Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
EJNMMI Res ; 14(1): 18, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38358425

RESUMEN

BACKGROUND: Distribution of mAbs into tumour tissue may occur via different processes contributing differently to the 89Zr-mAb uptake on PET. Target-specific binding in tumours is of main interest; however, non-specific irreversible uptake may also be present, which influences quantification. The aim was to investigate the presence of non-specific irreversible uptake in tumour tissue using Patlak linearization on 89Zr-immuno-PET data of biopsy-proven target-negative tumours. Data of two studies, including target status obtained from biopsies, were retrospectively analysed, and Patlak linearization provided the net rate of irreversible uptake (Ki). RESULTS: Two tumours were classified as CD20-negative and two as CD20-positive. Four tumours were classified as CEA-negative and nine as CEA-positive. Ki values of CD20-negative (0.43 µL/g/h and 0.92 µL/g/h) and CEA-negative tumours (mdn = 1.97 µL/g/h, interquartile range (IQR) = 1.50-2.39) were higher than zero. Median Ki values of target-negative tumours were lower than CD20-positive (1.87 µL/g/h and 1.90 µL/g/h) and CEA-positive tumours (mdn = 2.77 µL/g/h, IQR = 2.11-3.65). CONCLUSION: Biopsy-proven target-negative tumours showed irreversible uptake of 89Zr-mAbs measured in vivo using 89Zr-immuno-PET data, which suggests the presence of non-specific irreversible uptake in tumours. Consequently, for 89Zr-immuno-PET, even if the target is absent, a tumour-to-plasma ratio always increases over time.

2.
Eur J Nucl Med Mol Imaging ; 50(7): 1897-1905, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36820891

RESUMEN

PURPOSE: Positron emission tomography imaging of zirconium-89-labelled monoclonal antibodies (89Zr-Immuno-PET) allows for visualisation and quantification of antibody uptake in tumours in vivo. Patlak linearization provides distribution volume (VT) and nett influx rate (Ki) values, representing reversible and irreversible uptake, respectively. Standardised uptake value (SUV) and tumour-to-plasma/tumour-to-blood ratio (TPR/TBR) are often used, but their validity depends on the comparability of plasma kinetics and clearances. This study assesses the validity of SUV, TPR and TBR against Patlak Ki for quantifying irreversible 89Zr-Immuno-PET uptake in tumours. METHODS: Ten patients received 37 MBq 10 mg 89Zr-anti-EGFR with 500 mg/m2 unlabelled mAbs. Five patients received two doses of 37 MBq 89Zr-anti-HER3: 8-24 mg for the first administration and 24 mg-30 mg/kg for the second. Seven tumours from four patients showed 89Zr-anti-EGFR uptake, and 18 tumours from five patients showed 89Zr-anti-HER3 uptake. SUVpeak, TPRpeak and TBRpeak values were obtained from one to six days p.i. Patlak linearization was applied to tumour time activity curves and plasma samples to obtain Ki. RESULTS: For 89Zr-anti-EGFR, there was a small variability along the linear regression line between SUV (- 0.51-0.57), TPR (- 0.06‒0.11) and TBR (- 0.13‒0.16) on day 6 versus Ki. Similar doses of 89Zr-anti-HER3 showed similar variability for SUV (- 1.3‒1.0), TPR (- 1.1‒0.53) and TBR (- 1.5‒0.72) on day 5 versus Ki. However, for the second administration of 89Zr-anti-HER3 with a large variability in administered mass doses, SUV showed a larger variability (- 1.4‒2.3) along the regression line with Ki, which improved when using TPR (- 0.38-0.32) or TBR (- 0.56‒0.46). CONCLUSION: SUV, TPR and TBR at late time points were valid for quantifying irreversible lesional 89Zr-Immuno-PET uptake when constant mass doses were administered. However, for variable mass doses, only TPR and TBR provided reliable values for irreversible uptake, but not SUV, because SUV does not take patient and mass dose-specific plasma clearance into account.


Asunto(s)
Neoplasias , Tomografía de Emisión de Positrones , Humanos , Tomografía de Emisión de Positrones/métodos , Neoplasias/diagnóstico por imagen , Neoplasias/patología , Anticuerpos Monoclonales , Cinética , Circonio
3.
Blood Adv ; 7(2): 214-223, 2023 01 24.
Artículo en Inglés | MEDLINE | ID: mdl-36306337

RESUMEN

We investigated whether the outcome prediction of patients with aggressive B-cell lymphoma can be improved by combining clinical, molecular genotype, and radiomics features. MYC, BCL2, and BCL6 rearrangements were assessed using fluorescence in situ hybridization. Seventeen radiomics features were extracted from the baseline positron emission tomography-computed tomography of 323 patients, which included maximum standardized uptake value (SUVmax), SUVpeak, SUVmean, metabolic tumor volume (MTV), total lesion glycolysis, and 12 dissemination features pertaining to distance, differences in uptake and volume between lesions, respectively. Logistic regression with backward feature selection was used to predict progression after 2 years. The predictive value of (1) International Prognostic Index (IPI); (2) IPI plus MYC; (3) IPI, MYC, and MTV; (4) radiomics; and (5) MYC plus radiomics models were tested using the cross-validated area under the curve (CV-AUC) and positive predictive values (PPVs). IPI yielded a CV-AUC of 0.65 ± 0.07 with a PPV of 29.6%. The IPI plus MYC model yielded a CV-AUC of 0.68 ± 0.08. IPI, MYC, and MTV yielded a CV-AUC of 0.74 ± 0.08. The highest model performance of the radiomics model was observed for MTV combined with the maximum distance between the largest lesion and another lesion, the maximum difference in SUVpeak between 2 lesions, and the sum of distances between all lesions, yielding an improved CV-AUC of 0.77 ± 0.07. The same radiomics features were retained when adding MYC (CV-AUC, 0.77 ± 0.07). PPV was highest for the MYC plus radiomics model (50.0%) and increased by 20% compared with the IPI (29.6%). Adding radiomics features improved model performance and PPV and can, therefore, aid in identifying poor prognosis patients.


Asunto(s)
Linfoma de Células B Grandes Difuso , Proteínas Proto-Oncogénicas c-myc , Humanos , Reordenamiento Génico , Hibridación Fluorescente in Situ , Linfoma de Células B Grandes Difuso/diagnóstico por imagen , Linfoma de Células B Grandes Difuso/genética , Tomografía Computarizada por Tomografía de Emisión de Positrones , Pronóstico , Proteínas Proto-Oncogénicas c-myc/genética
4.
EJNMMI Res ; 12(1): 54, 2022 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-36065038

RESUMEN

PURPOSE: Zirconium-89-immuno-positron emission tomography (89Zr-immuno-PET) has enabled visualization of zirconium-89 labelled monoclonal antibody (89Zr-mAb) uptake in organs and tumors in vivo. Patlak linearization of 89Zr-immuno-PET quantification data allows for separation of reversible and irreversible uptake, by combining multiple blood samples and PET images at different days. As one can obtain only a limited number of blood samples and scans per patient, choosing the optimal time points is important. Tissue activity concentration curves were simulated to evaluate the effect of imaging time points on Patlak results, considering different time points, input functions, noise levels and levels of reversible and irreversible uptake. METHODS: Based on 89Zr-mAb input functions and reference values for reversible (VT) and irreversible (Ki) uptake from literature, multiple tissue activity curves were simulated. Three different 89Zr-mAb input functions, five time points between 24 and 192 h p.i., noise levels of 5, 10 and 15%, and three reference Ki and VT values were considered. Simulated Ki and VT were calculated (Patlak linearization) for a thousand repetitions. Accuracy and precision of Patlak linearization were evaluated by comparing simulated Ki and VT with reference values. RESULTS: Simulations showed that Ki is always underestimated. Inclusion of time point 24 h p.i. reduced bias and variability in VT, and slightly reduced bias and variability in Ki, as compared to combinations of three later time points. After inclusion of 24 h p.i., minimal differences were found in bias and variability between different combinations of later imaging time points, despite different input functions, noise levels and reference values. CONCLUSION: Inclusion of a blood sample and PET scan at 24 h p.i. improves accuracy and precision of Patlak results for 89Zr-immuno-PET; the exact timing of the two later time points is not critical.

6.
EJNMMI Phys ; 9(1): 16, 2022 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-35239050

RESUMEN

PURPOSE: Low photon count in 89Zr-Immuno-PET results in images with a low signal-to-noise ratio (SNR). Since PET radiomics are sensitive to noise, this study focuses on the impact of noise on radiomic features from 89Zr-Immuno-PET clinical images. We hypothesise that 89Zr-Immuno-PET derived radiomic features have: (1) noise-induced variability affecting their precision and (2) noise-induced bias affecting their accuracy. This study aims to identify those features that are not or only minimally affected by noise in terms of precision and accuracy. METHODS: Count-split 89Zr-Immuno-PET patient scans from previous studies with three different 89Zr-labelled monoclonal antibodies were used to extract radiomic features at 50% (S50p) and 25% (S25p) of their original counts. Tumour lesions were manually delineated on the original full-count 89Zr-Immuno-PET scans. Noise-induced variability and bias were assessed using intraclass correlation coefficient (ICC) and similarity distance metric (SDM), respectively. Based on the ICC and SDM values, the radiomic features were categorised as having poor [0, 0.5), moderate [0.5, 0.75), good [0.75, 0.9), or excellent [0.9, 1] precision and accuracy. The number of features classified into these categories was compared between the S50p and S25p images using Fisher's exact test. All p values < 0.01 were considered statistically significant. RESULTS: For S50p, a total of 92% and 90% features were classified as having good or excellent ICC and SDM respectively, while for S25p, these decreased to 81% and 31%. In total, 148 features (31%) showed robustness to noise with good or moderate ICC and SDM in both S50p and S25p. The number of features classified into the four ICC and SDM categories between S50p and S25p was significantly different statistically. CONCLUSION: Several radiomic features derived from low SNR 89Zr-Immuno-PET images exhibit noise-induced variability and/or bias. However, 196 features (43%) that show minimal noise-induced variability and bias in S50p images have been identified. These features are less affected by noise and are, therefore, suitable candidates to be further studied as prognostic and predictive quantitative biomarkers in 89Zr-Immuno-PET studies.

7.
Diagnostics (Basel) ; 12(3)2022 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-35328149

RESUMEN

Acquisition time and injected activity of 18F-fluorodeoxyglucose (18F-FDG) PET should ideally be reduced. However, this decreases the signal-to-noise ratio (SNR), which impairs the diagnostic value of these PET scans. In addition, 89Zr-antibody PET is known to have a low SNR. To improve the diagnostic value of these scans, a Convolutional Neural Network (CNN) denoising method is proposed. The aim of this study was therefore to develop CNNs to increase SNR for low-count 18F-FDG and 89Zr-antibody PET. Super-low-count, low-count and full-count 18F-FDG PET scans from 60 primary lung cancer patients and full-count 89Zr-rituximab PET scans from five patients with non-Hodgkin lymphoma were acquired. CNNs were built to capture the features and to denoise the PET scans. Additionally, Gaussian smoothing (GS) and Bilateral filtering (BF) were evaluated. The performance of the denoising approaches was assessed based on the tumour recovery coefficient (TRC), coefficient of variance (COV; level of noise), and a qualitative assessment by two nuclear medicine physicians. The CNNs had a higher TRC and comparable or lower COV to GS and BF and was also the preferred method of the two observers for both 18F-FDG and 89Zr-rituximab PET. The CNNs improved the SNR of low-count 18F-FDG and 89Zr-rituximab PET, with almost similar or better clinical performance than the full-count PET, respectively. Additionally, the CNNs showed better performance than GS and BF.

8.
EJNMMI Res ; 11(1): 74, 2021 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-34417917

RESUMEN

BACKGROUND: 89Zirconium-immuno-positron emission tomography (89Zr-immuno-PET) is used for assessment of target status to guide antibody-based therapy. We aim to determine the relation between antibody tumor uptake and target concentration to improve future study design and interpretation. METHODS: The relation between tumor uptake and target concentration was predicted by mathematical modeling of 89Zr-labeled antibody disposition in the tumor. Literature values for trastuzumab kinetics were used to provide an example. RESULTS: 89Zr-trastuzumab uptake initially increases with increasing target concentration, until it levels off to a constant value. This is determined by the total administered mass dose of trastuzumab. For a commonly used imaging dose of 50 mg 89Zr-trastuzumab, uptake can discriminate between immunohistochemistry score (IHC) 0 versus 1-2-3. CONCLUSION: The example for 89Zr-trastuzumab illustrates the potential to assess target expression. The pitfall of false-positive findings depends on the cut-off to define clinical target positivity (i.e., IHC 3) and the administered mass dose.

9.
Mol Imaging Biol ; 22(4): 1102-1110, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31993925

RESUMEN

PURPOSE: This pilot study aimed to determine interobserver reliability and ease of use of three workflows for measuring metabolic tumor volume (MTV) and total lesion glycolysis (TLG) in diffuse large B cell lymphoma (DLBCL). PROCEDURES: Twelve baseline [18F]FDG PET/CT scans from DLBCL patients with wide variation in number and size of involved organs and lymph nodes were selected from the international PETRA consortium database. Three observers analyzed scans using three workflows. Workflow A: user-defined selection of individual lesions followed by four automated segmentations (41%SUVmax, A50%SUVpeak, SUV≥2.5, SUV≥4.0). For each lesion, observers indicated their "preferred segmentation." Individually selected lesions were summed to yield total MTV and TLG. Workflow B: fully automated preselection of [18F]FDG-avid structures (SUV≥4.0 and volume≥3ml), followed by removing non-tumor regions with single mouse clicks. Workflow C: preselected volumes based on Workflow B modified by manually adding lesions or removing physiological uptake, subsequently checked by experienced nuclear medicine physicians. Workflow C was performed 3 months later to avoid recall bias from the initial Workflow B analysis. Interobserver reliability was expressed as intraclass correlation coefficients (ICC). RESULTS: Highest interobserver reliability in Workflow A was found for SUV≥2.5 and SUV≥4.0 methods (ICCs for MTV 0.96 and 0.94, respectively). SUV≥4.0 and A50%Peak were most and SUV≥2.5 was the least preferred segmentation method. Workflow B had an excellent interobserver reliability (ICC = 1.00) for MTV and TLG. Workflow C reduced the ICC for MTV and TLG to 0.92 and 0.97, respectively. Mean workflow analysis time per scan was 29, 7, and 22 min for A, B, and C, respectively. CONCLUSIONS: Improved interobserver reliability and ease of use occurred using fully automated preselection (using SUV≥4.0 and volume≥3ml, Workflow B) compared with individual lesion selection by observers (Workflow A). Subsequent manual modification was necessary for some patients but reduced interobserver reliability which may need to be balanced against potential improvement on prognostic accuracy.


Asunto(s)
Linfoma de Células B Grandes Difuso/patología , Carga Tumoral , Automatización , Glucólisis , Humanos , Variaciones Dependientes del Observador , Factores de Tiempo , Flujo de Trabajo
10.
J Nucl Med ; 60(12): 1825-1832, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31147401

RESUMEN

89Zr-immuno-PET is a promising noninvasive clinical tool that measures target engagement of monoclonal antibodies (mAbs) to predict toxicity in normal tissues and efficacy in tumors. Quantification of 89Zr-immuno-PET will need to move beyond SUVs, since total uptake may contain a significant non-target-specific contribution. Nonspecific uptake is reversible (e.g., blood volume) or irreversible (due to 89Zr-residualization after mAb degradation). The aim of this study was to assess nonspecific uptake in normal tissues as a first critical step toward quantification of target engagement in normal tissues and tumors using 89Zr-immuno-PET. Methods: Data from clinical studies with 4 89Zr-labeled intact IgG1 antibodies were collected, resulting in a total of 128 PET scans (1-7 d after injection from 36 patients: 89Zr-obinutuzumab [n = 9], 89Zr-cetuximab [n = 7], 89Zr-huJ591 [n = 10], and 89Zr-trastuzumab [n = 10] [denoted as 89Zr-anti-CD20, 89Zr-anti-EGFR, 89Zr-anti-PSMA and 89Zr-anti-HER2, respectively]). Nonspecific uptake was defined as uptake measured in tissues without known target expression. Patlak graphical evaluation of transfer constants was used to estimate the reversible (Vt ) and irreversible (Ki ) contributions to the total measured uptake for the kidney, liver, lung, and spleen. Baseline values were calculated per tissue combining all mAbs without target expression (kidney: 89Zr-anti-CD20, 89Zr-anti-EGFR, and 89Zr-anti-HER2; liver: 89Zr-anti-CD20; lung: 89Zr-anti-CD20, 89Zr-anti-EGFR, and 89Zr-anti-PSMA; spleen: 89Zr-anti-EGFR and 89Zr-anti-HER2). Results: For the kidney, liver, lung, and spleen, baseline Vt was 0.20, 0.24, 0.09, and 0.24 mL⋅cm-3, respectively, and baseline Ki was 0.7, 1.1, 0.2 and 0.5 µL⋅g-1⋅h-1, respectively. For 89Zr-anti-PSMA, a 4-fold higher Ki was observed for the kidney, indicating target engagement. In this case, nonspecific uptake accounted for 66%, 34%, and 22% of the total signal in the kidney at 1, 3, and 7 d after injection, respectively. Conclusion: This study shows that nonspecific uptake of mAbs for tissues without target expression can be quantified using 89Zr-immuno-PET at multiple time points. These results form a crucial base for measurement of target engagement by therapeutic antibodies in vivo with 89Zr-immuno-PET. For future studies, a pilot phase including at least 3 scans at 1 or more days after injection is required to assess nonspecific uptake as a function of time, to optimize study design for detection of target engagement.


Asunto(s)
Anticuerpos Monoclonales/uso terapéutico , Tomografía de Emisión de Positrones/métodos , Radioisótopos , Circonio , Fluorodesoxiglucosa F18 , Humanos
11.
Eur J Nucl Med Mol Imaging ; 46(9): 1840-1849, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31209514

RESUMEN

PURPOSE: In-vivo quantification of tumor uptake of 89-zirconium (89Zr)-labelled monoclonal antibodies (mAbs) with PET provides a potential tool in strategies to optimize tumor targeting and therapeutic efficacy. A specific challenge for 89Zr-immuno-PET is low tumor contrast. This is expected to result in interobserver variation in tumor delineation. Therefore, the aim of this study was to determine interobserver reproducibility of tumor uptake measures by tumor delineation on 89Zr-immuno-PET scans. METHODS: Data were obtained from previously published clinical studies performed with 89Zr-rituximab, 89Zr-cetuximab and 89Zr-trastuzumab. Tumor lesions on 89Zr-immuno-PET were identified as focal uptake exceeding local background by a nuclear medicine physician. Three observers independently manually delineated volumes of interest (VOI). Maximum, peak and mean standardized uptake values (SUVmax, SUVpeak and SUVmean) were used to quantify tumor uptake. Interobserver variability was expressed as the coefficient of variation (CoV). The performance of semi-automatic VOI delineation using 50% of background-corrected ACpeak was described. RESULTS: In total, 103 VOI were delineated (3-6 days post injection (D3-D6)). Tumor uptake (median, interquartile range) was 9.2 (5.2-12.6), 6.9 (4.0-9.6) and 5.5 (3.3-7.8) for SUVmax, SUVpeak and SUVmean. Interobserver variability was 0% (0-12), 0% (0-2) and 7% (5-14), respectively (n = 103). The success rate of the semi-automatic method was 45%. Inclusion of background was the main reason for failure of semi-automatic VOI. CONCLUSIONS: This study shows that interobserver reproducibility of tumor uptake quantification on 89Zr-immuno-PET was excellent for SUVmax and SUVpeak using a standardized manual procedure for tumor segmentation. Semi-automatic delineation was not robust due to limited tumor contrast.


Asunto(s)
Anticuerpos Monoclonales/metabolismo , Linfoma de Células B/diagnóstico por imagen , Linfoma de Células B/metabolismo , Tomografía de Emisión de Positrones , Radioisótopos , Circonio , Adulto , Anciano , Transporte Biológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Retrospectivos
12.
Mol Imaging Biol ; 20(6): 1025-1034, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29713958

RESUMEN

PURPOSE: Positron emission tomography (PET) with Zirconium-89 (Zr-89)-labeled antibodies can be used for in vivo quantification of antibody uptake. Knowledge about measurement variability is required to ensure correct interpretation. However, no clinical studies have been reported on measurement variability of Zr-89 immuno-PET. As variability due to low signal-to-noise is part of the total measurement variability, the aim of this study was to assess noise-induced variability of Zr-89 -immuno-PET using count-reduced clinical images. PROCEDURES: Data were acquired from three previously reported clinical studies with [89Zr]antiCD20 (74 MBq, n = 7), [89Zr]antiEGFR (37 MBq, n = 7), and [89Zr]antiCD44 (37 MBq, n = 13), with imaging obtained 1 to 6 days post injection (D0-D6). Volumes of interest (VOIs) were manually delineated for liver, spleen, kidney, lung, brain, and tumor. For blood pool and bone marrow, fixed-size VOIs were used. Original PET list mode data were split and reconstructed, resulting in two count-reduced images at 50 % of the original injected dose (e.g., 37 MBq74inj). Repeatability coefficients (RC) were obtained from Bland-Altman analysis on standardized uptake values (SUV) derived from VOIs applied to these images. RESULTS: The RC for the combined manually delineated organs for [89Zr] antiCD20 (37 MBq74inj) increased from D0 to D6 and was less than 6 % at all time points. Blood pool and bone marrow had higher RC, up to 43 % for 37 MBq74inj at D6. For tumor, the RC was up to 42 % for [89Zr]antiCD20 (37 MBq74inj). For [89Zr]antiCD20, (18 MBq74inj), [89Zr]antiEGFR (18 MBq37inj), and [89Zr]antiCD44 (18 MBq37inj), measurement variability was independent of the investigated antibody. CONCLUSIONS: Based on this study, noise-induced variability results in a RC for Zr-89-immuno-PET (37 MBq) around 6 % for manually delineated organs combined, increasing up to 43 % at D6 for blood pool and bone marrow, assuming similar biodistribution of antibodies. The signal-to-noise ratio leads to tumor RC up to 42 %.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Tomografía de Emisión de Positrones/métodos , Radioisótopos/química , Circonio/química , Humanos , Neoplasias/metabolismo , Neoplasias/patología , Reproducibilidad de los Resultados
13.
EJNMMI Res ; 8(1): 6, 2018 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-29356983

RESUMEN

BACKGROUND: Ideally, monoclonal antibodies provide selective treatment by targeting the tumour, without affecting normal tissues. Therefore, antibody imaging is of interest, preferably in early stages of drug development. However, the imaging signal consists of specific, as well as non-specific, uptake. The aim of this study was to assess specific, target-mediated uptake in normal tissues, with immuno-PET in a phase I dose escalation study, using the anti-CD44 antibody RG7356 as example. RESULTS: Data from thirteen patients with CD44-expressing solid tumours included in an imaging sub-study of a phase I dose escalation clinical trial using the anti-CD44 antibody RG7356 was analysed. 89Zirconium-labelled RG7356 (1 mg; 37 MBq) was administered after a variable dose of unlabelled RG7356 (0 to 675 mg). Tracer uptake in normal tissues (liver, spleen, kidney, lung, bone marrow, brain and blood pool) was used to calculate the area under the time antibody concentration curve (AUC) and expressed as tissue-to-blood AUC ratios. Within the dose range of 1 to 450 mg, tissue-to-blood AUC ratios decreased from 10.6 to 0.75 ± 0.16 for the spleen, 7.5 to 0.86 ± 0.18 for the liver, 3.6 to 0.48 ± 0.13 for the bone marrow, 0.69 to 0.26 ± 0.1 for the lung and 1.29 to 0.56 ± 0.14 for the kidney, indicating dose-dependent uptake. In all patients receiving ≥ 450 mg (n = 7), tumour uptake of the antibody was observed. CONCLUSIONS: This study demonstrates how immuno-PET in a dose escalation study provides a non-invasive technique to quantify dose-dependent uptake in normal tissues, indicating specific, target-mediated uptake.

14.
PLoS One ; 12(1): e0169828, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28060891

RESUMEN

PURPOSE: Treatment of patients with diffuse large B cell lymphoma (DLBCL) includes rituximab, an anti-CD20 monoclonal antibody (mAb). Insufficient tumor targeting might cause therapy failure. Tumor uptake of 89Zirconium (89Zr)-mAb is a potential imaging biomarker for tumor targeting, since it depends on target antigen expression and accessibility. The aim of this pilot study was to describe the performance of 89Zr-labeled-rituximab-PET to assess CD20 targeting in patients with relapsed/refractory DLBCL. METHODS: Six patients with biopsy-proven DLBCL were included. CD20 expression was assessed using immunohistochemistry (IHC). 74 MBq 89Zr-rituximab (10 mg) was administered after the therapeutic dose of rituximab. Immuno-PET scans on day 0, 3 and 6 post injection (D0, D3 and D6 respectively) were visually assessed and quantified for tumor uptake. RESULTS: Tumor uptake of 89Zr-rituximab and CD20 expression were concordant in 5 patients: for one patient, both were negative, for the other four patients visible tumor uptake was concordant with CD20-positive biopsies. Intense tumor uptake of 89Zr-rituximab on PET (SUVpeak = 12.8) corresponded with uniformly positive CD20 expression on IHC in one patient. Moderate tumor uptake of 89Zr-rituximab (range SUVpeak = 3.2-5.4) corresponded with positive CD20 expression on IHC in three patients. In one patient tumor uptake of 89Zr-rituximab was observed (SUVpeak = 3.8), while the biopsy was CD20-negative. CONCLUSIONS: This study suggests a positive correlation between tumor uptake of 89Zr-rituximab and CD20 expression in tumor biopsies, but further studies are needed to confirm this. This result supports the potential of 89Zr-rituximab-PET as an imaging biomarker for CD20 targeting. For clinical application of 89Zr-rituximab-PET to guide individualized treatment, further studies are required to assess whether tumor targeting is related to clinical benefit of rituximab treatment in individual patients.


Asunto(s)
Anticuerpos Monoclonales de Origen Murino , Linfoma de Células B Grandes Difuso/diagnóstico por imagen , Linfoma de Células B Grandes Difuso/patología , Tomografía de Emisión de Positrones , Adulto , Anciano , Antígenos CD20/metabolismo , Resistencia a Antineoplásicos , Femenino , Humanos , Linfoma de Células B Grandes Difuso/metabolismo , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Proyectos Piloto , Recurrencia , Reproducibilidad de los Resultados , Rituximab , Adulto Joven
15.
Front Pharmacol ; 7: 131, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27252651

RESUMEN

Selection of the right drug for the right patient is a promising approach to increase clinical benefit of targeted therapy with monoclonal antibodies (mAbs). Assessment of in vivo biodistribution and tumor targeting of mAbs to predict toxicity and efficacy is expected to guide individualized treatment and drug development. Molecular imaging with positron emission tomography (PET) using zirconium-89 ((89)Zr)-labeled monoclonal antibodies also known as (89)Zr-immuno-PET, visualizes and quantifies uptake of radiolabeled mAbs. This technique provides a potential imaging biomarker to assess target expression, as well as tumor targeting of mAbs. In this review we summarize results from initial clinical trials with (89)Zr-immuno-PET in oncology and discuss technical aspects of trial design. In clinical trials with (89)Zr-immuno-PET two requirements should be met for each (89)Zr-labeled mAb to realize its full potential. One requirement is that the biodistribution of the (89)Zr-labeled mAb (imaging dose) reflects the biodistribution of the drug during treatment (therapeutic dose). Another requirement is that tumor uptake of (89)Zr-mAb on PET is primarily driven by specific, antigen-mediated, tumor targeting. Initial trials have contributed toward the development of (89)Zr-immuno-PET as an imaging biomarker by showing correlation between uptake of (89)Zr-labeled mAbs on PET and target expression levels in biopsies. These results indicate that (89)Zr-immuno-PET reflects specific, antigen-mediated binding. (89)Zr-immuno-PET was shown to predict toxicity of RIT, but thus far results indicating that toxicity of mAbs or mAb-drug conjugate treatment can be predicted are lacking. So far, one study has shown that molecular imaging combined with early response assessment is able to predict response to treatment with the antibody-drug conjugate trastuzumab-emtansine, in patients with human epithelial growth factor-2 (HER2)-positive breast cancer. Future studies would benefit from a standardized criterion to define positive tumor uptake, possibly supported by quantitative analysis, and validated by linking imaging data with corresponding clinical outcome. Taken together, these results encourage further studies to develop (89)Zr-immuno-PET as a predictive imaging biomarker to guide individualized treatment, as well as for potential application in drug development.

16.
Am J Nucl Med Mol Imaging ; 4(3): 231-8, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24795837

RESUMEN

The purpose of this study was to determine the correlation between the (18)F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) standardized uptake value (SUV) and the diffusion-weighted magnetic resonance imaging (MRI) apparent diffusion coefficient (ADC) in newly diagnosed diffuse large B-cell lymphoma (DLBCL). Pretreatment FDG-PET and diffusion-weighted MRI of 21 patients with histologically proven DLBCL were prospectively analyzed. In each patient, maximum, mean and peak standardized uptake value (SUV) was measured in the lesion with visually highest FDG uptake and in the largest lesion. Mean ADC (ADCmean, calculated with b-values of 0 and 1000 s/mm(2)) was measured in the same lesions. Correlations between FDG-PET metrics (SUVmax, SUVmean, SUVpeak) and ADCmean were assessed using Pearson's correlation coefficients. In the lesions with visually highest FDG uptake, no significant correlations were found between the SUVmax, SUVmean, SUVpeak and the ADCmean (P=0.498, P=0.609 and P=0.595, respectively). In the largest lesions, there were no significant correlations either between the SUVmax, SUVmean, SUVpeak and the ADCmean (P=0.992, P=0.843 and P=0.894, respectively). The results of this study indicate that the glycolytic rate as measured by FDG-PET and changes in water compartmentalization and water diffusion as measured by the ADC are independent biological phenomena in newly diagnosed DLBCL. Further studies are warranted to assess the complementary roles of these different imaging biomarkers in the evaluation and follow-up of DLBCL.

17.
J Nucl Med ; 50(11): 1828-36, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19837762

RESUMEN

UNLABELLED: Immuno-PET is an appealing concept in the detection of tumors and planning of antibody-based therapy. For this purpose, the long-lived positron emitter (89)Zr (half-life, 78.4 h) recently became available. The aim of the present first-in-humans (89)Zr immuno-PET study was to assess safety, biodistribution, radiation dose, and quantification of the (89)Zr-labeled chimeric monoclonal antibody (cmAb) U36 in patients with head and neck squamous cell carcinoma (HNSCC). In addition, the performance of immuno-PET for detecting lymph node metastases was evaluated, as described previously. METHODS: Twenty HNSCC patients, scheduled to undergo surgical tumor resection, received 75 MBq of (89)Zr-cmAb U36 (10 mg). Immuno-PET scans were acquired at 1, 24, 72, or 144 h after injection. The biodistribution of the radioimmunoconjugate was evaluated by ex vivo radioactivity measurement in blood and in biopsies from the surgical specimen obtained at 168 h after injection. Uptake levels and residence times in blood, tumors, and organs of interest were derived from quantitative immuno-PET studies, and absorbed doses were calculated using OLINDA/EXM 1.0. The red marrow dose was calculated using the residence time for blood. RESULTS: (89)Zr-cmAb U36 was well tolerated by all subjects. PET quantification of blood-pool activity in the left ventricle of the heart showed a good agreement with sampled blood activity (difference equals 0.2% +/- 16.9% [mean +/- SD]) except for heavy-weight patients (>100 kg). A good agreement was also found for the assessment of mAb uptake in primary tumors (mean deviation, -8.4% +/- 34.5%). The mean absorbed red marrow dose was 0.07 +/- 0.02 mSv/MBq and 0.09 +/- 0.01 mSv/MBq in men and women, respectively. The normal organ with the highest absorbed dose was the liver (mean dose, 1.25 +/- 0.27 mSv/MBq in men and 1.35 +/- 0.21 mSv/MBq in women), thereafter followed by kidneys, thyroid, lungs, and spleen. The mean effective dose was 0.53 +/- 0.03 mSv/MBq in men and 0.66 +/- 0.03 mSv/MBq in women. Measured excretion via the urinary tract was less than 3% during the first 72 h. CONCLUSION: (89)Zr immuno-PET can be safely used to quantitatively assess biodistribution, uptake, organ residence times, and radiation dose, justifying its further clinical exploitation in the detection of tumors and planning of mAb-based therapy.


Asunto(s)
Anticuerpos Monoclonales/química , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/inmunología , Proteínas Recombinantes de Fusión/química , Circonio/química , Anciano , Anticuerpos Monoclonales/efectos adversos , Anticuerpos Monoclonales/farmacocinética , Médula Ósea/efectos de la radiación , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/inmunología , Carcinoma de Células Escamosas/metabolismo , Ensayos Clínicos como Asunto , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Femenino , Neoplasias de Cabeza y Cuello/metabolismo , Humanos , Marcaje Isotópico , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Dosis de Radiación , Radioisótopos , Radiometría , Proteínas Recombinantes de Fusión/efectos adversos , Proteínas Recombinantes de Fusión/farmacocinética , Distribución Tisular
18.
Clin Cancer Res ; 12(7 Pt 1): 2133-40, 2006 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-16609026

RESUMEN

PURPOSE: Immuno-positron emission tomography (PET), the combination of PET with monoclonal antibodies (mAb), is an attractive option to improve tumor detection and to guide mAb-based therapy. The long-lived positron emitter zirconium-89 ((89)Zr) has ideal physical characteristics for immuno-PET with intact mAbs but has never been used in a clinical setting. In the present feasibility study, we aimed to evaluate the diagnostic imaging performance of immuno-PET with (89)Zr-labeled-chimeric mAb (cmAb) U36 in patients with squamous cell carcinoma of the head and neck (HNSCC), who were at high risk of having neck lymph node metastases. EXPERIMENTAL DESIGN: Twenty HNSCC patients, scheduled to undergo neck dissection with or without resection of the primary tumor, received 75 MBq (89)Zr coupled to the anti-CD44v6 cmAb U36 (10 mg). All patients were examined by computed tomography (CT) and/or magnetic resonance imaging (MRI) and immuno-PET before surgery. Six patients also underwent PET with (18)F-fluoro-2-deoxy-d-glucose. Immuno-PET scans were acquired up to 144 hours after injection. Diagnostic findings were recorded per neck side (left or right) as well as per lymph node level (six levels per side), and compared with histopathologic outcome. For this purpose, the CT/MRI scores were combined and the best of both scores was used for analysis. RESULTS: Immuno-PET detected all primary tumors (n = 17) as well as lymph node metastases in 18 of 25 positive levels (sensitivity 72%) and in 11 of 15 positive sides (sensitivity 73%). Interpretation of immuno-PET was correct in 112 of 121 operated levels (accuracy 93%) and in 19 of 25 operated sides (accuracy 76%). For CT/MRI, sensitivities of 60% and 73% and accuracies of 90% and 80% were found per level and side, respectively. In the six patients with seven tumor-involved neck levels and sides, immuno-PET and (18)F-fluoro-2-deoxy-d-glucose PET gave comparable diagnostic results. CONCLUSION: In this study, immuno-PET with (89)Zr-cmAb U36 performed at least as good as CT/MRI for detection of HNSCC lymph node metastases.


Asunto(s)
Anticuerpos Monoclonales , Carcinoma de Células Escamosas/diagnóstico , Neoplasias de Cabeza y Cuello/diagnóstico , Tomografía de Emisión de Positrones/métodos , Radioisótopos , Circonio , Anciano , Anticuerpos Monoclonales/administración & dosificación , Carcinoma de Células Escamosas/secundario , Carcinoma de Células Escamosas/cirugía , Reacciones Falso Positivas , Femenino , Fluorodesoxiglucosa F18 , Neoplasias de Cabeza y Cuello/secundario , Neoplasias de Cabeza y Cuello/cirugía , Humanos , Marcaje Isotópico , Metástasis Linfática , Masculino , Persona de Mediana Edad , Disección del Cuello , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA