1.
Phys Med Biol ; 66(23)2021 11 29.
Artículo en Inglés | MEDLINE | ID: mdl-34706355

RESUMEN

This work provides a quantitative assessment of helium ion CT (HeCT) for particle therapy treatment planning. For the first time, HeCT based range prediction accuracy in a heterogeneous tissue phantom is presented and compared to single-energy x-ray CT (SECT), dual-energy x-ray CT (DECT) and proton CT (pCT). HeCT and pCT scans were acquired using the US pCT collaboration prototype particle CT scanner at the Heidelberg Ion-Beam Therapy Center. SECT and DECT scans were done with a Siemens Somatom Definition Flash and converted to RSP. A Catphan CTP404 module was used to study the RSP accuracy of HeCT. A custom phantom of 20 cm diameter containing several tissue equivalent plastic cubes was used to assess the spatial resolution of HeCT and compare it to DECT. A clinically realistic heterogeneous tissue phantom was constructed using cranial slices from a pig head placed inside a cylindrical phantom (ø150 mm). A proton beam (84.67 mm range) depth-dose measurement was acquired using a stack of GafchromicTM EBT-XD films in a central dosimetry insert in the phantom. CT scans of the phantom were acquired with each modality, and proton depth-dose estimates were simulated based on the reconstructions. The RSP accuracy of HeCT for the plastic phantom was found to be 0.3 ± 0.1%. The spatial resolution for HeCT of the cube phantom was 5.9 ± 0.4 lp cm-1for central, and 7.6 ± 0.8 lp cm-1for peripheral cubes, comparable to DECT spatial resolution (7.7 ± 0.3 lp cm-1and 7.4 ± 0.2 lp cm-1, respectively). For the pig head, HeCT, SECT, DECT and pCT predicted range accuracy was 0.25%, -1.40%, -0.45% and 0.39%, respectively. In this study, HeCT acquired with a prototype system showed potential for particle therapy treatment planning, offering RSP accuracy, spatial resolution, and range prediction accuracy comparable to that achieved with a commercial DECT scanner. Still, technical improvements of HeCT are needed to enable clinical implementation.


Asunto(s)
Helio , Protones , Animales , Helio/uso terapéutico , Fantasmas de Imagen , Plásticos , Porcinos , Tomografía Computarizada por Rayos X , Rayos X
2.
Phys Med Biol ; 65(19): 195001, 2020 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-32575084

RESUMEN

Proton computed tomography (pCT) has high accuracy and dose efficiency in producing spatial maps of the relative stopping power (RSP) required for treatment planning in proton therapy. With fluence-modulated pCT (FMpCT), prescribed noise distributions can be achieved, which allows to decrease imaging dose by employing object-specific dynamically modulated fluence during the acquisition. For FMpCT acquisitions we divide the image into region-of-interest (ROI) and non-ROI volumes. In proton therapy, the ROI volume would encompass all treatment beams. An optimization algorithm then calculates dynamically modulated fluence that achieves low prescribed noise inside the ROI and high prescribed noise elsewhere. It also produces a planned noise distribution, which is the expected noise map for that fluence, as calculated with a Monte Carlo simulation. The optimized fluence can be achieved by acquiring pCT images with grids of intensity modulated pencil beams. In this work, we interfaced the control system of a clinical proton beam line to deliver the optimized fluence. Using three phantoms we acquired images with uniform fluence, with a constant noise prescription, and with an FMpCT task. Image noise distributions as well as fluence maps were compared to the corresponding planned distributions as well as to the prescription. Furthermore, we propose a correction method that removes image artifacts stemming from the acquisition with pencil beams having a spatially varying energy distribution that is not seen in clinical operation. RSP accuracy of FMpCT scans was compared to uniform scans and was found to be comparable to standard pCT scans. While we identified technical improvements for future experimental acquisitions, in particular related to an unexpected pencil beam size reduction and a misalignment of the fluence pattern, agreement with the planned noise was satisfactory and we conclude that FMpCT optimized for specific image noise prescriptions is experimentally feasible.


Asunto(s)
Algoritmos , Método de Montecarlo , Fantasmas de Imagen , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos
3.
Med Phys ; 47(4): 1895-1906, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32040212

RESUMEN

PURPOSE: Fluence-modulated proton computed tomography (FMpCT) using pencil beam scanning aims at achieving task-specific image noise distributions by modulating the imaging proton fluence spot-by-spot based on an object-specific noise model. In this work, we present a method for fluence field optimization and investigate its performance in dose reduction for various phantoms and image variance targets. METHODS: The proposed method uses Monte Carlo simulations of a proton CT (pCT) prototype scanner to estimate expected variance levels at uniform fluence. Using an iterative approach, we calculate a stack of target variance projections that are required to achieve the prescribed image variance, assuming a reconstruction using filtered backprojection. By fitting a pencil beam model to the ratio of uniform fluence variance and target variance, relative weights for each pencil beam can be calculated. The quality of the resulting fluence modulations is evaluated by scoring imaging doses and comparing them to those at uniform fluence, as well as evaluating conformity of the achieved variance with the prescription. For three different phantoms, we prescribed constant image variance as well as two regions-of-interest (ROI) imaging tasks with inhomogeneous image variance. The shape of the ROIs followed typical beam profiles for proton therapy. RESULTS: Prescription of constant image variance resulted in a dose reduction of 8.9% for a homogeneous water phantom compared to a uniform fluence scan at equal peak variance level. For a more heterogeneous head phantom, dose reduction increased to 16.0% for the same task. Prescribing two different ROIs resulted in dose reductions between 25.7% and 40.5% outside of the ROI at equal peak variance levels inside the ROI. Imaging doses inside the ROI were increased by 9.2% to 19.2% compared to the uniform fluence scan, but can be neglected assuming that the ROI agrees with the therapeutic dose region. Agreement of resulting variance maps with the prescriptions was satisfactory. CONCLUSIONS: We developed a method for fluence field optimization based on a noise model for a real scanner used in pCT. We demonstrated that it can achieve prescribed image variance targets. A uniform fluence field was shown not to be dose optimal and dose reductions achievable with the proposed method for FMpCT were considerable, opening an interesting perspective for image guidance and adaptive therapy.


Asunto(s)
Algoritmos , Protones , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Procesamiento de Imagen Asistido por Computador , Método de Montecarlo , Fantasmas de Imagen
4.
Phys Med Biol ; 64(14): 145016, 2019 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-31125986

RESUMEN

We present a method to accurately predict image noise in proton computed tomography (pCT) using data generated from a Monte Carlo simulation and a patient or object model that may be generated from a prior x-ray CT image. This enables noise prediction for arbitrary beam fluence settings and, therefore, the application of fluence-modulated pCT (FMpCT), which can achieve prescribed noise targets and may significantly reduce the integral patient dose. We extended an existing Monte Carlo simulation of a prototype pCT scanner to include effects of quenching in the energy detector scintillators and constructed a beam model from experimental tracking data. Simulated noise predictions were compared to experimental data both in the projection domain and in the reconstructed image. Noise prediction agreement between simulated and experimental data in terms of the root-mean-square (RMS) error was better than 7% for a homogeneous water phantom and a sensitometry phantom with tubular inserts. For an anthropomorphic head phantom, modeling the anatomy of a five-year-old child, the RMS error was better than 9% in three evaluated slices. We were able to reproduce subtle noise features near heterogeneities. To demonstrate the feasibility of Monte Carlo simulated noise maps for fluence modulation, we calculated a fluence profile that yields a homogeneous noise level in the image. Unlike for bow-tie filters in x-ray CT this does not require constant fluence at the detector and the shape of the fluence profile is fundamentally different. Using an improved Monte Carlo simulation, we demonstrated the feasibility of using simulated data for accurate image noise prediction for pCT. We believe that the agreement with experimental data is sufficient to enable the future optimization of FMpCT fluence plans to achieve prescribed noise targets in a fluence-modulated acquisition.


Asunto(s)
Cabeza/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Protones , Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Humanos , Método de Montecarlo , Dosis de Radiación , Relación Señal-Ruido
5.
J Infect Dis ; 218(8): 1272-1283, 2018 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-29401315

RESUMEN

To identify the mechanisms by which human immunodeficiency virus type 1 (HIV-1) might penetrate the epithelial barrier during sexual transmission to women and the mechanisms of vaccine-associated protection against entry, we characterized early epithelial responses to vaginal inoculation of simian immunodeficiency virus strain mac251 (SIVmac251) in naive or SIVmac239Δnef-vaccinated rhesus macaques. Vaginal inoculation induced an early stress response in the cervicovaginal epithelium, which was associated with impaired epithelial integrity, damaged barrier function, and virus and bacterial translocation. In vaccinated animals, early stress responses were suppressed, and the maintenance of epithelial barrier integrity correlated with prevention of virus entry. These vaccine-protective effects were associated with a previously described mucosal system for locally producing and concentrating trimeric gp41 antibodies at the mucosal interface and with formation of SIV-specific immune complexes that block the stress responses via binding to the epithelial receptor FCGR2B and subsequent inhibitory signaling. Thus, blocking virus entry may be one protective mechanism by which locally concentrated non-neutralizing Ab might prevent HIV sexual transmission to women.


Asunto(s)
Síndrome de Inmunodeficiencia Adquirida del Simio/prevención & control , Virus de la Inmunodeficiencia de los Simios/inmunología , Vacunas Virales/administración & dosificación , Vacunas Virales/inmunología , Internalización del Virus , Administración Intravaginal , Animales , Epitelio/fisiología , Epitelio/virología , Femenino , Macaca mulatta , Síndrome de Inmunodeficiencia Adquirida del Simio/virología , Estrés Fisiológico , Vacunación , Vagina/fisiología , Vagina/virología
6.
Mucosal Immunol ; 11(2): 512-522, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28792003

RESUMEN

Cervicovaginal epithelium plays a critical role in determining the outcome of virus transmission in the female reproductive tract (FRT) by initiating or suppressing transmission-facilitating mucosal immune responses in naïve and SIVmac239Δnef-vaccinated animals, respectively. In this study, we examined the very early responses of cervical epithelium within 24 h after vaginal exposure to SIV in naive and SIVmac239Δnef-vaccinated rhesus macaques. Using both ex vivo and in vivo experimental systems, we found that vaginal exposure to SIV rapidly induces a broad spectrum of pro-inflammatory responses in the epithelium associated with a reciprocal regulation of NF-kB and glucocorticoid receptor (GR) signaling pathways. Conversely, maintenance of high-level GR expression and suppression of NF-kB expression in the epithelium were associated with an immunologically quiescent state in the FRT mucosa and protection against vaginal challenge in SIVmac239Δnef-vaccinated animals. We show that the immunologically quiescent state is induced by FCGR2B-immune complexes interactions that modify the reciprocal regulation of NF-kB and GR signaling pathways. Our results suggest that targeting the balance of NF-kB and GR signaling in early cervicovaginal epithelium responses could moderate mucosal inflammation and target cell availability after vaginal infection, thereby providing a complementary approach to current prevention strategies.


Asunto(s)
Vacunas contra el SIDA/inmunología , Cuello del Útero/patología , Células Epiteliales/fisiología , Infecciones por VIH/inmunología , VIH-1/fisiología , Inflamación/inmunología , FN-kappa B/metabolismo , Receptores de Glucocorticoides/metabolismo , Vacunas contra el SIDAS/inmunología , Síndrome de Inmunodeficiencia Adquirida del Simio/inmunología , Virus de la Inmunodeficiencia de los Simios/fisiología , Vagina/patología , Vacunas Virales/inmunología , Animales , Anticuerpos Antivirales/metabolismo , Ácido Aspártico Endopeptidasas/genética , Transmisión de Enfermedad Infecciosa , Células Epiteliales/virología , Femenino , Inmunidad Mucosa , Inflamación/virología , Macaca mulatta , Vacunas contra el SIDAS/genética , Transducción de Señal , Vacunación
7.
Can Commun Dis Rep ; 44(11): 304-307, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30996693

RESUMEN

Shiga toxin-producing Escherichia coli (STEC) are important enteric pathogens responsible for sporadic cases and outbreaks of gastroenteritis. E.coli O157:H7/NM (STEC O157) are the most commonly known STEC serotypes but it is now increasingly apparent that non-O157 STEC serotypes have been underreported in the past because they were not part of routine screening in many front-line laboratories. The Canadian Public Health Laboratory Network (CPHLN) has identified the need for improved detection and surveillance of non-O157 STEC and has developed the following recommendations to assist in the decision-making process for clinical and reference microbiology laboratories. These recommendations should be followed to the best of a laboratory's abilities based on the availability of technology and resources. The CPHLN recommends that when screening for the agents of bacterial gastroenteritis from a stool sample, front-line laboratories use either a chromogenic agar culture or a culture-independent diagnostic test (CIDT). CIDT options include nucleic acid amplification tests (NAATs) to detect Shiga toxin genes or enzyme immunoassays (EIAs) to detect Shiga toxins. If either CIDT method is positive for possible STEC, laboratories must have a mechanism to culture and isolate STEC in order to support both provincial and national surveillance as well as outbreak investigations and response. These CPHLN recommendations should result in improved detection of STEC in patients presenting with diarrhea, especially when due to the non-O157 serotypes. These measures should enhance the overall quality of healthcare and food safety, and provide better protection of the public via improved surveillance and outbreak detection and response.

8.
Phys Med Biol ; 62(15): 6026-6043, 2017 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-28582265

RESUMEN

This simulation study presents the application of fluence field modulated computed tomography, initially developed for x-ray CT, to proton computed tomography (pCT). By using pencil beam (PB) scanning, fluence modulated pCT (FMpCT) may achieve variable image quality in a pCT image and imaging dose reduction. Three virtual phantoms, a uniform cylinder and two patients, were studied using Monte Carlo simulations of an ideal list-mode pCT scanner. Regions of interest (ROI) were selected for high image quality and only PBs intercepting them preserved full fluence (FF). Image quality was investigated in terms of accuracy (mean) and noise (standard deviation) of the reconstructed proton relative stopping power compared to reference values. Dose calculation accuracy on FMpCT images was evaluated in terms of dose volume histograms (DVH), range difference (RD) for beam-eye-view (BEV) dose profiles and gamma evaluation. Pseudo FMpCT scans were created from broad beam experimental data acquired with a list-mode pCT prototype. FMpCT noise in ROIs was equivalent to FF images and accuracy better than -1.3%(-0.7%) by using 1% of FF for the cylinder (patients). Integral imaging dose reduction of 37% and 56% was achieved for the two patients for that level of modulation. Corresponding DVHs from proton dose calculation on FMpCT images agreed to those from reference images and 96% of BEV profiles had RD below 2 mm, compared to only 1% for uniform 1% of FF. Gamma pass rates (2%, 2 mm) were 98% for FMpCT while for uniform 1% of FF they were as low as 59%. Applying FMpCT to preliminary experimental data showed that low noise levels and accuracy could be preserved in a ROI, down to 30% modulation. We have shown, using both virtual and experimental pCT scans, that FMpCT is potentially feasible and may allow a means of imaging dose reduction for a pCT scanner operating in PB scanning mode. This may be of particular importance to proton therapy given the low integral dose found outside the target.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Terapia de Protones/métodos , Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X/instrumentación , Humanos , Método de Montecarlo , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos
9.
Phys Rev Lett ; 118(19): 195501, 2017 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-28548523

RESUMEN

Computational modeling and experimental measurements on metal samples subject to a laser-driven, ablative Richtmyer-Meshkov instability showed differences between viscosity and strength effects. In particular, numerical and analytical solutions, coupled with measurements of fed-through perturbations, generated by perturbed shock fronts onto initially flat surfaces, show promise as a validation method for models of deviatoric response in the postshocked material. Analysis shows that measurements of shock perturbation amplitudes at low sample thickness-to-wavelength ratios are not enough to differentiate between strength and viscosity effects, but that surface displacement data of the fed-through perturbations appears to resolve the ambiguity. Additionally, analytical and numerical results show shock front perturbation evolution dependence on initial perturbation amplitude and wavelength is significantly different in viscous and materials with strength, suggesting simple experimental geometry changes should provide data supporting one model or the other.

10.
Mucosal Immunol ; 10(2): 508-519, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27435105

RESUMEN

In the SIV (simian immunodeficiency virus)-rhesus macaque model of HIV-1 (human immunodeficiency virus type I) transmission to women, one hallmark of the mucosal response to exposure to high doses of SIV is CD4 T-cell recruitment that fuels local virus expansion in early infection. In this study, we systematically analyzed the cellular events and chemoattractant profiles in cervical tissues that precede CD4 T-cell recruitment. We show that vaginal exposure to the SIV inoculum rapidly induces chemokine expression in cervical epithelium including CCL3, CCL20, and CXCL8. The chemokine expression is associated with early recruitment of macrophages and plasmacytoid dendritic cells that are co-clustered underneath the cervical epithelium. Production of chemokines CCL3 and CXCL8 by these cells in turn generates a chemokine gradient that is spatially correlated with the recruitment of CD4 T cells. We further show that the protection of SIVmac239Δnef vaccination against vaginal challenge is correlated with the absence of this epithelium-innate immune cell-CD4 T-cell axis response in the cervical mucosa. Our results reveal a critical role for cervical epithelium in initiating early mucosal responses to vaginal infection, highlight an important role for macrophages in target cell recruitment, and provide further evidence of a paradoxical dampening effect of a protective vaccine on these early mucosal responses.


Asunto(s)
Linfocitos T CD4-Positivos/inmunología , Células Dendríticas/inmunología , Epitelio/inmunología , Infecciones por VIH/inmunología , VIH-1/inmunología , Macrófagos/inmunología , Vacunas contra el SIDAS/inmunología , Síndrome de Inmunodeficiencia Adquirida del Simio/inmunología , Virus de la Inmunodeficiencia de los Simios/inmunología , Vagina/inmunología , Animales , Linfocitos T CD4-Positivos/virología , Movimiento Celular , Quimiocina CCL20/genética , Quimiocina CCL20/metabolismo , Quimiocina CCL3/genética , Quimiocina CCL3/metabolismo , Epitelio/virología , Femenino , Humanos , Inmunidad Mucosa , Interleucina-8/genética , Interleucina-8/metabolismo , Macaca mulatta , Macrófagos/virología , Vacunación
11.
Med Phys ; 43(12): 6291, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27908179

RESUMEN

PURPOSE: To evaluate the spatial resolution of proton CT using both a prototype proton CT scanner and Monte Carlo simulations. METHODS: A custom cylindrical edge phantom containing twelve tissue-equivalent inserts with four different compositions at varying radial displacements from the axis of rotation was developed for measuring the modulation transfer function (MTF) of a prototype proton CT scanner. Two scans of the phantom, centered on the axis of rotation, were obtained with a 200 MeV, low-intensity proton beam: one scan with steps of 4°, and one scan with the phantom continuously rotating. In addition, Monte Carlo simulations of the phantom scan were performed using scanners idealized to various degrees. The data were reconstructed using an iterative projection method with added total variation superiorization based on individual proton histories. Edge spread functions in the radial and azimuthal directions were obtained using the oversampling technique. These were then used to obtain the modulation transfer functions. The spatial resolution was defined by the 10% value of the modulation transfer function (MTF10%) in units of line pairs per centimeter (lp/cm). Data from the simulations were used to better understand the contributions of multiple Coulomb scattering in the phantom and the scanner hardware, as well as the effect of discretization of proton location. RESULTS: The radial spatial resolution of the prototype proton CT scanner depends on the total path length, W, of the proton in the phantom, whereas the azimuthal spatial resolution depends both on W and the position, u-, at which the most-likely path uncertainty is evaluated along the path. For protons contributing to radial spatial resolution, W varies with the radial position of the edge, whereas for protons contributing to azimuthal spatial resolution, W is approximately constant. For a pixel size of 0.625 mm, the radial spatial resolution of the image reconstructed from the fully idealized simulation data ranged between 6.31 ± 0.36 lp/cm for W = 197 mm i.e., close to the center of the phantom, and 13.79 ± 0.36 lp/cm for W = 97 mm, near the periphery of the phantom. The azimuthal spatial resolution ranged from 6.99 ± 0.23 lp/cm at u- = 75 mm (near the center) to 11.20 ± 0.26 lp/cm at u- = 20 mm (near the periphery). Multiple Coulomb scattering limits the radial spatial resolution for path lengths greater than approximately 130 mm, and the azimuthal spatial resolution for positions of evaluation greater than approximately 40 mm for W = 199 mm. The radial spatial resolution of the image reconstructed from data from the 4° stepped experimental scan ranged from 5.11 ± 0.61 lp/cm for W = 197 mm to 8.58 ± 0.50 lp/cm for W = 97 mm. In the azimuthal direction, the spatial resolution ranged from 5.37 ± 0.40 lp/cm at u- = 75 mm to 7.27 ± 0.39 lp/cm at u- = 20 mm. The continuous scan achieved the same spatial resolution as that of the stepped scan. CONCLUSIONS: Multiple Coulomb scattering in the phantom is the limiting physical factor of the achievable spatial resolution of proton CT; additional loss of spatial resolution in the prototype system is associated with scattering in the proton tracking system and inadequacies of the proton path estimate used in the iterative reconstruction algorithm. Improvement in spatial resolution may be achievable by improving the most likely path estimate by incorporating information about high and low density materials, and by minimizing multiple Coulomb scattering in the proton tracking system.


Asunto(s)
Protones , Relación Señal-Ruido , Tomógrafos Computarizados por Rayos X , Método de Montecarlo , Fantasmas de Imagen
12.
Nucl Instrum Methods Phys Res A ; 831: 394-399, 2016 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-27818559

RESUMEN

We report on the operation and performance tests of a preclinical head scanner developed for proton computed tomography (pCT). After extensive preclinical testing, pCT is intended to be employed in support of proton therapy treatment planning and pre-treatment verification in patients undergoing particle-beam therapy. In order to assess the performance of the scanner, we have performed CT scans with 200 MeV protons from both the synchrotron of the Loma Linda University Medical Center (LLUMC) and the cyclotron of the Northwestern Medicine Chicago Proton Center (NMCPC). The very high sustained rate of data acquisition, exceeding one million protons per second, allowed a full 360° scan to be completed in less than 7 minutes. The reconstruction of various phantoms verified accurate reconstruction of the proton relative stopping power (RSP) and the spatial resolution in a variety of materials. The dose for an image with better than 1% uncertainty in the RSP is found to be close to 1 mGy.

13.
Med Phys ; 43(2): 664-74, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26843230

RESUMEN

PURPOSE: Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to evaluate the water-equivalent path length (WEPL) of a proton passing through the object. A novel approach is presented for an inexpensive WEPL detector for pCT and proton radiography. METHODS: A novel multistage detector with an aperture of 10 × 37.5 cm was designed to optimize the accuracy of the WEPL measurements while simplifying detector construction and the performance requirements of its components. The design of the five-stage detector was optimized through simulations based on the geant4 detector simulation toolkit, and the fabricated prototype was calibrated in water-equivalent millimeters with 200 MeV protons in the research beam line of the clinical proton synchrotron at Loma Linda University Medical Center. A special polystyrene step phantom was designed and built to speed up and simplify the calibration procedure. The calibrated five-stage detector was tested in the 200 MeV proton beam as part of the pCT head scanner, using a water phantom and polystyrene slabs to verify the WEPL reconstruction accuracy. RESULTS: The beam-test results demonstrated excellent performance of the new detector, in good agreement with the simulation results. The WEPL measurement accuracy is about 3.0 mm per proton in the 0-260 mm WEPL range required for a pCT head scan with a 200 MeV proton beam. CONCLUSIONS: The new multistage design approach to WEPL measurements for proton CT and radiography has been prototyped and tested. The test results show that the design is competitive with much more expensive calorimeter and range-counter designs.


Asunto(s)
Protones , Conteo por Cintilación/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Calibración , Diseño de Equipo , Incertidumbre
14.
Food Microbiol ; 51: 69-73, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26187829

RESUMEN

Efficacy of four bacteriophages (phages) and a cocktail for biocontrol of Escherichia coli O157 was assessed on beef samples stored at 4, 22 and 37 °C. Samples (3 × 3 × 1 cm) were contaminated with E. coli O157 (10(4) CFU/cm(2)) and treated with single phages: T5-like (T5), T1-like (T1), T4-like (T4) and O1-like (O1), or a cocktail at two titers: multiplicity of infection (MOI) = 1000 and MOI = 10. In contrast to previous studies, use of virucidal solution prevented over-estimation of phage efficacy. Irrespective of temperature and MOIs, T5 was most (P < 0.001) and O1 least (P < 0.05) effective for biocontrol of E. coli O157, with relative efficacy of other phages temperature dependent. At 4 °C, T1 (P < 0.05) and cocktail (P < 0.001) were more effective than T4. In contrast, T4 was equally (P = 0.08, at 37 °C) or less effective (P = 0.003, at 22 °C) than T5. Phages were more effective (P < 0.001) against E. coli O157 at warmer temperatures and high MOI. As the beef supply chain includes hours of storage or transport at temperatures near 4 °C, this study demonstrates phages could significantly reduce E. coli O157 during this period.


Asunto(s)
Colifagos/fisiología , Escherichia coli O157/fisiología , Carne Roja/microbiología , Carne Roja/virología , Temperatura , Animales , Bacteriófago T4/fisiología , Agentes de Control Biológico , Bovinos , Infecciones por Escherichia coli/prevención & control , Escherichia coli O157/crecimiento & desarrollo , Microbiología de Alimentos , Viabilidad Microbiana
15.
IEEE Trans Med Imaging ; 33(4): 875-81, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24710156

RESUMEN

Proton radiography has applications in patient alignment and verification procedures for proton beam radiation therapy. In this paper, we report an experiment which used 200 MeV protons to generate proton energy-loss and scattering radiographs of a hand phantom. The experiment used the first-generation proton computed tomography (CT) scanner prototype, which was installed on the research beam line of the clinical proton synchrotron at Loma Linda University Medical Center. It was found that while both radiographs displayed anatomical details of the hand phantom, the energy-loss radiograph had a noticeably higher resolution. Nonetheless, scattering radiography may yield more contrast between soft and bone tissue than energy-loss radiography, however, this requires further study. This study contributes to the optimization of the performance of the next-generation of clinical proton CT scanners. Furthermore, it demonstrates the potential of proton imaging (proton radiography and CT), which is now within reach of becoming available as a new, potentially low-dose medical imaging modality.


Asunto(s)
Mano/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Protones , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/instrumentación
16.
Appl Environ Microbiol ; 80(13): 3819-25, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24747892

RESUMEN

The objectives of this study were to identify endemic bacteriophages (phages) in the feedlot environment and determine relationships of these phages to Escherichia coli O157:H7 from cattle shedding high and low numbers of naturally occurring E. coli O157:H7. Angus crossbred steers were purchased from a southern Alberta (Canada) feedlot where cattle excreting ≥ 10(4) CFU · g(-1) of E. coli O157:H7 in feces at a single time point were identified as supershedders (SS; n = 6), and cattle excreting <10(4) CFU · g(-1) of feces were identified as low shedders (LS; n = 5). Fecal pats or fecal grabs were collected daily from individual cattle for 5 weeks. E. coli O157:H7 in feces was detected by immunomagnetic separation and enumerated by direct plating, and phages were isolated using short- and overnight-enrichment methods. The total prevalence of E. coli O157:H7 isolated from feces was 14.4% and did not differ between LS and SS (P = 0.972). The total prevalence of phages was higher in the LS group (20.9%) than in the SS group (8.3%; P = 0.01). Based on genome size estimated by pulsed-field gel electrophoresis and morphology determined by transmission electron microscopy, T4- and O1-like phages of Myoviridae and T1-like phage of Siphoviridae were isolated. Compared to T1- and O1-like phages, T4-like phages exhibited a broad host range and strong lytic capability when targeting E. coli O157:H7. Moreover, the T4-like phages were more frequently isolated from feces of LS than SS, suggesting that endemic phages may impact the shedding dynamics of E. coli O157:H7 in cattle.


Asunto(s)
Carga Bacteriana , Derrame de Bacterias , Colifagos/clasificación , Colifagos/aislamiento & purificación , Infecciones por Escherichia coli/veterinaria , Escherichia coli O157/virología , Heces/microbiología , Alberta , Animales , Bovinos , Colifagos/ultraestructura , ADN Viral/genética , Electroforesis en Gel de Campo Pulsado , Infecciones por Escherichia coli/microbiología , Escherichia coli O157/aislamiento & purificación , Microscopía Electrónica de Transmisión , Myoviridae/clasificación , Myoviridae/aislamiento & purificación , Myoviridae/ultraestructura , Siphoviridae/clasificación , Siphoviridae/aislamiento & purificación , Siphoviridae/ultraestructura , Virión/ultraestructura
17.
Rev Sci Instrum ; 85(2): 02B111, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593551

RESUMEN

Extraction of negative ions from a saddle antenna radio-frequency surface plasma source is considered. Several versions of new plasma generators with different antennas and magnetic field configurations were tested in the smal Oak Ridge National Laboratory Spallation Neutron Source Test Stand. The efficiency of positive ion generation in plasma has been improved to 200 mA/cm(2) kW from 2.5 mA/cm(2) kW. A small oven was developed for cesiation by cesium compounds and alloy decomposition. After cesiation, a current of negative ions to the collector was increased from 1 mA to 10 mA with 1.5 kW RF power in the plasma and longitudinal magnetic field Bl ∼ 250 G. The specific efficiency of H(-) production was increased to 20 mA/cm(2) kW from 2.5 mA/cm(2) kW.

18.
Appl Environ Microbiol ; 80(7): 2166-75, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24487525

RESUMEN

Verotoxin-producing Escherichia coli (VTEC) strains are the cause of food-borne and waterborne illnesses around the world. Traditionally, surveillance of the human population as well as the environment has focused on the detection of E. coli O157:H7. Recently, increasing recognition of non-O157 VTEC strains as human pathogens and the German O104:H4 food-borne outbreak have illustrated the importance of considering the broader group of VTEC organisms from a public health perspective. This study presents the results of a comparison of three methods for the detection of VTEC in surface water, highlighting the efficacy of a direct VT immunoblotting method without broth enrichment for detection and isolation of O157 and non-O157 VTEC strains. The direct immunoblot method eliminates the need for an enrichment step or the use of immunomagnetic separation. This method was developed after 4 years of detecting low frequencies (1%) of E. coli O157:H7 in surface water in a Canadian watershed, situated within one of the FoodNet Canada integrated surveillance sites. By the direct immunoblot method, VTEC prevalence estimates ranged from 11 to 35% for this watershed, and E. coli O157:H7 prevalence increased to 4% (due to improved method sensitivity). This direct testing method provides an efficient means to enhance our understanding of the prevalence and types of VTEC in the environment. This study employed a rapid evidence assessment (REA) approach to frame the watershed findings with watershed E. coli O157:H7 prevalences reported in the literature since 1990 and the knowledge gap with respect to VTEC detection in surface waters.


Asunto(s)
Escherichia coli Shiga-Toxigénica/aislamiento & purificación , Microbiología del Agua , Técnicas Bacteriológicas/métodos , Canadá , Escherichia coli O157/aislamiento & purificación , Humanos , Immunoblotting/métodos , Prevalencia , Prohibitinas , Escherichia coli Shiga-Toxigénica/clasificación
19.
Phys Rev Lett ; 111(18): 184802, 2013 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-24237526

RESUMEN

A major technological challenge in building a muon cooling channel is operating rf cavities in multitesla external magnetic fields. We report the first proof-of-principle experiment of a high pressure gas-filled rf cavity for use with intense ionizing beams and strong external magnetic fields. rf power consumption by beam-induced plasma is investigated with hydrogen and deuterium gases with pressures between 20 and 100 atm and peak rf gradients between 5 and 50 MV/m. The low pressure case agrees well with an analytical model based on electron and ion mobilities. Varying concentrations of oxygen gas are investigated to remove free electrons from the cavity and reduce the rf power consumption. Measurements of the electron attachment time to oxygen and rate of ion-ion recombination are also made. Additionally, we demonstrate the operation of the gas-filled rf cavity in a solenoidal field of up to 3 T, finding no major magnetic field dependence. All these results indicate that a high pressure gas-filled cavity is a viable technology for muon ionization cooling.

20.
Nucl Instrum Methods Phys Res A ; 699: 205-210, 2013 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-23264711

RESUMEN

We describe a new head scanner developed for Proton Computed Tomography (pCT) in support of proton therapy treatment planning, aiming at reconstructing an accurate map of the stopping power (S.P.) in a phantom and, in the future, in patients. The system consists of two silicon telescopes which track the proton before and after the phantom/patient, and an energy detector which measures the residual energy or range of the proton to reconstruct the Water Equivalent Path Length (WEPL) in the phantom. Based on the experience of the existing prototype and extensive Geant4 simulations and CT reconstructions, the new pCT scanner will support clinically useful proton fluxes.

SELECCIÓN DE REFERENCIAS