Resultados 1 - 20 de 142
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39422931

RESUMEN

BACKGROUND: Monitoring liver changes is crucial in the management of liver fibrosis. Current diagnostic methods include liver function tests such as the Liver Maximum Capacity (LiMAx) test and measurements of liver stiffness. While the LiMAx test quantifies liver function through 13C-methacetin metabolism, ultrasound (US) elastography noninvasively assesses liver stiffness. The relationship between the findings of these methods in patients with liver fibrosis is not fullyunderstood. OBJECTIVE: This study evaluated the correlation between LiMAx measurements of liver function and US elastography-based liver stiffness measurements to better understand the interplay between functional and structural liver parameters in fibrotic liver disease. Additionally, the relationship between body mass index (BMI) and these parameters isevaluated. METHODS: This retrospective study analysed data from 97 patients who underwent both LiMAx testing and real-time elastography, resulting in a total data set of 108 examinations. The correlations between the results of the LiMAx test and elastography and their relationships with body mass index (BMI) were analysed. RESULTS: There was a significant negative correlation (r = -0.25, p < 0.05) between LiMAx test values and liver stiffness measurements. BMI was significantly negatively correlated with LiMAx values (r = -0.29, p < 0.001) but not significantly correlated with liver stiffness values. CONCLUSIONS: This retrospective study confirms the results of previous studies showing a notable but weak association between liver function and liver stiffness. Our results highlight the potential value of both tests as complementary tools for the evaluation of liver health, reinforcing the necessity for a multimodal approach to liver assessment.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39331096

RESUMEN

BACKGROUND AND OBJECTIVE: Ultrasound-guided interventions (such as biopsies) of unclear lesions are indicated if microcirculatory changes indicate possible malignant lesions. These place high demands on the ultrasound device used. In order to potentially reduce the often associated high technical effort, the wireless ultrasound device Vscan AirTM was examined as a possible ultrasound device for the intervention biopsy. METHODS: As part of an advanced training course on Computertomographie- and ultrasound-guided biopsy and ablation procedures, participants were asked about the image quality of the handheld device used by means of questionnaires. Various lesions were evaluated at a depth of 1.0 to 5.0 cm in an in vitro liver model. The image quality was evaluated independently before, during and after the intervention. The rating scale contained values from 0 (no assessment possible) to 5 (maximum high image quality). A high-end device was used as a reference. RESULTS: A total of 11 participants took part in the study (n = 4 male [36.4%], n = 7 female [63.6%]). A total of five tumor like lesions at different depths (1 cm, 2 cm, 3 cm, 4 cm, >4 cm) were assessed separately. In all cases, an adequate biopsy of the target lesion (1 cm in length, core filling 5 mm) was successful. From a depth of 3 cm, the image quality of the mobile device increasingly decreased, but the image quality of the high-end system was still not impaired. Compared to the high-end device, there was a highly significant difference in image quality from a depth of 3 cm (p < 0.01). Assessment by inexperienced examiners using a handheld device was adequately possible. CONCLUSIONS: Mobile interventional ultrasound represents a potential alternative for the biopsy of unclear tumorous lesions with microcirculatory disorders with limited depth localization.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39331097

RESUMEN

OBJECTIVE: To assess diagnostic capabilities of a modern handheld ultrasound device (HUD) for portal vein (PV) evaluation in pediatric patients and to verify if age, body mass index (BMI) and object depth correlate to imagequality. METHODS: 45 patients (3.9 months- 17.9 years; 10.3 years±5.4) were examined using a HUD and cart-based high-end ultrasound system (HEUS). The intra-and extrahepatic PV was scanned using B-Mode and Color-coded Doppler sonography (CCDS). A five-point Likert scale was applied to evaluate image quality. Results were interpreted by two readers in consensus. Scores were compared between the scanners and correlated to age, BMI and skin-to-portal-vein-distance (SPVD). The influence on image quality and the difference between the two devices were analyzed using ordinal and Bayesian logistic regression models. RESULTS: ≥4 points (mild or no limitations) were achieved by the HUD in 60% for B-Mode and 56% for CCDS. There was a statistically significant negative correlation between the image quality achieved by the HUD and the SPVD for B-Mode and CCDS. The effect of BMI and SPVD on having≥4 points differed significantly between the HUD and HEUS for B-Mode (OR = 0.191, p = 0.005, and OR = 0.040, p = 0.008) and for CCDS (OR = 0.209, p = 0.009, and OR = 0.084,p = 0.011). CONCLUSIONS: Sufficient to excellent image quality for portal vein assessment in pediatric patients was achieved by the HUD except for the most deep-lying structures. Compared to HEUS, diagnostic performance of the HUD is lower, based on a negative correlation with object depth.

4.
J Gastrointestin Liver Dis ; 33(3): 362-371, 2024 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-39348590

RESUMEN

BACKGROUND AND AIMS: To evaluate, if high frame rate (HiFR) contrast-enhanced ultrasound (CEUS) and external perfusion analysis (VueBox®)can give answers on liver tumour diagnostics. METHODS: A multifrequency probe (C1-6 /Resona R9) and 1-2.4 ml ultrasound contrast medium were used for CEUS up to 5-6 min. Independent analysis of DICOM-CINE files was performed, correlated to follow-up, computed tomography, magnetic resonance imaging, or histopathology. RESULTS: In 110 patients the difference between marginal peak enhancement (PE) of malignant and benign leasions was significant. In the peripheral area, the AUCs were lower in malignant lesions (144.8±139.3) than in benign lesions (123.6±119.8). The mean transit time (mTT) was shorter in malignant lesions in the center. In the liver parenchyma, however, the mTT was significantly longer in malignant lesions (141.6±107.9s) than in benign lesions (128.8±138.6 s). The rise time (RT) was significantly shorter central (66.5±30.9s) and peripheral (72.8±35.1s) in malignant lesions than in benign lesions (114.33±159.58s). The wash in rate (WiR) in benign lesions was 848.3±2,563.7 rU in the center. Wash-out rate (WoR) in the center, peripheral and in the liver parenchyma showed a significantly lower wash-out in the malignant lesions. CONCLUSIONS: HiFR CEUS with perfusion analysis enables the assessment of focal, diffuse and post-interventional liver changes.


Asunto(s)
Medios de Contraste , Neoplasias Hepáticas , Valor Predictivo de las Pruebas , Ultrasonografía , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Medios de Contraste/administración & dosificación , Masculino , Femenino , Persona de Mediana Edad , Anciano , Ultrasonografía/métodos , Adulto , Imagen de Perfusión/métodos , Factores de Tiempo , Anciano de 80 o más Años , Hígado/diagnóstico por imagen , Hígado/patología , Resultado del Tratamiento , Circulación Hepática , Imagen por Resonancia Magnética/métodos
5.
Diagnostics (Basel) ; 14(18)2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39335680

RESUMEN

Angiomyolipoma (AML) are the most common benign solid renal mass. Differentiation from malignant tumours is essential. Imaging features in ultrasound may overlap between malignant lesions, especially between renal cell carcinoma (RCC) and AML. So far, sectional imaging has been necessary for reliable differentiation. The aim of this study is to evaluate the use of the ultrasound-guided attenuation parameter (UGAP), a recently established tool for assessing hepatic steatosis, in the differentiation of AMLs from other renal masses. Therefore, 27 patients with unknown solid renal masses were examined by ultrasound including UGAP. The attenuation was assessed qualitatively by attenuation map and quantitatively in comparison to the surrounding renal tissue. UGAP was applicable in 26/27 patients. Findings were compared with CT/MRI as the current imaging standard. A total of 18 AML and 9 other renal tumours were found. The diagnostic performance of B-Mode (hyperechogenic lesion) ultrasound was 77.8% in identifying AML. The diagnostic performance of the attenuation map showed a diagnostic performance of 92.6%, whereby UGAP measurements were successful in 76.9% of cases. Quantitatively, we found a significant difference (p < 0.034) in mean measured attenuation between AML (0.764 ± 0.162 dB/cm/MHz) vs. other renal tumours (0.658 ± 0.155 dB/cm/MHz). The best performance was found by a combined parameter of a hyperechogenic lesion with a positive attenuation map with an accuracy of 95.0%. In conclusion, UGAP may represent a possibility for differentiating solid renal lesions more accurately by ultrasound, especially classic hyperechoic AMLs from other renal lesions. Further studies are needed to increase the diagnostic reliability further.

6.
Life (Basel) ; 14(9)2024 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-39337981

RESUMEN

BACKGROUND: The aim of this study was to evaluate the performance and the impact of contrast-enhanced intraoperative ultrasound (CE-IOUS) on intraoperative decision-making, as there is still no standardized protocol for its use. Therefore, we retrospectively analyzed multiple CE-IOUS performed in hepato-pancreatic-biliary surgery with respect to pre- and postoperative imaging and histopathological findings. METHODS: Data of 50 patients who underwent hepato-pancreatic-biliary surgery between 03/2022 and 03/2024 were retrospectively collected. CE-IOUS was performed with a linear 6-9 MHz multifrequency probe connected to a high-resolution device. The ultrasound contrast agent used was a stabilized aqueous suspension of sulphur hexafluoride microbubbles. RESULTS: In total, all 50 lesions indicated for surgery were correctly identified. In 30 cases, CE-IOUS was used to localize the primary lesion and to define the resection margins. In the remaining 20 cases, CE-IOUS identified an additional lesion. Fifteen of these findings were identified as malignant. In eight of these cases, the additional malignant lesion was subsequently resected. In the remaining seven cases, CE-IOUS again revealed an inoperable situation. In summary, CE-IOUS diagnostics resulted in a high correct classification rate of 95.7%, with positive and negative predictive values of 95.2% and 100.0%, respectively. CONCLUSIONS: CE-IOUS shows excellent performance in describing intraoperative findings in hepato-pancreatic-biliary surgery, leading to a substantial impact on intraoperative decision-making.

7.
Diagnostics (Basel) ; 14(15)2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39125473

RESUMEN

BACKGROUND: Suspicious tumors of the lung require specific staging, intraoperative detection, and histological confirmation. We performed an intrathoracic, intraoperative contrast-enhanced ultrasound (Io-CEUS) for characterization of lung cancer. METHODS: Retrospective analysis of prospectively collected data on the application of Io-CEUS in thoracic surgery for patients with operable lung cancer. Analysis of the preoperative chest CT scan and FDG-PET/CT findings regarding criteria of malignancy. Immediately before lung resection, the intrathoracic Io-CEUS was performed with a contrast-enabled T-probe (6-9 MHz-L3-9i-D) on a high-performance ultrasound machine (Loqic E9, GE). In addition to intraoperative B-mode, color-coded Doppler sonography (CCDS), or power Doppler (macrovascularization) of the lung tumor, contrast enhancement (Io-CEUS) was used after venous application of 2.4-5 mL sulfur hexafluoride (SonoVue, Bracco, Italy) for dynamic recording of microvascularization. The primary endpoint was the characterization of operable lung cancer with Io-CEUS. Secondly, the results of Io-CEUS were compared with the preoperative staging. RESULTS: The study included 18 patients with operable lung cancer, who received Io-CEUS during minimally invasive thoracic surgery immediately prior to lung resection. In the chest CT scan, the mean size of the lung tumors was 2.54 cm (extension of 0.7-4.5 cm). The mean SUV in the FDG-PET/CT was 7.6 (1.2-16.9). All lung cancers were detected using B-mode and power Doppler confirmed macrovascularization (100%) of the tumors. In addition, Io-CEUS showed an early wash-in with marginal and mostly simultaneous central contrast enhancement. CONCLUSIONS: The intrathoracic application of Io-CEUS demonstrated a peripheral and simultaneous central contrast enhancement in the early phase, which seems to be characteristic of lung cancer. In comparison to preoperative imaging, Io-CEUS was on par with the detection of malignancy and offers an additional tool for the intraoperative assessment of lung cancer before resection.

8.
Rofo ; 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39038458

RESUMEN

V-flow is a dynamic ultrasound technique that visualizes perfusion patterns by displaying dynamic arrows that change in response to the flow of erythrocytes. Furthermore, it provides quantitative values for the maximum and mean velocity of blood flow as well as a percentage value for turbulence. The aim was to enhance the preoperative diagnostic accuracy of thyroid lesions by combining V-flow with established ultrasound modes.B-mode, CCDS, elastography, CEUS, and V-flow were performed on 101 patients. After the ultrasound examination, every nodule was confirmed as benign or malignant via histopathology. The Kruskal-Wallis test, ROC curve, and binary logistic regression were used for the statistical analysis.93 benign regressive thyroid nodules and 8 carcinomas were included in this study. The average mean velocity value for benign lesions was measured at 19.5 cm/s and at 10.7 cm/s for malignant lesions (p = 0.039). The average turbulence percentage was 26.1% for benign nodules and 46.7% for carcinomas (p = 0.016). Carcinomas exhibited a slower and more turbulent perfusion pattern compared to benign tumors. A V-flow-centered system achieves a sensitivity of 100.0% and a specificity of 84.9% in predicting malignancy. This system could have reduced the number of unnecessary thyroid surgeries for benign lesions in our patient group by 70%.The capillary perfusion of thyroid nodules represents a significant indicator of its status. By analyzing the velocity and turbulence level of microvascular blood flow, V-flow offers promising prospects for accurately distinguishing between benign and malignant thyroid lesions. When integrated into a comprehensive multimodal sonographic imaging approach, V-flow further enhances diagnostic accuracy. · V-flow allows for qualitative and quantitative analysis of microvascular perfusion. · Malignant tumors are associated with slower and more turbulent microvascular hemodynamics. · Combining V-flow with other ultrasound modes eases the diagnosis of thyroid carcinomas. · Brandenstein MK, Zhang L, Scharf G et al. The impact of V-flow on preoperative diagnosis of thyroid tumors: individually and as part of multimodal sonographic imaging. Fortschr Röntgenstr 2024; DOI 10.1055/a-2350-0107.

9.
Rofo ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38885652

RESUMEN

Over the last few years, there has been an increasing focus on integrating artificial intelligence (AI) into existing imaging systems. This also applies to ultrasound. There are already applications for thyroid and breast lesions that enable AI-assisted sonography directly on the device. However, this is not yet the case for lymph nodes.The aim was to test whether already established programs for AI-assisted sonography of breast lesions and thyroid nodules are also suitable for identifying and measuring superficial lymph nodes. For this purpose, the two programs were used as a supplement to routine ultrasound examinations of superficial lymph nodes. The accuracy of detection by AI was then evaluated using a previously defined score. If available, a comparison was made with cross-sectional imaging.The programs that were used are able to adequately detect lymph nodes in the majority of cases (78.6%). Problems were caused in particular by a high proportion of echo-rich fat, blurred differentiation from the surrounding tissues and the occurrence of lymph node conglomerates. The available cross-sectional images did not contradict the classification of the lesion as a lymph node in any case.In the majority of cases, the tested programs are already able to detect and measure superficial lymph nodes. Further improvement can be expected through specific training of the software. Further developments and studies are required to assess risk of malignancy. · The inclusion of AI in imaging is increasingly becoming a scientific focus.. · The detection of lymph nodes is already possible using device-integrated AI software.. · Malignancy assessment of the detected lymph nodes is not yet possible.. · Rink M, Künzel J, Stroszczynski C et al. Smart scanning: automatic detection of superficially located lymph nodes using ultrasound - initial results. Fortschr Röntgenstr 2024; DOI 10.1055/a-2331-0951.

10.
J Gastrointestin Liver Dis ; 33(2): 194-202, 2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-38944869

RESUMEN

BACKGROUND AND AIMS: Ultra-microangiography (UMA) is a novel Doppler technique with optimized wall filtering that provides high sensitivity to low-velocity blood flows and optimized visualization of microcirculation. The aim of this pilot study was to compare intestinal vascularization assessed by color Doppler signals (CDS) and UMA. METHODS: We investigated intestinal vascularization using UMA and CDS in 13 patients with confirmed inflammatory bowel disease (IBD). A cohort of 28 patients without structural bowel disease served as the control. RESULTS: Microcirculation and dysregulated microcirculation in patients without and with inflammatory bowel disease can be visualized and quantified using UMA. In 83 % of IBD patients and 76% of non-IBD patients, a high resolution of intestinal perfusion could be achieved using UMA. CONCLUSIONS: To the best of our knowledge, this is the first study to investigate intestinal vascularization using UMA in patients with and without structural bowel disease. Quantification and visualization of intestinal vascularization should be further investigated in prospective studies and could help guide our therapy of patients with IBD.


Asunto(s)
Intestinos , Microcirculación , Humanos , Proyectos Piloto , Microcirculación/fisiología , Femenino , Masculino , Adulto , Persona de Mediana Edad , Intestinos/irrigación sanguínea , Intestinos/diagnóstico por imagen , Enfermedades Inflamatorias del Intestino/diagnóstico por imagen , Enfermedades Inflamatorias del Intestino/fisiopatología , Ultrasonografía Doppler en Color , Angiografía/métodos , Anciano , Adulto Joven , Valor Predictivo de las Pruebas , Estudios de Casos y Controles
11.
Clin Hemorheol Microcirc ; 86(3): 263-273, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38489171

RESUMEN

BACKGROUND: The continuous development of ultrasound techniques increasingly enables better description and visualization of unclear lesions. New ultrasound systems must be evaluated with regard to all these diagnostic possibilities. METHODS: A multifrequency C1-7 convex probe (SC7-1M) with the new high-end system Resona A20 Series was used. Modern technologies, including HiFR CEUS, SR CEUS and multimodal tissue imaging with shear wave elastography (SWE), fat evaluation and viscosity measurements (M-Ref) were applied. RESULTS: Of n = 70 (mean value 48,3 years±20,3 years, range 18-84 years) cases examined, a definitive diagnosis could be made in n = 67 cases, confirmed by reference imaging and/or follow-up. Of these, n = 22 cases were malignant changes (HCC (hepatocellular carcinoma) n = 9, CCC (cholangiocellular carcinoma) n = 3, metastases of colorectal carcinomas or recurrences of HCC n = 10). In all 12 cases of HCC or CCC, the elastography measurements using the shear wave technique (with values >2 m/s to 3.7 m/s) showed mean values of 2.3±0.31 m/s and a degree of fibrosis of F2 to F4. In n = 14 cases, changes in the fat measurement (range 0.51 to 0.72 dB/cm/MHz, mean values 0.58±0.12 dB/cm/MHz) in the sense of proportional fatty changes in the liver were detected. In the 4 cases of localized fat distribution disorders, the values were >0.7 dB/cm/MHz in the sense of significant fatty deposits in the remaining liver tissue. Relevant changes in the viscosity measurements with values >1.8 kPa were found in n = 31 cases, in n = 5 cases of cystic lesions with partially sclerosing cholangitis, in n = 13 cases of malignant lesions and in n = 9 cases post-interventionally, but also in n = 4 cases of benign foci with additional systemic inflammation. CONCLUSIONS: The results are promising and show a new quality of ultrasound-based liver diagnostics. However, there is a need for further investigations with regard to the individual aspects, preferably on a multi-center basis.


Asunto(s)
Carcinoma Hepatocelular , Diagnóstico por Imagen de Elasticidad , Neoplasias Hepáticas , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Medios de Contraste , Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Viscosidad , Hígado/diagnóstico por imagen , Hígado/patología , Ultrasonografía/métodos
12.
Ultraschall Med ; 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38335990

RESUMEN

PURPOSE: Complete resection of the affected tissue remains the best curative treatment option for liver-derived tumors and colorectal liver metastases. In addition to preoperative cross-sectional imaging, contrast-enhanced intraoperative ultrasound (CE-IOUS) plays a crucial role in the detection and localization of all liver lesions. However, its exact role is unclear. This study was designed to evaluate the clinical and oncological impact of using CE-IOUS in the surgical treatment of these diseases. MATERIALS AND METHODS: Over the three-year study period, 206 patients with primary liver tumors and hepatic metastases were enrolled in this prospective, monocentric study to evaluate the impact of CE-IOUS in liver surgery. Secondary outcomes included comparing the sensitivity and specificity of CE-IOUS with existing preoperative imaging modalities and identifying preoperative parameters that could predict a strategic impact of CE-IOUS. In addition, the oncological significance of CE-IOUS was evaluated using a case-cohort design with a minimum follow-up of 18 months. RESULTS: CE-IOUS findings led to a change in surgical strategy in 34% of cases (n=70/206). The accuracy in cases with a major change could be confirmed histopathologically in 71.4% of cases (n=25/35). The impact could not be predicted using parameters assumed to be clinically relevant. An oncological benefit of a CE-IOUS adapted surgical approach was demonstrated in patients suffering from HCC and colorectal liver metastases. CONCLUSION: CE-IOUS may significantly increase R0 resection rates and should therefore be used routinely as an additional staging method, especially in complex liver surgery.

13.
Ultraschall Med ; 45(1): 36-46, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37748503

RESUMEN

Dynamic contrast-enhanced ultrasound (DCE-US) is a technique to quantify tissue perfusion based on phase-specific enhancement after the injection of microbubble contrast agents for diagnostic ultrasound. The guidelines of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) published in 2004 and updated in 2008, 2011, and 2020 focused on the use of contrast-enhanced ultrasound (CEUS), including essential technical requirements, training, investigational procedures and steps, guidance regarding image interpretation, established and recommended clinical indications, and safety considerations. However, the quantification of phase-specific enhancement patterns acquired with ultrasound contrast agents (UCAs) is not discussed here. The purpose of this EFSUMB Technical Review is to further establish a basis for the standardization of DCE-US focusing on treatment monitoring in oncology. It provides some recommendations and descriptions as to how to quantify dynamic ultrasound contrast enhancement, and technical explanations for the analysis of time-intensity curves (TICs). This update of the 2012 EFSUMB introduction to DCE-US includes clinical aspects for data collection, analysis, and interpretation that have emerged from recent studies. The current study not only aims to support future work in this research field but also to facilitate a transition to clinical routine use of DCE-US.


Asunto(s)
Medios de Contraste , Neoplasias , Humanos , Ultrasonografía/métodos , Perfusión
14.
Clin Hemorheol Microcirc ; 86(1-2): 89-97, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37574725

RESUMEN

OBJECTIVE: To test and initially describe a new handheld wireless ultrasound technique (TE Air) for clinical use. METHODS: In this pilot study, the new ultrasound device TE Air from Mindray was used to examine the hepatic and renal vessels of healthy volunteers for first impressions. The probe has a sector transducer with a frequency range of 1.8-4.5 MHz. The B-mode and color-coded doppler sonography (CCDS) scanning methods were used. A high-end device from the same company (Resona 9, Mindray) was used as a reference. The results were evaluated using an image rating scale ranging from 0 to 5, with 0 indicating not assessable and 5 indicating without limitations. RESULTS: Altogether, 61 participants (n = 34 female [55.7%], n = 27 male [44.3%]), age range 18-83 years, mean age 37.9±16.5 years) could be adequately studied using TE AIR and the high-end device. With one exception, the image quality score for TE Air never fell below 3 and had a mean/median scored of 4.97/5.00 for the B-mode, 4.92/5.00 for the color flow (CF) mode, and 4.89/5.00 for the pulse wave (PW) mode of the hepatic vein, 4.90/5.00 for the portal vein, 4.11/4.00 for the hepatic artery, and 4.57/5.00 for the renal segmental artery. A significant difference in the assessment of flow measurement of the hepatic artery and renal segmental arteries was found between TE AIR and the high-end device. CONCLUSIONS: TE Air represents a new dimension in point-of-care ultrasound via wireless handheld devices. Especially, its flow measurement ability offers a relevant advantage over other available handheld models. TE Air provides a formally sufficient image quality in terms of diagnostic significance.


Asunto(s)
Vena Porta , Ultrasonografía Doppler en Color , Humanos , Masculino , Femenino , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Proyectos Piloto , Ultrasonografía , Vena Porta/diagnóstico por imagen , Hígado
15.
Clin Hemorheol Microcirc ; 86(1-2): 121-131, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37638426

RESUMEN

AIM: To evaluate the usefulness of handheld ultrasound in comparison with high-end ultrasound for lesion evaluation before and after sclerotherapy in pediatric patients with venous malformations (VMs). MATERIAL AND METHODS: 10 pediatric patients prior to and after sclerotherapy were scanned by an experienced examiner using handheld ultrasound (Vscan AirTM) and high-end ultrasound (LOGIQ E9/E10) as reference. Patients with associated venous thromboses and intralesional aneurysms had been excluded. Results were interpreted independently by two readers in consensus. RESULTS: 10 patients (4-17 years; 10.0±4.32 years; female n = 6, male n = 4) with 10 VMs (4 of the head and neck region, 4 of the upper and 2 of the lower extremities) were examined. 7 phleboliths were detected. The average rating score achieved by the high-end device never was less than 4, by Vscan AirTM never less than 3. An exception was the assessment of AV fistulas. In comparison with the evaluation of variables examined, we found a significant difference between the high-end scanner and the handheld device regarding the achieved image quality. CONCLUSION: Vscan AirTM ultrasound device allows new possibilities for procedure planning and post-procedural control of pediatric patients with VMs.


Asunto(s)
Malformaciones Vasculares , Humanos , Niño , Masculino , Femenino , Malformaciones Vasculares/diagnóstico por imagen , Malformaciones Vasculares/terapia , Ultrasonografía , Escleroterapia/métodos , Venas/diagnóstico por imagen , Cuello , Resultado del Tratamiento , Estudios Retrospectivos
16.
Med Ultrason ; 26(1): 50-62, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37632826

RESUMEN

Improved detection and characterization of common focal liver lesions (FLL) are the main topics of the World Federation for Ultrasound in Medicine and Biology (WFUMB) guidelines on the use of contrast-enhanced ultrasound (CEUS). On stateof-the-art CEUS imaging, to create a library of rare FLL, especially concerning their atypical imaging characteristics, might be helpful for improving clinical diagnostic efficiency. In this review, we aim to summarize the ultrasound and CEUS features of rare benign FLL. Currently there are limited reports and images published.


Asunto(s)
Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/patología , Medios de Contraste , Ultrasonografía/métodos
17.
Clin Hemorheol Microcirc ; 86(3): 313-326, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37927251

RESUMEN

OBJECTIVES: To evaluate the efficacy of the radiomics model based on preoperative B-mode ultrasound (BMUS) and shear wave elastography (SWE) for predicting the occurrence of clinically relevant-postoperative pancreatic fistula (CR-POPF). METHODS: Patients who were scheduled to undergo pancreatectomy were prospectively enrolled and received ultrasound assessment within one week before surgery. The risk factors of POPF (grades B and grades C) were analyzed. Preoperative BMUS images, SWE values of pancreatic lesions and surrounding parenchyma were used to build preoperative prediction radiomics models. Radiomic signatures were extracted and constructed using a minimal Redundancy Maximal Relevance (mRMR) algorithm and an L1 penalized logistic regression. A combined model was built using multivariate regression which incorporated radiomics signatures and clinical data. RESULTS: From January 2020 to November 2021, a total of 147 patients (85 distal pancreatectomies and 62 pancreaticoduodenectomies) were enrolled. During the three-week follow-up after pancreatectomy, the incidence rates of grade B/C POPF were 28.6% (42/147). Radiomic signatures constructed from BMUS of pancreas parenchymal regions (panRS) achieved an area under the receiver operating characteristic curve (AUC) of 0.75, accuracy of 68.7%, sensitivity of 85.7 %, and specificity of 61.9 % in preoperative noninvasive prediction of CR-POPF. The AUC of the radiomics model increased to 0.81 when panRS was used for the prediction of CR-POPF after pancreaticoduodenectomy. CONCLUSIONS: Radiomics model based on ultrasound images was potentially useful for predicting CR-POPF. Patients with high-risk factors should be closely monitored when postoperation.


Asunto(s)
Pancreatectomía , Fístula Pancreática , Humanos , Pancreatectomía/efectos adversos , Fístula Pancreática/etiología , Fístula Pancreática/complicaciones , Radiómica , Páncreas/diagnóstico por imagen , Páncreas/cirugía , Pancreaticoduodenectomía/efectos adversos , Factores de Riesgo , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/patología , Estudios Retrospectivos
18.
Med Ultrason ; 26(3): 284-292, 2024 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-38150699

RESUMEN

The diagnosis or rare mesenchymal malignant lesions of the liver may be a challenge owing to the rarity of the disease and is usually made by histological confirmation. An ultrasound examination with, if required, color Doppler sonography and contrast-enhanced ultrasound, taking into account the clinical background of the patient, may help to focus the differential diagnosis. In this review, we describe the pathological and ultrasound features of several rare mesenchymal malignant liver lesions which include undifferentiated sarcoma of the liver, leiomyosarcoma, angiosarcoma, fibrosarcoma, liposarcoma, and epithelioid hemangioendothelioma.


Asunto(s)
Medios de Contraste , Neoplasias Hepáticas , Ultrasonografía , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Ultrasonografía/métodos , Diagnóstico Diferencial , Guías de Práctica Clínica como Asunto , Hígado/diagnóstico por imagen , Sarcoma/diagnóstico por imagen , Enfermedades Raras/diagnóstico por imagen
19.
J Gastrointestin Liver Dis ; 32(4): 479-487, 2023 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-38147619

RESUMEN

AIMS: To assess the value of using integrated parametric ultrasound software for contrast-enhanced ultrasonography (CEUS) of liver tumors. METHODS: 107 patients with liver tumors were studied. CEUS were performed to detect focal lesions. Parametric images were based on continuous CINE LOOPs, from the early-arterial phase (15 s) to the portal-venous phase (1 min) generated by perfusion software. The evaluations of the parametric images and their dignity for liver lesions were performed independently by an experienced and a less-experienced investigator. Computed tomography, magnetic resonance imaging scans or histological analysis were used as references. RESULTS: High parametric image quality were obtained in all patients. Among the patients, 44% lesions were benign, 56% were malignant. The experienced investigator correctly classified 46 of 47 (98%) as benign, and 60 of 60 (100%) as malignant tumors based on the parametric images. The less-experienced investigator correctly classified 39 of 47 (83%) as benign, and 49 of 60 (82%) malignant tumors, acheaving a high statistical accuracy of 98% with this type of diagnostic. CONCLUSION: Parametric imaging for grading the malignant degree of tumor may be a good complement to existing ultrasound techniques and was particularly helpful for improving the assessments of the less-experienced examiner.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Neoplasias Hepáticas , Ultrasonografía , Humanos , Medios de Contraste , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Perfusión/métodos , Sensibilidad y Especificidad , Ultrasonografía/métodos , Programas Informáticos
20.
Artículo en Inglés | MEDLINE | ID: mdl-37980654

RESUMEN

BACKGROUND: Rapid evolution of ultrasound technology has allowed widespread use of handheld ultrasound devices (HHUDs) for many possible applications. Along with the adult population, the use of HHUDs for Point of Care Ultrasound (POCUS) in pediatric medicine has been increasing over the last few years. However, pediatric-specific literature is still scarce on mobile vascular ultrasound. OBJECTIVE: To evaluate diagnostic capabilities of Vscan Air™ in comparison with high-end ultrasound for the assessment of the internal jugular vein in children and adolescents. METHODS: 42 Internal Jugular Veins (IJVs) of 21 pediatric patients were scanned by an experienced examiner using a WLAN-supported handheld ultrasound device (Vscan Air™) and high-end cart-based ultrasound (LOGIQ E9) as reference. B-Mode and Color-coded Doppler (CCDS) were performed and compared. Image quality was assessed using a score of 0 to 5 and statistically analyzed. Results were interpreted independently by two readers in consensus. RESULTS: 21 patients (2-17 years; mean 11,00±4,5 years; female n = 11, male n = 10) were examined. The rating score never dropped below 3 for both devices. The median score evaluation of B-Mode and CCDS for the high-end device was 5.00, of Vscan Air™ 5.00 for B-Mode and 4.00 for CCDS. A significant difference was shown between the two devices in the evaluation of CCDS. CONCLUSIONS: Vscan Air™ ultrasound device allows sufficient assessability of the IJV in pediatric patients, opening up new possibilities for fast and mobile POCUS of cervical veins and potential guidance of central venous catheter placement.