Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
J Diabetes Sci Technol ; 17(3): 649-655, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37081831

RESUMEN

BACKGROUND: The COVID-19 pandemic necessitated rapid implementation of continuous glucose monitoring (CGM) in the intensive care unit (ICU). Although rarely reported, perceptions from nursing staff who used the systems are critical for successful implementation and future expanded use of CGM in the inpatient setting. METHODS: A 22-item survey focused on CGM use was distributed to ICU nurses at two large academic medical centers in the United States in 2022. Both institutions initiated inpatient CGM in the spring of 2020 using the same CGM+point of care (POC) hybrid protocol. The survey employed a 1- to 5-point Likert scale regarding CGM sensor insertion, accuracy, acceptability, usability, training, and perceptions on workload. RESULTS: Of the 71 surveys completed, 68 (96%) nurses reported they cared for an ICU patient on CGM and 53% reported they had independently performed CGM sensor insertion. The ICU nurses overwhelmingly reported that CGM was accurate, reduced their workload, provided safer patient care, and was preferred over POC glucose testing alone. Interestingly, nearly half of nurses (49%) reported that they considered trend arrows in dosing decisions although trends were not included in the CGM+POC hybrid protocol. Nurses received training through multiple modalities, with the majority (80%) of nurses reporting that CGM training was sufficient and prepared them for its use. CONCLUSION: These results confirm nursing acceptance and preference for CGM use within a hybrid glucose monitoring protocol in the ICU setting. These data lay a blueprint for successful implementation and training strategies for future widespread use.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , COVID-19 , Humanos , Automonitorización de la Glucosa Sanguínea/métodos , Glucemia , Pandemias , Unidades de Cuidados Intensivos
2.
J Pharm Pract ; 35(3): 347-351, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33267711

RESUMEN

BACKGROUND: Central venous catheters (CVC) are generally recommended for norepinephrine administration due to risk of tissue ischemia. Early resuscitation, leading to decreased infusion duration, may minimize the need for CVCs if norepinephrine can be administered safely through a peripheral intravenous catheter (PIV). OBJECTIVE: A protocol was developed for peripheral administration. Safety, CVC placement, and adherence with protocol elements were evaluated. METHODS: A single-center, prospective, observational pilot was conducted for patients receiving norepinephrine in the Medical Intensive Care Unit (MICU). Patients were considered for PIV administration of low dose norepinephrine for less than 24 hours based on clinical status and anticipated short-term use. Protocolized interventions for PIV's included criteria for gauge, number, and site as well as visual inspection and evaluation every 2 hours. Data was collected on protocol elements to evaluate safety and effectiveness of the protocol. RESULTS: There were 316 occurrences of norepinephrine infusions including 92 via PIV (patients may have received multiple treatments). 34% (31/92) did not require a CVC. 3 had infiltrated PIV's without tissue injury. Maximum dose adherence was 73%. 97% of infusions ran less than 24 hours. Nursing adherence included: 91% gauge, 65% proper site, 99% adequate number, 49% blood return on initiation, 55% ongoing blood return, and 61% IV site checked. CONCLUSION: Our results suggest that norepinephrine is safe to administer through a PIV at low doses for less than 24 hours using a protocol. Prevention of unnecessary CVC insertion is beneficial by minimizing the risk of central line complications thus improving patient morbidity.


Asunto(s)
Cateterismo Periférico , Catéteres Venosos Centrales , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/métodos , Catéteres Venosos Centrales/efectos adversos , Humanos , Infusiones Intravenosas , Norepinefrina/efectos adversos , Estudios Prospectivos
3.
J Clin Endocrinol Metab ; 106(10): e4007-e4016, 2021 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-34100545

RESUMEN

CONTEXT: The coronavirus disease 2019 (COVID-19) pandemic has created a need for remote blood glucose (BG) monitoring in the intensive care unit (ICU). OBJECTIVE: To evaluate feasibility and patient safety of a hybrid monitoring strategy of point-of-care (POC) BG plus continuous glucose monitor (CGM) in the ICU. DESIGN: Retrospective analysis. SETTING: ICU of an academic medical center. PATIENTS: Patients with COVID-19 on IV insulin. INTERVENTION: After meeting initial validation criteria, CGM was used for IV insulin titration and POC BG was performed every 6 hours or as needed. MAIN OUTCOME MEASURES: Outcomes included frequency of POC BG, workflow, safety, and accuracy measures. RESULTS: The study included 19 patients, 18 with CGM data, mean age 58 years, 89% on mechanical ventilation, 37% on vasopressors, and 42% on dialysis. The median time to CGM validation was 137 minutes (interquartile range [IQR] 114-206). During IV insulin, the median number of POC values was 7 (IQR 6-16) on day 1, and declined slightly thereafter (71% reduction compared with standard of 24/day). The median number of CGM values used nonadjunctively to titrate IV insulin was 11.5 (IQR 0, 15) on day 1 and increased thereafter. Time in range 70 to 180 mg/dL was 64 ± 23% on day 1 and 72 ± 16% on days 2 through 7, whereas time <70 mg/dL was 1.5 ± 4.1% on day 1 and <1% on days 2 through 7. CONCLUSIONS: This study provides data to support that CGM using a hybrid protocol is feasible, accurate, safe, and has potential to reduce nursing and staff workload.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/métodos , COVID-19/epidemiología , Diabetes Mellitus/epidemiología , Diabetes Mellitus/terapia , Insulina/administración & dosificación , SARS-CoV-2 , Adulto , Anciano , Glucemia/análisis , COVID-19/terapia , Comorbilidad , Enfermedad Crítica/terapia , Complicaciones de la Diabetes/epidemiología , Complicaciones de la Diabetes/terapia , Complicaciones de la Diabetes/virología , Femenino , Control Glucémico/métodos , Humanos , Infusiones Intravenosas , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Sistemas de Atención de Punto , Estudios Retrospectivos , Resultado del Tratamiento
4.
Endocr Pract ; 27(4): 354-361, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33515756

RESUMEN

OBJECTIVE: We describe our implementation of a continuous glucose monitoring (CGM) guideline to support intravenous insulin administration and reduce point of care (POC) glucose monitoring frequency in the coronavirus disease 2019 medical intensive care unit (MICU) and evaluate nurses' experience with implementation of CGM and hybrid POC + CGM protocol using the Promoting Action on Research in Health Services framework. METHODS: A multidisciplinary team created a guideline providing criteria for establishing initial sensor-meter agreement within each individual patient followed by hybrid use of CGM and POC. POC measures were obtained hourly during initial validation, then every 6 hours. We conducted a focus group among MICU nurses to evaluate initial implementation efforts with content areas focused on initial assessment of evidence, context, and facilitation to identify barriers and facilitators. The focus group was analyzed using a qualitative descriptive approach. RESULTS: The protocol was integrated through a rapid cycle review process and ultimately disseminated nationally. The Diabetes Consult Service performed device set-up and nurses received just-in-time training. The majority of barriers centered on contextual factors, including limitations of the physical environment, complex device set-up, hospital firewalls, need for training, and CGM documentation. Nurses' perceived device accuracy and utility were exceptionally high. Solutions were devised to maximize facilitation and sustainability for nurses while maintaining patient safety. CONCLUSION: Outpatient CGM systems can be implemented in the MICU using a hybrid protocol implementation science approach. These efforts hold tremendous potential to reduce healthcare worker exposure while maintaining glucose control during the COVID-19 pandemic.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , COVID-19 , Glucemia , Enfermedad Crítica , Humanos , Pandemias , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA