1.
Biosensors (Basel) ; 13(12)2023 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-38131769

RESUMEN

C-reactive protein is a well-studied host response biomarker, whose diagnostic performance depends on its accurate classification into concentration zones defined by clinical scenario-specific cutoff values. We validated a newly developed, bead-based, bound-free phase detection immunoassay (BFPD-IA) versus a commercial CE-IVD enzyme-linked immunosorbent assay (ELISA) kit and a commercial CE-IVD immunoturbidimetric assay (ITA) kit. The latter was performed on a fully automated DPC Konelab 60i clinical analyzer used in routine diagnosis. We classified 53 samples into concentration zones derived from four different sets of cutoff values that are related to antibiotic prescription scenarios in the case of respiratory tract infections. The agreements between the methods were ELISA/ITA at 87.7%, ELISA/BFPD-IA at 87.3%, and ITA/-BFPD-IA at 93.9%, reaching 98-99% in all cases when considering the calculated relative combined uncertainty of the single measurement of each sample. In a subgroup of 37 samples, which were analyzed for absolute concentration quantification, the scatter plot slopes' correlations were as follows: ELISA/ITA 1.15, R2 = 0.97; BFPD-IA/ELISA 1.12, R2 = 0.95; BFPD-IA/ITA 0.95, R2 = 0.93. These very good performances and the agreement between BFPD-IA and ITA (routine diagnostic), combined with BFPD-IA's functional advantages over ITA (and ELISA)-such as quick time to result (~20 min), reduced consumed reagents (only one assay buffer and no washing), few and easy steps, and compatibility with nucleic-acid-amplification instruments-render it a potential approach for a reliable, cost-efficient, evidence-based point-of-care diagnostic test for guiding antibiotic prescriptions.


Asunto(s)
Proteína C-Reactiva , Humanos , Proteína C-Reactiva/análisis , Inmunoensayo/métodos , Ensayo de Inmunoadsorción Enzimática/métodos , Biomarcadores
2.
Biosensors (Basel) ; 12(6)2022 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-35735560

RESUMEN

In this paper, we present the ImmunoDisk, a fully automated sample-to-answer centrifugal microfluidic cartridge, integrating a heterogeneous, wash-free, magnetic- and fluorescent bead-based immunoassay (bound-free phase detection immunoassay/BFPD-IA). The BFPD-IA allows the implementation of a simple fluidic structure, where the assay incubation, bead separation and detection are performed in the same chamber. The system was characterized using a C-reactive protein (CRP) competitive immunoassay. A parametric investigation on air drying of protein-coupled beads for pre-storage at room temperature is presented. The key parameters were buffer composition, drying temperature and duration. A protocol for drying two different types of protein-coupled beads with the same temperature and duration using different drying buffers is presented. The sample-to-answer workflow was demonstrated measuring CRP in 5 µL of human serum, without prior dilution, utilizing only one incubation step, in 20 min turnaround time, in the clinically relevant concentration range of 15-115 mg/L. A reproducibility assessment over three disk batches revealed an average signal coefficient of variation (CV) of 5.8 ± 1.3%. A CRP certified reference material was used for method verification with a concentration CV of 8.6%. Our results encourage future testing of the CRP-ImmunoDisk in clinical studies and its point-of-care implementation in many diagnostic applications.


Asunto(s)
Proteína C-Reactiva , Microfluídica , Humanos , Inmunoensayo/métodos , Indicadores y Reactivos , Reproducibilidad de los Resultados
3.
Biosensors (Basel) ; 11(11)2021 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-34821641

RESUMEN

Periodontitis and dental caries are two major bacterially induced, non-communicable diseases that cause the deterioration of oral health, with implications in patients' general health. Early, precise diagnosis and personalized monitoring are essential for the efficient prevention and management of these diseases. Here, we present a disk-shaped microfluidic platform (OralDisk) compatible with chair-side use that enables analysis of non-invasively collected whole saliva samples and molecular-based detection of ten bacteria: seven periodontitis-associated (Aggregatibacter actinomycetemcomitans, Campylobacter rectus, Fusobacterium nucleatum, Prevotella intermedia, Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola) and three caries-associated (oral Lactobacilli, Streptococcus mutans, Streptococcus sobrinus). Each OralDisk test required 400 µL of homogenized whole saliva. The automated workflow included bacterial DNA extraction, purification and hydrolysis probe real-time PCR detection of the target pathogens. All reagents were pre-stored within the disk and sample-to-answer processing took < 3 h using a compact, customized processing device. A technical feasibility study (25 OralDisks) was conducted using samples from healthy, periodontitis and caries patients. The comparison of the OralDisk with a lab-based reference method revealed a ~90% agreement amongst targets detected as positive and negative. This shows the OralDisk's potential and suitability for inclusion in larger prospective implementation studies in dental care settings.


Asunto(s)
Caries Dental , Técnicas Analíticas Microfluídicas , Salud Bucal , Periodontitis , Saliva/microbiología , Caries Dental/diagnóstico , Humanos , Periodontitis/diagnóstico
4.
Sci Rep ; 11(1): 6406, 2021 03 19.
Artículo en Inglés | MEDLINE | ID: mdl-33742017

RESUMEN

Oral health is important not only due to the diseases emerging in the oral cavity but also due to the direct relation to systemic health. Thus, early and accurate characterization of the oral health status is of utmost importance. There are several salivary biomarkers as candidates for gingivitis and periodontitis, which are major oral health threats, affecting the gums. These need to be verified and validated for their potential use as differentiators of health, gingivitis and periodontitis status, before they are translated to chair-side for diagnostics and personalized monitoring. We aimed to measure 10 candidates using high sensitivity ELISAs in a well-controlled cohort of 127 individuals from three groups: periodontitis (60), gingivitis (31) and healthy (36). The statistical approaches included univariate statistical tests, receiver operating characteristic curves (ROC) with the corresponding Area Under the Curve (AUC) and Classification and Regression Tree (CART) analysis. The main outcomes were that the combination of multiple biomarker assays, rather than the use of single ones, can offer a predictive accuracy of > 90% for gingivitis versus health groups; and 100% for periodontitis versus health and periodontitis versus gingivitis groups. Furthermore, ratios of biomarkers MMP-8, MMP-9 and TIMP-1 were also proven to be powerful differentiating values compared to the single biomarkers.


Asunto(s)
Gingivitis/diagnóstico , Gingivitis/metabolismo , Salud Bucal , Periodontitis/diagnóstico , Periodontitis/metabolismo , Saliva/metabolismo , Adulto , Área Bajo la Curva , Biomarcadores/metabolismo , Estudios de Casos y Controles , Estudios de Cohortes , Estudios Transversales , Ensayo de Inmunoadsorción Enzimática/métodos , Femenino , Humanos , Masculino , Metaloproteinasa 8 de la Matriz/metabolismo , Metaloproteinasa 9 de la Matriz/metabolismo , Persona de Mediana Edad , Curva ROC , Inhibidor Tisular de Metaloproteinasa-1/metabolismo
5.
Anal Chim Acta ; 1153: 338280, 2021 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-33714441

RESUMEN

We present a simple and fast one-step heterogeneous immunoassay, with performance characteristics that can enable easy and versatile adaptation to miniaturized, automated point-of-care systems. This novel analytical method uses magnetic and fluorescent beads as capture and detection agents respectively. Its main feature is the measurement of the fluorescent signal in the bound-free phase for (semi-)quantitative detection of analytes. Thus, no washing is required and the workflow consists only of sample and reagent supply, incubation, separation and detection. The immunoassay concept is demonstrated with C-reactive protein (CRP), a systemic inflammation marker. CRP in only 5 µL of undiluted serum was measured in the range 20-140 mg L-1 (includes clinically relevant cut-off values). The limit of detection (LOD) was 22.1 ± 6.3 mg L-1 (incubation 15 min). A CRP certified reference material was measured on five different days. Intra- and inter-assay coefficients of variation were 4.6 ± 1.9% and 5.6% respectively. To demonstrate the compatibility of the assay concept with additional matrices and concentration ranges, three oral inflammation markers, namely matrix metalloproteinases 8 and 9 (MMP-8, MMP-9) and tissue inhibitor of metalloproteinases 1 (TIMP-1), were measured in saliva in the ranges 0.47-30 ng mL-1 for MMP-8 and MMP-9, and 0.69-44 ng mL-1 for TIMP-1. LODs were 0.24 ng mL-1, 0.38 ng mL-1 and 0.39 ng mL-1 respectively (incubation 20 min). Multiplexing capacity of the assay concept was also shown with these markers. The demonstrated excellent reproducibility of the results, combined with the versatility and low complexity of the introduced immunoassay concept, make it an attractive candidate for applied analytical chemistry and automated point-of-care testing.


Asunto(s)
Proteína C-Reactiva , Sistemas de Atención de Punto , Inmunoensayo , Límite de Detección , Reproducibilidad de los Resultados
6.
Antibiotics (Basel) ; 9(11)2020 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-33202544

RESUMEN

Antibiotic resistance poses a global threat, which is being acknowledged at several levels, including research, clinical implementation, regulation, as well as by the World Health Organization. In the field of oral health, however, the issue of antibiotic resistances, as well as of accurate diagnosis, is underrepresented. Oral diseases in general were ranked third in terms of expenditures among the EU-28 member states in 2015. Yet, the diagnosis and patient management of oral infections, in particular, still depend primarily on empiric means. On the contrary, on the global scale, the field of medical infections has more readily adopted the integration of molecular-based systems in the diagnostic, patient management, and antibiotic stewardship workflows. In this perspective review, we emphasize the clinical significance of supporting in the future antibiotic resistance screening in dental practice with novel integrated and point-of-care operating tools that can greatly support the rapid, accurate, and efficient administration of oral antibiotics.

7.
Analyst ; 145(21): 7040-7047, 2020 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-33103683

RESUMEN

We present the RespiDisk enabling the fully automated and multiplex point-of-care (POC) detection of (currently) up to 19 respiratory tract infection (RTI) pathogens from a single sample based on reverse transcriptase polymerase chain reaction (RT-PCR). RespiDisk comprises a RTI-specific implementation of the centrifugal microfluidic LabDisk platform and combines new and existing advanced unit operations for liquid control, thereby automating all assay steps only by a spinning frequency and temperature protocol in combination with the use of a permanent magnet for in situ bead handing. The capabilities of the system were demonstrated with 36 tested quality samples mimicking clinical conditions (clinical and/or cultured material suspended in transport medium or synthetic bronchoalveolar lavage (BAL)) from past external quality assessment (EQA) panels covering 13 of the 19 integrated RTI detection assays. In total, 36 samples × 19 assays/sample resulting in 684 assays were performed with the RespiDisk, and its analytical performance was in full agreement with the routine clinical workflow serving as reference. A strong feature of the platform is its universality since its components allow the simultaneous detection of a broad panel of bacteria and viruses in a single run, thereby enabling the differentiation between antibiotic-treatable diseases. Furthermore, the full integration of all necessary biochemical components enables a reduction of the hands-on time from manual to automated sample-to-answer analysis to about 5 min. The study was performed on an air-heated LabDisk Player instrument with a time-to-result of 200 min.


Asunto(s)
Infecciones del Sistema Respiratorio , Virus , Bacterias , Humanos , Microfluídica , Sistemas de Atención de Punto , Infecciones del Sistema Respiratorio/diagnóstico
8.
Stud Health Technol Inform ; 273: 234-239, 2020 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-33087618

RESUMEN

Respiratory Tract Infections (RTIs) are among the top reasons for visiting a General Practitioner (GP) and the main cause of unnecessary antibiotic prescriptions. Reducing inappropriate use is essential to decrease antibiotic resistance and adverse events. The goal of the Eurostars project "Respiotic" is to develop a new point-of-care (POC) platform based on the centrifugal microfluidic LabDisk that will detect the main responsible viruses and bacteria for community-acquired RTIs, including associated resistances and host biomarkers. The diagnostic platform will use a Polymerase Chain Reaction (PCR) and an immunoassay cartridge on the same instrument and provide the combined analysis within less than 1 h. An electronic clinical algorithm will co-assess the test results and act as a decision support tool for the GPs' patient management and prescriptions.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Infecciones del Sistema Respiratorio , Algoritmos , Humanos , Sistemas de Atención de Punto , Prescripciones , Infecciones del Sistema Respiratorio/diagnóstico
9.
Micromachines (Basel) ; 10(12)2019 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-31801193

RESUMEN

Saliva offers many advantages for point-of-care (PoC) diagnostic applications due to non-invasive, easy, and cost-effective methods of collection. However, the complex matrix with its non-Newtonian behavior and high viscosity poses handling challenges. Several tedious and long pre-analytic steps, incompatible with PoC use, are required to liquefy and homogenize saliva samples before protein analysis can be performed. We apply magnet-beating to reduce hands-on time and to simplify sample preparation. A magnet in a chamber containing the whole saliva is actuated inside a centrifugal microfluidic cartridge by the interplay of centrifugal and magnetic forces. Rigorous mixing, which homogenizes the saliva sample, is then initiated. Consequently, fewer manual steps are required to introduce the whole saliva into the cartridge. After 4 min of magnet-beating, the processed sample can be used for protein analysis. The viscosity of whole saliva has been reduced from 10.4 to 2.3 mPa s. Immunoassay results after magnet-beating for three salivary periodontal markers (MMP-8, MMP-9, TIMP-1) showed a linear correlation with a slope of 0.99 when compared to results of reference method treated samples. Conclusively, magnet-beating has been shown to be a suitable method for the pre-analytic processing of whole saliva for fully automated PoC protein analysis.