Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
BMC Anesthesiol ; 23(1): 8, 2023 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-36609229

RESUMEN

BACKGROUND: Blood pressure measurement is an essential element during intraoperative patient management. However, errors caused by changes in transducer levels can occur during surgery. METHODS: This single center, prospective, observational study enrolled 25 consecutive patients scheduled for elective cardiac surgery with invasive arterial and central venous pressure (CVP) monitoring. Hydrostatic pressures caused by level differences (leveling pressure) between a reference point (on the center of the left biceps brachii muscle) and the transducers (fixed on the right side of the operating table) for arterial and central lines were continuously measured using a leveling transducer. Adjusted pressures were calculated as measured pressure - leveling pressure. Hypotension (mean arterial pressure < 80, <70, and < 60 mmHg), and CVP (< 6, ≥6 and < 15, or ≥ 15 mmHg) and pulmonary artery pressure (PAP, mean > 20 mmHg) levels were determined using unadjusted and adjusted pressures. RESULTS: Twenty-two patients were included in the analysis. Leveling pressure ≥ 3 mmHg and ≥ 5 mmHg observed at 46.0 and 18.7% of pooled data points, respectively. Determinations of hypotension using unadjusted and adjusted pressures showed disagreements ranging from 3.3 to 9.4% depending on the cutoffs. Disagreements in defined levels of CVP and PAP were observed at 23.0 and 17.2% of the data points, respectively. CONCLUSIONS: The errors in pressure measurement due to changes in transducer level were not trivial and caused variable disagreements in the determination of MAP, CVP, and PAP levels. To prevent distortions in intraoperative hemodynamic management, strategies should be sought to minimize or adjust for these errors in clinical practice. TRIAL REGISTRATION: cris.nih.go.kr (KCT0006510).


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Hipotensión , Humanos , Adulto , Presión Venosa Central/fisiología , Transductores de Presión , Estudios Prospectivos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Hipotensión/diagnóstico
2.
J Clin Med ; 10(12)2021 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-34208055

RESUMEN

BACKGROUND: Sedation using dexmedetomidine is frequently associated with hypotension. In contrast, epinephrine, a commonly used adjunctive agent in regional anesthesia, is a potent vasopressor. We hypothesized that perineural epinephrine used in brachial plexus blockade may reduce hypotension during dexmedetomidine infusion. METHODS: Patients scheduled for upper extremity surgery were randomly allocated into a control and an epinephrine group. All patients received brachial plexus blockade, consisting of 25 mL of a 1:1 mixture of 1% lidocaine and 0.75% ropivacaine, with patients in the epinephrine group also receiving 125 µg epinephrine. Intraoperative sedation was induced using dexmedetomidine at a loading dose of 1 µg/kg and maintenance dose of 0.4 µg/kg/hr. The primary outcome was the incidence of intraoperative hypotension or hypotension in the post-anesthesia care unit (PACU). RESULTS: One hundred and thirty patients were included (65 per group). The incidence of hypotension was significantly higher in the epinephrine than in the control group (80.6% vs. 56.9%, p = 0.009). The duration of hypotension and the maximal change in blood pressure were also greater in the epinephrine group. CONCLUSIONS: Perineural epinephrine for brachial plexus blockade does not reduce hypotension due to dexmedetomidine infusion and may actually augment the occurrence of hypotensive events.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...