Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Intern Med ; 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38462523

RESUMEN

Objective Abdominal ultrasonography (AUS) is used to screen for abdominal diseases owing to its low cost, safety, and accessibility. However, the detection rate of pancreatic disease using AUS is unsatisfactory. We evaluated the visualization area of the pancreas and the efficacy of manipulation techniques for AUS with fusion imaging. Methods Magnetic resonance imaging (MRI) volume data were obtained from 20 healthy volunteers in supine and right lateral positions. The MRI volume data were transferred to an ultrasound machine equipped with a fusion imaging software program. We evaluated the visualization area of the pancreas before and after postural changes using AUS with fusion imaging and assessed the liquid-filled stomach method using 500 ml of de-aerated water in 10 randomly selected volunteers. Patients This study included 20 healthy volunteers (19 men and 1 woman) with a mean age of 33.0 (21-37.5) years old. Results Fusion imaging revealed that the visualization area of the entire pancreas using AUS was 55%, which significantly improved to 75% with a postural change and 90% when using the liquid-filled stomach method (p=0.043). Gastrointestinal gas is the main obstacle for visualization of the pancreas. Conclusion Fusion imaging objectively demonstrated that manipulation techniques can improve pancreatic visualization.

2.
Intern Med ; 56(14): 1931-1935, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28717096

RESUMEN

A 56-year-old woman, without any immunocompromising diseases, was referred to our hospital because of a recurrence of pyogenic spondylitis. Computed tomography revealed multiple osteolytic changes in the whole body. Vertebral magnetic resonance imaging revealed osteomyelitis and spondylitis. Mycobacterium scrofulaceum was detected in sputum cultures, in abscesses from the right knee, and in a subcutaneous forehead abscess. Therefore, the patient was diagnosed with disseminated Mycobacterium scrofulaceum infection. The patient was treated with rifampicin, ethambutol, and clarithromycin, which resulted in symptomatic relief and radiological improvement. We herein report a rare case of disseminated Mycobacterium scrofulaceum infection in an immunocompetent host.


Asunto(s)
Infecciones por Mycobacterium no Tuberculosas/diagnóstico , Mycobacterium scrofulaceum , Antituberculosos/uso terapéutico , Claritromicina/uso terapéutico , Etambutol/uso terapéutico , Femenino , Humanos , Persona de Mediana Edad , Infecciones por Mycobacterium no Tuberculosas/tratamiento farmacológico , Infecciones por Mycobacterium no Tuberculosas/microbiología , Osteomielitis/microbiología , Rifampin/uso terapéutico
3.
Eur Radiol ; 27(11): 4472-4481, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28439654

RESUMEN

OBJECTIVES: In this preliminary study, we examined whether imaging-based phenotypes are associated with reported predictive gene signatures in hepatocellular carcinoma (HCC). METHODS: Thirty-eight patients (M/F 30/8, mean age 61 years) who underwent pre-operative CT or MR imaging before surgery as well as transcriptome profiling were included in this IRB-approved single-centre retrospective study. Eleven qualitative and four quantitative imaging traits (size, enhancement ratios, wash-out ratio, tumour-to-liver contrast ratios) were assessed by three observers and were correlated with 13 previously reported HCC gene signatures using logistic regression analysis. RESULTS: Thirty-nine HCC tumours (mean size 5.7 ± 3.2 cm) were assessed. Significant positive associations were observed between certain imaging traits and gene signatures of aggressive HCC phenotype (G3-Boyault, Proliferation-Chiang profiles, CK19-Villanueva, S1/S2-Hoshida) with odds ratios ranging from 4.44-12.73 (P <0.045). Infiltrative pattern at imaging was significantly associated with signatures of microvascular invasion and aggressive phenotype. Significant but weak associations were also observed between each enhancement ratio and tumour-to-liver contrast ratios and certain gene expression profiles. CONCLUSIONS: This preliminary study demonstrates a correlation between phenotypic imaging traits with gene signatures of aggressive HCC, which warrants further prospective validation to establish imaging-based surrogate markers of molecular phenotypes in HCC. KEY POINTS: • There are associations between imaging and gene signatures of aggressive hepatocellular carcinoma. • Infiltrative type is associated with gene signatures of microvascular invasion and aggressiveness. • Infiltrative type may be a surrogate marker of microvascular invasion gene signature.


Asunto(s)
Carcinoma Hepatocelular/genética , Perfilación de la Expresión Génica/métodos , Neoplasias Hepáticas/genética , Transcriptoma , Anciano , Anciano de 80 o más Años , Biomarcadores , Carcinoma Hepatocelular/patología , Femenino , Humanos , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
4.
Eur J Radiol Open ; 3: 1-7, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27069971

RESUMEN

PURPOSE: To correlate intra voxel incoherent motion (IVIM) diffusion parameters of liver parenchyma and hepatocellular carcinoma (HCC) with degree of liver/tumor enhancement and necrosis; and to assess the diagnostic performance of diffusion parameters vs. enhancement ratios (ER) for prediction of complete tumor necrosis. PATIENTS AND METHODS: In this IRB approved HIPAA compliant study, we included 46 patients with HCC who underwent IVIM diffusion-weighted (DW) MRI in addition to routine sequences at 3.0 T. True diffusion coefficient (D), pseudo-diffusion coefficient (D*), perfusion fraction (PF) and apparent diffusion coefficient (ADC) were quantified in tumors and liver parenchyma. Tumor ER were calculated using contrast-enhanced imaging, and degree of tumor necrosis was assessed using post-contrast image subtraction. IVIM parameters and ER were compared between HCC and background liver and between necrotic and viable tumor components. ROC analysis for prediction of complete tumor necrosis was performed. RESULTS: 79 HCCs were assessed (mean size 2.5 cm). D, PF and ADC were significantly higher in HCC vs. liver (p < 0.0001). There were weak significant negative/positive correlations between D/PF and ER, and significant correlations between D/PF/ADC and tumor necrosis (for D, r 0.452, p < 0.001). Among diffusion parameters, D had the highest area under the curve (AUC 0.811) for predicting complete tumor necrosis. ER outperformed diffusion parameters for prediction of complete tumor necrosis (AUC > 0.95, p < 0.002). CONCLUSION: D has a reasonable diagnostic performance for predicting complete tumor necrosis, however lower than that of contrast-enhanced imaging.

5.
J Hepatol ; 63(6): 1360-7, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26232269

RESUMEN

BACKGROUND & AIMS: The aim of this study was to investigate the feasibility of ablative margin (AM) grading by magnetic resonance imaging (MRI) with Gd-EOB-DTPA administered prior to radiofrequency ablation (RFA), and to identify factors for achieving a sufficient AM and predictors for local tumor progression. METHODS: A total of 124 hepatocellular carcinomas (HCCs) were treated by RFA after Gd-EOB-DTPA administration. MRI and enhanced CT were performed within seven hours and one month after RFA. The AM assessment was categorized using three grades: AM (+), low-intensity area with continuous high-intensity rim; AM zero, low-intensity area with discontinuous high-intensity rim; and AM (-), low-intensity area extends beyond the high-intensity rim. Patients were followed and local tumor progression was observed. RESULTS: AM (+), AM zero, AM (-), and indeterminate were found in 34, 33, 26, and 31 nodules, respectively. The overall agreement rate between MRI and enhanced CT for the diagnosis of AM was 56.8%. The κ coefficient was 0.326 (p<0.001), indicating moderate agreement. Multivariate logistic regression analysis showed that a significant factor for the achievement of AM (+) on MRI was no contiguous vessels. The cumulative local tumor progression rates (0% at 1, 2, and 3 years) in 33 AM (+) nodules were significantly lower than those (3.6%, 11.5%, and 18.3% at 1, 2, and 3 years respectively) in 32 AM zero nodules. A multivariate Cox proportional hazards model identified tumor size as an independent predictor for local tumor progression. CONCLUSION: Gd-EOB-DTPA-MRI enabled an early assessment of RFA effectiveness in the majority ofHCC nodules. Local tumor progression was not detected in AM (+) nodules during the follow-up.


Asunto(s)
Carcinoma Hepatocelular/cirugía , Ablación por Catéter , Neoplasias Hepáticas/cirugía , Anciano , Carcinoma Hepatocelular/patología , Medios de Contraste , Progresión de la Enfermedad , Femenino , Gadolinio DTPA , Humanos , Estimación de Kaplan-Meier , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
6.
Acta Radiol Open ; 4(2): 2047981614561285, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25793110

RESUMEN

BACKGROUND: Gadoxetic acid and gadopentetate dimeglumine are gadolinium-based contrast agents (GBCAs) with an established role in HCC detection and characterization. PURPOSE: To compare gadopentetate dimeglumine and gadoxetic acid-enhanced magnetic resonance imaging (MRI) for image quality and hepatocellular carcinoma (HCC) detection/conspicuity. MATERIAL AND METHODS: In this IRB approved cross-over pilot prospective study, 12 patients (all men; mean age, 56 years) with chronic liver disease at risk of HCC underwent two repeat MRI examinations using gadopentetate dimeglumine and gadoxetic acid (mean interval between studies, 5 days). Two independent observers analyzed images for image quality and HCC detection/conspicuity. Per-lesion sensitivity, positive predictive value, quantitative enhancement, and lesion-to-liver contrast ratio were calculated for both contrast agents. RESULTS: There was no significant difference in image quality scores between both GBCAs (P = 0.3). A total of 20 HCCs were identified with reference standard in 12 patients (mean size 2.6 cm, range, 1.0-5.0 cm). Higher sensitivity was seen for observer 1 for gadoxetic acid-set in comparison with gadopentetate dimeglumine-set (sensitivity increased from 85.7% to 92.8%), while no difference was noted for observer 2 (sensitivity of 78.5%). Lesion conspicuity was significantly higher on hepatobiliary phase (HBP) images compared to arterial phase images with both GBCAs for both observers (P < 0.05). Lesion-to-liver contrast ratios were significantly higher for HBP compared to all dynamic phases for both agents (P < 0.05). CONCLUSION: Our initial experience suggests that gadoxetic acid-set was superior to gadopentetate dimeglumine-set in terms of HCC detection for one observer, with improved lesion conspicuity and liver-to-lesion contrast on HBP images.

7.
J Magn Reson Imaging ; 41(1): 149-56, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24415565

RESUMEN

PURPOSE: To evaluate short-term test-retest and interobserver reproducibility of IVIM (intravoxel incoherent motion) diffusion parameters and ADC (apparent diffusion coefficient) of hepatocellular carcinoma (HCC) and liver parenchyma at 3.0T. MATERIALS AND METHODS: In this prospective Institutional Review Board (IRB)-approved study, 11 patients were scanned twice using a free-breathing single-shot echo-planar-imaging, diffusion-weighted imaging (DWI) sequence using 4 b values (b = 0, 50, 500, 1000 s/mm(2)) and IVIM DWI using 16 b values (0-800 s/mm(2)) at 3.0T. IVIM parameters (D: true diffusion coefficient, D*: pseudodiffusion coefficient, PF: perfusion fraction) and ADC (using 4 b and 16 b) were calculated. Short-term test-retest and interobserver reproducibility of IVIM parameters and ADC were assessed by measuring correlation coefficient, coefficient of variation (CV), and Bland-Altman limits of agreements (BA-LA). RESULTS: Fifteen HCCs were assessed in 10 patients. Reproducibility of IVIM metrics in HCC was poor for D* and PF (mean CV 60.6% and 37.3%, BA-LA: -161.6% to 135.3% and -66.2% to 101.0%, for D* and PF, respectively), good for D and ADC (CV 19.7% and <16%, BA-LA -57.4% to 36.3% and -38.2 to 34.1%, for D and ADC, respectively). Interobserver reproducibility was on the same order of test-retest reproducibility except for PF in HCC. Reproducibility of diffusion parameters was better in liver parenchyma compared to HCC. CONCLUSION: Poor reproducibility of D*/PF and good reproducibility for D/ADC were observed in HCC and liver parenchyma. These findings may have implications for trials using DWI in HCC.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico , Movimiento (Física) , Adulto , Anciano , Medios de Contraste , Gadolinio DTPA , Humanos , Aumento de la Imagen , Hígado/patología , Masculino , Meglumina/análogos & derivados , Persona de Mediana Edad , Variaciones Dependientes del Observador , Compuestos Organometálicos , Estudios Prospectivos , Reproducibilidad de los Resultados
8.
Eur J Radiol ; 83(12): 2109-2113, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25277521

RESUMEN

PURPOSE: To increase diffusion sampling efficiency in intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver by reducing the number of diffusion weightings (b-values). MATERIALS AND METHODS: In this IRB approved HIPAA compliant prospective study, 53 subjects (M/F 38/15, mean age 52 ± 13 y) underwent IVIM DWI at 1.5T using 16 b-values (0-800s/mm(2)), with 14 subjects having repeat exams to assess IVIM parameter reproducibility. A biexponential diffusion model was used to quantify IVIM hepatic parameters (PF: perfusion fraction, D: true diffusion and D*: pseudo diffusion). All possible subsets of the 16 b-values were probed, with number of b values ranging from 4 to 15, and corresponding parameters were quantified for each subset. For each b-value subset, global parameter estimation error was computed against the parameters obtained with all 16 b-values and the subsets providing the lowest error were selected. Interscan estimation error was also evaluated between repeat exams to assess reproducibility of the IVIM technique in the liver. The optimal b-values distribution was selected such that the number of b-values was minimal while keeping parameter estimation error below interscan reproducibility error. RESULTS: As the number of b-values decreased, the estimation error increased for all parameters, reflecting decreased precision of IVIM metrics. Using an optimal set of 4 b-values (0, 15, 150 and 800s/mm(2)), the errors were 6.5, 22.8 and 66.1% for D, PF and D* respectively. These values lie within the range of test-retest reproducibility for the corresponding parameters, with errors of 12.0, 32.3 and 193.8% for D, PF and D* respectively. CONCLUSION: A set of 4 optimized b-values can be used to estimate IVIM parameters in the liver with significantly shorter acquisition time (up to 75%), without substantial degradation of IVIM parameter precision and reproducibility compared to the 16 b-value acquisition used as the reference.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Hepatitis C Crónica/diagnóstico , Hígado/patología , Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Adulto , Anciano , Femenino , Hepatitis C Crónica/patología , Humanos , Masculino , Persona de Mediana Edad , Enfermedad del Hígado Graso no Alcohólico/patología , Estudios Prospectivos , Reproducibilidad de los Resultados
9.
Yonago Acta Med ; 56(1): 7-12, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24031146

RESUMEN

BACKGROUND: Although there are many reports regarding radiation-induced microbleeds, its frequency, relation to dose and latency after radiation are not fully elucidated. The purpose of this study was to evaluate the frequency, latency, patient factors and dose relation of radiation-induced microbleeds after cranial irradiation using phase-sensitive magnetic resonance imaging (PSI) at 3.0 T. METHODS: Retrospective evaluation of 34 patients (age range, 13-78 years; mean, 49 years; follow-up period, 3-169 months; mean 29 months) who had undergone cranial irradiation using magnetic resonance (MR) imaging including PSI was performed. Twenty-three patients received high-dose irradiation (44-60 Gy), and 11 patients received 24-30 Gy whole brain irradiation. When microbleeds were detected on MR imaging in these high-dose irradiation patients, dose distribution maps were reproduced by reviewing the clinical records. Then the irradiated areas were divided into 6 radiation-dose classes: regions > 55 Gy, 45-55 Gy, 35-45 Gy, 25-35 Gy, 15-25 Gy and 5-15 Gy. The frequency of microbleeds in each radiation-dose class was analyzed. RESULTS: Microbleeds were detected in 7 (21%) of 34 patients on T2-weighted imaging, whereas they were detected in 16 (47%) of the 34 patients on PSIs. The frequency of microbleeds was higher than previously reported. The latency of radiation-induced microbleeds after radiation was 3 months to 9 years (mean, 33 months). In high-dose irradiation patients, the frequency of microbleeds significantly was associated with radiation dose. There were no foci that were observed in regions that had received < 25 Gy. CONCLUSION: Radiation-induced microbleeds occurred more frequently in the present study than has been previously reported. PSI can be used to detect these vascular changes earlier than other conventional MR imaging techniques.

10.
Yonago Acta Med ; 56(1): 21-7, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24031148

RESUMEN

BACKGROUND: Cervical disorders in rheumatoid arthritis (RA) patients have been an important problem for a long time. Although the recent progression of the treatment strategies for RA might change the progression of atlantoaxial vertical subluxation (VS) in RA patients, to reveal the risk factors for VS progression should be important at present. Osteoporosis (OP) and RA share the same risk factors. The purposes of this study were to identify the progression of VS in RA, and to evaluate the relationship between the VS development and OP. METHODS: Eighty female patients with RA and 18 female patients with OP were retrospectively analyzed. The RA patients were divided into VS (10 patients) and non-VS groups (70 patients). Morphological parameters on coronal reconstructed computed tomography images were evaluated. Three-dimensional analysis was used to measure volumes and volumetric bone mineral densities (vBMDs) at the upper cervical spine (UCS). RESULTS: The VS group had higher age, longer RA symptom duration, and lower BMD at the lumbar spine compared to the non-VS group. Volumes and vBMDs at the UCS in RA group were greater than those in the OP group. In accordance with VS development, the lateral masses at the UCS became shorter, the C1 facet angle became sharper, and the volumes at the UCS decreased. However, there was no statistically significant relationship between vBMDs at the UCS and the VS development. CONCLUSION: The C1 facet angle became sharper with VS progression. Although 3-dimensional analysis revealed that decreases in the volumes at the UCS were associated with VS development, no significant relationship between OP and the VS development was observed.

11.
J Gastroenterol ; 48(11): 1283-92, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23338488

RESUMEN

BACKGROUND: Our aim was to determine how well ablative margin (AM) grading assessed by magnetic resonance imaging (MRI) with ferucarbotran administered prior to radiofrequency ablation (RFA) predicts local tumor progression in comparison with enhanced computed tomography (CT). METHODS: 101 hepatocellular carcinomas were treated by RFA after ferucarbotran administration. We performed T2*-weighted MRI after 1 week and enhanced CT after 1 month. The assessment was categorized in three grades: AM(+): high-intensity area with continuous low-intensity rim; AM zero: high-intensity area with discontinuous low-intensity rim; and AM(-): high-intensity area extending beyond the low-intensity rim. RESULTS: AM(+), AM zero, AM(-) and indeterminable were found in 47, 36, 8 and 10 nodules, respectively. The overall agreement rate between MRI and enhanced CT for the diagnosis of AM was 71.3%. The κ coefficient was 0.523 (p < 0.001), indicating moderate agreement. Multivariate logistic regression showed that a significant factor for the achievement of AM(+) on MRI was only segment location (odds ratio 5.9, non-segment 4 + 8 vs. segment 4 + 8). The cumulative local tumor progression rates (4.4, 7.6, and 7.6% in 1, 2, and 3 years) in 47 AM(+) nodules were significantly lower than those (13.9, 33.4, and 41.8% in 1, 2, and 3 years) in 36 AM zero nodules. A multivariate Cox proportional hazards model identified contiguous vessels (odds ratio 12.0) and AM(+) on MRI (odds ratio 0.19) as independent factors for local tumor progression. CONCLUSION: AM assessment by MRI using ferucarbotran can predict local tumor progression after RFA and enable early and less invasive diagnosis.


Asunto(s)
Carcinoma Hepatocelular/cirugía , Ablación por Catéter/métodos , Neoplasias Hepáticas/cirugía , Recurrencia Local de Neoplasia/diagnóstico , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/patología , Medios de Contraste , Dextranos , Progresión de la Enfermedad , Femenino , Humanos , Estimación de Kaplan-Meier , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Nanopartículas de Magnetita , Masculino , Persona de Mediana Edad , Neoplasia Residual , Cuidados Posoperatorios/métodos , Pronóstico , Estudios Prospectivos , Tomografía Computarizada por Rayos X
12.
Clin Imaging ; 36(2): 90-7, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22370129
13.
Neuroradiology ; 54(9): 947-55, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22274571

RESUMEN

INTRODUCTION: The clinical differentiation of Parkinson's disease (PD) from multiple system atrophy (MSA) and progressive supranuclear palsy (PSP) may be challenging, especially in their early stages. The aim of this study was to evaluate the utility of apparent diffusion coefficient (ADC) measurement to distinguish among these degenerative disorders. METHODS: Twenty-five MSA, 20 PSP, and 17 PD patients and 18 healthy controls were retrospectively studied. Axial diffusion-weighted and T2-weighted images were obtained using a 3-T MR system. Regions of interest (ROIs) were precisely placed in the midbrain, pons, putamen, globus pallidus, caudate nucleus, thalamus, superior cerebellar peduncle, middle cerebellar peduncle, cerebellar white matter, and cerebellar dentate nucleus, and the regional ADC (rADC) value was calculated in each ROI. RESULTS: In MSA, rADC values in the pons, middle cerebellar peduncle, cerebellar white matter, and cerebellar dentate nucleus were significantly higher than in PSP, PD, and controls. Furthermore, rADC values in the posterior putamen were significantly higher in MSA than in PSP and controls. In PSP, rADC values were significantly higher in the globus pallidus and midbrain than in MSA, PD, and controls. Furthermore, rADC values in the caudate nucleus and superior cerebellar peduncle were significantly higher in PSP than in MSA and controls. In PD, there were no significant differences in the rADC values compared to in MSA, PSP, and controls in all regions. CONCLUSION: Evaluation of rADC values in characteristic lesions in MSA, PSP, and PD by placing ROIs using 3-T systems can provide useful additional information for differentiating these disorders.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Atrofia de Múltiples Sistemas/diagnóstico , Enfermedad de Parkinson/diagnóstico , Parálisis Supranuclear Progresiva/diagnóstico , Anciano , Mapeo Encefálico/métodos , Estudios de Casos y Controles , Diagnóstico Diferencial , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Atrofia de Múltiples Sistemas/patología , Enfermedad de Parkinson/patología , Estudios Retrospectivos , Estadísticas no Paramétricas , Parálisis Supranuclear Progresiva/patología
14.
Eur J Radiol ; 81(7): 1400-4, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21440397

RESUMEN

BACKGROUND AND PURPOSE: Our aim was to investigate whether magnetic resonance imaging (MRI) with ferucarbotran administered prior to radiofrequency ablation could accurately assess ablative margin when compared with enhanced computed tomography (CT) with iodized oil marking. MATERIALS AND METHODS: We enrolled 27 patients with 32 hepatocellular carcinomas in which iodized oil deposits were visible throughout the nodule after transcatheter arterial chemoembolization. For these nodules, radiofrequency ablation was performed after ferucarbotran administration. We then performed T2-weighted MRI after 1 week and enhanced CT after 1 month. T2-weighted MRI demonstrated the ablative margin as a low-intensity rim. We classified the margin into three grades; margin (+): high-intensity area with a continuous low-intensity rim; margin zero: high-intensity area with a discontinuous low-intensity rim; and margin (-): high-intensity area extending beyond the low-intensity rim. RESULTS: In 28 (86%) of 32 nodules, there was agreement between MRI and CT. The overall agreement between for the two modalities in the assessment of ablative margin was good (κ=0.759, 95% confidence interval: 0.480-1.000, p<0.001). In four nodules, ablative margins on MRI were underestimated by one grade compared with CT. CONCLUSION: MRI using ferucarbotran is less invasive and allows earlier assessment than CT. The MRI technique performed similarly to enhanced CT with iodized oil marking in evaluating the ablative margin after radiofrequency ablation.


Asunto(s)
Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/cirugía , Medios de Contraste , Dextranos , Aceite Yodado/administración & dosificación , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/cirugía , Imagen por Resonancia Magnética/métodos , Nanopartículas de Magnetita , Tomografía Computarizada Espiral/métodos , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/diagnóstico por imagen , Quimioembolización Terapéutica/métodos , Epirrubicina/administración & dosificación , Femenino , Humanos , Yopamidol , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
15.
Eur J Radiol ; 81(10): 2730-6, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22137612

RESUMEN

PURPOSE: The aim of this study was to evaluate the feasibility of magnetic resonance imaging (MRI) without a contrast agent to visualize the ablative margin after radiofrequency ablation (RFA) for hepatocellular carcinoma (HCC), compared with enhanced CT. METHODS: Twenty-five HCCs in 19 patients were treated by RFA. T1-weighted MRI was performed before and after RFA, and the signal intensities of the tumors and surrounding liver tissues were measured. Treatment efficacy was assessed based on three grades: margin (+), a continuous high-intensity rim around the index tumor; margin zero, a partially discontinuous high-intensity rim; margin (-), the tumor extends beyond the high-intensity rim. RESULTS: Twelve (86%) of fourteen low-intensity tumors on the pre-MRI were visualized as low-intensity tumors on post-MRI, and the ablative margins were visualized as high-intensity rims. Two (67%) of three high-intensity tumors on pre-MRI were visualized as higher-intensity tumors in the high-intensity ablative margin. Because the signal intensities of tumors and surrounding tissues in 14 tumors that were low- or high-intensity tumors on pre-MRI increased to the same extent, the tumors and ablative margin could be distinguished on post images. In 6 (75%) of the 8 iso-intensity tumors on pre-MRI, the ablative margin and tumor could also not be discriminated on post-MRI. The overall agreement between MRI and CT for the ablative margin was good (κ coefficient=0.716, p=0.00002). CONCLUSION: In 82% of low- or high-intensity tumors on pre-MRI, post-MRI without a contrast agent enabled visualization of the ablative margin as a high-intensity rim, and it was possible to evaluate the ablative margin earlier and easier than with enhanced CT.


Asunto(s)
Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/cirugía , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/cirugía , Hígado/patología , Hígado/cirugía , Imagen por Resonancia Magnética/métodos , Anciano , Anciano de 80 o más Años , Medios de Contraste , Estudios de Factibilidad , Femenino , Hepatectomía/métodos , Humanos , Aumento de la Imagen , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Cirugía Asistida por Computador/métodos , Resultado del Tratamiento
16.
Abdom Imaging ; 36(5): 612-8, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21479805

RESUMEN

OBJECTIVE: The purpose of this study was to investigate the efficacy of 3.0T MR imaging in the assessment of depth of myometrial invasion by endometrial carcinoma. METHODS: Fifty women with histopathologically confirmed endometrial carcinoma underwent preoperative MR imaging at 3.0T. MR imaging findings were compared with microscopic pathologic findings in all cases. On evaluation of MR images and histopathological findings, myometrial invasion was classified as absent (tumor confined to the endometrium), superficial (less than 50% of myometrial thickness), or deep (50% or more of myometrial thickness) by two radiologists. RESULTS: The sensitivity, specificity, and accuracy of the MR imaging in distinguishing no myometrial invasion from myometrial invasion were 95/95, 60/70, and 88/90%, respectively, and no and superficial myometrial invasion from deep myometrial invasion were 88/94, 97/94, and 94/92%, respectively. CONCLUSIONS: In evaluation of the depth of myometrial invasion by endometrial carcinoma, 3.0T MR imaging has a high diagnostic accuracy that is equivalent to that of previously reported 1.5T MR imaging.


Asunto(s)
Neoplasias Endometriales/patología , Imagen por Resonancia Magnética/métodos , Miometrio/patología , Invasividad Neoplásica/patología , Anciano , Biopsia , Medios de Contraste , Neoplasias Endometriales/cirugía , Femenino , Humanos , Meglumina , Persona de Mediana Edad , Miometrio/cirugía , Compuestos Organometálicos , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
17.
Eur J Radiol ; 78(2): 282-6, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21296516

RESUMEN

OBJECTIVES: To evaluate the usefulness of administration of superparamagnetic iron oxide (SPIO) and magnetic resonance (MR) imaging for assessing the efficacy of radiofrequency (RF) liver ablation. MATERIAL AND METHODS: Using a protocol approved by the animal research committee of our university, nine RF liver ablations were performed in three miniature pigs. Six ablations were performed after administration of SPIO in two pigs (group A). Three ablations were performed in the other pig without administration of SPIO (group B). All pigs were sacrificed 4 days after the procedure. Harvested livers were scanned with a 1.5T MR system before and after fixation with 10% buffered formalin, and MR images were precisely compared with histological specimens. RESULTS: There were no histological differences between the two groups. All ablated liver lesions showed coagulation necrosis at the external layer. There were no viable cells inside the coagulation necrosis. All ablated lesions had a hypointense rim on fast low angle shot (FLASH) images. The rims of group A were thicker than those of group B. The rims of group B corresponded histologically to congestion and hemorrhagic necrosis area. The rims of the group A corresponded to hemorrhagic necrosis and coagulation necrosis areas. In group A, the hypointense rim reflected necrotic Kupffer cells that took up SPIO before RF liver ablation. CONCLUSION: Administration of SPIO made it possible to precisely evaluate ablated liver parenchyma by hypointense rim on FLASH images. This method is helpful for the evaluation of safety margin after RF ablation for liver tumors.


Asunto(s)
Ablación por Catéter , Medios de Contraste/administración & dosificación , Dextranos/administración & dosificación , Hígado/cirugía , Imagen por Resonancia Magnética/métodos , Nanopartículas de Magnetita/administración & dosificación , Animales , Femenino , Porcinos , Porcinos Enanos
18.
Eur J Radiol ; 79(1): 108-12, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20116954

RESUMEN

INTRODUCTION: To clarify whether a three-dimensional-gradient echo (3D-GRE) or spin echo (SE) sequence is more useful for evaluating sellar lesions on contrast-enhanced T1-weighted MR imaging at 3.0Tesla (T). METHODS: We retrospectively assessed contrast-enhanced T1-weighted images using 3D-GRE and SE sequences at 3.0T obtained from 33 consecutive patients with clinically suspected sellar lesions. Two experienced neuroradiologists evaluated the images qualitatively in terms of the following criteria: boundary edge of the cavernous sinus and pituitary gland, border of sellar lesions, delineation of the optic nerve and cranial nerves within the cavernous sinus, susceptibility and flow artifacts, and overall image quality. RESULTS: At 3.0T, 3D-GRE provided significantly better images than the SE sequence in terms of the border of sellar lesions, delineation of cranial nerves, and overall image quality; there was no significant difference regarding the boundary edge of the cavernous sinus and pituitary gland. In addition, the 3D-GRE sequence showed fewer pulsation artifacts but more susceptibility artifacts. CONCLUSION: Our results indicate that 3D-GRE is the more suitable sequence for evaluating sellar lesions on contrast-enhanced T1-weighted imaging at 3.0T.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Hipófisis/patología , Silla Turca/patología , Artefactos , Medios de Contraste , Nervios Craneales/anatomía & histología , Femenino , Gadolinio DTPA , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Estadísticas no Paramétricas
19.
Eur J Radiol ; 77(2): 330-4, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19716670

RESUMEN

Our purpose is to clarify the diffusion-weighted (DW) imaging findings of adnexal torsion. We retrospectively analyzed the DW imaging findings in 11 consecutive patients with surgical confirmation of adnexal torsion. We assessed signal intensity of the adnexal mass and fallopian tube thickening, and the location of abnormal signal intensity within the adnexal mass. On DW imaging, thickening of the fallopian tube was apparent as abnormal signal intensity in 8 of 11 patients. Abnormal signal intensity was inhomogeneous in 7 of 8 patients. Abnormal signal intensity on DW imaging was observed in 10 of 11 adnexal masses, and in the walls of 7 out of 8 adnexal cystic lesions. In adnexal torsion, DW imaging showed abnormal signal intensity in the thickened fallopian tube and in the wall of cystic ovarian lesions. These findings would be feasible to diagnose adnexal torsion.


Asunto(s)
Enfermedades de los Anexos/patología , Imagen de Difusión por Resonancia Magnética/métodos , Anomalía Torsional/patología , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
20.
J Comput Assist Tomogr ; 34(3): 377-9, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20498539

RESUMEN

We demonstrated 2 cases of uterine endometrial stromal sarcoma with emphasis on diffusion-weighted imaging. The tumors showed high signal intensity, and their tumor venous thrombi were clearly depicted on diffusion-weighted imaging. Diffusion-weighted imaging is a useful method not only for diagnosis of endometrial stromal sarcoma but also for preoperative planning.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Sarcoma Estromático Endometrial/diagnóstico , Neoplasias Uterinas/diagnóstico , Adulto , Femenino , Humanos , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...