1.
Biosens Bioelectron ; 258: 116291, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38735080

RESUMEN

Depression is one of the most common mental disorders and is mainly characterized by low mood or lack of interest and pleasure. It can be accompanied by varying degrees of cognitive and behavioral changes and may lead to suicide risk in severe cases. Due to the subjectivity of diagnostic methods and the complexity of patients' conditions, the diagnosis of major depressive disorder (MDD) has always been a difficult problem in psychiatry. With the discovery of more diagnostic biomarkers associated with MDD in recent years, especially emerging non-coding RNAs (ncRNAs), it is possible to quantify the condition of patients with mental illness based on biomarker levels. Point-of-care biosensors have emerged due to their advantages of convenient sampling, rapid detection, miniaturization, and portability. After summarizing the pathogenesis of MDD, representative biomarkers, including proteins, hormones, and RNAs, are discussed. Furthermore, we analyzed recent advances in biosensors for detecting various types of biomarkers of MDD, highlighting representative electrochemical sensors. Future trends in terms of new biomarkers, new sample processing methods, and new detection modalities are expected to provide a complete reference for psychiatrists and biomedical engineers.

2.
Biosens Bioelectron ; 255: 116090, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38569250

RESUMEN

Cardiovascular diseases (CVDs), especially chronic heart failure, threaten many patients' lives worldwide. Because of its slow course and complex causes, its clinical screening, diagnosis, and prognosis are essential challenges. Clinical biomarkers and biosensor technologies can rapidly screen and diagnose. Multiple types of biomarkers are employed for screening purposes, precise diagnosis, and treatment follow-up. This article provides an up-to-date overview of the biomarkers associated with the six main heart failure etiology pathways. Plasma natriuretic peptides (BNP and NT-proBNP) and cardiac troponins (cTnT, cTnl) are still analyzed as gold-standard markers for heart failure. Other complementary biomarkers include growth differentiation factor 15 (GDF-15), circulating Galactose Lectin 3 (Gal-3), soluble interleukin (sST2), C-reactive protein (CRP), and tumor necrosis factor-alpha (TNF-α). For these biomarkers, the electrochemical biosensors have exhibited sufficient sensitivity, detection limit, and specificity. This review systematically summarizes the latest molecular biomarkers and sensors for heart failure, which will provide comprehensive and cutting-edge authoritative scientific information for biomedical and electronic-sensing researchers in the field of heart failure, as well as patients. In addition, our proposed future outlook may provide new research ideas for researchers.


Asunto(s)
Técnicas Biosensibles , Insuficiencia Cardíaca , Humanos , Biomarcadores , Pronóstico , Péptido Natriurético Encefálico , Insuficiencia Cardíaca/diagnóstico , Proteína C-Reactiva/metabolismo , Fragmentos de Péptidos
3.
Colloids Surf B Biointerfaces ; 234: 113742, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38271855

RESUMEN

Because of the excellent performance in photochemistry, WO3 is increasingly applied in the field of biology and medicine. However, little is known about the mechanism of WO3 cytotoxicity. In this work, WO3 nanosheets with oxygen vacancy are synthesized by solvothermal method, then characterized and added to culture medium of human umbilical vein endothelial cells (HUVECs) with different concentrations. We characterized and analyzed the morphology of nano-WO3 by transmission electron microscopy and calculated the specific data of oxygen vacancy by XPS. It is the first time the effect of WO3-x on cells that WO3-x can cause oxidative stress in HUVEC cells, resulting in DNA damage and thus promoting apoptosis. Transcriptome sequencing is performed on cells treated with low and high concentrations of WO3-x, and a series of key signals affecting cell proliferation and apoptosis are detected in differentially expressed genes, which indicates the research direction of nanotoxicity. The expression levels of key genes are also verified by quantitative PCR after cell treatment with different concentrations of WO3-x. This work fills the gap between the biocompatibility of nano WO3-x materials and molecular cytology and paves the way for investigating the mechanism and risks of oxygen vacancy in cancer therapy.


Asunto(s)
Óxidos , Oxígeno , Humanos , Células Endoteliales de la Vena Umbilical Humana , Óxidos/química , Tungsteno/toxicidad , Tungsteno/química
4.
Dalton Trans ; 52(36): 12988-12998, 2023 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-37650562

RESUMEN

Given the worldwide increase in diabetes, there is an urgent need for glucose sensors that can achieve the on-body detection of glucose concentration. With the development of nanomaterials and flexible electronics, wearable electrochemical enzyme-free glucose biosensors that can conveniently, continuously and stably monitor the glucose concentrations of diabetes patients without invasion and risk of infection are coming into focus. However, despite the enormous efforts toward wearable electrochemical enzyme-free glucose sensors, there have been limited achievements in developing a stretchable and breathable glucose sensor with high sensitivity, low detection limit, and excellent catalytic activity towards glucose oxidation in neutral media, to meet the need for continuous wearable glucose monitoring in scenarios such as the on-body detection of glucose in human sweat. Herein, we demonstrate a novel electrochemical enzyme-free glucose-sensing patch on the foundation of electrospun polyurethane (PU) fibrous mats to address some of the aforementioned challenges. The sensing patch was fabricated through a facile technology of electrospinning, followed by magnetron sputtering of gold (Au) to enable high conductivity. After that, ultrasonic-assisted electrodeposition was utilized to in situ introduce well-dispersed platinum nano pine needles along each fiber. Due to the good stretchability of PU materials, porous structure, and large specific surface area of electrochemical sites, the glucose-sensing patch promises merits such as good stretchability (performs well under 10% strain), high sensitivity (203.13 µA mM-1 cm-1), prominently low detection limit (14.77 µM), excellent selectivity, and efficient vapor permeability. Notably, the advanced hierarchical nanostructures with excellent catalytic activity towards glucose oxidation could be capable of detecting glucose in neutral conditions (pH = 7.4) without the assistance of enzymes. Given the facile fabrication methods and the integrated superior performances, this enzyme-free glucose-sensing patch could play a vital role in wearable glucose sensors.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Humanos , Platino (Metal) , Electrónica , Glucosa
5.
Micromachines (Basel) ; 14(8)2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37630086

RESUMEN

Integrated periodic structure reference materials are crucial for calibration in optical instruments and micro-computed tomography (micro-CT), yet they face limitations concerning a restricted measurement range, a single pattern type, and a single calibration parameter. In this study, we address these challenges by developing integrated periodic structure reference materials with an expanded measurement range, diverse pattern types, and multiple calibration parameters through a combination of photolithography and inductively coupled plasma (ICP) etching process. These reference materials facilitate high-efficiency and multi-value calibration, finding applications in the calibration of optical instruments and micro-CT systems. The simulations were conducted using MATLAB (R2022b) to examine the structure-morphology changes during the single-step ICP etching process. The variation rules governing line widths, periods, etching depths, and side wall verticality in integrated periodic structure reference materials were thoroughly evaluated. Linewidths were accurately extracted utilizing an advanced image processing algorithm, while average period values were determined through the precise Fast Fourier Transform method. The experimental results demonstrate that the relative errors of line widths do not exceed 17.5%, and the relative errors of periods do not exceed 1.5%. Furthermore, precise control of the etching depth was achieved, ranging from 30 to 60 µm for grids with line widths 2-20 µm. The side wall verticality exhibited remarkable consistency with an angle of 90° ± 0.8°, and its relative error was found to be less than 0.9%.

6.
Micromachines (Basel) ; 14(4)2023 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-37421088

RESUMEN

With polymerization duration and Au3+ concentration of the electrolyte regulated, a desirable nitrate-doped polypyrrole ion-selective membrane (PPy(NO3-)-ISM) and Au solid contact layer of anticipate surface morphology were obtained, and the performance of nitrate all-solid ion-selective electrodes (NS ISEs) was improved. It was found that the roughest PPy(NO3-)-ISM remarkably increases the actual contact surface area of the PPy(NO3-)-ISMs with nitrate solution, which leads to better adsorption of NO3- ions upon the PPy(NO3-)-ISMs, and produces a larger number of electrons. The most hydrophobic Au solid contact layer avoids the formation of the aqueous layer at the interface between the PPy(NO3-)-ISM and Au solid contact layer, and ensures unimpeded transporting of the produced electrons. The PPy-Au-NS ISE for polymerization duration 1800 s and at Au3+ concentration 2.5 mM of the electrolyte displays an optimal nitrate potential response, including a Nernstian slope of 54.0 mV/dec, LOD of 1.1 × 10-4 M, rapid average response time less than 1.9 s, and long-term stability of more than 5 weeks. This indicates that the PPy-Au-NS ISE is an effective working electrode for the electrochemical determination of NO3- concentration.

7.
Nanomaterials (Basel) ; 13(4)2023 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-36838999

RESUMEN

GaN high-electron-mobility transistor (HEMT) terahertz (THz) detectors have been widely studied and applied in the past few decades. However, there are few reports about the influence of GaN/AlGaN heterostructure material properties on the detection model at present. In this paper, a response voltage model for a GaN HEMT THz detector that considers the carrier scattering in a GaN/AlGaN heterostructure is proposed. The phonon scattering, dislocation scattering, and interface roughness scattering mechanisms are taken into account in the classic THz response voltage model; furthermore, the influence of various material parameters on the response voltage is studied. In a low-temperature region, acoustic scattering plays an important role, and the response voltage drops with an increase in temperature. In a high temperature range, optical phonon scattering is the main scattering mechanism, and the detector operates in a non-resonant detection mode. With an increase in carrier surface density, the response voltage decreases and then increases due to piezoelectric scattering and optical phonon scattering. For dislocation and interface roughness scattering, the response voltage is inversely proportional to the dislocation density and root mean square roughness (RMS) but is positively related to lateral correlation length. Finally, a comparison between our model and the reported models shows that our proposed model is more accurate.

8.
Nanotechnology ; 34(1)2022 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-36191554

RESUMEN

In this study, reduced graphene oxide (rGO) were subject to ultrasonic treatment to acquire varied morphologies, and the enzymatic glucose sensors were constructed by coating the rGO onto indium tin oxide electrodes and physically linking glucose oxidase to the rGO coatings. The effects of the surface morphologies of the rGO coatings on the interfacial characteristics and the electro-catalytic capacity of the enzymatic glucose sensors were systematically investigated. It turns out that, the rGO coating with a rough surface is more hydrophilic, and exhibits uniform glucose oxidase adsorption and higher electron migration rate at the solid/liquid interface between the analytical liquid and the working electrode. As a result, the corresponding glucose sensor shows excellent electro-catalytic capacity towards glucose with a broader linear range of 0-10.0 mM, a higher sensitivity of 38.9µA·mM-1·cm-2, and a lower detection limit of 0.1µM (signal-to-noise ratio of 3). Additionally, the as-prepared glucose sensor exhibits excellent accuracy for detecting actual blood samples as well as superior resistance to interference from other substances (such as L-phenylalanine, urea, ascorbic acid, uric acid, NaCl, and KCl). These results establish the theoretical and experimental foundation for the application of rGO coating in the field of biosensors.


Asunto(s)
Técnicas Biosensibles , Grafito , Glucosa Oxidasa , Ácido Úrico , Cloruro de Sodio , Técnicas Biosensibles/métodos , Electrodos , Glucosa , Ácido Ascórbico , Urea , Fenilalanina , Técnicas Electroquímicas/métodos
9.
Micromachines (Basel) ; 13(9)2022 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-36144077

RESUMEN

Nano-steps, as classical nano-geometric reference materials, are very important for calibrating measurements in the semiconductor industry; therefore, controlling the height of nano-steps is critical for ensuring accurate measurements. Accordingly, in this study nano-steps with heights of 1, 2, 3 and 4 nm were fabricated with good morphology using atomic layer deposition (ALD) combined with wet etching. The roughness of the fabricated nano-steps was effectively controlled by utilizing the three-dimensional conformal ALD process. Moreover, the relationship between the surface roughness and the height was studied using a simulation-based analysis. Essentially, roughness control is crucial in fabricating nano-steps with a critical dimension of less than 5 nm. In this study, the minimum height of a nano-step that was successfully achieved by combining ALD and wet etching was 1 nm. Furthermore, the preconditions for quality assurance for a reference material and the influencing factors of the fabrication method were analyzed based on the 1 nm nano-step sample. Finally, the fabricated samples were used in time-dependent experiments to verify the optimal stability of the nano-steps as reference materials. This research is instructive to fabricate nano-geometric reference materials to within 5 nm in height, and the proposed method can be easily employed to manufacture wafer-sized step height reference materials, thus enabling its large-scale industrial application for in-line calibration in integrated circuit production lines.

10.
Micromachines (Basel) ; 13(7)2022 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-35888812

RESUMEN

A nano-grating standard with accurate linewidth can not only calibrate the magnification of nano-measurement instruments, but can also enable comparison of linewidths. Unfortunately, it is still a challenging task to control the linewidth of nano-grating standards. Accordingly, in this paper, atomic layer deposition (ALD) was used to regulate the linewidth of the one-dimensional grating standards with a pitch of 1000 nm, fabricated by electron beam lithography (EBL). The standards were measured using an atomic force microscope (AFM) before and after ALD, and the linewidth and pitch of the grating were calculated through the gravity center method. The obtained results prove that the width of a single grating line in the standard can be regulated with great uniformity by precisely utilizing ALD. Meanwhile, the proposed method does not affect the pitch of grating, and the measurement uncertainty of standards is less than 0.16% of the pitch, thereby demonstrating a high surface quality and calibration reliability of the standards, and realizing the integration of linewidth and pitch calibration functions. Moreover, the precise and controllable fabrication method of the micro-nano periodic structure based on ALD technology has many potential applications in the fields of optoelectronic devices and biosensors.

11.
Micromachines (Basel) ; 13(5)2022 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-35630258

RESUMEN

A side ohmic contact mode for the double channel GaN/AlGaN epitaxial layer is proposed in this paper. Rectangle transmission line model (TLM) electrodes are prepared, and the specific contact resistance is tested at the annealing temperatures from 700 °C to 850 °C. The results show that the minimum specific contact resistance is 2.58 × 10-7 Ω·cm2 at the annealing temperature of 750 °C, which is three to four times lower than the surface contact mode. Scanning electron microscope (SEM), energy dispersive spectrometer (EDS), and atomic force microscope (AFM) were carried out for the analysis of the morphology, element composition, and the height fluctuation at the contact edge. With the increase in the annealing temperature, the specific contact resistance decreases due to the alloying of electrodes and the raised number of N vacancies. However, when the annealing temperature exceeds 800 °C, the state of the stress in the electrode films transforms from compressive stress to tensile stress. Besides, the volume expansion of metal electrode film and the increase in the roughness at the contact edge leads to the degradation of the side ohmic contact characteristics.

12.
Materials (Basel) ; 14(20)2021 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-34683785

RESUMEN

A double-channel (DC) GaN/AlGaN high-electron-mobility transistor (HEMT) as a terahertz (THz) detector at 315 GHz frequency is proposed and fabricated in this paper. The structure of the epitaxial layer material in the detector is optimized, and the performance of the GaN HEMT THz detector is improved. The maximum responsivity of 10 kV/W and minimum noise equivalent power (NEP) of 15.5 pW/Hz0.5 are obtained at the radiation frequency of 315 GHz. The results are comparable to and even more promising than the reported single-channel (SC) GaN HEMT detectors. The enhancement of THz response and the reduction of NEP of the DC GaN HEMT detector mainly results from the interaction of 2DEG in the upper and lower channels, which improves the self-mixing effect of the detector. The promising experimental results mean that the proposed DC GaN/AlGaN HEMT THz detector is capable of the practical applications of THz detection.

13.
Micromachines (Basel) ; 12(8)2021 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-34442599

RESUMEN

A novel and efficient enzymatic glucose sensor was fabricated based on Fe3O4 magnetic nanoparticles (Fe3O4MNPs)-modified urchin-like ZnO nanoflowers (ZnONFs). ZnONFs were hydrothermally synthesizing on a flexible PET substrate. Fe3O4MNPs were deposited on the surface of the ZnONFs by the drop-coating process. The results showed that the urchin-like ZnONFs provided strong support for enzyme adsorption. For Fe3O4MNPs, it significantly promoted the redox electron transfer from the active center of GOx to the ZnO nanoflowers beneath. More importantly, it promoted the hydrolysis of H2O2, the intermediate product of glucose catalytic reaction, and thus improved the electron yield. The sensitivity of the Nafion/GOx/Fe3O4MNPs/ZnONFs/Au/PET sensor was up to 4.52 µA·mM-1·cm-2, which was improved by 7.93 times more than the Nafion/GOx/ZnONFs/Au/PET sensors (0.57 µA·mM-1·cm-2). The detection limit and linear range were also improved. Additionally, the as-fabricated glucose sensors show strong anti-interference performance in the test environment containing organic compounds (such as urea, uric acid, and ascorbic acid) and inorganic salt (for instance, NaCl and KCl). The glucose sensor's service life was evaluated, and it can still maintain about 80% detection performance when it was reused about 20 times. Compared with other existing sensors, the as-fabricated glucose sensor exhibits an ultrahigh sensitivity and wide detection range. In addition, the introduction of Fe3O4MNPs optimized the catalytic efficiency from the perspective of the reaction mechanism and provided potential ideas for improving the performance of other enzymatic biosensors.

14.
Langmuir ; 37(26): 7890-7906, 2021 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-34152754

RESUMEN

Six CuO/ZnO nanorod (CuO/ZnONR)-based microfluidic reactors were constructed for different UV irradiation durations, with which an aqueous methylene blue (MB) solution was photodegraded at varied volume flow rate Q. Via numerical and experimental routes, the effects of the Q on the kinetic adsorption rate constant Ka and the initial rate constant KA of the CuO/ZnONR-based microfluidic reactors were discussed. Moreover, a reverse contacting angle (CA) trend of CuO/ZnONRs to the reaction constant K curve of corresponding CuO/ZnONR-based microfluidic reactor suggested that the CA of CuO/ZnONRs was another key influencing factor that affected greatly the photodegradation performance of the microfluidic reactors. The Q of the aqueous MB solution and the UV irradiation duration for the photodeposition of CuO/ZnONRs were optimized to be 125 µL/min and 1.0 h, the K of the CuO/ZnONR-based microfluidic reactors reached 4.84 min-1, and the related ΔKA/K was less than 6%. Similarly, these methods and results can be employed not only to enhance the mass transport and adsorption of specific species within other nanostructured matrix material-coated microchannels but also to enlarge the actual contacting surface areas between these microchannels and the related solution, which further improve the performance of other nanostructured catalyst-based microfluidic reactors, rGO microfluidic voltage generation, and a GOx/AuNW enzymatic glucose microfluidic sensor.


Asunto(s)
Óxido de Zinc , Bencenosulfonatos , Cobre , Microfluídica , Fotólisis , Humectabilidad
15.
J Nanosci Nanotechnol ; 19(9): 5608-5618, 2019 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-30961715

RESUMEN

ZnO nanorods (ZnONRs) were hydrothermally synthesized on stainless-steel wire (SSW) sieves of various mesh sizes at different Zn2+ concentrations of the growth solution, and then treated with stearic acid (SA) for a specific duration. Using these SSW sieve-supported ZnONRs, a mixture of de-ionized (DI) water and diesel oil was separated. It was found that the SA treatment dramatically diminished the quantity of surface hydroxyl groups attached to the top and upper portions of the ZnONRs, and thus significantly enhanced the hydrophobicity of the ZnONR-coated SSW sieves. The synthesis parameters remarkably affected the surface morphology and wettability of the ZnONRs on the SSWs, which in combination with the mesh size of the SSW sieve, influenced the contact angles (CA) of the ZnONR-coated SSW sieves and the separation efficiency for DI water and diesel oil. In each batch, the ZnONR-coated SSW sieves with mesh sizes of 300, 200, and 100 produced at Zn2+ concentrations of 125, 100, and 25 mM of the growth solution had the most desirable surface morphology, and were the most hydrophobic and oleophilic; further, they gave the optimal separation efficiencies of 93%, 95%, and 90% respectively. Thus, the ZnONR-coated SSW sieve with a mesh size of 200 prepared at Zn2+ concentration of 100 mM of the growth solution can be employed as an effective separator of water and diesel oil.

16.
Sensors (Basel) ; 18(4)2018 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-29570680

RESUMEN

An In2O3/ITO thin film thermocouple was prepared via screen printing. Glass additives were added to improve the sintering process and to increase the density of the In2O3/ITO films. The surface and cross-sectional images indicate that both the grain size and densification of the ITO and In2O3 films increased with the increase in annealing time. The thermoelectric voltage of the In2O3/ITO thermocouple was 53.5 mV at 1270 °C at the hot junction. The average Seebeck coefficient of the thermocouple was calculated as 44.5 µV/°C. The drift rate of the In2O3/ITO thermocouple was 5.44 °C/h at a measuring time of 10 h at 1270 °C.

17.
Sensors (Basel) ; 17(10)2017 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-28953217

RESUMEN

In this paper, the performance of a zinc oxide (ZnO) nanorod-based enzymatic glucose sensor was enhanced with silver (Ag)-doped ZnO (ZnO-Ag) nanorods. The effect of the doped Ag on the surface morphologies, wettability, and electron transfer capability of the ZnO-Ag nanorods, as well as the catalytic character of glucose oxidase (GOx) and the performance of the glucose sensor was investigated. The results indicate that the doped Ag slightly weakens the surface roughness and hydrophilicity of the ZnO-Ag nanorods, but remarkably increases their electron transfer ability and enhances the catalytic character of GOx. Consequently, the combined effects of the above influencing factors lead to a notable improvement of the performance of the glucose sensor, that is, the sensitivity increases and the detection limit decreases. The optimal amount of the doped Ag is determined to be 2 mM, and the corresponding glucose sensor exhibits a sensitivity of 3.85 µA/(mM·cm²), detection limit of 1.5 µM, linear range of 1.5 × 10-3-6.5 mM, and Michaelis-Menten constant of 3.87 mM. Moreover, the glucose sensor shows excellent selectivity to urea, ascorbic acid, and uric acid, in addition to displaying good storage stability. These results demonstrate that ZnO-Ag nanorods are promising matrix materials for the construction of other enzymatic biosensors.


Asunto(s)
Técnicas Biosensibles/métodos , Técnicas de Química Analítica/métodos , Glucosa/análisis , Nanotubos/química , Plata/química , Óxido de Zinc/química , Técnicas de Química Analítica/instrumentación , Glucosa Oxidasa/metabolismo
18.
Sensors (Basel) ; 17(4)2017 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-28420088

RESUMEN

A thermal stress range analysis of tungsten-rhenium thin film thermocouples based on ceramic substrates is presented to analyze the falling off and breakage problems caused by the mismatch of the thermal stresses in thin film thermocouples (TFTCs) and substrate, and nano-indentation experiments are done to measure and calculate the film stress to compare with the simulation results. Optimal design and fabrication of tungsten-rhenium TFTCs based on ceramic substrates is reported. Static high temperature tests are carried out, which show the optimization design can effectively reduce the damage caused by the thermal stress mismatch.

19.
Rev Sci Instrum ; 88(1): 015007, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28147639

RESUMEN

A tungsten-rhenium thin film thermocouple is designed and fabricated, depending on the principle of thermal-electric effect caused by the high temperature. The characteristics of thin film thermocouples in different temperatures are investigated via numerical analysis and analog simulation. The working mechanism and thermo-electric features of the thermocouples are analyzed depending on the simulation results. Then the thin film thermocouples are fabricated and calibrated. The calibration results show that the thin film thermocouples based on the tungsten-rhenium material achieve ideal static characteristics and work well in the practical applications.

20.
J Nanosci Nanotechnol ; 16(1): 873-7, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27398539

RESUMEN

This paper investigates optical characteristics of ZnO/Cu/ZnO multilayer optical thin film by numerical simulation and it is further verified by experiments. The influences of Cu and ZnO thickness on the optical characteristics of ZnO/Cu/ZnO thin films are studied. The results show that the transmittances of ZnO/Cu/ZnO thin film decrease with the increase of thickness of Cu layer but are nonlinear with the ZnO thickness. The maximal light transmission in the visible region is obtained by controlling the thickness of Cu and ZnO films.

SELECCIÓN DE REFERENCIAS