Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(22)2023 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-38005536

RESUMEN

An automotive 2.1 µm CMOS image sensor has been developed with a full-depth deep trench isolation and an advanced readout circuit technology. To achieve a high dynamic range, we employ a sub-pixel structure featuring a high conversion gain of a large photodiode and a lateral overflow of a small photodiode connected to an in-pixel storage capacitor. With the sensitivity ratio of 10, the expanded dynamic range could reach 120 dB at 85 °C by realizing a low random noise of 0.83 e- and a high overflow capacity of 210 ke-. An over 25 dB signal-to-noise ratio is achieved during HDR image synthesis by increasing the full-well capacity of the small photodiode up to 10,000 e- and suppressing the floating diffusion leakage current at 105 °C.

2.
Sci Rep ; 5: 9610, 2015 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-26043868

RESUMEN

Structural inhomogeneities, such as the wrinkles and ripples within a graphene film after transferring the free-standing graphene layer to a functional substrate, degrade the physical and electrical properties of the corresponding electronic devices. Here, we introduced titanium as a superior adhesion layer for fabricating wrinkle-free graphene films that is highly applicable to flexible and transparent electronic devices. The Ti layer does not influence the electronic performance of the functional substrates. Experimental and theoretical investigations confirm that the strong chemical interactions between Ti and any oxygen atoms unintentionally introduced on/within the graphene are responsible for forming the clean, defect-free graphene layer. Our results accelerate the practical application of graphene-related electronic devices with enhanced functionality. The large-area monolayer graphenes were prepared by a simple attachment of the Ti layer with the multi-layer wrinkle-free graphene films. For the first time, the graphene films were addressed for applications of superior bottom electrode for flexible capacitors instead of the novel metals.

3.
Sci Rep ; 4: 6271, 2014 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-25183360

RESUMEN

Homogeneously distributed zinc nanoparticles (NPs) on the glass substrate were investigated for the transmittance, mechanical durability, and antibacterial effect. The buffered Ti NPs between Zn NPs and glass substrate were studied for an enhancement of the transmittance and mechanical endurance. The Ti NPs buffered Zn NPs showed a high transmittance of approximately 91.5% (at a wavelength of 550 nm) and a strong antibacterial activity for Staphylococcus aureus and Escherichia coli bacteria. The buffered Ti NPs are attractive for an excellent mechanical endurance of the Zn NPs. The Zn NPs did not require the protection layer to prevent the degradation of the performance for both the antibacterial effect and the transmittance.


Asunto(s)
Antibacterianos/química , Antibacterianos/farmacología , Vidrio/química , Nanopartículas del Metal/administración & dosificación , Nanopartículas del Metal/química , Zinc/química , Zinc/farmacología , Escherichia coli/efectos de los fármacos , Staphylococcus aureus/efectos de los fármacos , Titanio/química , Titanio/farmacología
4.
Arthroscopy ; 19(7): 722-31, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12966380

RESUMEN

PURPOSE: Increased stress within a certain limit enhances ligament healing and improves joint function. In this prospective randomized clinical trial, we compared the clinical results of early motion versus conventional immobilization after arthroscopic Bankart repair in a selected patient population. TYPE OF STUDY: Prospective randomized clinical trial. METHODS: We performed an arthroscopic Bankart repair using suture anchors in 62 patients with traumatic recurrent anterior instability of the shoulder. Patients were randomized into 2 groups; group 1 (28 patients; mean age, 28 years) was managed with 3 weeks of immobilization using an abduction sling and conventional rehabilitation program, and group 2 (34 patients; mean age, 29 years) was managed with an accelerated rehabilitation program that consisted of staged range of motion and strengthening exercises from the immediate postoperative day. Selection criteria were nonathletes with recurrent anterior shoulder dislocation and a classic Bankart lesion with a robust labrum limited to 1 cm from the midglenoid notch. The patients were followed up for a mean of 31 months (range, 27 to 45 months; standard deviation, 9 months). Analysis of outcome included pain scores at 6 weeks and at final follow-up evaluation, range of motion, return to activity, recurrence rate, patient satisfaction with each rehabilitation program, and shoulder scores assessed by the American Shoulder and Elbow Surgeons Shoulder Index, the rating system of the University of California at Los Angeles, and another scoring system. RESULTS: The recurrence rate was not different between the 2 groups (P =.842). None of the groups developed recurrent dislocation. Two patients from each group were positive for anterior apprehension signs. Patients who underwent accelerated rehabilitation resumed functional range of motion faster (P <.001) and returned earlier to the functional level of activity (P <.001). Accelerated rehabilitation decreased postoperative pain (P =.013), and more patients were satisfied with this program (P <.001). Shoulder scores, return to activity, pain score, and range of motion were not different between the 2 groups at the final follow-up evaluation (P >.05). CONCLUSIONS: Early mobilization of the operated shoulder after arthroscopic Bankart repair does not increase the recurrence rate in a selected group of patients. Although the final outcomes are approximately the same for both groups, the accelerated rehabilitation program promotes functional recovery and reduces postoperative pain, which allows patients an early return to desired activities.


Asunto(s)
Artroscopía , Inestabilidad de la Articulación/cirugía , Ligamentos/cirugía , Modalidades de Fisioterapia , Luxación del Hombro/cirugía , Articulación del Hombro/cirugía , Adolescente , Adulto , Femenino , Estudios de Seguimiento , Humanos , Inmovilización , Inestabilidad de la Articulación/rehabilitación , Ligamentos/lesiones , Masculino , Dolor Postoperatorio/prevención & control , Estudios Prospectivos , Rango del Movimiento Articular , Recuperación de la Función , Recurrencia , Luxación del Hombro/rehabilitación , Factores de Tiempo , Resultado del Tratamiento
5.
Acta Orthop Scand ; 74(3): 259-63, 2003 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12899544

RESUMEN

24 patients underwent bilateral hip replacement, using the SROM modular system (Depuy Johnson & Johnson, MA, USA) with the porous-coated sleeve in one hip and an HA-coated sleeve in the other. 20 patients were followed for at least 4 years with clinical and radiographic evaluations. We found no difference between the two sides as regards the time of disappearance of thigh pain and hip scores. Radiographs showed a buttress sign in 18 HA-coated and 15 porous coated stems. There were no differences in the serial bone-remodeling pattern around the proximal sleeve and measurement of wear volume between the two groups. In the short- to medium-term, our findings support the view that the hydroxyapatite-coated femoral stem has no advantages over those with porous coating.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Materiales Biocompatibles Revestidos/uso terapéutico , Durapatita/uso terapéutico , Prótesis de Cadera/normas , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Densidad Ósea , Remodelación Ósea , Fosfatos de Calcio , Análisis de Falla de Equipo , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Necrosis de la Cabeza Femoral/fisiopatología , Necrosis de la Cabeza Femoral/cirugía , Estudios de Seguimiento , Marcha , Humanos , Hidroxiapatitas , Persona de Mediana Edad , Oseointegración , Osteoartritis de la Cadera/diagnóstico por imagen , Osteoartritis de la Cadera/fisiopatología , Osteoartritis de la Cadera/cirugía , Dolor Postoperatorio/etiología , Porosidad , Diseño de Prótesis , Falla de Prótesis , Radiografía , Índice de Severidad de la Enfermedad , Propiedades de Superficie , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA