Linfocitos
6.
Pathog Immun ; 8(2): 74-87, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38347963

RESUMEN

Background: Lymphopenia is common in COVID-19. This has raised concerns that COVID-19 could affect the immune system akin to measles infection, which causes immune amnesia and a reduction in protective antibodies. Methods: We recruited COVID-19 patients (n = 59) in Helsinki, Finland, and collected plasma samples on 2 to 3 occasions during and after infection. We measured IgG antibodies to diphtheria toxin, tetanus toxoid, and pertussis toxin, along with total IgG, SARS-CoV-2 spike protein IgG, and neutralizing antibodies. We also surveyed the participants for up to 17 months for long-term impaired olfaction as a proxy for prolonged post-acute COVID-19 symptoms. Results: No significant differences were found in the unrelated vaccine responses while the serological response against COVID-19 was appropriate. During the acute phase of the disease, the SARSCoV-2 IgG levels were lower in outpatients when compared to inpatients. SARS-CoV-2 serology kinetics matched expectations. In the acute phase, anti-tetanus and anti-diphtheria IgG levels were lower in patients with prolonged impaired olfaction during follow up than in those without. Conclusions: We could not detect significant decline in overall humoral immunity during or after COVID-19 infection. In severe COVID-19, there appears to be a temporary decline in total IgG levels.

7.
Commun Med (Lond) ; 2: 65, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35698660

RESUMEN

Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused millions of infections and fatalities globally since its emergence in late 2019. The virus was first detected in Finland in January 2020, after which it rapidly spread among the populace in spring. However, compared to other European nations, Finland has had a low incidence of SARS-CoV-2. To gain insight into the origins and turnover of SARS-CoV-2 lineages circulating in Finland in 2020, we investigated the phylogeographic and -dynamic history of the virus. Methods: The origins of SARS-CoV-2 introductions were inferred via Travel-aware Bayesian time-measured phylogeographic analyses. Sequences for the analyses included virus genomes belonging to the B.1 lineage and with the D614G mutation from countries of likely origin, which were determined utilizing Google mobility data. We collected all available sequences from spring and fall peaks to study lineage dynamics. Results: We observed rapid turnover among Finnish lineages during this period. Clade 20C became the most prevalent among sequenced cases and was replaced by other strains in fall 2020. Bayesian phylogeographic reconstructions suggested 42 independent introductions into Finland during spring 2020, mainly from Italy, Austria, and Spain. Conclusions: A single introduction from Spain might have seeded one-third of cases in Finland during spring in 2020. The investigations of the original introductions of SARS-CoV-2 to Finland during the early stages of the pandemic and of the subsequent lineage dynamics could be utilized to assess the role of transboundary movements and the effects of early intervention and public health measures.

8.
J Clin Virol ; 153: 105219, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35753174

RESUMEN

BACKGROUND: Independent evaluations that deploy clinical patient samples are important in assessing the performance of commercial tests used for serological screening of viral hepatitis and HIV in clinical laboratories. OBJECTIVES: We compared the analytical performance of Abbott Architect i2000SR, Abbott Alinity i, DiaSorin Liaison XL, and Siemens Atellica for the following analytes: anti-HAV IgG/anti-HAV total, anti-HAV IgM, HBsAg, anti-HBc IgM, Anti-HBc, HBeAg, anti-HBe, anti-HBs, anti-HCV, and HIV Ag/Ab. In addition, anti-HBc IgM, HBeAg, and anti-HBe were evaluated for Abbott Architect, Abbott Alinity and DiaSorin Liaison. STUDY DESIGN: Pseudonymized clinical serum specimens (N = 98-200 for each analyte) were selected for the analysis according to their reactivity on the Abbott Architect. The results were compared against Abbott Architect and against consensus. RESULTS: A generally high agreement was observed between the tests. Abbott Alinity had the lowest anti-HAV IgG/total specificity (75.9% against Abbott Architect and 83.0% against consensus). The comparatively low sensitivity of Siemens Atellica (78.2%), Abbott Alinity (87.5%) and DiaSorin Liaison (89.3%) for anti-HAV IgM against Abbott Architect may reflect a higher false-positive rate of Abbott Architect. Particular variation was observed in the sensitivity values of anti-HBc, HBsAg and HIV Ag/Ab between the test methods. DiaSorin Liaison anti-HBs gave consistently higher values as compared to the other tests. CONCLUSIONS: The serodiagnostic methods for HIV and viral hepatitis of Abbott Architect, Abbott Alinity, DiaSorin Liaison, and Siemens Atellica performed well in comparison with each other. The observed differences between the tests will provide useful information for clinical laboratories in planning their workflows for screening and confirmation.


Asunto(s)
Infecciones por VIH , Hepatitis A , Infecciones por VIH/diagnóstico , Anticuerpos de Hepatitis A , Anticuerpos contra la Hepatitis B , Antígenos de Superficie de la Hepatitis B , Antígenos e de la Hepatitis B , Humanos , Inmunoglobulina G , Inmunoglobulina M , Sensibilidad y Especificidad
9.
Emerg Infect Dis ; 28(6): 1229-1232, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35378057

RESUMEN

Multiple introductions of SARS-COV-2 Omicron variant BA.1 and BA.1.1. lineages to Finland were detected in early December 2021. Within 3 weeks, Omicron overtook Delta as the most common variant in the capital region. Sequence analysis demonstrated the emergence and spread through community transmission of a large cluster of BA.1.1 virus.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/epidemiología , Finlandia/epidemiología , Humanos , SARS-CoV-2/genética
11.
Emerg Infect Dis ; 27(12): 3137-3141, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34708686

RESUMEN

Severe acute respiratory syndrome coronavirus 2 Alpha and Beta variants became dominant in Finland in spring 2021 but had diminished by summer. We used phylogenetic clustering to identify sources of spreading. We found that outbreaks were mostly seeded by a few introductions, highlighting the importance of surveillance and prevention policies.


Asunto(s)
COVID-19 , SARS-CoV-2 , Finlandia/epidemiología , Humanos , Incidencia , Filogenia
12.
Infect Dis (Lond) ; 53(9): 684-690, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33974504

RESUMEN

BACKGROUND: Cryptococcosis is one of the major causes of mortality among HIV patients worldwide. Though most often associated with late stage HIV infection/AIDS, a significant number of cases occur in other immunocompromised patients such as solid organ transplant recipients and patients with hematological malignancies. Immunocompromised patients are a heterogeneous group and their number increases constantly. Since little is known about the incidence and the clinical features of cryptococcosis in Northern Europe, our aim was to investigate the clinical characteristics of cryptococcosis patients in Finland. METHODS: We retrospectively reviewed the laboratory confirmed cryptococcosis cases in Finland during 2004-2018. Only those who were treated for cryptococcosis were included in the study. Initial laboratory findings and medical records were also collected. RESULTS: A total of 22 patients with cryptococcosis were included in our study. The annual incidence of cryptococcosis was 0.03 cases per 100,000 population. Ten patients were HIV-positive and 12 out of 22 were HIV-negative. Hematological malignancy was the most common underlying condition among HIV-negative patients. CONCLUSIONS: To our knowledge, this is the first study of the clinical presentation and incidence of cryptococcosis in Finland. We demonstrate that invasive cryptococcal infection occurs not only in HIV/AIDS patients or otherwise immunocompromised patients but also in immunocompetent individuals. Even though cryptococcosis is extremely rare in Finland, its recognition is important since the prognosis depends on rapid diagnostics and early antifungal therapy.


Asunto(s)
Criptococosis , Cryptococcus neoformans , Infecciones por VIH , Antifúngicos/uso terapéutico , Criptococosis/epidemiología , Finlandia/epidemiología , Infecciones por VIH/complicaciones , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/epidemiología , Humanos , Incidencia , Estudios Retrospectivos
13.
PLoS One ; 16(5): e0251661, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34019562

RESUMEN

BACKGROUND: Understanding the false negative rates of SARS-CoV-2 RT-PCR testing is pivotal for the management of the COVID-19 pandemic and it has implications for patient management. Our aim was to determine the real-life clinical sensitivity of SARS-CoV-2 RT-PCR. METHODS: This population-based retrospective study was conducted in March-April 2020 in the Helsinki Capital Region, Finland. Adults who were clinically suspected of SARS-CoV-2 infection and underwent SARS-CoV-2 RT-PCR testing, with sufficient data in their medical records for grading of clinical suspicion were eligible. In addition to examining the first RT-PCR test of repeat-tested individuals, we also used high clinical suspicion for COVID-19 as the reference standard for calculating the sensitivity of SARS-CoV-2 RT-PCR. RESULTS: All 1,194 inpatients (mean [SD] age, 63.2 [18.3] years; 45.2% women) admitted to COVID-19 cohort wards during the study period were included. The outpatient cohort of 1,814 individuals (mean [SD] age, 45.4 [17.2] years; 69.1% women) was sampled from epidemiological line lists by systematic quasi-random sampling. The sensitivity (95% CI) for laboratory confirmed cases (repeat-tested patients) was 85.7% (81.5-89.1%) inpatients; 95.5% (92.2-97.5%) outpatients, 89.9% (88.2-92.1%) all. When also patients that were graded as high suspicion but never tested positive were included in the denominator, the sensitivity (95% CI) was: 67.5% (62.9-71.9%) inpatients; 34.9% (31.4-38.5%) outpatients; 47.3% (44.4-50.3%) all. CONCLUSIONS: The clinical sensitivity of SARS-CoV-2 RT-PCR testing was only moderate at best. The relatively high false negative rates of SARS-CoV-2 RT-PCR testing need to be accounted for in clinical decision making, epidemiological interpretations, and when using RT-PCR as a reference for other tests.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/normas , Adulto , Anciano , Prueba de Ácido Nucleico para COVID-19/métodos , Reacciones Falso Negativas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Distribución Aleatoria , Juego de Reactivos para Diagnóstico/normas
14.
Vaccine ; 39(13): 1818-1825, 2021 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-33678453

RESUMEN

Persistence of immune memory in humans is a crucial yet poorly understood aspect of immunology. Here we have studied the effect of Puumala hantavirus infection on unrelated, pre-existing immune memory by studying T cell- and antibody responses against toxoid vaccine antigens of diphtheria, tetanus and pertussis in a cohort of 45 patients. We found that tetanus- and pertussis -specific IgG concentrations elevate during acute Puumala virus infection. Increase in vaccine IgG was associated with proliferation of heterologous T cells. Interestingly, increases in tetanus-specific IgG persisted a year after the infection while pertussis-specific IgG declined rapidly; a difference in IgG kinetics resembling the difference seen after vaccination against tetanus and pertussis. These results suggest that persistence of immune memory is facilitated by heterologous boosting of old memory during memory formation against newly encountered antigens. They also show that different toxoid antigens may be treated differently. Our study gives new insight into how immune memory formation may alter pre-existing immune memory, and also shows that heterologous immunity may have an impact on vaccination outcomes.


Asunto(s)
Vacunas contra Difteria, Tétanos y Tos Ferina Acelular , Difteria , Tétanos , Tos Ferina , Anticuerpos Antibacterianos , Vacuna contra Difteria, Tétanos y Tos Ferina , Humanos , Toxoide Tetánico , Toxoides
15.
J Mol Diagn ; 23(4): 407-416, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33486074

RESUMEN

Mitigation of the ongoing coronavirus disease 2019 (COVID-19) pandemic requires reliable and accessible laboratory diagnostic services. In this study, the performance of one laboratory-developed test (LDT) and two commercial tests, cobas SARS-CoV-2 (Roche) and Amplidiag COVID-19 (Mobidiag), were evaluated for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in respiratory specimens. A total of 183 specimens collected from suspected COVID-19 patients were studied with all three methods to compare their performance. In relation to the reference standard, which was established as the result obtained by two of the three studied methods, the positive percent agreement was highest for the cobas test (100%), followed by the Amplidiag test and the LDT (98.9%). The negative percent agreement was lowest for the cobas test (89.4%), followed by the Amplidiag test (98.8%), and the highest value was obtained for the LDT (100%). The dilution series of positive specimens, however, suggests significantly higher sensitivity for the cobas assay in comparison with the other two assays, and the low negative percent agreement value may be due to the same reason. In general, all tested assays performed adequately. Clinical laboratories need to be prepared for uninterrupted high-throughput testing during the coming months to mitigate the pandemic. To ensure no interruption, it is critical that clinical laboratories maintain several simultaneous platforms in their SARS-CoV-2 nucleic acid testing.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/virología , SARS-CoV-2/aislamiento & purificación , COVID-19/epidemiología , Humanos , Técnicas de Amplificación de Ácido Nucleico/métodos
17.
J Clin Virol ; 131: 104614, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32889495

RESUMEN

BACKGROUND: Rapid sample-to-answer tests for detection of SARS-CoV-2 are emerging and data on their relative performance is urgently needed. OBJECTIVES: We evaluated the analytical performance of two rapid nucleic acid tests, Cepheid Xpert® Xpress SARS-CoV-2 and Mobidiag Novodiag® Covid-19, in comparison to a combination reference of three large-scale PCR tests. Moreover, utility of the Novodiag® test in tertiary care emergency departments was assessed. RESULTS: In the preliminary evaluation, analysis of 90 respiratory samples resulted in 100% specificity and sensitivity for Xpert®, whereas analysis of 107 samples resulted in 93.4% sensitivity and 100% specificity for Novodiag®. Rapid SARS-CoV-2 testing with Novodiag® was made available for four tertiary care emergency departments in Helsinki, Finland between 18 and 31 May, coinciding with a rapidly declining epidemic phase. Altogether 361 respiratory specimens, together with relevant clinical data, were analyzed with Novodiag® and reference tests: 355/361 of the specimens were negative with both methods, and 1/361 was positive in Novodiag® and negative by the reference method. Of the 5 remaining specimens, two were negative with Novodiag®, but positive with the reference method with late Ct values. On average, a test result using Novodiag® was available nearly 8 hours earlier than that obtained with the large-scale PCR tests. CONCLUSIONS: While the performance of novel sample-to-answer PCR tests need to be carefully evaluated, they may provide timely and reliable results in detection of SARS-CoV-2 and thus facilitate patient management including effective cohorting.


Asunto(s)
Infecciones por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , Neumonía Viral/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Betacoronavirus , COVID-19 , Prueba de COVID-19 , Niño , Preescolar , Técnicas de Laboratorio Clínico , Servicio de Urgencia en Hospital/estadística & datos numéricos , Femenino , Finlandia , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Nasofaringe/virología , Pandemias , SARS-CoV-2 , Sensibilidad y Especificidad , Atención Terciaria de Salud/estadística & datos numéricos , Adulto Joven
19.
Front Immunol ; 11: 563073, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33505390

RESUMEN

Background: Human pregnancy alters profoundly the immune system. The local involvement and mechanisms of activation of the complement system in the cervicovaginal milieu during pregnancy and delivery remain unexplored. Objectives: To determine whether normal pregnancy and delivery are associated with local activation of complement or changes in the immunoglobulin profile in the cervix. Study Design: This study was designed to assess IgA, IgG, and complement activation in the cervicovaginal area in three groups of patients: i) 49 pregnant women (week 41+3-42+0) not in active labor, ii) 24 women in active labor (38+4-42+2), and iii) a control group of nonpregnant women (n=23) at child-bearing age. We collected mucosal samples from the lateral fornix of the vagina and external cervix during routine visits and delivery. The Western blot technique was used to detect complement C3 and its activation products. For semiquantitative analysis, the bands of the electrophoresed proteins in gels were digitized on a flatbed photo scanner and analyzed. IgA and IgG were analyzed by Western blotting and quantified by ELISA. One-way ANOVA and Tukey's Multiple Comparison tests were used for statistical comparisons. Results: A higher abundance but lower activation level of C3 in both the external cervix (P<0.001) and lateral fornix of the vagina (P<0.001) was observed during delivery (58 ± 22, n= 24) in comparison to the groups of nonpregnant (72 ± 13%; mean ± SD, n=23) and pregnant women (78 ± 22%, n=49). Complement activating IgG was detected in higher abundance than IgA in the cervicovaginal secretions of pregnant women. In a small proportion samples also C3-IgG complexes were detected. Conclusions: Our results reveal an unexpectedly strong activation of the complement system and the presence IgG immunoglobulins in the cervicovaginal area during pregnancy, active labor, and among nonpregnant women. In contrast to the higher amounts of C3 in the cervicovaginal secretions during labor, its activation level was lower. Complement activating IgG was detected in higher concentrations than IgA in the mucosal secretions during pregnancy and labor. Taken together our results imply the presence a locally operating humoral immune system in the cervicovaginal mucosa.


Asunto(s)
Cuello del Útero/inmunología , Activación de Complemento , Complemento C3/inmunología , Inmunidad Humoral , Parto/inmunología , Vagina/inmunología , Adolescente , Adulto , Moco del Cuello Uterino/inmunología , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Inmunoglobulina A/inmunología , Inmunoglobulina G/inmunología , Embarazo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...