Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Prosthodont Res ; 68(2): 336-346, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-37612075

RESUMEN

PURPOSE: This study aims to develop a numerical prediction method for the average and standard deviation values of the largely varied fatigue life of additively manufactured commercially pure titanium (CPTi grade 2) clasps. Accordingly, the proposed method is validated by applying it to clasps of different shapes. METHODS: The Smith-Watson-Topper (SWT) equation and finite element analysis (FEA) were used to predict the average fatigue life. The variability was expressed by a 95% reliability range envelope based on the experimentally determined standard deviation. RESULTS: When predicting the average fatigue life, the previously determined fatigue parameters implemented in the SWT equation were found to be useful after conducting fatigue tests using a displacement-controlled fatigue testing machine. The standard deviation with respect to stroke and fatigue life was determined for each clasp type to predict variability. The proposed prediction method effectively covered the experimental data. Subsequently, the prediction method was applied to clasps of different shapes and validated through fatigue tests using 22 specimens. Finally, the fracture surface was observed using scanning electron microscopy (SEM). Many manufacturing process-induced defects were observed; however, only the surface defects where the maximum tensile stress occurred were crucial. CONCLUSIONS: It was confirmed that the fatigue life of additively manufactured pure titanium parts is predictable before the manufacturing process considering its variability by performing only static elasto-plastic FEA. This outcome contributes to the quality assurance of patient-specific clasps without any experimental investigation, reducing total costs and response time.


Asunto(s)
Aleaciones de Cromo , Dentadura Parcial Removible , Humanos , Titanio , Reproducibilidad de los Resultados , Abrazadera Dental , Ensayo de Materiales
2.
Chem Asian J ; 19(4): e202300968, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38050920

RESUMEN

Three-coordinated chlorogermylenes of the type [Ph2 P(RN)2 ]GeCl (3: R=t Bu; 4: R=Dip=2,6-i Pr2 C6 H3 ), which bear an N,N-substituted iminophosphonamide ligand, were synthesized. The coordination behavior of 3 and 4 toward rhodium(I) complex was investigated. When 3 was treated with 1/2 of an equivalent of [RhCl(cod)]2 (cod=1,5-cyclooctadiene), the corresponding chlorogermylene-Rh(I) complex 5 was obtained as orange crystals. In contrast, the reaction of 4 with a half equivalent of [RhCl(cod)]2 under a CO atmosphere resulted in the formation of a five-membered germarhodacycle 7. Compounds 3, 4, 5, and 7 were characterized using NMR spectroscopies and single-crystal X-ray diffraction. Complex 5 can be employed as a catalyst for the hydrosilylation and hydroboration reactions of diphenylacetylene, thus demonstrating the utility of germylene ligands comparable to those of NHCs in the major transition metal catalytic processes.

3.
J Prosthodont Res ; 67(4): 626-632, 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37032073

RESUMEN

PURPOSE: In this study, the fatigue properties of additively manufactured titanium clasps were compared with those of commercially pure titanium (CPTi) and Ti-6Al-4V (Ti64), manufactured using laser powder-bed fusion. METHODS: Fourteen specimens of each material were tested under the cyclic condition at 1 Hz with applied maximum strokes ranging from 0.2 to 0.5 mm, using a small stroke fatigue testing machine. A numerical approach using finite element analysis (FEA) was also developed to predict the fatigue life of the clasps. RESULTS: The results showed that although no significant differences were observed between the two materials when a stroke larger than 0.35 mm was applied, CPTi had a better fatigue life under a stroke smaller than 0.33 mm. The distributions of the maximum principal stress in the FEA and the fractured position in the experiment were in good agreement. CONCLUSIONS: Using a design of the clasp of the present study, the advantage of the CPTi clasp in its fatigue life under a stroke smaller than 0.33 mm was revealed experimentally. Furthermore, the numerical approach using FEA employing calibrated parameters for the Smith-Watson-Topper method are presented. Under the limitations of the aforementioned clasp design, the establishment of a numerical method enabled us to predict the fatigue life and ensure the quality of the design phase before manufacturing.


Asunto(s)
Aleaciones , Accidente Cerebrovascular , Humanos , Titanio , Polvos , Abrazadera Dental , Rayos Láser , Ensayo de Materiales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...