Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(17)2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39275624

RESUMEN

Low-cost, portable devices capable of accurate physiological measurements are attractive tools for coaches, athletes, and practitioners. The purpose of this study was primarily to establish the validity and reliability of Movesense HR+ ECG measurements compared to the criterion three-lead ECG, and secondarily, to test the industry leader Garmin HRM. Twenty-one healthy adults participated in running and cycling incremental test protocols to exhaustion, both with rest before and after. Movesense HR+ demonstrated consistent and accurate R-peak detection, with an overall sensitivity of 99.7% and precision of 99.6% compared to the criterion; Garmin HRM sensitivity and precision were 84.7% and 87.7%, respectively. Bland-Altman analysis compared to the criterion indicated mean differences (SD) in RR' intervals of 0.23 (22.3) ms for Movesense HR+ at rest and 0.38 (18.7) ms during the incremental test. The mean difference for Garmin HRM-Pro at rest was -8.5 (111.5) ms and 27.7 (128.7) ms for the incremental test. The incremental test correlation was very strong (r = 0.98) between Movesense HR+ and criterion, and moderate (r = 0.66) for Garmin HRM-Pro. This study developed a robust peak detection algorithm and data collection protocol for Movesense HR+ and established its validity and reliability for ECG measurement.


Asunto(s)
Electrocardiografía , Carrera , Humanos , Masculino , Adulto , Electrocardiografía/métodos , Carrera/fisiología , Femenino , Frecuencia Cardíaca/fisiología , Reproducibilidad de los Resultados , Ciclismo/fisiología , Prueba de Esfuerzo/métodos , Adulto Joven
2.
Sensors (Basel) ; 22(24)2022 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-36560134

RESUMEN

BACKGROUND: Inertial measurement units (IMUs) offer the possibility to capture the lower body motions of players of outdoor team sports. However, various sources of error are present when using IMUs: the definition of the body frames, the soft tissue artefact (STA) and the orientation filter. Methods to minimize these errors are currently being used without knowing their exact influence on the various sources of errors. The goal of this study was to present a method to quantify each of the sources of error of an IMU separately. METHODS: An optoelectronic system was used as a gold standard. Rigid marker clusters (RMCs) were designed to construct a rigid connection between the IMU and four markers. This allowed for the separate quantification of each of the sources of error. Ten subjects performed nine different football-specific movements, varying both in the type of movement, and in movement intensity. RESULTS: The error of the definition of the body frames (11.3-18.7 deg RMSD), the STA (3.8-9.1 deg RMSD) and the error of the orientation filter (3.0-12.7 deg RMSD) were all quantified separately for each body segment. CONCLUSIONS: The error sources of IMU-based motion analysis were quantified separately. This allows future studies to quantify and optimize the effects of error reduction techniques.


Asunto(s)
Proyectos de Investigación , Deportes , Humanos , Fenómenos Biomecánicos , Movimiento , Movimiento (Física)
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...