Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
Phys Med Biol ; 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38925139

RESUMEN

OBJECTIVE: The partial-volume effect (PVE) is an important factor impairing tumour quantification in molecular imaging. The commonly used contour-volume-of-interest (contour-VOI) approach to correct for this effect employs phantom-based recovery coefficients. Applying oversize-VOIs could offer superior quantification accuracy in small lesions. The oversize-VOI approach uses a large oversize volume to determine the total tumour activity after applying a background correction. Aims of this study were to provide a procedure for the application of an oversize-VOI approach and to compare its performance to the contour-VOI approach in PET imaging. APPROACH: A sphere tumour model was simulated to determine the oversize diameter that contained 90%, 95%, and 98% of the total activity as a function of the tumour size. Experimental investigations involving phantom and clinical data were conducted on a digital PET/CT scanner. In the phantom investigation, 12 spherical tumour inserts (diameters ranging from 3.7 to 37.4 mm) containing18F-solution were used. The accuracy of the contour- and oversize-VOI approach was evaluated for different signal-to-background ratios (20 to 3). Clinically, both approaches were applied on PET/CT images acquired with18F-labelled prostate-specific membrane antigen in prostate cancer patients. MAIN RESULTS: From the tumour model, we deduced that an oversize-VOI of two PET spatial resolutions larger than the physical lesion diameter contains at least 98% of the total activity for lesions with diameters down to one PET spatial resolution, while minimizing the background contribution. Both approaches were robust against varying phantom and clinical imaging conditions. Performance of the oversize-VOI approach was favorable for lesions below 10 mm in diameter, whereas the contour-VOI approach was slightly more accurate for sizes above 10 mm. SIGNIFICANCE: The oversize-VOI approach facilitates image quantification of small tumours. It is simple and effective to correct for the PVE, and may be used in pre-therapeutic (small) tumour dosimetry.

2.
J Nucl Med ; 65(6): 931-937, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38637142

RESUMEN

Para-aminohippurate, also known as p-aminohippuric acid (PAH), is used clinically to measure effective renal plasma flow. Preclinically, it was shown to reduce 177Lu-DOTATOC uptake in the kidneys while improving bioavailability compared with amino acid (AA) coinfusion. We report the safety and efficacy of PAH coinfusion during peptide receptor radiotherapy in patients with neuroendocrine tumors. Methods: Twelve patients with metastatic or unresectable gastroenteropancreatic neuroendocrine tumors received 177Lu-DOTATOC in 33 treatment cycles. Either 8 g of PAH or a mixture of 25 g of arginine and 25 g of lysine were coinfused. Safety was assessed by monitoring laboratory data, including hematologic and renal data, as well as electrolytes obtained before and 24 h after treatment. For radiation dosimetry, whole-body scans were performed at 1, 24, and 48 h and a SPECT/CT scan was performed at 48 h, along with blood sampling at 5 min and 0.5, 2, 4, 24, and 48 h after administration. Absorbed dose estimations for the kidneys and bone marrow were performed according to the MIRD concept. Results: In 15 treatment cycles, PAH was coinfused. No changes in mean creatinine level, glomerular filtration rate, and serum electrolytes were observed before or 24 h after treatment when using PAH protection (P ≥ 0.20), whereas serum chloride and serum phosphate increased significantly under AA (both P < 0.01). Kidney-absorbed dose coefficients were 0.60 ± 0.14 Gy/GBq with PAH and 0.53 ± 0.16 Gy/GBq with AA. Based on extrapolated cumulative kidney-absorbed doses for 4 cycles, 1 patient with PAH protection and 1 patient with AA protection in our patient group would exceed the 23-Gy conservative threshold. The bone marrow-absorbed dose coefficient was 0.012 ± 0.004 Gy/GBq with PAH and 0.012 ± 0.003 Gy/GBq with AA. Conclusion: PAH is a promising alternative to AA for renal protection during peptide receptor radiotherapy. Further research is required to systematically investigate the safety profile and radiation dosimetry at varying PAH plasma concentrations.


Asunto(s)
Riñón , Tumores Neuroendocrinos , Octreótido , Humanos , Tumores Neuroendocrinos/radioterapia , Tumores Neuroendocrinos/metabolismo , Masculino , Femenino , Persona de Mediana Edad , Anciano , Octreótido/análogos & derivados , Octreótido/uso terapéutico , Octreótido/efectos adversos , Riñón/efectos de la radiación , Riñón/metabolismo , Receptores de Péptidos/metabolismo , Adulto , Protección Radiológica , Seguridad , Compuestos Organometálicos/uso terapéutico , Compuestos Organometálicos/efectos adversos
3.
EJNMMI Phys ; 11(1): 3, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38167953

RESUMEN

AIM: Positron emission tomography (PET) using 124I-mIBG has been established for imaging and pretherapeutic dosimetry. Here, we report the first systematic analysis of the biodistribution and radiation dosimetry of 124I-mIBG in patients with neural crest tumours and project the results to paediatric patient models. METHODS: Adult patients with neural crest tumours who underwent sequential 124I-mIBG PET were included in this retrospective single-center analysis. PET data were acquired 4, 24, 48, and/or 120 h after administration of a mean of 43 MBq 124I-mIBG. Whole-body counting and blood sampling were performed at 2, 4, 24, 48 and 120 h after administration. Absorbed organ dose and effective dose coefficients were estimated in OLINDA/EXM 2.2 according to the MIRD formalism. Extrapolation to paediatric models was performed based on mass-fraction scaling of the organ-specific residence times. Biodistribution data for adults were also projected to 123I-mIBG and 131I-mIBG. RESULTS: Twenty-one patients (11 females, 10 males) were evaluated. For adults, the organs exposed to the highest dose per unit administered activity were urinary bladder (1.54 ± 0.40 mGy/MBq), salivary glands (0.77 ± 0.28 mGy/MBq) and liver (0.65 ± 0.22 mGy/MBq). Mean effective dose coefficient for adults was 0.25 ± 0.04 mSv/MBq (male: 0.24 ± 0.03 mSv/MBq, female: 0.26 ± 0.06 mSv/MBq), and increased gradually to 0.29, 0.44, 0.69, 1.21, and 2.94 mSv/MBq for the 15-, 10-, 5-, 1-years-old, and newborn paediatric reference patients. Projected mean effective dose coefficients for 123I-mIBG and 131I-mIBG for adults were 0.014 ± 0.002 mSv/MBq and 0.18 ± 0.04 mSv/MBq, respectively. CONCLUSION: PET-based derived radiation dosimetry data for 124I-mIBG from this study agreed well with historical projected data from ICRP 53. The effective dose coefficients presented here may aid in guidance for establishing weight-based activity administration protocols.

4.
J Nucl Med ; 65(1): 71-78, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38050121

RESUMEN

In the VISION trial, [177Lu]Lu-PSMA-617 (177Lu-PSMA-617) plus protocol-permitted standard of care significantly improved overall survival and radiographic progression-free survival compared with standard of care alone in patients with prostate-specific membrane antigen-positive metastatic castration-resistant prostate cancer. This VISION dosimetry substudy quantified absorbed doses of 177Lu-PSMA-617 in the kidneys and other organs. Methods: Participants were a separate cohort of 30 nonrandomized patients receiving standard of care plus 177Lu-PSMA-617 at 7.4 GBq per cycle for up to 6 cycles. Blood samples, whole-body conjugate planar image scintigraphy, and abdominal SPECT/CT images were collected. SPECT/CT images were collected at 2, 24, 48, and 168 h after administration in cycle 1 and at a single time point 48 h after administration in cycles 2-6. Outcomes were absorbed dose per unit activity per cycle and cumulative absorbed dose over all cycles. Cumulative absorbed doses were predicted by extrapolation from cycle 1, and calculation of observed values was based on measurements of cycle 1 and cycles 2-6. Safety was also assessed. Results: Mean (±SD) absorbed doses per cycle in the kidneys were 0.43 ± 0.16 Gy/GBq in cycle 1 and 0.44 ± 0.21 Gy/GBq in cycles 2-6. The observed and predicted 6-cycle cumulative absorbed doses in the kidneys were 15 ± 6 and 19 ± 7 Gy, respectively. Observed and predicted cumulative absorbed doses were similar in other at-risk organs. Safety findings were consistent with those in the VISION study; no patients experienced renal treatment-emergent adverse events of a grade higher than 3. Conclusion: The renal cumulative absorbed 177Lu-PSMA-617 dose was below the established limit. 177Lu-PSMA-617 had a good overall safety profile, and low renal radiotoxicity was not a safety concern. Cumulative absorbed doses in at-risk organs over multiple cycles can be predicted by extrapolation from cycle 1 data in patients with metastatic castration-resistant prostate cancer receiving 177Lu-PSMA-617.


Asunto(s)
Neoplasias de la Próstata Resistentes a la Castración , Masculino , Humanos , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Neoplasias de la Próstata Resistentes a la Castración/patología , Radiofármacos/efectos adversos , Dipéptidos/efectos adversos , Antígeno Prostático Específico , Compuestos Heterocíclicos con 1 Anillo/efectos adversos , Riñón , Lutecio/efectos adversos
5.
Phys Med ; 114: 103149, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37778973

RESUMEN

PURPOSE: The aim of this study was to investigate conditions for reliable quantification of sub-centimeter lesions with low18F,68Ga, and124I uptake using a silicon photomultiplier-based PET/CT system. METHODS: A small tumor phantom was investigated under challenging but clinically realistic conditions resembling prostate and thyroid cancer lymph node metastases (6 spheres with 3.7-9.7 mm in diameter, 9 different activity concentrations ranging from about 0.25-25 kBq/mL, and a signal-to-background ratio of 20). Radionuclides with different positron branching ratios and prompt gamma coincidence contributions were investigated. Maximum-, contour-, and oversize-based partial volume effect (PVE) correction approaches were applied. Detection and quantification performance were estimated, considering a ±30 % deviation between imaged-derived and true activity concentrations as acceptable. A standard and a prolonged acquisition time and two image reconstruction algorithms (time-of-flight with/without point spread function modelling) were analyzed. Clinical data were evaluated to assess agreement of PVE-correction approaches indicating lesion quantification validity. RESULTS: The smallest 3.7-mm sphere was not visible. If the lesions were clearly observed, quantification was, except for a few cases, acceptable using contour- or oversized-based PVE-corrections. Quantification accuracy did not substantially differ between 18F, 68Ga, and 124I. No systematic differences between the analyzed reconstruction algorithms or shorter and larger acquisition times were observed. In the clinical evaluation of 20 lesions, an excellent statistical agreement between oversize- and contour-based PVE-corrections was observed. CONCLUSIONS: At the lower end of size (<10 mm) and activity concentration ranges of lymph-node metastases, quantification with reasonable accuracy is possible for 18F, 68Ga, and 124I, possibly allowing pre-therapeutic lesion dosimetry and individualized radionuclide therapy planning.


Asunto(s)
Radioisótopos de Galio , Tomografía Computarizada por Tomografía de Emisión de Positrones , Masculino , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radioisótopos de Yodo/uso terapéutico , Radiometría , Tomografía de Emisión de Positrones
6.
J Nucl Med ; 64(6): 885-891, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36732054

RESUMEN

We aim to evaluate the efficacy and safety of 124I-metaiodobenzylguanidine (MIBG) dosimetry-guided high-activity 131I-MIBG therapy of advanced pheochromocytoma or neuroblastoma. Methods: Fourteen patients with advanced pheochromocytoma or neuroblastoma, age 9-69 y, underwent 124I-MIBG PET scans and whole-body retention measurements to assess the whole-body dose as a surrogate of bone marrow toxicity and tumor (absorbed) dose per unit of administered activity. Dosimetry results together with individual patient characteristics were combined to guide a single therapeutic activity to achieve a high tumor dose without exceeding toxicity threshold. Toxicity was assessed for hematologic, hepatic, and renal function. Response was evaluated by RECIST, International Society of Pediatric Oncology Europe Neuroblastoma-like score, change in PET uptake, and quantitative PET parameters (SUVmax, SUVpeak, metabolic tumor volume, total lesion glycolysis), as well as visual decrease in number or in visual intensity of lesions on baseline to follow-up 124I-MIBG PET/CT. Results: The average therapeutic activity was 14 GBq. Eleven of 14 patients (79%) received each more than 10 GBq. One male patient was treated with a single activity of 50 GBq. Three patients were treated with lower activities between 3.5 and 7.0 GBq. Median overall survival was 85 mo (95% CI), and median progression-free survival was 25 mo (95% CI). Four (29%) and 5 (36%) patients demonstrated response (complete response or partial response) by RECIST and functional imaging, respectively. One patient exceeded whole-body dose of 2 Gy and demonstrated grade 3 hematologic toxicity, which resolved spontaneously within 12 mo after the therapy without the need for further treatment. Three patients (21%) demonstrated transient grade 1 renal toxicity. Conclusion: 124I-MIBG dosimetry-guided high-activity 131I-MIBG therapy in patients with advanced pheochromocytoma or neuroblastoma resulted in durable responses with a low rate of manageable adverse events. Efficacy of 124I-MIBG-guided activity escalation should further be assessed in a prospective setting.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Neuroblastoma , Feocromocitoma , Niño , Humanos , Masculino , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , 3-Yodobencilguanidina/efectos adversos , Feocromocitoma/diagnóstico por imagen , Feocromocitoma/radioterapia , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Prospectivos , Neuroblastoma/diagnóstico por imagen , Neuroblastoma/radioterapia , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Neoplasias de las Glándulas Suprarrenales/radioterapia
7.
Q J Nucl Med Mol Imaging ; 67(1): 57-68, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34309334

RESUMEN

BACKGROUND: The aim of this phantom study was to optimize the [68Ga]Ga-PSMA PET/CT examination in terms of scan time duration and image reconstruction parameters, in combination with PSF and TOF modelling, in a digital Biograph Vision PET/CT scanner. METHODS: Three types of phantoms were used: 1) soft-tissue tumor phantom consisting of six spheres mounted in a torso phantom; 2) bone-lung tumor phantom; 3) resolution phantom. Phantom inserts were filled with activity concentrations (ACs) that were derived from clinical data. Phantom data were acquired in list-mode at one bed position. Images with emission data ranging from 30 to 210 s in 30-s increments were reconstructed from a reference image acquired with 3.5-min emission. Iterative image reconstruction (OSEM), point-spread-function (PSF) and time-of-flight (TOF) options were applied using different iterations, Gaussian filters, and voxel sizes. The criteria for image quality was lesion detectability and lesion quantification, evaluated as contrast-to-noise ratio (CNR) and maximum AC (peak AC), respectively. A threshold value of CNR above 6 and percentage maximum AC (peak AC) deviation range of ±20% of the reference image were considered acceptable. The proposed single-bed scan time reduction was projected to a whole-body examination (patient validation scan) using the continuous-bed-motion mode. RESULTS: Sphere and background ACs of 20 kBq/mL and 1 kBq/mL were selected, respectively. The optimized single-bed scan time was approximately 60 s using OSEM-TOF or OSEM-TOF+PSF (four iterations, 4.0-mm Gaussian filter and almost isotropic voxel size of 3.0-mm side length), resulting in a PET spatial resolution of 6.3 mm for OSEM-TOF and 5.5 mm for OSEM-TOF+PSF. In the patient validation, the maximum percentage difference in lesion quantification between standard and optimized protocol (whole-body scan time of 15 vs. 5 min) was below 19%. CONCLUSIONS: A reduction of single-bed and whole-body scan time for [68Ga]Ga-PSMA PET/CT compared to current recommended clinical acquisition protocols is postulated. Clinical studies are warranted to validate the applicability of this protocol.


Asunto(s)
Radioisótopos de Galio , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X , Factores de Tiempo , Fantasmas de Imagen
8.
J Nucl Cardiol ; 30(1): 101-111, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35562639

RESUMEN

INTRODUCTION: Transthyretin (ATTR) amyloidosis is responsible for the majority of cardiac amyloidosis (CA) cases and can be reliably diagnosed with bone scintigraphy and the visual Perugini score. We aimed to implement a quantification method of cardiac amyloid deposits in patients with suspected cardiac amyloidosis and to compare performance to visual scoring. METHODS AND MATERIALS: 136 patients received 99mTc-DPD-bone scintigraphy including SPECT/CT of the thorax in case of suspicion of cardiac amyloidosis. Imaging phantom studies were performed to determine the scaling factor for standardized uptake value (SUV) quantification from SPECT/CT. Myocardial tracer uptake was quantified in a whole heart volume of interest. RESULTS: Forty-five patients were diagnosed with CA. A strong relationship between cardiac SUVmax and Perugini score was found (Spearman r 0.75, p < 0.0001). Additionally, tracer uptake in bone decreased with increasing cardiac SUVmax and Perugini score (p < 0.0001). ROC analysis revealed good performance of the SUVmax for the detection of ATTR-CA with AUC of 0.96 ± 0.02 (p < 0.0001) with sensitivity 98.7% and specificity 87.2%. CONCLUSION: We demonstrate an accessible and accurate quantitative SPECT approach in CA. Quantitative assessment of the cardiac tracer uptake may improve diagnostic accuracy and risk classification. This method may enable monitoring and assessment of therapy response in patients with ATTR amyloidosis.


Asunto(s)
Amiloidosis , Cardiomiopatías , Humanos , Corazón , Prealbúmina , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X
9.
J Nucl Med ; 64(2): 329-336, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35981898

RESUMEN

Therapy with 90Y-labeled fibroblast activation protein inhibitors (90Y-FAPIs) was recently introduced as a novel treatment concept for patients with solid tumors. Lesion and organ-at-risk dosimetry is part of assessing treatment efficacy and safety and requires reliable quantification of tissue uptake. As 90Y quantification is limited by the low internal positron-electron pair conversion rate, the increased effective sensitivity of digital silicon photomultiplier-based PET/CT systems might increase quantification accuracy and, consequently, allow for dosimetry in 90Y-FAPI therapy. The aim of this study was to explore the conditions for reliable lesion image quantification in 90Y-FAPI radionuclide therapy using a digital PET/CT system. Methods: Two tumor phantoms were filled with 90Y solution using different sphere activity concentrations and a constant signal-to-background ratio of 40. The minimum detectable activity concentration was determined, and its dependence on acquisition time (15 vs. 30 min per bed position) and smoothing levels (all-pass vs. 5-mm gaussian filter) was investigated. Quantification accuracy was evaluated at various activity concentrations to estimate the minimum quantifiable activity concentration using contour-based and oversized volume-of-interest-based quantification approaches. A ±20% deviation range between image-derived and true activity concentrations was regarded as acceptable. Tumor dosimetry for 3 patients treated with 90Y-FAPI is presented to project the phantom results to clinical scenarios. Results: For a lesion size of 40 mm and a clinical acquisition time of 15 min, both minimum detectable and minimum quantifiable activity concentrations were 0.12 MBq/mL. For lesion sizes of greater than or equal to 30 mm, accurate quantification was feasible for detectable lesions. Only for the smallest 10-mm sphere, the minimum detectable and minimum quantifiable activity concentrations differ substantially (0.43 vs. 1.97 MBq/mL). No notable differences between the 2 quantification approaches were observed. For the investigated tumors, absorbed dose estimates with reliable accuracy were achievable. Conclusion: For lesion sizes and activity concentrations that are expected to be observed in patients treated with 90Y-FAPI, quantification with reasonable accuracy is possible. Further dosimetry studies are needed to thoroughly investigate the efficacy and safety of 90Y-FAPI therapy.


Asunto(s)
Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Radioisótopos de Itrio/uso terapéutico , Tomografía de Emisión de Positrones/métodos , Neoplasias/diagnóstico por imagen , Neoplasias/radioterapia , Neoplasias/tratamiento farmacológico , Fibroblastos , Radioisótopos de Galio
10.
EJNMMI Phys ; 9(1): 56, 2022 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-35984531

RESUMEN

AIM: To evaluate the effect of combining positron range correction (PRC) with point-spread-function (PSF) correction and to compare different methods of implementation into iterative image reconstruction for 124I-PET imaging. MATERIALS AND METHODS: Uniform PR blurring kernels of 124I were generated using the GATE (GEANT4) framework in various material environments (lung, water, and bone) and matched to a 3D matrix. The kernels size was set to 11 × 11 × 11 based on the maximum PR in water and the voxel size of the PET system. PET image reconstruction was performed using the standard OSEM algorithm, OSEM with PRC implemented before the forward projection (OSEM+PRC simplified) and OSEM with PRC implemented in both forward- and back-projection steps (full implementation) (OSEM+PRC). Reconstructions were repeated with resolution recovery, point-spread function (PSF) included. The methods and kernel variation were validated using different phantoms filled with 124I acquired on a Siemens mCT PET/CT system. The data was evaluated for contrast recovery and image noise. RESULTS: Contrast recovery improved by 2-10% and 4-37% with OSEM+PRC simplified and OSEM+PRC, respectively, depending on the sphere size of the NEMA IQ phantom. Including PSF in the reconstructions further improved contrast by 4-19% and 3-16% with the PSF+PRC simplified and PSF+PRC, respectively. The benefit of PRC was more pronounced within low-density material. OSEM-PRC and OSEM-PSF as well as OSEM-PSF+PRC in its full- and simplified implementation showed comparable noise and convergence. OSEM-PRC simplified showed comparably faster convergence but at the cost of increased image noise. CONCLUSIONS: The combination of the PSF and PRC leads to increased contrast recovery with reduced image noise compared to stand-alone PSF or PRC reconstruction. For OSEM-PRC reconstructions, a full implementation in the reconstruction is necessary to handle image noise. For the combination of PRC with PSF, a simplified PRC implementation can be used to reduce reconstruction times.

11.
BMC Cancer ; 22(1): 899, 2022 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-35978274

RESUMEN

BACKGROUND: New-generation silicon-photomultiplier (SiPM)-based PET/CT systems exhibit an improved lesion detectability and image quality due to a higher detector sensitivity. Consequently, the acquisition time can be reduced while maintaining diagnostic quality. The aim of this study was to determine the lowest 18F-FDG PET acquisition time without loss of diagnostic information and to optimise image reconstruction parameters (image reconstruction algorithm, number of iterations, voxel size, Gaussian filter) by phantom imaging. Moreover, patient data are evaluated to confirm the phantom results. METHODS: Three phantoms were used: a soft-tissue tumour phantom, a bone-lung tumour phantom, and a resolution phantom. Phantom conditions (lesion sizes from 6.5 mm to 28.8 mm in diameter, lesion activity concentration of 15 kBq/mL, and signal-to-background ratio of 5:1) were derived from patient data. PET data were acquired on an SiPM-based Biograph Vision PET/CT system for 10 min in list-mode format and resampled into time frames from 30 to 300 s in 30-s increments to simulate different acquisition times. Different image reconstructions with varying iterations, voxel sizes, and Gaussian filters were probed. Contrast-to-noise-ratio (CNR), maximum, and peak signal were evaluated using the 10-min acquisition time image as reference. A threshold CNR value ≥ 5 and a maximum (peak) deviation of ± 20% were considered acceptable. 20 patient data sets were evaluated regarding lesion quantification as well as agreement and correlation between reduced and full acquisition time standard uptake values (assessed by Pearson correlation coefficient, intraclass correlation coefficient, Bland-Altman analyses, and Krippendorff's alpha). RESULTS: An acquisition time of 60 s per bed position yielded acceptable detectability and quantification results for clinically relevant phantom lesions ≥ 9.7 mm in diameter using OSEM-TOF or OSEM-TOF+PSF image reconstruction, a 4-mm Gaussian filter, and a 1.65 × 1.65 x 2.00-mm3 or 3.30 × 3.30 x 3.00-mm3 voxel size. Correlation and agreement of patient lesion quantification between full and reduced acquisition times were excellent. CONCLUSION: A threefold reduction in acquisition time is possible. Patients might benefit from more comfortable examinations or reduced radiation exposure, if instead of the acquisition time the applied activity is reduced.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Tomografía de Emisión de Positrones
12.
Clin Cancer Res ; 28(19): 4194-4202, 2022 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-35594174

RESUMEN

PURPOSE: Restoration of iodine incorporation (redifferentiation) by MAPK inhibition was achieved in previously radioiodine-refractory, unresectable thyroid carcinoma (RR-TC). However, results were unsatisfactory in BRAFV600E-mutant (BRAF-MUT) RR-TC. Here we assess safety and efficacy of redifferentiation therapy through genotype-guided MAPK-modulation in patients with BRAF-MUT or wildtype (BRAF-WT) RR-TC. PATIENTS AND METHODS: In this prospective single-center, two-arm phase II study, patients received trametinib (BRAF-WT) or trametinib + dabrafenib (BRAF-MUT) for 21 ± 3 days. Redifferentiation was assessed by 123I-scintigraphy. In case of restored radioiodine uptake, 124I-guided 131I therapy was performed. Primary endpoint was the redifferentiation rate. Secondary endpoints were treatment response (thyroglobulin, RECIST 1.1) and safety. Parameters predicting successful redifferentiation were assessed using a receiver operating characteristic analysis and Youden J statistic. RESULTS: Redifferentiation was achieved in 7 of 20 (35%) patients, 2 of 6 (33%) in the BRAF-MUT and 5 of 14 (36%) in the BRAF-WT arm. Patients received a mean (range) activity of 300.0 (273.0-421.6) mCi for 131I therapy. Any thyroglobulin decline was seen in 57% (4/7) of the patients, RECIST 1.1 stable/partial response/progressive disease in 71% (5/7)/14% (1/7)/14% (1/7). Peak standardized uptake value (SUVpeak) < 10 on 2[18F]fluoro-2-deoxy-D-glucose (FDG)-PET was associated with successful redifferentiation (P = 0.01). Transient pyrexia (grade 3) and rash (grade 4) were noted in one patient each. CONCLUSIONS: Genotype-guided MAPK inhibition was safe and resulted in successful redifferentiation in about one third of patients in each arm. Subsequent 131I therapy led to a thyroglobulin (Tg) decline in more than half of the treated patients. Low tumor glycolytic rate as assessed by FDG-PET is predictive of redifferentiation success. See related commentary by Cabanillas et al., p. 4164.


Asunto(s)
Radioisótopos de Yodo , Neoplasias de la Tiroides , Fluorodesoxiglucosa F18 , Humanos , Radioisótopos de Yodo/uso terapéutico , Estudios Prospectivos , Inhibidores de Proteínas Quinasas/efectos adversos , Proteínas Proto-Oncogénicas B-raf/antagonistas & inhibidores , Tiroglobulina/genética , Neoplasias de la Tiroides/tratamiento farmacológico , Neoplasias de la Tiroides/genética , Neoplasias de la Tiroides/radioterapia
13.
Eur J Nucl Med Mol Imaging ; 49(10): 3373-3386, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35412053

RESUMEN

PURPOSE: The determination of the glomerular filtration rate (GFR) is decisive for a variety of clinical issues, for example, to monitor the renal function in radionuclide therapy patients. Renal scintigraphy using glomerularly filtered tracers allows combined acquisition of renograms and GFR estimation but requires repeated blood sampling for several hours. In contrast, dynamic PET imaging using the glomerularly filtered tracer [68Ga]Ga-DOTA bears the potential to non-invasively estimate the GFR by compartmental kinetic modelling. Here, we report the, to our knowledge, first comparison of human renal dynamic [68Ga]Ga-DOTA PET imaging in comparison to renal scintigraphy and compare PET-derived to serum creatinine-derived GFR measurements. METHODS: Dynamic [68Ga]Ga-DOTA PET data were acquired for 30 min immediately after tracer injection in 12 patients. PET and renal scintigraphy images were visually interpreted in a consensus read by three nuclear medicine physicians. The functional renal cortex was segmented to obtain time-activity curves. The arterial input function was estimated from the PET signal in the abdominal aorta. Single-compartmental tracer kinetic modelling was performed to calculate the GFR using complete 30-min (GFRPET-30) and reduced 15-min PET data sets (GFRPET-15) to evaluate whether a shorter acquisition time is sufficient for an accurate GFR estimation. A modified approach excluding minutes 2 to 10 was applied to reduce urinary spill-over effects. Serum creatinine-derived GFRCKD (CKD-EPI-formula) was used as reference standard. RESULTS: PET image interpretation revealed the same findings as conventional scintigraphy (2/12 patients with both- and 1/12 patients with right-sided urinary obstruction). Model fit functions were substantially improved for the modified approach to exclude spill-over. Depending on the modelling approach, GFRCKD and both GFRPET-30 and GFRPET-15 were well correlated with interclass correlation coefficients (ICCs) from 0.74 to 0.80 and Pearson's correlation coefficients (PCCs) from 0.74 to 0.81. For a subgroup of patients with undisturbed urinary efflux (n = 9), correlations were good to excellent (ICCs from 0.82 to 0.95 and PCCs from 0.83 to 0.95). Overall, GFRPET-30 and GFRPET-15 were excellently correlated (ICCs from 0.96 to 0.99 and PCCs from 0.96 to 0.99). CONCLUSION: Renal [68Ga]Ga-DOTA PET can be a suitable alternative to conventional scintigraphy. Visual assessment of PET images and conventional renograms revealed comparable results. GFR values derived by non-invasive single-compartmental-modelling of PET data show a good correlation to serum creatinine-derived GFR values. In patients with undisturbed urinary efflux, the correlation was excellent. Dynamic PET data acquisition for 15 min is sufficient for visual evaluation and GFR derivation.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Insuficiencia Renal Crónica , Creatinina , Radioisótopos de Galio , Tasa de Filtración Glomerular , Compuestos Heterocíclicos con 1 Anillo , Humanos , Riñón/diagnóstico por imagen , Riñón/fisiología , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos
14.
Front Physiol ; 13: 818463, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35350691

RESUMEN

Aim: To develop and evaluate a new approach for spatially variant and tissue-dependent positron range (PR) correction (PRC) during the iterative PET image reconstruction. Materials and Methods: The PR distributions of three radionuclides (18F, 68Ga, and 124I) were simulated using the GATE (GEANT4) framework in different material compositions (lung, water, and bone). For every radionuclide, the uniform PR kernel was created by mapping the simulated 3D PR point cloud to a 3D matrix with its size defined by the maximum PR in lung (18F) or water (68Ga and 124I) and the PET voxel size. The spatially variant kernels were composed from the uniform PR kernels by analyzing the material composition of the surrounding medium for each voxel before implementation as tissue-dependent, point-spread functions into the iterative image reconstruction. The proposed PRC method was evaluated using the NEMA image quality phantom (18F, 68Ga, and 124I); two unique PR phantoms were scanned and evaluated following OSEM reconstruction with and without PRC using different metrics, such as contrast recovery, contrast-to-noise ratio, image noise and the resolution evaluated in terms of full width at half maximum (FWHM). Results: The effect of PRC on 18F-imaging was negligible. In contrast, PRC improved image contrast for the 10-mm sphere of the NEMA image quality phantom filled with 68Ga and 124I by 33 and 24%, respectively. While the effect of PRC was less noticeable for the larger spheres, contrast recovery still improved by 5%. The spatial resolution was improved by 26% for 124I (FWHM of 4.9 vs. 3.7 mm). Conclusion: For high energy positron-emitting radionuclides, the proposed PRC method helped recover image contrast with reduced noise levels and with improved spatial resolution. As such, the PRC approach proposed here can help improve the quality of PET data in clinical practice and research.

15.
Eur J Nucl Med Mol Imaging ; 49(4): 1101-1112, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34623453

RESUMEN

INTRODUCTION: Patient eligibility for [177Lu]Lu-PSMA therapy remains a challenge, with only 40-60% response rate when patient selection is done based on the lesion uptake (SUV) on [68Ga]Ga-PSMA-PET/CT. Prediction of absorbed dose based on this pre-treatment scan could improve patient selection and help to individualize treatment by maximizing the absorbed dose to target lesions while adhering to the threshold doses for the organs at risk (kidneys, salivary glands, and liver). METHODS: Ten patients with low-volume hormone-sensitive prostate cancer received a pre-therapeutic [68Ga]Ga-PSMA-11 PET/CT, followed by 3 GBq [177Lu]Lu-PSMA-617 therapy. Intra-therapeutically, SPECT/CT was acquired at 1, 24, 48, 72, and 168 h. Absorbed dose in organs and lesions (n = 22) was determined according to the MIRD scheme. Absorbed dose prediction based on [68Ga]Ga-PSMA-PET/CT was performed using tracer uptake at 1 h post-injection and the mean tissue effective half-life on SPECT. Predicted PET/actual SPECT absorbed dose ratios were determined for each target volume. RESULTS: PET/SPECT absorbed dose ratio was 1.01 ± 0.21, 1.10 ± 0.15, 1.20 ± 0.34, and 1.11 ± 0.29 for kidneys (using a 2.2 scaling factor), liver, submandibular, and parotid glands, respectively. While a large inter-patient variation in lesion kinetics was observed, PET/SPECT absorbed dose ratio was 1.3 ± 0.7 (range: 0.4-2.7, correlation coefficient r = 0.69, p < 0.01). CONCLUSION: A single time point [68Ga]Ga-PSMA-PET scan can be used to predict the absorbed dose of [177Lu]Lu-PSMA therapy to organs, and (to a limited extent) to lesions. This strategy facilitates in treatment management and could increase the personalization of [177Lu]Lu-PSMA therapy.


Asunto(s)
Radioisótopos de Galio , Neoplasias de la Próstata Resistentes a la Castración , Dipéptidos , Compuestos Heterocíclicos con 1 Anillo , Humanos , Lutecio , Masculino , Órganos en Riesgo/patología , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones , Antígeno Prostático Específico , Neoplasias de la Próstata Resistentes a la Castración/patología , Radiofármacos/uso terapéutico
16.
J Nucl Med ; 63(6): 869-874, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34556526

RESUMEN

123/131I-metaiodobenzylguanidine (MIBG) scintigraphy has shown a high specificity for imaging pheochromocytoma and paraganglioma, but with low sensitivity because of low spatial resolution. 124I-MIBG PET may be able to overcome this limitation and improve the staging of patients with (suspected) pheochromocytoma. Methods: We analyzed the sensitivity, specificity, and positive and negative predictive values of 124I-MIBG PET in 43 consecutive patients with suspected (recurrence of) pheochromocytoma using histopathologic (n = 25) and clinical validation (n = 18) as the standard of truth. Furthermore, we compared the detection rate of 124I-MIBG PET versus contrast-enhanced (CE) CT on a per-patient and per-lesion basis in 13 additional patients with known metastatic malignant pheochromocytoma. Results:124I-MIBG PET/CT was positive in 19 (44%) of 43 patients with suspected pheochromocytoma. The presence of pheochromocytoma was confirmed in 22 (51%) of 43. 124I-MIBG PET/CT sensitivity, specificity, and positive and negative predictive values were 86%, 100%, 100%, and 88%, respectively. 124I-MIBG PET was positive in 11 (85%) of 13 patients with malignant pheochromocytoma. Combined 124I-MIBG PET and CE CT detected 173 lesions, of which 166 (96%) and 118 (68%) were visible on 124I-MIBG PET and CE CT, respectively. Conclusion:124I-MIBG PET detects pheochromocytoma with high accuracy at initial staging and a high detection rate at restaging. Future assessment of 124I-MIBG PET for treatment guidance, including personalized 131I-MIBG therapy, is warranted.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Feocromocitoma , 3-Yodobencilguanidina , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Humanos , Radioisótopos de Yodo , Feocromocitoma/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones
17.
Eur J Nucl Med Mol Imaging ; 49(2): 460-469, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34218300

RESUMEN

INTRODUCTION: While [177Lu]Lu-PSMA radioligand therapy is currently only applied in end-stage metastatic castrate-resistant prostate cancer (mCRPC) patients, also low-volume hormone-sensitive metastatic prostate cancer (mHSPC) patients can benefit from it. However, there are toxicity concerns related to the sink effect in low-volume disease. This prospective study aims to determine the kinetics of [177Lu]Lu-PSMA in mHSPC patients, analyzing the doses to organs at risk (salivary glands, kidneys, liver, and bone marrow) and tumor lesions < 1 cm diameter. METHODS: Ten mHSPC patients underwent two cycles of [177Lu]Lu-PSMA therapy. Three-bed position SPECT/CT was performed at 5 time points after each therapy. Organ dosimetry and lesion dosimetry were performed using commercial software and a manual approach, respectively. Correlation between absorbed index lesion dose and treatment response (PSA drop of > 50% at the end of the study) was calculated and given as Spearman's r and p-values. RESULTS: Kinetics of [177Lu]Lu-PSMA in mHSPC patients are comparable to those in mCRPC patients. Lesion absorbed dose was high (3.25 ± 3.19 Gy/GBq) compared to organ absorbed dose (salivary glands: 0.39 ± 0.17 Gy/GBq, kidneys: 0.49 ± 0.11 Gy/GBq, liver: 0.09 ± 0.01 Gy/GBq, bone marrow: 0.017 ± 0.008 Gy/GBq). A statistically significant correlation was found between treatment response and absorbed index lesion dose (p = 0.047). CONCLUSIONS: We successfully performed small lesion dosimetry and showed that the tumor sink effect in mHSPC patients is of less concern than was expected. Tumor-to-organ ratio of absorbed dose was high and tumor uptake correlates with PSA response. Additional treatment cycles are legitimate in terms of organ toxicity and could lead to better tumor response.


Asunto(s)
Lutecio , Antígeno Prostático Específico , Neoplasias de la Próstata , Radiofármacos , Hormonas/metabolismo , Humanos , Lutecio/efectos adversos , Lutecio/farmacocinética , Lutecio/uso terapéutico , Masculino , Órganos en Riesgo/diagnóstico por imagen , Órganos en Riesgo/efectos de la radiación , Estudios Prospectivos , Antígeno Prostático Específico/efectos adversos , Antígeno Prostático Específico/sangre , Antígeno Prostático Específico/farmacocinética , Antígeno Prostático Específico/uso terapéutico , Neoplasias de la Próstata/sangre , Neoplasias de la Próstata/metabolismo , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/secundario , Dosis de Radiación , Radiofármacos/efectos adversos , Radiofármacos/farmacocinética , Radiofármacos/uso terapéutico , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Resultado del Tratamiento
18.
Sci Rep ; 11(1): 17477, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34471170

RESUMEN

The radioiodine isotope pair 124I/131I is used in a theranostic approach for patient-specific treatment of differentiated thyroid cancer. Lesion detectability is notably higher for 124I PET (positron emission tomography) than for 131I gamma camera imaging but can be limited for small and low uptake lesions. The recently introduced silicon-photomultiplier-based (SiPM-based) PET/CT (computed tomography) systems outperform previous-generation systems in detector sensitivity, coincidence time resolution, and spatial resolution. Hence, SiPM-based PET/CT shows an improved detectability, particularly for small lesions. In this study, we compare the size-dependant minimum detectable 124I activity (MDA) between the SiPM-based Biograph Vision and the previous-generation Biograph mCT PET/CT systems and we attempt to predict the response to 131I radioiodine therapy of lesions additionally identified on the SiPM-based system. A tumour phantom mimicking challenging conditions (derived from published patient data) was used; i.e., 6 small spheres (diameter of 3.7-9.7 mm), 9 low activity concentrations (0.25-25 kBq/mL), and a very low signal-to-background ratio (20:1). List-mode emission data (single-bed position) were divided into frames of 4, 8, 16, and 30 min. Images were reconstructed with ordinary Poisson ordered-subsets expectation maximization (OSEM), additional time-of-flight (OSEM-TOF) or TOF and point spread function modelling (OSEM-TOF+PSF). The signal-to-noise ratio and the MDA were determined. Absorbed dose estimations were performed to assess possible treatment response to high-activity 131I radioiodine therapy. The signal-to-noise ratio and the MDA were improved from the mCT to the Vision, from OSEM to OSEM-TOF and from OSEM-TOF to OSEM-TOF+PSF reconstructed images, and from shorter to longer emission times. The overall mean MDA ratio of the Vision to the mCT was 0.52 ± 0.18. The absorbed dose estimations indicate that lesions ≥ 6.5 mm with expected response to radioiodine therapy would be detectable on both systems at 4-min emission time. Additional smaller lesions of therapeutic relevance could be detected when using a SiPM-based PET system at clinically reasonable emission times. This study demonstrates that additional lesions with predicted response to 131I radioiodine therapy can be detected. Further clinical evaluation is warranted to evaluate if negative 124I PET scans on a SiPM-based system can be sufficient to preclude patients from blind radioiodine therapy.

19.
J Nucl Med ; 2021 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-34016730

RESUMEN

Purpose/Objective(s): The aim of this follow-up analysis of the ESPATUE phase-3 trial was to explore the prognostic value of post-induction chemotherapy PET metrics in patients with stage III non-small cell lung cancer (NSCLC) who were assigned to receive definitive chemoradiotherapy. Materials/Methods: All eligible patients stage IIIA (cN2) and stage IIIB of the trial received induction chemotherapy consisting of 3 cycles of cisplatin/paclitaxel and chemoradiotherapy up to 45 Gy/1.5 Gy per fraction twice-a-day, followed by a radiation-boost with 2 Gy once per day with concurrent cisplatin/vinorelbine. The protocol definition prescribed a total dose of 65-71 Gy. 18F-FDG-PET/CT (PETpre) was performed at study entry and before concurrent chemoradiotherapy (interim-PET; PETpost). Interim PETpost metrics and known prognostic clinical parameters were correlated in uni- and multivariable survival analyses. Leave-one-out cross-validation was used to show internal validity. Results: Ninety-two patients who underwent 18F-FDG-PET/CT after induction chemotherapy were enrolled. Median MTVpost value was 5.9 ml. Altogether 85 patients completed the whole chemoradiation with the planned total dose of 60-71 Gy. In univariable proportional hazard analysis, each of the parameters MTVpost, SUVmax(post) and TLGmax(post) was associated with overall survival (P < 0.05). Multivariable survival analysis, including clinical and post-induction PET parameters, found TLGmax(post) (hazard ratio: 1.032 (95%-CI: 1.013-1.052) per 100 ml increase) and total radiation dose (hazard ratio: 0.930 (0.902-0.959) per Gray increase) significantly related with overall survival in the whole group of patients, and also in patients receiving a total dose ≥ 60 Gy. The best leave-one-out cross-validated 2 parameter classifier contained TLGmax(post) and total radiation dose. TLGmax(post) was associated with time to distant metastases (P = 0.0018), and SUVmax(post) with time to loco-regional relapse (P = 0.039) in multivariable analysis of patients receiving a total dose ≥ 60 Gy. Conclusion: Post-induction chemotherapy PET parameters demonstrated prognostic significance. Therefore, an interim 18F-FDG-PET/CT is a promising diagnostic modality for guiding individualized treatment intensification.

20.
EJNMMI Res ; 11(1): 21, 2021 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-33641046

RESUMEN

AIM: [68Ga]Ga-PSMA-11 PET/CT allows for a superior detection of prostate cancer tissue, especially in the context of a low tumor burden. Digital PET/CT bears the potential of reducing scan time duration/administered tracer activity due to, for instance, its higher sensitivity and improved time coincidence resolution. It might thereby expand [68Ga]Ga-PSMA-11 PET/CT that is currently limited by 68Ge/68Ga-generator yield. Our aim was to clinically evaluate the influence of a reduced scan time duration in combination with different image reconstruction algorithms on the diagnostic performance. METHODS: Twenty prostate cancer patients (11 for biochemical recurrence, 5 for initial staging, 4 for metastatic disease) sequentially underwent [68Ga]Ga-PSMA-11 PET/CT on a digital Siemens Biograph Vision. PET data were collected in continuous-bed-motion mode with a mean scan time duration of 16.7 min (reference acquisition protocol) and 4.6 min (reduced acquisition protocol). Four iterative reconstruction algorithms were applied using a time-of-flight (TOF) approach alone or combined with point-spread-function (PSF) correction, each with 2 or 4 iterations. To evaluate the diagnostic performance, the following metrics were chosen: (a) per-region detectability, (b) the tumor maximum and peak standardized uptake values (SUVmax and SUVpeak), and (c) image noise using the liver's activity distribution. RESULTS: Overall, 98% of regions (91% of affected regions) were correctly classified in the reduced acquisition protocol independent of the image reconstruction algorithm. Two nodal lesions (each ≤ 4 mm) were not identified (leading to downstaging in 1/20 cases). Mean absolute percentage deviation of SUVmax (SUVpeak) was approximately 9% (6%) for each reconstruction algorithm. The mean image noise increased from 13 to 21% (4 iterations) and from 10 to 15% (2 iterations) for PSF + TOF and TOF images. CONCLUSIONS: High agreement at 3.5-fold reduction of scan time in terms of per-region detection (98% of regions) and image quantification (mean deviation ≤ 10%) was demonstrated; however, small lesions can be missed in about 10% of patients leading to downstaging (T1N0M0 instead of T1N1M0) in 5% of patients. Our results suggest that a reduction of scan time duration or administered [68Ga]Ga-PSMA-11 activities can be considered in metastatic patients, where missing small lesions would not impact patient management. Limitations include the small and heterogeneous sample size and the lack of follow-up.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...