Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Integr Med (Encinitas) ; 22(6): 30-37, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38404609

RESUMEN

We report on 6 patients in our care who were harboring atherosclerotic plaque in the carotid arteries. This condition poses a risk of acute ischemic stroke and indicates potential atherosclerosis elsewhere in the vascular system. The plaque was revealed by routine ultrasound measurement of carotid intima-medial thickness (CIMT) defined as the distance between the lumen-intima interface and the media-adventitia interface. Recent improvements in image resolution and edge detection algorithms have resulted in improved reliability and clinical usefulness of the technology. The patients were enrolled in a systems-based functional medicine program of cardiology prevention to address root causes. The program provided personalized interventions that included drug therapy, dietary supplements, and lifestyle modification. The 6 patients followed the integrative regimen, which successfully managed existing cardiovascular symptoms and risk factors while keeping various biomarkers under control. However, they continued to exhibit carotid plaque with no improvement. A novel dietary supplement that targets endothelial glycocalyx regeneration was added to the personalized intervention programs. The supplement contains a proprietary extract of rhamnan sulfate from the green seaweed Monostroma nitidum. The 6 participants consumed the supplement daily, and their plaque burden was measured after 6 months using the same CIMT technology. In every case, the total plaque burden was reduced, with an average reduction in the 6 patients of 5.55 mm, which is statistically significant. Significant reductions in maximum carotid plaque thickness were also observed at the end of the 6 months. The study suggests that rhamnan sulfate from Monostroma nitidum may provide a safe and effective intervention for reducing atherosclerotic plaque, and should be evaluated as an adjunct therapy for prevention and treatment of cardiovascular disease.

2.
Semin Thromb Hemost ; 2023 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-37748519

RESUMEN

Internal quality control (IQC) for routine and specialist hemostasis testing represents a mandatory requirement for assays offered by clinical laboratories under International Organization for Standardization, Code of Federal Regulations, and Clinical and Laboratory Standards Institute standards. The underlying principle is that regular IQC audits the analytical performance of automated, semiautomated, and manual methods. This review investigates IQC practices, including benefits, limitations, frequency per time period or batch, sources of material used, primary supplier, third party or in-house, plus troubleshooting when IQC falls outside acceptance criteria. To assess IQC practice, the UK National External Quality Assessment Scheme (NEQAS) Blood Coagulation distributed a questionnaire to 1,200 participants enrolled in our scheme that collected details of the local practices for IQC testing. We received returns from 127 centers that described their local practices for the frequency of IQC, the type of IQC material employed, acceptance criteria for IQC data, and troubleshooting protocols for IQC failures. The data collected as part of an NEQAS BC questionnaire confirmed that all the participants returning answers to the questionnaire meet the standards for regular IQC testing for the hemostasis assays they perform.

3.
Proc Natl Acad Sci U S A ; 120(36): e2306414120, 2023 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-37643213

RESUMEN

Targeted inhibitors of bromodomain and extraterminal (BET)-bromodomains and phosphatidylinositol-3-kinase (PI3K) signaling demonstrate potent but self-limited antilymphoma activity as single agents in the context of cellular Myelocytomatosis (cMYC) oncogene-dysregulation. However, combined PI3K and BET inhibition imparts synergistic anticancer activity with the potential for more sustained disease responses due to the mutual antagonism of compensatory epigenetic and signaling networks. Here, we describe the mechanistic and therapeutic validation of rationally designed dual PI3K/BET bromodomain inhibitors, built by linkage of established PI3K and BET inhibitor pharmacophores. The lead candidate demonstrates high selectivity, nanomolar range cellular potency, and compelling in vivo efficacy, including curative responses in the aggressive Eµ-Myc lymphoma model. These studies further support the therapeutic strategy of combined PI3K and BET inhibition and provide a potential step-change in approach to orthogonal MYC antagonism using optimized chimeric small-molecule technology.


Asunto(s)
Linfoma , Fosfatidilinositol 3-Quinasas , Humanos , Fosfatidilinositol 3-Quinasa , Agresión , Epigenómica , Linfoma/tratamiento farmacológico , Inhibidores de las Quinasa Fosfoinosítidos-3
6.
Semin Thromb Hemost ; 48(6): 732-738, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36055268

RESUMEN

Von Willebrand disease (VWD) is one of the most common hereditary bleeding disorders. Effective management of patients and their families depends on accurate diagnosis and subtype classification, and quality assurance including participation in proficiency testing programs is essential to ensure the accuracy of the panel of assays required to achieve this diagnosis. We report here findings from recent external quality assessment (EQA) exercises, as well as from a questionnaire about diagnostic practices employed by centers in the United Kingdom National Quality Assessment Scheme (UK NEQAS) performing von Willebrand factor (VWF) assays. Plasma samples from donors with VWD, "normal" donors, the International Society for Thrombosis and Haemostasis Scientific Subcommittee (ISTH SSC) plasma standard, and whole blood samples were sent to participants in the UK NEQAS BC program for VWF investigation. Calibration of lot#5 of the ISTH SSC plasma standard was shown to give improved comparability between the recovered value from an EQA exercise and the assigned potency for VWF activity assays. Diagnostic accuracy and precision amongst UK NEQAS participants was good, with an average 99% of centers reporting the correct interpretation for normal, type 1 and type 2 VWD samples, 100% diagnostic accuracy for centers performing FVIII binding assays, and good agreement amongst centers performing multimeric analysis. Genetic analysis of the VWF gene by specialist centers demonstrated errors in the genotyping process in one center, but also demonstrated failings in the interpretation of results in other centers. Despite evidence of good laboratory accuracy and precision in their assays, a questionnaire identified marked variation in diagnostic criteria employed, underlining the importance of guidelines to support the diagnosis of VWD.


Asunto(s)
Enfermedad de von Willebrand Tipo 2 , Enfermedades de von Willebrand , Pruebas de Coagulación Sanguínea , Técnicas de Laboratorio Clínico , Humanos , Enfermedades de von Willebrand/diagnóstico , Factor de von Willebrand/genética , Factor de von Willebrand/metabolismo
7.
Bioorg Med Chem ; 69: 116832, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35752141

RESUMEN

A novel series of TGX-221 analogues was prepared that include isosteric replacement of the 4H-pyrido[1,2-a]pyrimidin-4-one with a 4H-benzo[e][1,3]oxazin-4-one scaffold. The compounds that included an CH(CH3)NH type linker showed comparable activity to TGX-221 analogues with the isosterism supported by the comparative SAR analysis. The analogues containing an CH(CH3)O linker were less active but still showed useful SAR including a favoured o-methyl substitution.


Asunto(s)
Morfolinas , Pirimidinonas , Pirimidinonas/farmacología , Relación Estructura-Actividad
8.
J Thromb Haemost ; 20(8): 1875-1879, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35603519

RESUMEN

BACKGROUND: Vaccine-induced immune thrombocytopenia and thrombosis (VITT) following the administration of the AstraZeneca (AZ) ChAdOx1 nCOV-19 vaccine is a well recognized clinical phenomenon. The associated clinical and laboratory features have included thrombosis at unusual sites, thrombocytopenia, raised D-dimer levels and positivity for immunoglobulin G (IgG) anti-platelet factor 4 (PF4) antibodies. OBJECTIVES: A collaborative external quality assessment (EQA) exercise was carried out by distributing five lyophilized samples from subjects with VITT and one from a healthy subject to 500 centers performing heparin-induced thrombocytopenia (HIT) testing. METHODS: Participating centers employed their locally validated testing methods for HIT assays, with some participants additionally reporting results for VITT modified assays. RESULTS: A total of 385 centers returned results for anti-PF4 immunoassay and functional assays. The ELISA assays used in the detection of anti-PF4 antibodies for the samples distributed had superior sensitivities compared with both the functional assays and the non-ELISA methods. CONCLUSION: ELISA-based methods to detect anti PF4 antibodies have a greater sensitivity in confirmation of VITT compared with functional assays regardless of whether such functional assays were modified to be specific for VITT. Rapid immunoassays should not be employed to detect VITT antibodies.


Asunto(s)
ChAdOx1 nCoV-19 , Factor Plaquetario 4 , Púrpura Trombocitopénica Idiopática , Trombocitopenia , Trombosis , ChAdOx1 nCoV-19/efectos adversos , Heparina/efectos adversos , Humanos , Inmunoglobulina G , Factores Inmunológicos/efectos adversos , Púrpura Trombocitopénica Idiopática/inducido químicamente , Púrpura Trombocitopénica Idiopática/diagnóstico , Trombocitopenia/inducido químicamente , Trombocitopenia/diagnóstico , Trombosis/diagnóstico , Trombosis/etiología
9.
Int J Lab Hematol ; 44(3): 619-625, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35040275

RESUMEN

INTRODUCTION: There may be clinically relevant differences between results of different FIX assays in samples containing extended half life FIX concentrates requiring regular surveillance of assay results through proficiency testing exercises. Control materials used in proficiency testing must be commutable, that is have the same inter-assay properties as those demonstrated by authentic clinical samples when measured by different analytical methods. METHODS: We assessed relationships between results with different FIX assays and commutability of UK National External Quality Assessment Scheme (NEQAS) materials containing rIX-FP (Idelvion) or rFIXFc (Alprolix) by comparing results obtained using widely used one-stage and chromogenic assays during a proficiency testing exercise with results obtained when analysing a series of individual patient samples using the same assay systems. NEQAS samples prepared by addition of either Idelvion or Alprolix to FIX deficient plasma were sent to 76 haemophilia centres in Europe. A total of 18 Idelvion and 22 Alprolix patient samples were assayed in a single centre. Two chromogenic and two one-stage assays were compared. RESULTS: The pattern of results obtained for NEQAS samples and patient samples was similar. In all cases, the NEQAS sample data point was within the scatter of patient sample data in plots of patient sample results showing one-stage assay results using Synthasil or Actin FS plotted against chromogenic assay results with Biophen or Rox chromogenic FIX kits. CONCLUSION: This indicates that the NEQAS samples containing Idelvion or Alprolix were commutable and therefore suitable for use in proficiency testing exercises.


Asunto(s)
Factor IX , Hemofilia B , Coagulación Sanguínea , Humanos , Fragmentos Fc de Inmunoglobulinas , Proteínas Recombinantes de Fusión , Albúmina Sérica , Reino Unido
11.
J Thromb Haemost ; 19(9): 2263-2267, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34227230

RESUMEN

BACKGROUND: Vaccine-induced immune thrombocytopenia and thrombosis (VITT) following the administration of the AstraZeneca (AZ) ChAdOx1 nCOV-19 vaccine has recently been reported. The associated clinical and laboratory features have included thrombosis at unusual sites, thrombocytopenia, and raised D-dimers with positivity for IgG anti-platelet factor 4 (PF4) antibodies. OBJECTIVES: A UK National External Quality Control Assessment Scheme external quality control exercise was carried out by distributing liquid and lyophilized samples from a subject with VITT, a pool of samples from subjects with classical heparin-induced thrombocytopenia (HIT), and a non-VITT/non-HIT case to 85 centers performing HIT testing. METHODS: Participating centers employed their locally validated testing methods for HIT assays. RESULTS: The lyophilized and liquid samples were found to be commutable for the ELISA assays used in the detection of anti-PF4 antibodies. The Aeskulisa, Stago, Hyphen, and LIFECODES anti-PF4 ELISA assays successfully detected the VITT antibody, whereas the Acustar HIT, Werfen LIA, and the Stago STIC assays did not. CONCLUSION: It is important that clinical and laboratory teams are aware of the limitations of some anti-PF4 assays when using them to aid diagnosis of VITT syndrome.


Asunto(s)
Púrpura Trombocitopénica Idiopática , Trombocitopenia , Trombosis , Vacunas , Vacunas contra la COVID-19 , ChAdOx1 nCoV-19 , Heparina/efectos adversos , Humanos , Factor Plaquetario 4 , Púrpura Trombocitopénica Idiopática/inducido químicamente , Púrpura Trombocitopénica Idiopática/diagnóstico , Trombocitopenia/inducido químicamente , Trombocitopenia/diagnóstico , Reino Unido
12.
Haemophilia ; 27(3): 490-499, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33650732

RESUMEN

INTRODUCTION: Inhibitor formation is the greatest challenge facing persons with haemophilia treated with factor concentrates. The gold standard testing methodologies are the Nijmegen-Bethesda assay (NBA) for FVIII and Bethesda assay (BA) for FIX inhibitors, which are affected by pre-analytical and inter-laboratory variability. AIMS: To evaluate inhibitor testing methodology and assess correlation between self-reported and actual methodology. METHODS: Methodology was evaluated using a survey distributed alongside a UK National External Quality Assessment Service Blood Coagulation external quality assurance (EQA) exercise for FVIII and FIX inhibitor testing. RESULTS: Seventy four survey and EQA exercise responses were received (response rate 63.2%), with 50 paired survey/EQA results. 47.1% (33/70) reported using the NBA and 42.9% (30/70) the BA for FVIII inhibitor testing. Review of FVIII inhibitor assay methodology demonstrated discrepancy (self-reported to actual) in 64.3% (BA reporting) and 27.6% (NBA reporting). Pre-analytical heat treatment was used by 32.4%, most commonly 56°C for 30 minutes. Assay cut-offs of 0.1-1.0 BU/mL were reported. EQA samples (acquired FVIII and congenital FIX) demonstrated titres and coefficients of variation (CV) of 3.1 BU/mL (0.7-15.4 BU/mL; CV = 43%) and 18.0 BU/mL (0-117 BU/mL; CV = 33%), respectively. No significant assay or laboratory factors were found to explain this variance, which could have resulted in change in management for 6 patients (5 misclassified high-titre FVIII inhibitors and 1 false negative for a FIX inhibitor). CONCLUSIONS: Heterogeneity was seen at each stage of assay methodology. No assay-related factors were found to explain variation in inhibitor titres. Further standardization is required to improve inhibitor quantification to guide patient care.


Asunto(s)
Factor VIII , Hemofilia A , Inhibidores de Factor de Coagulación Sanguínea , Pruebas de Coagulación Sanguínea , Hemofilia A/diagnóstico , Hemofilia A/tratamiento farmacológico , Humanos , Reino Unido
13.
Int J Lab Hematol ; 43(5): 1198-1206, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33605545

RESUMEN

INTRODUCTION: Haemolysis is considered one of the major contributors of nonconformities and sample rejection in coagulation testing. MATERIALS AND METHODS: Two lyophilized plasmas were distributed to 800 centres registered for prothrombin time (PT), activated partial thromboplastin time (APTT) and either Clauss fibrinogen or thrombin time (TT) in the UK NEQAS BC programme. The same pool of normal plasma was used to prepare both samples, to one of which red blood cell haemolysate was added to mimic haemolysis at 3 g/L haemoglobin concentration. Participants were asked to complete a questionnaire about their laboratory approach to dealing with haemolysed samples, including strategies used to deal with different levels of haemolysis. RESULTS: Results for tests performed did not show great differences between the two samples. It should be noted that artificially constructed haemolysed samples may not behave in the same way as patient samples (ie, may not be commutable). However, the possibility of carrying out a large multicentre study for detection of haemolysis was demonstrated. Inconsistency in practice was observed with 226/551 (41%) of centres indicated they reject haemolysed samples solely on visual checks, and 163 (30%) using initial visual checks with further sample rejection evaluation by analyser flags. Furthermore, 333 (72%) of centres indicated that the level of haemolysis affects sample rejection decisions, while 132 (28%) stated it did not. CONCLUSION: Variability of responses for dealing with haemolysed samples reflects a lack of clear consistency in the pre-analytical area of sample processing.


Asunto(s)
Pruebas de Coagulación Sanguínea/métodos , Coagulación Sanguínea , Fibrinógeno/análisis , Hemólisis , Hemostasis , Humanos , Reino Unido
14.
Haemophilia ; 26(6): 1087-1091, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33094895

RESUMEN

INTRODUCTION: Emicizumab (Hemlibra: Roche Switzerland) is a, humanized, bi-specific monoclonal modified immunoglobulin G4 (IgG4) which binds human FX, FIX and activated FIX (FIXa) to mimic activated FVIII activity. AIM: Evaluate the effects of emicizumab on the APTT, surrogate FVIII activity and FVIII inhibitor results. METHODS: Two samples were provided, one obtained from an emicizumab treated severe haemophilia A patient with FVIII inhibitors and one constructed by in vitro addition of emicizumab using plasma from a severe haemophilia A patient without FVIII inhibitors. An APTT screen, surrogate FVIII and FVIII inhibitor tests were performed on both samples by participating centres. RESULTS: APTT results were below the lower limit of normal range. Chromogenic FVIII assay results with the Hyphen/Biophen human component-based assay gave higher than expected coefficient of variation (CV) results, 38%-40%. The modified one-stage FVIII assay with emicizumab calibrators showed similar results regardless of the APTT reagent. Inhibitor assay median results for sample S18:23 = 1.43 BU (range 0.9-3.0 BU/ml, CV 38%). S18:24 was classified as below the lower limit of detection. CONCLUSION: APTT screens showed a consistent shortening. Unmodified one-stage Factor VIII assay results were remarkably high. APTT-based assays are unsuitable for measurement of coagulation factors or inhibitors in patients treated with emicizumab. Bovine origin chromogenic assays are insensitive to emicizumab and should be used to monitor FVIII levels/FVIII inhibitors in emicizumab treated patients. Product-specific calibrators should be implemented to reduce result variability.


Asunto(s)
Anticuerpos Biespecíficos/uso terapéutico , Anticuerpos Monoclonales Humanizados/uso terapéutico , Pruebas de Coagulación Sanguínea/métodos , Factor VIII/uso terapéutico , Tiempo de Tromboplastina Parcial/métodos , Animales , Anticuerpos Biespecíficos/farmacología , Anticuerpos Monoclonales Humanizados/farmacología , Ejercicio Físico , Factor VIII/farmacología , Humanos
15.
Sci Transl Med ; 12(553)2020 07 22.
Artículo en Inglés | MEDLINE | ID: mdl-32718993

RESUMEN

Arterial thrombosis causes heart attacks and most strokes and is the most common cause of death in the world. Platelets are the cells that form arterial thrombi, and antiplatelet drugs are the mainstay of heart attack and stroke prevention. Yet, current drugs have limited efficacy, preventing fewer than 25% of lethal cardiovascular events without clinically relevant effects on bleeding. The key limitation on the ability of all current drugs to impair thrombosis without causing bleeding is that they block global platelet activation, thereby indiscriminately preventing platelet function in hemostasis and thrombosis. Here, we identify an approach with the potential to overcome this limitation by preventing platelet function independently of canonical platelet activation and in a manner that appears specifically relevant in the setting of thrombosis. Genetic or pharmacological targeting of the class II phosphoinositide 3-kinase (PI3KC2α) dilates the internal membrane reserve of platelets but does not affect activation-dependent platelet function in standard tests. Despite this, inhibition of PI3KC2α is potently antithrombotic in human blood ex vivo and mice in vivo and does not affect hemostasis. Mechanistic studies reveal this antithrombotic effect to be the result of impaired platelet adhesion driven by pronounced hemodynamic shear stress gradients. These findings demonstrate an important role for PI3KC2α in regulating platelet structure and function via a membrane-dependent mechanism and suggest that drugs targeting the platelet internal membrane may be a suitable approach for antithrombotic therapies with an improved therapeutic window.


Asunto(s)
Plaquetas , Trombosis , Animales , Hemostasis , Ratones , Fosfatidilinositol 3-Quinasas , Activación Plaquetaria , Agregación Plaquetaria , Trombosis/tratamiento farmacológico
18.
J Thromb Haemost ; 18(8): 1874-1883, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32311825

RESUMEN

BACKGROUND: Patients with hemophilia B are increasingly treated with extended half-life (EHL) factor IX (FIX) concentrates. For the laboratory, introduction of these EHL concentrates presents a major challenge. To understand the variation in FIX activity levels, all available diagnostic assays need to be directly compared. METHODS: The ECAT, UKNEQAS, and RCPAQAP have collaboratively performed a global survey to evaluate the quality of FIX measurements using FIX deficient plasma samples spiked with recombinant FIX (rFIX), rFIXFP, rFIXFc, and N9-GP to levels at typical FIX trough (6 IU/dL) and peak levels (60 IU/dL). Participants were asked to use their routine protocols, using one-stage assays (OSA) or chromogenic assays (CA). RESULTS: In samples spiked with 6 IU/dL product, median (25%-75% range) FIX activity levels (OSA), were 8.0 IU/dL (7.0-9.2) for rFIX, 6.0 IU/dL (4.0-7.1) for rFIXFP, 6.6 IU/dL (5.5-8.0) for rFIXFc, and 4.9 IU/dL (3.5-8.4) for N9-GP. In samples spiked with 60 IU/dL, FIX activity levels measured (using OSA) was 63.0 IU/dL (59.9-67.0) for rFIX, 42.5 IU/dL (28.2-47.0) for rFIXFP, 50.0 IU/dL (45.0-55.0) for rFIXFc, and 34.0 IU/dL (24.8-67.5) for N9-GP. Considerable differences were observed between reagents for all samples. With CA, there was also quite some variation, but no differences between reagents. CONCLUSION: Large variation is observed in the measurement of FIX activity levels after administration of rFIX and EHL FIX products. For N9-GP, most silica-based assays show especially high levels. It is essential to standardize and improve reliability of measurements of these concentrates as diagnosis and treatment monitoring is based on these results.


Asunto(s)
Factor IX , Hemofilia B , Semivida , Hemofilia B/diagnóstico , Hemofilia B/tratamiento farmacológico , Humanos , Control de Calidad , Proteínas Recombinantes , Reproducibilidad de los Resultados
19.
Int J Lab Hematol ; 41(1): 39-45, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30184324

RESUMEN

External Quality Assessment (EQA) is an important part of laboratory quality assurance. Spiking of normal plasma is sometimes employed to mimic clinical samples. It is important that spiked material gives similar results to clinical samples (ie, is commutable) to ensure appropriate conclusions can be drawn from EQA exercises. We describe here data from UK National External Quality Assessment Scheme for Blood Coagulation (NEQAS BC) exercises where spiked samples were tested alongside samples from patients to explore commutability of artificial material. Normal plasma was spiked with unfractionated heparin (UFH), low molecular weight heparin (LMWH), Dabigatran or Rivaroxaban. Factor VIII (FVIII) deficient plasma was spiked with FVIII concentrate. Spiked samples and ex vivo patient material were sent to laboratories for testing. For LMWH, good agreement was seen between results for samples from patient plasma and plasma spiked with heparin. For UFH, APTT ratios differed between spiked and patient samples for the same drug concentration, with no correlation in ranking of reagents. Precision for patient and spiked material for Rivaroxaban and Dabigatran assays was comparable. However, the pattern of results for some Dabigatran assay kits differed between spiked and patient samples. For FVIII assays, results obtained with spiked and postinfusion samples gave comparable results. Spiked material is suitable for EQA if commutability is demonstrated. Our data show commutability for plasma spiked with Rivaroxaban, LWMH and some FVIII concentrates. For some tests, notably APTT for UFH, marked differences between patient and spiked samples indicate not all tests can be evaluated using artificial samples.


Asunto(s)
Técnicas de Laboratorio Clínico/normas , Garantía de la Calidad de Atención de Salud , Control de Calidad , Pruebas de Coagulación Sanguínea , Humanos , Ciencia del Laboratorio Clínico/normas
20.
Int J Lab Hematol ; 41(2): 176-183, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30556650

RESUMEN

INTRODUCTION: Variability in FVIII measurement is a recognized problem. There are limited data for samples containing recombinant Factor VIII Fc fusion protein (rFVIIIFc). Many studies use samples for which factor concentrate has been spiked into FVIII deficient plasma in vitro. This approach requires validation. AIM/METHODS: Four samples were distributed in a UK National External Quality Assessment Scheme for Blood Coagulation (NEQAS BC) survey. One contained Advate (full-length recombinant FVIII) (rFVIII) added to FVIII deficient plasma, one was from a severe haemophilia A patient after infusion of Advate, one was prepared by addition of rFVIIIFc (marketed as Elocta/Eloctate) to FVIII deficient plasma and the fourth was collected from a severe haemophilia A patient following rFVIIIFc (Eloctate) infusion. Fifty-three haemophilia centres (UK and Scandinavia) performed one-stage FVIII assays and 27 performed chromogenic FVIII assays. RESULTS/CONCLUSIONS: One-stage assays gave significantly lower results than chromogenic assays by 7% (P < 0.01) and 13%(P < 0.001) for post-Advate and Advate spiked samples, and by 22% (P < 0.001) and 23% (P < 0.001) for post-rFVIIIFc and rFVIIIFc spiked samples. The interlaboratory variation was similar for all samples, with CVs of 12%-16% (chromogenic) and 10%-13% (one stage). The data indicate that either product can be safely monitored by one-stage or chromogenic assay. Spiked samples behaved in a similar way to post-infusion samples for both products and could be substituted for post-infusion samples for use in proficiency testing exercises (ie, samples were commutable).


Asunto(s)
Coagulación Sanguínea , Factor VIII , Fragmentos Fc de Inmunoglobulinas , Proteínas Recombinantes de Fusión , Pruebas de Coagulación Sanguínea , Factor VIII/análisis , Factor VIII/farmacología , Humanos , Fragmentos Fc de Inmunoglobulinas/análisis , Fragmentos Fc de Inmunoglobulinas/farmacología , Proteínas Recombinantes de Fusión/análisis , Proteínas Recombinantes de Fusión/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...