Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
J Artif Organs ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38916826

RESUMEN

Biological valves are becoming more frequently used in aortic valve replacement. While several reports have evaluated the performance of biological valves, echocardiography studies during exercise stress remain scarce. Furthermore, no current reports compare rate changes in the aortic valve area of biological valves under increased exercise load. Here, we performed exercise stress echocardiography in patients after AVR with Trifecta or Inspiris valves and compared the rates of change in aortic valve areas (AVA). In addition, hydrodynamic analysis at rest was conducted with four-dimensional flow magnetic resonance imaging (4D-flow MRI). Exercise stress echocardiography was performed in seven Trifecta and seven Inspiris patients who underwent AVR at our hospital while 4D flow MRI was performed in all but two Trifecta cases. Comparing the percentage change in AVA when loaded to 25 W versus at rest, Trifecta was greater than Inspiris (28.7 ± 36.0 vs - 0.8 ± 12.4%). The smaller AVA at rest was considered causative for this. Meanwhile, Trifecta systolic energy loss in the prosthetic valve segment on 4D-flow MRI (97.5 ± 35.9 vs 52.7 ± 25.3 mW) was higher than Inspiris. The opening of the Trifecta valve was considered to be restricted at rest and this may reflect the current reports of early valve degradation requiring reoperation. Taken together, we observed that the Trifecta design may promote faster wear due to higher valve stress.

2.
Kyobu Geka ; 77(2): 141-145, 2024 Feb.
Artículo en Japonés | MEDLINE | ID: mdl-38459864

RESUMEN

A 74-year-old woman had been on hemodialysis for about 2 months using a short-term indwelling dialysis catheter due to chronic kidney disease. A 20 mm-diameter left atrial neoplastic lesion was noted during a screening echocardiogram performed at the time of induction of hemodialysis. The lesion rapidly increased to 30 mm 2 months later and was referred to our hospital for surgical resection. Under cardiopulmonary bypass and cardiac arrest, tumor resection was performed. Although the lesion was myxomatous with a thin stalk on the left atrial ceiling, the pathological diagnosis was thrombus. After the initiation of anticoagulation, the patient was discharged.


Asunto(s)
Apéndice Atrial , Trombosis , Femenino , Humanos , Anciano , Trombosis/diagnóstico por imagen , Trombosis/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Ecocardiografía
3.
Kyobu Geka ; 76(11): 978-981, 2023 Oct.
Artículo en Japonés | MEDLINE | ID: mdl-38056960

RESUMEN

A pulmonary arteriovenous fistula (PAVF) is a direct abnormal connection between the pulmonary artery and pulmonary vein, lacking capillary tissue. On the other hand, a pulmonary venous aneurysm (PVA) is a localized dilation and aneurysmal formation in the pulmonary vein without reflux issues. Treatment approaches for PAVF and PVA differ, considering surgery or catheter embolization for PAVF due to the risk of cerebral infarction or rupture caused by the abnormal shunt. PVA cases, being rare in rupture and embolism, are usually recommended for observation. Therefore, distinguishing between these two conditions is crucial. This article presents a case where both PVA and PAVF were present, necessitating a differential diagnosis.


Asunto(s)
Aneurisma , Venas Pulmonares , Humanos , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Diagnóstico Diferencial , Aneurisma/diagnóstico por imagen , Aneurisma/cirugía
4.
Kyobu Geka ; 76(12): 1030-1033, 2023 Nov.
Artículo en Japonés | MEDLINE | ID: mdl-38057982

RESUMEN

A 64-year-old female with a diagnosis of Crawford typeⅡ thoracoabdominal aortic aneurysm( TAAA) including enlargement of the ascending aorta underwent a staged hybrid repair including visceral artery debranching thoracic endovascular aortic repair( TEVAR). First, total arch replacement with elephant trunk method was performed, followed by TEVAR for the descending thoracic aorta, and finally visceral artery debranching TEVAR for the thoracoabdominal aorta. Complications such as spinal cord infarction did not occur throughout the procedure. Surgical repair of Crawford typeⅡ TAAA involves a wide range of treatment and is highly invasive, requiring ingenuity in terms of preventing complications such as spinal cord infarction. Hybrid repair including visceral artery debranching TEVAR may be an effective treatment modality for complex aortic lesions including TAAA, but requires careful follow-up including remote complications.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Femenino , Humanos , Persona de Mediana Edad , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/métodos , Resultado del Tratamiento , Infarto , Procedimientos Endovasculares/métodos , Estudios Retrospectivos , Prótesis Vascular , Stents
5.
Kyobu Geka ; 76(2): 136-139, 2023 Feb.
Artículo en Japonés | MEDLINE | ID: mdl-36731848

RESUMEN

A 42-year-old woman with dysphagia was referred to our hospital. Computed tomography (CT) revealed Kommerell diverticulum( KD) associated with right aortic arch( RAA) and aberrant left subclavian artery (ALSCA). We performed total arch replacement (TAR) using a frozen elephant trunk (FET) technique. We ligated ALSCA at the distal portion of the KD after perfusing from a 8 mm tubular graft from left axillar artery. We inserted a FET from the ascending aorta to avoid locating the nonstented portion at the steep-angled site of RAA. Postoperatively dysphagia disappeared and CT scan showed complete exclusion of KD without leakage of the stent graft and successful reconstruction of the arch. The TAR and FET technique is an effective procedure for KD with RAA and ALSCA.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Trastornos de Deglución , Divertículo , Cardiopatías Congénitas , Femenino , Humanos , Adulto , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Trastornos de Deglución/cirugía , Arteria Subclavia/diagnóstico por imagen , Arteria Subclavia/cirugía , Cardiopatías Congénitas/cirugía , Implantación de Prótesis Vascular/métodos , Divertículo/diagnóstico por imagen , Divertículo/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía
6.
Kyobu Geka ; 75(5): 323-327, 2022 May.
Artículo en Japonés | MEDLINE | ID: mdl-35474193

RESUMEN

722 patients who returned to the intensive care unit( ICU) after completing the cardiac surgery and closing the median sternotomy from Jan 2010 to Feb 2021 at our hospital were divided into 3 groups according to the different sternal closures. Sternum was fixed with 6 wires alone in group A (n=333), with 2 absorbable plates and 6 wires in group B( n=259) or with 3 titanium plates with 20 screws and 4 wires in group C (n=130). Background characteristics were not different between the 3 groups. Total number of 3 complications (postsurgical bleeding, mediastinitis and delayed cardiac tamponade) was significantly less in group B and C than group A. Among them postsurgical bleeding needed hemostasis surgery was significantly less in group C than in group A. Surgical nor hospital mortality were not significantly different in 3 groups. Postsurgical complications were significantly less when the sternum closure was fixed with plates( absorbable, not absorbable).


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Mediastinitis , Hilos Ortopédicos , Procedimientos Quirúrgicos Cardíacos/métodos , Humanos , Esternotomía , Esternón/cirugía
7.
Gen Thorac Cardiovasc Surg ; 70(3): 292-294, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35038125

RESUMEN

Reports of early and catastrophic acute structural valve deterioration (SVD) in Trifecta valve (Abbott, St Paul, MN, USA) with multiple leaflet detachment are rare. We encountered two cases of early SVD in Trifecta valve with tears on two leaflets. Both cases presented with acute heart failure because of aortic insufficiency, and underwent redo aortic valve replacement; one patient died due to multiple organ failure caused by cardiogenic shock. Durability issues with the Trifecta valves; thus, necessitates long-term vigilance in aortic replacement patients.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Diseño de Prótesis , Falla de Prótesis
8.
Minim Invasive Ther Allied Technol ; 30(2): 120-123, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31663409

RESUMEN

An 83-year-old woman who had undergone total arch replacement for a thoracic aortic aneurysm seven years prior experienced concurrent rupture of second and third branch anastomotic pseudoaneurysms. A stent graft was initially deployed across the pseudoaneurysm from the third branch to the left subclavian artery. Following the left axillary and left carotid arterial bypass, the origin of the second branch was embolized with metallic coils. As a result, both anastomotic pseudoaneurysms were undetectable by both completion angiogram and postoperative CT. By combining surgical and endovascular procedures, ruptured anastomotic pseudoaneurysms after total arch replacement can be repaired without a risky resternotomy.


Asunto(s)
Aneurisma Falso , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano de 80 o más Años , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Femenino , Humanos , Stents , Resultado del Tratamiento
9.
J Card Surg ; 34(9): 877-879, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31269268

RESUMEN

A 57-year old male with a dual-chamber pacemaker and 40-year history of hemodialysis and autoinflammatory disease developed a large, 35 × 35 mm intracardiac vegetation on the right ventricular pacing lead. As this mass was large enough to occlude the tricuspid valve orifice, transvenous lead extraction was deemed unsuitable. Instead, an urgent surgical extraction of the whole pacemaker system, including leads and vegetation, was conducted under cardiopulmonary bypass. In light of a high risk of recurrent blood infection, a new dual-chamber pacing system was then immediately re-established using epicardial pacing leads on the right atrium and ventricle instead of transvenous electrodes. This case of a rare, giant intracardiac lead vegetation lacked most known causal factors, except for renal failure, but a possibly immunosuppressed cardiac microenvironment due to long-term steroid therapy may have been an important influencing factor.


Asunto(s)
Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/métodos , Puente Cardiopulmonar/métodos , Remoción de Dispositivos/métodos , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Estafilocócicas/cirugía , Ecocardiografía , Ventrículos Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Marcapaso Artificial/microbiología , Pericardio , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/etiología , Reimplantación/métodos , Infecciones Estafilocócicas/diagnóstico , Infecciones Estafilocócicas/microbiología , Staphylococcus epidermidis/aislamiento & purificación
10.
J Cardiothorac Surg ; 11: 40, 2016 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-27025338

RESUMEN

BACKGROUND: Pannus formation may disturb the leaflet movement of the prosthetic valve. CASE PRESENTATION: A 61-year-old woman presented with exertional dyspnea. She had undergone mitral valve replacement with a bioprosthetic valve 31 years ago, which was replaced with a tilting disc valve 22 years ago. The present laboratory findings revealed hemolytic anemia. Echocardiography showed an increased mean pressure gradient through the mitral valve and moderate to severe regurgitation around the minor orifice of the tilting disc valve. She therefore underwent a third operation. Pannus formation was found on the prosthetic valve ring, but it did not obliterate the prosthetic valve orifice. After removing the valve, the posterior wall of the left ventricle was seen to be associated with thickened endocardium. A bileaflet valve was implanted. Postoperative echocardiography showed that the implanted valve functioned well. CONCLUSIONS: Nonstructural dysfunction of the mechanical heart valve might occur long after operation. These changes are particularly observed with a tilting disc valve.


Asunto(s)
Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Falla de Prótesis , Disnea/etiología , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/patología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/patología , Factores de Tiempo , Ultrasonografía
11.
Acute Med Surg ; 3(4): 364-368, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28163921

RESUMEN

CASE: A 26-year-old woman who had congenital aortic valve stenosis presented with exertional dyspnea. She had undergone percutaneous balloon aortic valvuloplasty 12 years previously at the age of 14. When she was 20 years old, she delivered a neonate by elective cesarean section at the 31st week of gestation because the mean pressure between the left ventricle and the ascending aorta was 52 mmHg. OUTCOME: She successfully underwent aortic valve replacement with a bioprosthetic valve combined with replacement of the ascending aorta in order to make the next pregnancy possible. CONCLUSION: The long-term prognosis of percutaneous balloon aortic valvuloplasty might be acceptable for some patients, even though this procedure is associated with the possibility of secondary interventions.

12.
Kyobu Geka ; 68(11): 907-11, 2015 Nov.
Artículo en Japonés | MEDLINE | ID: mdl-26469256

RESUMEN

Between 2003 and 2014, at Jichi Medical University Hospital, 11 patients with prosthetic valve endocarditis (PVE) underwent re-operation. There was 1 in-hospital death and 2 late deaths. The cause of death was cirrhosis, heart failure and sepsis, respectively. Emergency surgery, previous double valve replacement (DVR) and Staphylococcus infection were common risk factors for all 3 cases. Two cases of patients that survived who underwent mitral valve replacement (MVR) and DVR for PVE after DVR were treated with multiple antibiotic courses for bacteremia associated with hemodialysis and colon cancer. One patient who underwent DVR after mitral valve plasty which was complicated with cerebral hemorrhage, had survived and was discharged. Of the aortic PVE patients, 2 cases of aortic valve replacement (AVR) using a mechanical valve, 1 case of aortic root replacement (ARR) using a mechanical valve, and 1 ARR using the homograft, were considered cured and never relapsed. A patient with aortic PVE, who underwent AVR after cesarean section for heart failure in birth period, has received ARR twice with the mechanical valve for recurrent pseudo-aneurysm of the left ventricular outflow tract. Since hemodialysis and colon cancer is a risk factor for recurrent PVE, it is necessary to consider the long-term administration of antibiotics after surgery.


Asunto(s)
Endocarditis Bacteriana/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Adulto , Anciano , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Reoperación , Resultado del Tratamiento
13.
Clin Case Rep ; 2(5): 180-2, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25614806

RESUMEN

KEY CLINICAL MESSAGE: The implanted first-generation Björk-Shiley valve in our patient was functioning well before aortic surgery, but we replaced the valve because we confirmed disc erosion 39 years after implantation during the surgery. We judged that the implanted valve was no longer capable of maintaining the patient's life.

14.
Gen Thorac Cardiovasc Surg ; 61(5): 274-9, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23404312

RESUMEN

OBJECTIVE: Patient-prosthesis mismatch (PPM) may affect clinical outcomes in patients with aortic valve replacement (AVR). We retrospectively examined the PPM in patients with isolated AVR in the Japan Adult Cardiovascular Surgery Database (JACVSD). METHODS: We examined all patients with isolated AVR between January 1, 2008 and December 31, 2009. The JACVSD data collection form has a total of 255 variables. We defined PPM as an effective orifice area index of ≤ 0.85 m(2)/cm(2). RESULTS: PPM was observed in 306 of 3,609 cases analyzed, PPM rate was 8.5 %. Body surface area was larger and body mass index was higher in the PPM group than the non-PPM group (P < 0.001). Patients with PPM were older (P = 0.001) and had a higher prevalence of diabetes (P = 0.004), dyslipidemia (P < 0.001), hypertension (P < 0.001), cerebrovascular disease (P = 0.031), old myocardial infarction (P = 0.006), previous percutaneous coronary artery intervention (P = 0.001), coronary artery disease (P = 0.018), and aortic valve stenosis (P < 0.001). Perioperative blood transfusion (P < 0.001) and dialysis (P = 0.005) were more frequent in the PPM group. Postoperative ventilation (P = 0.004) and intensive care unit stay (P = 0.004) were significantly longer in the PPM group. CONCLUSIONS: Age, aortic valve stenosis, dyslipidemia, hypertension, old myocardial infarction, previous percutaneous coronary artery intervention, diabetes mellitus, cerebrovascular disease, and high body mass index were the risk factors for PPM. PPM was not an independent risk factor for short-term mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anatomía & histología , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Adulto , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Índice de Masa Corporal , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/estadística & datos numéricos , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Japón , Masculino , Persona de Mediana Edad , Valores de Referencia , Diálisis Renal , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia
15.
Kyobu Geka ; 65(4): 297-300, 2012 Apr.
Artículo en Japonés | MEDLINE | ID: mdl-22485033

RESUMEN

Between December 2005 and November 2011, 11 patients with mitral valve regurgitation (MVR) resulting from native valve endocarditis underwent mitral valve plasty (MVP). These patients were aged 44.4 ± 11.3 years. The mean follow-up period of the patients was 3.1 ± 0.63 years. Five patients were men. Emergency or urgent surgery was required in 5 patients. Three patients were categorized as New York Heart Association( NYHA) functional class IV. Infection of the mitral valve, occurred in the anterior leaflet in 3 patients, the posterior leaflet in 5 patients, and the anterior-posterior leaflet in 3 patients. Nine patients had a resection suture technique. One patient had chordae replacement with expanded polytetrafluoroethylene (ePTFE), and 1 patient had replacement using the pericardium. All patients received ring annuloplasty with a partial flexible ring. After surgery, all patients were categorized as NYHA functional class I. There were no valve associated complications, no hospital deaths, no late deaths, and no reoperations. We conclude that MVP is an effective treatment for active infective endocarditis( AIE) with mitral regurgitation.


Asunto(s)
Endocarditis/cirugía , Válvula Mitral/cirugía , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/etiología
16.
Kyobu Geka ; 65(3): 245-8, 2012 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-22374603

RESUMEN

We performed redo-off-pump coronary artery bypass grafting( OPCAB) via a left thoracotomy using the PAS-Port system for proximal vein graft anastomoses in a patient with posterolateral myocardial ischemia. The patient was a 76-year-old man who had undergone coronary artery bypass grafting (CABG)[ left internal thoracic artery( LITA)-left anterior descending artery( LAD), saphenous vein graft(SVG)-posterior descending artery( 4PD), and SVG-postero-lateral branch( PL)] 14 years previously. Coronary angiogram showed that the LITA-LAD graft was patent but that the SVG-PL, left main trunk( LMT) and proximal right coronary artery(RCA) were occluded, and that there were 90% stenoses of LAD #7 and SVG-4PD anastomotic site. With catheter intervention therapy, stenosis of the SVG-#4PD was dilated. We then performed revascularization from the descending aorta to the second diagonal (D2) and PL with a saphenous vein graft via left thoracotomy using off-pump technique. To avoid descending aortic clamping, we used the PAS-Port system for proximal anastomosis. The postoperative course was uneventful and the patient was discharged on postoperative day 28. A redo-CABG is thought to be with high risk. Our procedure, however is safe and useful and can be an option for redo-CABG in the posterolateral area.


Asunto(s)
Puente de Arteria Coronaria Off-Pump/métodos , Toracotomía/métodos , Anciano , Aorta Torácica , Humanos , Masculino , Isquemia Miocárdica/cirugía , Reoperación
17.
Gen Thorac Cardiovasc Surg ; 59(10): 709-11, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21984140

RESUMEN

We experienced a case with a remnant of a fractured guidewire in the coronary artery. Surgical removal of the total wire by manual traction was unsuccessful. The wire was then cut near the right coronary orifice, and its proximal portion was removed. Cardiac interventionists should recognize that percutaneous coronary intervention is associated with the risk of various cardiovascular accidents. Patients should be informed of such risks.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/terapia , Remoción de Dispositivos , Lesiones Cardíacas/cirugía , Lesiones del Sistema Vascular/cirugía , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Cineangiografía , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/lesiones , Vasos Coronarios/cirugía , Falla de Equipo , Femenino , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Humanos , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología
18.
Kyobu Geka ; 64(10): 887-93, 2011 Sep.
Artículo en Japonés | MEDLINE | ID: mdl-21899124

RESUMEN

A 49-year-old man with asymptomatic chronic aneurysmal dissection was admitted to our hospital. He had undergone ascending aortic replacement for type A aortic dissection 7 months before. We performed descending aortic replacement for chronic aneurysmal dissection. Renal dysfunction appeared 1 day after the operation. Contrast-enhanced computed tomography indicated that the true lumen was severely compressed by a false lumen, and that the origins of the renal artery were occluded. We performed emergency endovascular stent placement to dilate the true lumen. Immediately after this procedure, renal ischemia improved. The postoperative course was uneventful. An endovascular approach using bare stent can be a treatment option that is less invasive and prompter for a patient with renal ischemia resulting from aortic dissection.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Prótesis Vascular , Obstrucción de la Arteria Renal/terapia , Stents , Urgencias Médicas , Humanos , Isquemia/etiología , Isquemia/terapia , Riñón , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Obstrucción de la Arteria Renal/etiología
19.
Gen Thorac Cardiovasc Surg ; 59(6): 433-5, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21674313

RESUMEN

Cloth-covered Starr-Edwards caged ball valves implanted in the aortic and mitral valve positions for 39 years were extracted. Both showed valve dysfunction resulting from pannus overgrowth. The metal cages of the Starr-Edwards valves were covered with worn cloth. This case indicates the extended durability of Starr-Edwards valves and the importance of the design and materials of prosthetic heart valves to avoid pannus overgrowth and prosthetic valve abrasion.


Asunto(s)
Válvula Aórtica/cirugía , Materiales Biocompatibles Revestidos , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Anciano , Ecocardiografía , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Humanos , Diseño de Prótesis , Factores de Tiempo
20.
J Cardiol ; 49(4): 199-203, 2007 Apr.
Artículo en Japonés | MEDLINE | ID: mdl-17460881

RESUMEN

A 60-year-old female was admitted to our hospital for further examination of heart murmur. Chest radiography revealed cardiomegaly and pulmonary congestion. Two-dimensional echocardiography showed a mobile and pedunculated mass, approximately 20 mm in diameter, attached to the right ventricular outflow tract, and perimembranous ventricular septal defect. Cardiac catheterization and blood sampling were performed, which showed a pulmonary to systemic flow ratio of 3.70. She underwent surgical excision of the tumor, ventricular septal defect patch suture and tricuspid annuloplasty. Histological examination confirmed papillary fibroelastoma. The predominant location of papillary fibroelastoma is the valvular surface. This very rare case of papillary fibroelastoma was located in the right ventricular outflow tract.


Asunto(s)
Ecocardiografía Transesofágica , Fibroma/cirugía , Neoplasias Cardíacas/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Fibroma/diagnóstico por imagen , Fibroma/etiología , Neoplasias Cardíacas/diagnóstico por imagen , Neoplasias Cardíacas/etiología , Defectos del Tabique Interventricular/complicaciones , Defectos del Tabique Interventricular/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...