Crit Care Explor ; 6(5): e1089, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38728059

RESUMEN

IMPORTANCE: Patients admitted with cerebral hemorrhage or cerebral edema often undergo external ventricular drain (EVD) placement to monitor and manage intracranial pressure (ICP). A strain gauge transducer accompanies the EVD to convert a pressure signal to an electrical waveform and assign a numeric value to the ICP. OBJECTIVES: This study explored ICP accuracy in the presence of blood and other viscous fluid contaminates in the transducer. DESIGN: Preclinical comparative design study. SETTING: Laboratory setting using two Natus EVDs, two strain gauge transducers, and a sealed pressure chamber. PARTICIPANTS: No human subjects or animal models were used. INTERVENTIONS: A control transducer primed with saline was compared with an investigational transducer primed with blood or with saline/glycerol mixtures in mass:mass ratios of 25%, 50%, 75%, and 100% glycerol. Volume in a sealed chamber was manipulated to reflect changes in ICP to explore the impact of contaminates on pressure measurement. MEASUREMENTS AND MAIN RESULTS: From 90 paired observations, ICP readings were statistically significantly different between the control (saline) and experimental (glycerol or blood) transducers. The time to a stable pressure reading was significantly different for saline vs. 25% glycerol (< 0.0005), 50% glycerol (< 0.005), 75% glycerol (< 0.0001), 100% glycerol (< 0.0005), and blood (< 0.0005). A difference in resting stable pressure was observed for saline vs. blood primed transducers (0.041). CONCLUSIONS AND RELEVANCE: There are statistically significant and clinically relevant differences in time to a stable pressure reading when contaminates are introduced into a closed drainage system. Changing a transducer based on the presence of blood contaminate should be considered to improve accuracy but must be weighed against the risk of introducing infection.


Asunto(s)
Presión Intracraneal , Transductores de Presión , Presión Intracraneal/fisiología , Humanos , Sangre/metabolismo , Glicerol , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Drenaje/instrumentación , Hemorragia Cerebral/fisiopatología , Hemorragia Cerebral/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...