Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Bioelectrochemistry ; 148: 108259, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36179392

RESUMEN

A lactate sensor for lactate sensing using porous laser-induced graphene (LIG) electrodes with an electrodeposited PdCu catalyst was developed in this study. CO2 laser was used to convert the polyimide film surface to multilayered LIG. The morphology and composition of LIG were analyzed through field-emission scanning electron microscopy and Raman spectroscopy, respectively, to confirm that the fabricated LIG electrode was composed of porous and stacked graphene layers. PdCu was electrodeposited on the LIG electrode and lactate oxidase (LOx) was immobilized on the LIG surface to create a LOx/PdCu/LIG structure. According to the Randles-Sevcík equation, the calculated active surface area of the fabricated PdCu/LIG electrode was ∼12.8 mm2, which was larger than the apparent area of PdCu/LIG (1.766 mm2) by a factor of 7.25. The measured sensitivities of the fabricated lactate sensors with the LOx/PdCu/LIG electrode were -51.91 µA/mM·cm2 (0.1-5 mM) and -17.18 µA/mM·cm2 (5-30 mM). The calculated limit of detection was 0.28 µM. The selectivity of the fabricated lactate sensor is excellent toward various potentially interfering materials such as ascorbic acid, uric acid, lactose, sucrose, K+ and Na+.


Asunto(s)
Grafito , Ácido Ascórbico , Dióxido de Carbono , Electrodos , Galvanoplastia , Grafito/química , Ácido Láctico , Lactosa , Rayos Láser , Sacarosa , Ácido Úrico
2.
J Neural Eng ; 11(4): 046023, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25024292

RESUMEN

OBJECTIVE: Epidural electrocorticography (ECoG) activity may be more reliable and stable than single-unit-activity or local field potential. Invasive brain computer interface (BCI) devices are limited by mechanical mismatching and cellular reactive responses due to differences in the elastic modulus and the motion of stiff electrodes. We propose a mesh-shaped electrode to enhance the contactability between surface of dura and electrode. APPROACH: We designed a polyimide (PI) electrode with a mesh pattern for more conformal contact with a curved surface. We compared the contact capability of mesh PI electrodes with conventionally used sheet PI electrode. The electrical properties of the mesh PI electrode were evaluated for four weeks. We recorded the epidural ECoG (eECoG) activity on the surface of rhesus monkey brains while they performed a saccadic task for four months. MAIN RESULTS: The mesh PI electrode showed good contact with the agarose brain surface, as evaluated by visual inspection and signal measurement. It was about 87% accurate in predicting the direction of saccade eye movement. SIGNIFICANCE: Our results indicate that the mesh PI electrode was flexible and good contact on the curved surface and can record eECoG activity maintaining close contact to dura, which was proved by in vivo and in vitro test.


Asunto(s)
Electroencefalografía/instrumentación , Electroencefalografía/métodos , Espacio Epidural/fisiología , Imidas , Microelectrodos , Prótesis Neurales , Polímeros , Animales , Encéfalo/fisiología , Interfaces Cerebro-Computador , Electrodos Implantados , Macaca mulatta , Masculino , Modelos Anatómicos , Desempeño Psicomotor/fisiología , Movimientos Sacádicos/fisiología , Mallas Quirúrgicas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...