Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
3.
World J Pediatr Congenit Heart Surg ; 13(2): 166-174, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35238706

RESUMEN

BACKGROUND: Neo-aortic pulmonary autografts often experience root dilation and valve regurgitation over time. This study seeks to understand the biomechanical differences between aortic and neo-aortic pulmonary roots using a heart simulator. METHODS: Porcine aortic, neo-aortic pulmonary, and pulmonary roots (n = 6) were mounted in a heart simulator (parameters: 100 mm Hg, 37 °C, 70 cycles per minute, 5.0 L/min cardiac output). Echocardiography was used to study root distensibility (percentage change in luminal diameter between systole and diastole) and valve function. Leaflet motion was tracked with high-speed videography. After 30 min in the simulator, leaflet thickness (via cryosectioning), and multiaxial modulus (via lenticular hydrostatic deformation testing) were obtained. RESULTS: There were no significant differences between aortic and neo-aortic pulmonary leaflet motion, including mean opening velocity (218 vs 248 mm/s, P = .27) or mean closing velocity (116 vs 157 mm/s, P = .12). Distensibility was similar between aortic (8.5%, 1.56 mm) and neo-aortic pulmonary (7.8%, 1.12 mm) roots (P = .59). Compared to virgin controls, native pulmonic roots exposed to systemic pressure for 30 min had reduced leaflet thickness (630 vs 385 µm, P = .049) and a reduced Young's modulus (3,125 vs 1,089 kPa, P = .077). In contrast, the aortic roots exposed to pressure displayed no significant difference in aortic leaflet thickness (1,317 vs 1,256 µm, P = .27) or modulus (5,931 vs 3,631 kPa, P = .56). CONCLUSIONS: Neo-aortic pulmonary roots demonstrated equivalence in valve function and distensibility but did experience changes in biomechanical properties and morphology. These changes may contribute to long-term complications associated with the Ross procedure.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Válvula Pulmonar , Animales , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Autoinjertos , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Válvula Pulmonar/trasplante , Porcinos , Trasplante Autólogo/efectos adversos
4.
J Heart Lung Transplant ; 40(8): 814-821, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34083118

RESUMEN

BACKGROUND: The impact of donor sex on heart transplantation outcomes irrespective of recipient sex remains unclear. The objective of this study was to evaluate the impact of donor sex on heart transplantation outcomes in the United States. METHODS: From 1987 to March 2019, 63,775 adult patients who underwent heart transplantation were matched to 27,509 male and 11,474 female donors in the United States. Data were prospectively collected by the United Network for Organ Sharing (UNOS). Patients without missing data were stratified by donor sex and donor menopause status. The groups were matched 1:1 using the propensity score of each patient. Kaplan-Meier survival and cox proportional hazards regression analyses were performed. The primary endpoint was all-cause mortality. Secondary endpoints were postoperative complications. RESULTS: Propensity matching generated 15,506 and 1,094 patients based on donor sex and menopause status, respectively. Recipients who received female donor allografts were more likely to have acute rejection episodes requiring anti-rejection medical treatment (11.9% vs 10.1%, p = .007) and require post-transplant dialysis (10.9% vs 9.3%, p = .001) than those who received male donor allografts. Overall survival using female vs male donor allografts was similar (p = .34). Recipients who received pre- vs post-menopausal female donor hearts had similar postoperative outcomes and overall survival (p = .23). CONCLUSIONS: Analysis of the UNOS database showed similar median survival using female vs male donor hearts in adult heart transplantation, irrespective of donor menopause status. Female donor allografts are used far less frequently, thus these results represent an opportunity to maximize usage by better utilization of suitable female donor organs.


Asunto(s)
Rechazo de Injerto/epidemiología , Trasplante de Corazón , Complicaciones Posoperatorias/epidemiología , Puntaje de Propensión , Enfermedad Aguda , Aloinjertos , Causas de Muerte/tendencias , Femenino , Insuficiencia Cardíaca/cirugía , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Distribución por Sexo , Factores Sexuales , Tasa de Supervivencia/tendencias , Factores de Tiempo , Donantes de Tejidos , Obtención de Tejidos y Órganos , Estados Unidos/epidemiología
5.
J R Soc Interface ; 17(173): 20200614, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33259750

RESUMEN

Papillary muscles serve as attachment points for chordae tendineae which anchor and position mitral valve leaflets for proper coaptation. As the ventricle contracts, the papillary muscles translate and rotate, impacting chordae and leaflet kinematics; this motion can be significantly affected in a diseased heart. In ex vivo heart simulation, an explanted valve is subjected to physiologic conditions and can be adapted to mimic a disease state, thus providing a valuable tool to quantitatively analyse biomechanics and optimize surgical valve repair. However, without the inclusion of papillary muscle motion, current simulators are limited in their ability to accurately replicate cardiac biomechanics. We developed and implemented image-guided papillary muscle (IPM) robots to mimic the precise motion of papillary muscles. The IPM robotic system was designed with six degrees of freedom to fully capture the native motion. Mathematical analysis was used to avoid singularity conditions, and a supercomputing cluster enabled the calculation of the system's reachable workspace. The IPM robots were implemented in our heart simulator with motion prescribed by high-resolution human computed tomography images, revealing that papillary muscle motion significantly impacts the chordae force profile. Our IPM robotic system represents a significant advancement for ex vivo simulation, enabling more reliable cardiac simulations and repair optimizations.


Asunto(s)
Insuficiencia de la Válvula Mitral , Robótica , Biomimética , Cuerdas Tendinosas , Humanos , Músculos Papilares
6.
J Biomech Eng ; 142(1)2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31253992

RESUMEN

Few technologies exist that can provide quantitative data on forces within the mitral valve apparatus. Marker-based strain measurements can be performed, but chordal geometry and restricted optical access are limitations. Foil-based strain sensors have been described and work well, but the sensor footprint limits the number of chordae that can be measured. We instead utilized fiber Bragg grating (FBG) sensors-optical strain gauges made of 125 µm diameter silica fibers-to overcome some limitations of previous methods of measuring chordae tendineae forces. Using FBG sensors, we created a force-sensing neochord (FSN) that mimics the natural shape and movement of native chordae. FBG sensors reflect a specific wavelength of light depending on the spatial period of gratings. When force is applied, the gratings move relative to one another, shifting the wavelength of reflected light. This shift is directly proportional to force applied. The FBG sensors were housed in a protective sheath fashioned from a 0.025 in. flat coil, and attached to the chordae using polytetrafluoroethylene suture. The function of the force-sensing neochordae was validated in a three-dimensional (3D)-printed left heart simulator, which demonstrated that FBG sensors provide highly sensitive force measurements of mitral valve chordae at a temporal resolution of 1000 Hz. As ventricular pressures increased, such as in hypertension, chordae forces also increased. Overall, FBG sensors are a viable, durable, and high-fidelity sensing technology that can be effectively used to measure mitral valve chordae forces and overcome some limitations of other such technologies.


Asunto(s)
Cuerdas Tendinosas , Válvula Mitral , Fibras Ópticas
7.
J Heart Lung Transplant ; 35(6): 731-42, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26856669

RESUMEN

BACKGROUND: Allosensitization has been shown to negatively affect post-heart transplant (HTx) survival even with a negative crossmatch. Whether allosensitization related to mechanical circulatory support (MCS) is associated with worse post-HTx survival remains controversial. METHODS: Adult HTx recipients listed in the United Network for Organ Sharing database (July 2006-December 2012) were identified. Multivariate Cox regression assessed the effect of allosensitization on survival. Propensity matching was performed to compare patients who were and were not allosensitized. Kaplan-Meier survival analysis compared matched and unmatched patients in the MCS and medically managed cohorts. RESULTS: We identified 11,840 HTx recipients, of whom 4,167 had MCS. MCS was associated with allosensitization in multivariate logistic regression. Each different MCS device was associated with worse post-HTx survival in multivariate Cox regression. Allosensitization did not predict post-HTx mortality in MCS patients (hazard ratio, 1.07; 95% confidence interval, 0.89-1.28; p = 0.48. Among patients without MCS, allosensitization was associated with post-HTx mortality (hazard ratio, 1.19; 95% confidence interval, 1.03-1.39; p = 0.02). Kaplan-Meier analysis revealed equivalent survival in unmatched and matched cohorts when MCS patients who were allosensitized were compared with non-allosensitized MCS patients. Among non-MCS patients, allosensitization was associated with worse survival in unmatched and matched analysis. CONCLUSIONS: MCS was associated with allosensitization. For MCS patients, allosensitization did not independently predict worse post-HTx outcome. Among non-MCS patients, allosensitization was associated with worse post-HTx survival. Allosensitization appears to be a heterogeneous process influenced by presence of MCS.


Asunto(s)
Trasplante de Corazón , Oxigenación por Membrana Extracorpórea , Corazón Auxiliar , Humanos , Estimación de Kaplan-Meier , Estudios Retrospectivos , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 87(6): 1001-19, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26489034
9.
Semin Thorac Cardiovasc Surg ; 26(1): 36-43, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24952756

RESUMEN

Cardiac surgery is in the midst of a practice revolution. Traditionally, surgery for valvular heart disease consisted of valve replacement via conventional sternotomy using cardiopulmonary bypass. However, over the past 20 years, the increasing popularity of less-invasive procedures, accompanied by advancements in imaging, surgical instrumentation, and robotic technology, has motivated and enabled surgeons to develop and perform complex cardiac surgical procedures through small incisions, often eliminating the need for sternotomy or cardiopulmonary bypass. In addition to the benefits of improved cosmesis, minimally invasive mitral valve surgery was pioneered with the intent of reducing morbidity, postoperative pain, blood loss, hospital length of stay, and time to return to normal activity. This article reviews the current state-of-the-art of minimally invasive approaches to the surgical treatment of valvular heart disease.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Humanos
10.
Ann Thorac Surg ; 92(4): 1501-3, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21958802

RESUMEN

We report transventricular mitral valve operations in 2 patients with severe mitral regurgitation and postinfarction left ventricular rupture and pseudoaneurysm. The first patient had direct papillary muscle involvement necessitating replacement of the mitral valve. The second patient had indirect mitral involvement allowing for placement of an atrial mitral annuloplasty ring via the left ventricle. Both patients showed no mitral valve regurgitation after replacement or repair and had uneventful postoperative recoveries. These cases demonstrate a feasible, alternative, transventricular approach to mitral valve replacement and repair.


Asunto(s)
Cateterismo Cardíaco/métodos , Ventrículos Cardíacos/cirugía , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/cirugía , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico , Índice de Severidad de la Enfermedad
11.
Cell Mol Biol Lett ; 12(1): 127-38, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17119870

RESUMEN

Apelin interacts with the APJ receptor to enhance inotropy. In heart failure, apelin-APJ coupling may provide a means of enhancing myocardial function. The alterations in apelin and APJ receptor concentrations with ischemic cardiomyopathy are poorly understood. We investigated the compensatory changes in endogenous apelin and APJ levels in the setting of ischemic cardiomyopathy.Male, Lewis rats underwent LAD ligation and progressed into heart failure over 6 weeks. Corresponding animals underwent sham thoracotomy as control. Six weeks after initial surgery, the animals underwent hemodynamic functional analysis in the presence of exogenous apelin-13 infusion and the hearts were explanted for western blot and enzyme immunoassay analysis. Western blot analysis of myocardial APJ concentration demonstrated increased APJ receptor protein levels with heart failure (1890750+/-133500 vs. 901600+/-143120 intensity units, n=8, p=0.00001). Total apelin protein levels increased with ischemic heart failure as demonstrated by enzyme immunoassay (12.0+/-4.6 vs. 1.0+/-1.2 ng/ml, n=5, p=0.006) and western blot (1579400+/-477733 vs. 943000+/-157600 intensity units, n=10, p=0.008). Infusion of apelin-13 significantly enhanced myocardial function in sham and failing hearts. We conclude that total myocardial apelin and APJ receptor levels increase in compensation for ischemic cardiomyopathy.


Asunto(s)
Proteínas Portadoras/metabolismo , Regulación de la Expresión Génica , Isquemia Miocárdica/metabolismo , Miocardio/metabolismo , Receptores Acoplados a Proteínas G/metabolismo , Animales , Apelina , Receptores de Apelina , Presión Sanguínea/efectos de los fármacos , Western Blotting , Gasto Cardíaco/efectos de los fármacos , Glicosilación/efectos de los fármacos , Frecuencia Cardíaca/efectos de los fármacos , Ventrículos Cardíacos/efectos de los fármacos , Ventrículos Cardíacos/fisiopatología , Péptidos y Proteínas de Señalización Intercelular/administración & dosificación , Péptidos y Proteínas de Señalización Intercelular/farmacología , Masculino , Peso Molecular , Isquemia Miocárdica/fisiopatología , Miocardio/patología , Ratas , Ratas Endogámicas Lew
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA