Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Anal Bioanal Chem ; 416(15): 3605-3617, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38713223

RESUMEN

The analysis of dietary supplements is far less regulated than pharmaceuticals, leading to potential quality issues. Considering their positive effect, many athletes consume supplements containing L-histidine and ß-alanine. A new microfluidic method for the determination of L-histidine and ß-alanine in dietary supplement formulations has been developed. For the first time, capacitively coupled contactless conductivity detection was employed for the microchip electrophoresis of amino acids in real samples. A linear relationship between detector response and concentration was observed in the range of 10-100 µmol L-1 for L-histidine (R2 = 0.9968) and ß-alanine (R2 = 0.9954), while achieved limits of detection (3 × S/N ratio) were 4.2 µmol L-1 and 5.2 µmol L-1, respectively. The accuracy of the method was confirmed using recovery experiments as well as CE-UV-VIS and HPLC-UV-VIS techniques. The developed method allows unambiguous identification of amino acids in native form without chemical derivatization and with the possibility of simultaneous analysis of amino acids with metal cations.


Asunto(s)
Suplementos Dietéticos , Conductividad Eléctrica , Electroforesis por Microchip , Histidina , beta-Alanina , Electroforesis por Microchip/métodos , Suplementos Dietéticos/análisis , beta-Alanina/análisis , beta-Alanina/química , Histidina/análisis , Histidina/química , Límite de Detección , Tecnología Química Verde/métodos , Vidrio/química
2.
Sensors (Basel) ; 24(8)2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38676005

RESUMEN

Two new surfactant sensors were developed by synthesizing Pt-doped acid-activated multi-walled carbon nanotubes (Pt@MWCNTs). Two different ionophores using Pt@MWCNTs, a new plasticizer, and (a) cationic surfactant 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-DHBI (Pt@MWCNT-DHBI ionophore) and (b) anionic surfactant dodecylbenzenesulfonate-DBS (Pt@MWCNT-DBS ionophore) composites were successfully synthesized and characterized. Both surfactant sensors showed a response to anionic surfactants (dodecylsulfate (SDS) and DBS) and cationic surfactants (cetylpyridinium chloride (CPC) and hexadecyltrimethylammonium bromide (CTAB)). The Pt@MWCNT-DBS sensor showed lower sensitivity than expected with the sub-Nernstian response of ≈23 mV/decade of activity for CPC and CTAB and ≈33 mV/decade of activity for SDS and DBS. The Pt@MWCNT-DHBI surfactant sensor had superior response properties, including a Nernstian response to SDS (59.1 mV/decade) and a near-Nernstian response to DBS (57.5 mV/decade), with linear response regions for both anionic surfactants down to ≈2 × 10-6 M. The Pt@MWCNT-DHBI was also useful in critical micellar concentration (CMC) detection. Common anions showed very low interferences with the sensor. The sensor was successfully employed for the potentiometric titration of a technical grade cationic surfactant with good recoveries. The content of cationic surfactants was measured in six samples of complex commercial detergents. The Pt@MWCNT-DHBI surfactant sensor showed good agreement with the ISE surfactant sensor and classical two-phase titration and could be used as an analytical tool in quality control.

3.
Int J Mol Sci ; 24(19)2023 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-37834151

RESUMEN

The health supplement industry is one of the fastest growing industries in the world, but there is a lack of suitable analytical methods for the determination of active compounds in health supplements such as peptides. The present work describes an implementation of contactless conductivity detection on microchip technology as a new strategy for the electrophoretic determination of L-carnosine in complex health supplement formulations without pre-concentration and derivatization steps. The best results were obtained in the case of +1.00 kV applied for 20 s for injection and +2.75 kV applied for 260 s for the separation step. Under the selected conditions, a linear detector response of 5 × 10-6 to 5 × 10-5 M was achieved. L-carnosine retention time was 61 s. The excellent reproducibility of both migration time and detector response confirmed the high precision of the method. The applicability of the method was demonstrated by the determination of L-carnosine in three different samples of health supplements. The recoveries ranged from 91 to 105%. Subsequent analysis of the samples by CE-UV-VIS and HPLC-DAD confirmed the accuracy of the obtained results.


Asunto(s)
Carnosina , Electroforesis por Microchip , Electroforesis por Microchip/métodos , Reproducibilidad de los Resultados , Inyecciones , Conductividad Eléctrica , Dispositivos Laboratorio en un Chip
4.
Sensors (Basel) ; 23(5)2023 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-36904844

RESUMEN

Promethazine hydrochloride (PM) is a widely used drug so its determination is important. Solid-contact potentiometric sensors could be an appropriate solution for that purpose due to their analytical properties. The aim of this research was to develop solid-contact sensor for potentiometric determination of PM. It had a liquid membrane containing hybrid sensing material based on functionalized carbon nanomaterials and PM ions. The membrane composition for the new PM sensor was optimized by varying different membrane plasticizers and the content of the sensing material. The plasticizer was selected based on calculations of Hansen solubility parameters (HSP) and experimental data. The best analytical performances were obtained using a sensor with 2-nitrophenyl phenyl ether (NPPE) as the plasticizer and 4% of the sensing material. It had a Nernstian slope (59.4 mV/decade of activity), a wide working range (6.2 × 10-7 M-5.0 × 10-3 M), a low limit of detection (1.5 × 10-7 M), fast response time (6 s), low signal drift (-1.2 mV/h), and good selectivity. The working pH range of the sensor was between 2 and 7. The new PM sensor was successfully used for accurate PM determination in a pure aqueous PM solution and pharmaceutical products. For that purpose, the Gran method and potentiometric titration were used.

5.
Sensors (Basel) ; 23(4)2023 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-36850724

RESUMEN

The behavior of a new 1,3-dioctadecyl-1H-imidazol-3-ium tetraphenylborate (DODI-TPB) surfactant sensor was studied in single and complex mixtures of technical grade QACs-benzalkonium chloride (BAC), N,N-didecyl-N,N-dimethylammonium chloride (DDAC), and N,N-dioctyl-N,N-dimethylammonium chloride (DOAC) usually used in COVID-19 disinfecting agents formulations. The results obtained with the new DODI-TPB sensor were in good agreement with data measured by a 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-tetraphenylborate (DMI-TPB) surfactant sensor, as well as two-phase titration used as a reference method. The quantitative titrations of a two-component mixture of the cationic homologs (a) DDAC and DOAC; and (b) BAC and DOAC showed that the new DODI-TPB surfactant sensor can clearly distinguish two separate mixture components in a single potentiometric titration curve with two characteristic inflexion points. The consumption of SDS (used as a titrant) in the end-point 1 (EP 1) corresponded to the content of DDAC (or BAC), whereas the consumption in the end-point 2 (EP 2) corresponded to the total content of both cationic surfactants in the mixture. DOAC content in both mixtures can be calculated from the difference of the titrant used to achieve EP1 and EP2. The addition of nonionic surfactants resulted in the signal change decrease from 333.2 mV (1:0; no nonionic surfactant added) to 243.0 mV (1:10, w/w). The sensor was successfully tested in ten two-component COVID-19 disinfecting formulations.


Asunto(s)
COVID-19 , Tensoactivos , Humanos , Tetrafenilborato , Compuestos de Benzalconio
6.
Sensors (Basel) ; 22(23)2022 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-36501843

RESUMEN

A low-cost and fast potentiometric surfactant sensor for cationic surfactants, based on the new ion-pair 1,3-dioctadecyl-1H-imidazol-3-ium-tetraphenylborate (DODI-TPB), is presented. The new cationic surfactant DODI-Br was synthesized and characterized by NMR, LC-MS, and elemental analysis, and was used for synthesis of the DODI-TPB ionophore. The DODI-TPB surfactant sensor was obtained by implementation of the ionophore in PVC. The sensor showed excellent response characteristics with near-Nernstian slopes to the cationic surfactants DMIC, CPC, CTAB, and Hyamine 1622. The highest voltage responses were obtained for DMIC and CPC (58.7 mV/decade of activity). DMIC had the lowest detection limit (0.9 × 10-6 M) and the broadest useful linear concentration range (1.8 × 10-6 to 1.0 × 10-4 M). An interference study showed remarkable stability. Potentiometric titration curves for the titration of cationic surfactants (DMIC, CPC, CTAB, and Hyamine 1622), with DDS and TPB used as titrants, showed sigmoidal curves with well-defined inflexion points and a broad signal change. The standard addition method was successfully applied with recovery rates from 98.9 to 101.2 at two concentrations. The amount of cationic surfactant found in disinfectants and antiseptics was in good agreement with the referent two-phase titration method and the surfactant sensor on the market. This new surfactant sensor represents a low-cost alternative to existing methods for cationic surfactant detection.


Asunto(s)
Tensoactivos , Tetrafenilborato , Tensoactivos/química , Concentración de Iones de Hidrógeno , Potenciometría/métodos , Ionóforos , Tetrafenilborato/química
7.
Sensors (Basel) ; 22(10)2022 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-35632191

RESUMEN

Direct potentiometric measurements using solid-state sensors have a great potential for thiabendazole (TBZ) determination, considering simplicity, accuracy, and low cost. Modifying the sensing material of the sensor with multi-walled carbon nanotubes (MWCNTs) leads to improved analytical properties of the sensor. In this study, a new potentiometric solid-state sensor for TBZ determination, based on MWCNTs modified with a sulfate group, and TBZ ion as sensing material was developed. The sensor exhibited a Nernstian response for TBZ (60.4 mV/decade of activity) in a working range between 8.6 × 10-7 and 1.0 × 10-3 M. The detection limit for TBZ was 6.2 × 10-7 M. The response time of the sensor for TBZ was 8 s, and its signal drift was only 1.7 mV/h. The new sensor is applicable for direct potentiometric determination of TBZ in complex real samples, such as fruit peel. The accuracy of TBZ determination is confirmed using the standard addition method.


Asunto(s)
Nanotubos de Carbono , Materiales Inteligentes , Electrodos , Potenciometría , Tiabendazol
8.
Antioxidants (Basel) ; 10(7)2021 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-34203479

RESUMEN

Carnosine is a dipeptide synthesized in the body from ß-alanine and L-histidine. It is found in high concentrations in the brain, muscle, and gastrointestinal tissues of humans and is present in all vertebrates. Carnosine has a number of beneficial antioxidant properties. For example, carnosine scavenges reactive oxygen species (ROS) as well as alpha-beta unsaturated aldehydes created by peroxidation of fatty acid cell membranes during oxidative stress. Carnosine can oppose glycation, and it can chelate divalent metal ions. Carnosine alleviates diabetic nephropathy by protecting podocyte and mesangial cells, and can slow down aging. Its component, the amino acid beta-alanine, is particularly interesting as a dietary supplement for athletes because it increases muscle carnosine, and improves effectiveness of exercise and stimulation and contraction in muscles. Carnosine is widely used among athletes in the form of supplements, but rarely in the population of cardiovascular or diabetic patients. Much less is known, if any, about its potential use in enriched food. In the present review, we aimed to provide recent knowledge on carnosine properties and distribution, its metabolism (synthesis and degradation), and analytical methods for carnosine determination, since one of the difficulties is the measurement of carnosine concentration in human samples. Furthermore, the potential mechanisms of carnosine's biological effects in musculature, metabolism and on immunomodulation are discussed. Finally, this review provides a section on carnosine supplementation in the form of functional food and potential health benefits and up to the present, neglected clinical use of carnosine.

9.
Molecules ; 26(12)2021 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-34198483

RESUMEN

A 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-tetraphenylborate (DHBI-TPB) ion-pair implemented in DHBI-TPB surfactant sensor was used for the potentiometric quantification of anionic surfactants in detergents and commercial household care products. The DHBI-TPB ion-pair was characterized by FTIR spectroscopy and computational analysis which revealed a crucial contribution of the C-H∙∙∙π contacts for the optimal complex formation. The DHBI-TPB sensor potentiometric response showed excellent analytical properties and Nernstian slope for SDS (60.1 mV/decade) with LOD 3.2 × 10-7 M; and DBS (58.4 mV/decade) with LOD 6.1 × 10-7 M was obtained. The sensor possesses exceptional resistance to different organic and inorganic interferences in broad pH (2-10) range. DMIC used as a titrant demonstrated superior analytical performances for potentiometric titrations of SDS, compared to other tested cationic surfactants (DMIC > CTAB > CPC > Hyamine 1622). The combination of DHBI-TPB sensor and DMIC was successfully employed to perform titrations of the highly soluble alkane sulfonate homologues. Nonionic surfactants (increased concentration and number of EO groups) had a negative impact on anionic surfactant titration curves and a signal change. The DHBI-TPB sensor was effectively employed for the determination of technical grade anionic surfactants presenting the recoveries from 99.5 to 101.3%. The sensor was applied on twelve powered samples as well as liquid-gel and handwashing home care detergents containing anionic surfactants. The obtained results showed good agreement compared to the outcomes measured by ISE surfactant sensor and a two-phase titration method. The developed DHBI-TPB surfactant sensor could be used for quality control in industry and has great potential in environmental monitoring.


Asunto(s)
Detergentes/química , Imidazoles/química , Ionóforos/química , Polímeros/química , Potenciometría/métodos , Tensoactivos/análisis , Aniones/análisis , Electrodos , Concentración de Iones de Hidrógeno
10.
Sensors (Basel) ; 21(10)2021 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-34069524

RESUMEN

Surfactant liquid-membrane type sensors are usually made of a PVC, ionophore and a plasticizer. Plasticizers soften the PVC. Due to their lipophilicity, they influence the ion exchange across the membrane, ionophore solubility, membrane resistance and, consequently, the analytical signal. We used the DMI-TPB as an ionophore, six different plasticizers [2-nitrophenyl-octyl-ether (P1), bis(2-ethylhexyl) phthalate (P2), bis(2-ethylhexyl) sebacate (P3), 2-nitrophenyl phenyl ether (P4), dibutyl phthalate (P5) and dibutyl sebacate (P6)] and a PVC to produce ionic surfactant sensors. Sensor formulation with P1 showed the best potentiometric response to four usually used cationic surfactant, with the lowest LOD, 7 × 10-7 M; and potentiometric titration curves with well-defined and sharp inflexion points. The sensor with P6 showed the lowest analytical performances. Surfactant sensor with P1 was selected for quantification of cationic surfactant in model solutions and commercial samples of disinfectants and antiseptics. It showed high accuracy and precision in all determinations, with recovery from 98.2 to 99.6, and good agreement with the results obtained with surfactant sensor used as a referent one, and a standard two-phase titration method. RDS values were lower than 0.5% for all determinations.


Asunto(s)
Antiinfecciosos Locales , Desinfectantes , Concentración de Iones de Hidrógeno , Plastificantes , Cloruro de Polivinilo , Potenciometría , Tensoactivos
11.
Molecules ; 26(5)2021 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-33806643

RESUMEN

A novel, simple, low-cost, and user-friendly potentiometric surfactant sensor based on the new 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-tetraphenylborate (DHBI-TPB) ion-pair for the detection of cationic surfactants in personal care products and disinfectants is presented here. The new cationic surfactant DHBI-Br was successfully synthesized and characterized by nuclear magnetic resonance (NMR), Fourier transform infrared (FTIR) spectrometry, liquid chromatography-mass spectrometry (LC-MS) and elemental analysis and was further employed for DHBI-TPB ion-pair preparation. The sensor gave excellent response characteristics for CTAB, CPC and Hyamine with a Nernstian slope (57.1 to 59.1 mV/decade) whereas the lowest limit of detection (LOD) value was measured for CTAB (0.3 × 10-6 M). The sensor exhibited a fast dynamic response to dodecyl sulfate (DDS) and TPB. High sensor performances stayed intact regardless of the employment of inorganic and organic cations and in a broad pH range (2-11). Titration of cationic and etoxylated (EO)-nonionic surfactant (NSs) (in Ba2+) mixtures with TPB revealed the first inflexion point for a cationic surfactant and the second for an EO-nonionic surfactant. The increased concentration of EO-nonionic surfactants and the number of EO groups had a negative influence on titration curves and signal change. The sensor was successfully applied for the quantification of technical-grade cationic surfactants and in 12 personal care products and disinfectants. The results showed good agreement with the measurements obtained by a commercial surfactant sensor and by a two-phase titration. A good recovery for the standard addition method (98-102%) was observed.


Asunto(s)
Técnicas Biosensibles/métodos , Cationes/química , Cosméticos/análisis , Desinfectantes/análisis , Imidazoles/química , Potenciometría/métodos , Tensoactivos/química , Concentración de Iones de Hidrógeno
12.
Crit Rev Anal Chem ; 51(2): 115-137, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-31690085

RESUMEN

Anionic surfactants are important components of many products used in everyday life in all households. They are also applied in various industrial fields at a very large scale. Since they have a negative influence on the environment, it is an imperative to monitor their concentration in aquatic ecosystems. Therefore, it is of great importance to develop new methods for the determination of a wide spectra of anionic surfactants in complex environmental samples in a short time. A comprehensive review of potentiometric sensors for the determination of anionic surfactants in the last 50 years is given with special concern to papers published since 2000, but noting some earlier published important papers. The latest development in use of new ionophores, polymer formulations, and nanomaterials is presented. Additionally, the application of new potentiometric sensors in batch mode or in miniaturized microfluidic methods is discussed.


Asunto(s)
Potenciometría/métodos , Tensoactivos/análisis , Aniones/química , Electrodos , Ionóforos/química , Nanoestructuras/química , Polímeros/química , Potenciometría/instrumentación , Transistores Electrónicos
13.
Food Technol Biotechnol ; 58(1): 5-11, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32684782

RESUMEN

The botanical origin of starch is of importance in industrial applications and food processing because it may influence the properties of the final product. Current microscopic methods are time-consuming. Starch consists of an origin-dependent amylose/amylopectin ratio. Triiodide ions bind characteristically to the amylose and amylopectin depending on the botanical origin of the starch. The absorbance of the starch-triiodide complex was measured for: wheat, potato, corn, rye, barley, rice, tapioca and unknown origin starch; and within the different cultivars. Each starch sample had specific parameters: starch-triiodide complex peak wavelength maximum (λ max/nm), maximum absorbance change at λ max (ΔA) and λ max shift towards the unknown origin starch sample values. The visible absorption spectra (500-800 nm) for each starch sample were used as a unique fingerprint, and then elaborated by cluster analysis. The cluster analysis managed to distinguish data of two clusters, a cereal type cluster and a potato/tapioca/rice starch cluster. The cereal subclusters extensively distinguished wheat/barley/rye starches from corn starches. Data for cultivars were mostly in good agreement within the same subclaster. The proposed method that combines cluster analysis and visible absorbance data for starch-triiodide complex was able to distinguish starch of different botanical origins and cultivars within the same species. This method is simpler and more convenient than standard time-consuming methods.

14.
Anal Bioanal Chem ; 410(18): 4359-4369, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29707755

RESUMEN

Microchip electrophoresis (ME) was applied for the separation of two physiologically important imidazole dipeptides-carnosine and anserine. The capacitively coupled contactless conductivity detector (C4D) was employed for quantification of both dipeptides after separation in a new home-built ME unit. The separation parameters were optimized as follows to enable quantitative, baseline separation of both dipeptides: injection time 16 s, injection voltage 900 V/cm, and separation voltage 377.1 V/cm. The C4D detector responded linearly to both imidazole dipeptides in the range 0-20 mg L-1. The known addition methodology was applied to test the accuracy of the measurement of imidazole dipeptides in a complex sample. The recoveries for measurement of carnosine in the mixture ranged from 96.1 to 105.0%, whereas those for anserine amounted to 96.6 to 102.0%. This method was also applied to real biological samples. The results exhibited a satisfactory agreement with a standard HPLC method. The proposed ME method represents a cheap, fast, and simple alternative to the existing, more complicated and expensive HPLC methods. This method does not demand either the optical detectors nor tedious derivatization of sample, which are unavoidable in HPLC methods. The method was succesfuly applied for animal species determination in unknown meat samples using the carnosine/anserine ratio, and subsequently, it could be used in a food fraud prevention process. Graphical abstract Microchip electrophoresis portable device with a C4D detector for determination of imidazole dipeptides in model samples and real meat samples from different animal species.


Asunto(s)
Anserina/análisis , Carnosina/análisis , Electroforesis por Microchip/métodos , Carne/análisis , Animales , Bovinos , Pollos , Cromatografía Líquida de Alta Presión/métodos , Análisis Costo-Beneficio , Conductividad Eléctrica , Técnicas Electroquímicas/instrumentación , Electroforesis por Microchip/economía , Caballos , Imidazoles/química , Límite de Detección , Conejos , Reproducibilidad de los Resultados , Especificidad de la Especie
15.
Food Chem ; 221: 1658-1665, 2017 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-27979143

RESUMEN

A home-made microchip electrophoresis (MCE) device was used to quantitate two biologically important histidine dipeptides, carnosine and anserine, using capacitively coupled contactless conductivity detection (C4D), at pH 2.7. The C4D detector exhibited a linear response to both carnosine and anserine in the range of 0-200µM for the individual dipeptides and in the range of 0-100µM for each dipeptide when both were present as a mixture. The limit of detections (LOD) for the dipeptides in the mixture were 0.10µM for carnosine and 0.16µM for anserine. Standard addition was used to detemine the accuracy of the method. For carnosine and anserine the recoveries were in the range of 96.7±4.9-106.0±7.5% and 95.3±4.5-105.0±5.1% in thigh muscle and 97.5±5.1-105.0±7.5% and 95.3±5.4-97.3±5.6% in breast muscle, respectively.


Asunto(s)
Anserina/análisis , Carnosina/análisis , Electroforesis Capilar/métodos , Músculo Esquelético/química , Animales , Pollos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA