Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Ann Nucl Cardiol ; 9(1): 33-39, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38058574

RESUMEN

Background: Myocardial blood flow quantification (MBF) is one of the distinctive features for cardiac positron emission tomography. The MBF calculation is mostly obtained by estimating the input function from the time activity curve in dynamic scan. However, there is a substantial risk of count-loss because the high radioactivity pass through the left ventricular (LV) cavity within a short period. We aimed to determine the optimal intraventricular activity using the noise equivalent count rate (NECR) analysis with simplified phantom model. Methods: Positron emission tomography computed tomography scanner with LYSO crystal and time of flight was used for phantom study. 150 MBq/mL of 13N was filled in 10 mL of syringe, placed in neck phantom to imitate end-systolic small LV. 3D list-mode acquisition was repeatedly performed along radioactive decay. Net true and random count rate were calculated and compared to the theoretical activity in the syringe. NECR curve analysis was used to determine the optimal radioactive concentration. Result: The attenuation curves showed good correlation to the theoretical activity between 20 to 370, and 370 to 740 MBq (r2=1.0 ± 0.0001, p<0.0001; r2=0.99 ± 0.0001, p<0.0001 for 20 to 370, and 370 to 740, respectively), while did not over 740 MBq (p=0.62). NECR analysis revealed that the peak rate was at 2.9 Mcps, there at the true counts were significantly suppressed. The optimal radioactive concentration was determined as 36 MBq/mL. Conclusion: Simulative analysis for high-dose of 13N using the phantom imitating small LV confirmed that the risk of count-loss was increased. The result can be useful information in assessing the feasibility of MBF quantification in clinical routine.

2.
Ann Nucl Cardiol ; 8(1): 14-20, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36540183

RESUMEN

Purpose: Heart-type fatty acid binding protein (H-FABP) is primary transporter of free fatty acid and plays an important role in myocardial metabolism, which is characterized by high specificity and rapid appearance under ischemic condition. The objective of this study was to clarify the usefulness of imaging study of targeting H-FABP appearance using radio-labeled antibody, and correlation with myocardial fatty acid metabolism and perfusion in acute reperfusion ischemia. Method: Wistar rats were allotted to sham-operated control group (sham; n=4), ischemia non-reperfused group (IG; n=5), and ischemia-reperfusion group (RG; n=5). Ligation of left coronary artery (LCA) was performed for IG and RG. 20 min of ischemia was followed by 60min of reperfusion for RG. 125I labeled anti H-FABP antibody (anti H-FABP), BMIPP and 99mTc-sestamibi (MIBI) was injected intravenously. Multi-tracer digital autoradiogram was performed using µ-imager®. The ratio of radioactivity in LCA related (culprit) area to the inferior (remote) area (target uptake ratio=TUR) was generated. Results: In sham group, no visually detectable accumulation was observed for the anti H-FABP image, and TURMIBI and TURBMIPP were equivalent to 1. In IG, TURMIBI and TURBMIPP were remarkably low (0.12±0.01, 0.24±0.07). In RG, TURMIBI was significantly lower (0.20±0.03, p<0.05 vs. other groups). However, TURBMIPP was significantly higher (2.78±1.28, p<0.05) compared to the sham and IG, whereas anti H-FABP showed markedly higher ratio in the reperfused area compared to the sham and IG (3.43±0.73 vs. 0.31±0.13 and 1.09±0.07 for IG and sham; p<0.05, and <0.01, respectively). Conclusion: Anti H-FABP accumulated specifically in reperfused area under acute ischemia, and it accorded to the area where fatty acid metabolism was activated. This study has shown the future potential for clinical application in vivo imaging of acute coronary syndrome.

3.
Ann Nucl Med ; 34(2): 144-151, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31834567

RESUMEN

OBJECTIVE: The efficacy of low-dose radioiodine therapy (RIT) for intermediate-risk or high-risk differentiated thyroid cancer (DTC) patients is controversial. Because of the country's shortage of medical facilities for RIT, 1110-MBq RIT for higher risk DTC patients has been performed on an outpatient basis since 2010 in Japan. Herein, we addressed this issue and attempted to determine prognostic factors for the prediction of RIT outcomes. METHODS: We retrospectively analyzed the cases of 119 patients with papillary thyroid cancer who underwent their first RIT with 1110 MBq radioactive iodine (RAI) following a total thyroidectomy, including 65 (54.6%) intermediate-risk and 54 (45.4%) high-risk patients (according to Japan's 2018 clinical practical guidelines for thyroid tumors). Successful ablation was defined when a negative I-131 whole-body scan and thyroglobulin (Tg) < 2 ng/mL were obtained at a diagnostic scan performed 148-560 days (median 261 days) after the first RIT. RESULTS: The overall ablation success rate was 23.4%. Although the ablation success rates of each pretreatment protocol [recombinant human thyroid stimulating hormone and thyroid hormone withdrawal (THW)] did not differ significantly, THW tended to result in a higher success rate than rhTSH. The Tg level at RIT was the only independent powerful predictive factor for successful ablation. The best cut-off value of Tg for predicting unsuccessful ablation was 9 ng/mL. CONCLUSIONS: The ablation success rate was much lower than those of earlier studies; the most plausible reason would be that higher risk DTC patients were included in this study. The low-dose RIT routinely performed in Japan might be inadequate for the achievement of successful ablation. At least for patients with Tg > 9 ng/mL at the first RIT, a higher dose of RAI is recommended.


Asunto(s)
Antineoplásicos/farmacología , Radioisótopos de Yodo/farmacología , Cáncer Papilar Tiroideo/radioterapia , Neoplasias de la Tiroides/radioterapia , Adulto , Anciano , Relación Dosis-Respuesta en la Radiación , Femenino , Estudios de Seguimiento , Humanos , Japón , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo , Tiroglobulina/metabolismo , Tiroidectomía , Tirotropina Alfa/metabolismo , Factores de Tiempo , Resultado del Tratamiento , Imagen de Cuerpo Entero
4.
Ann Nucl Med ; 26(4): 370-8, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22450825

RESUMEN

OBJECTIVES: This study was undertaken to measure the radiation exposure level of caregivers following outpatient NaI (I-131) 1,110 MBq therapy for remnant thyroid ablation after total thyroidectomy in patients with differentiated thyroid cancer, and to evaluate the influence of activities of daily living on radiation exposure level, with the goal of proposing an optimum method of I-131 therapy. METHODS: The study included 37 patients with differentiated thyroid cancer, who had undergone total thyroidectomy and received outpatient based remnant thyroid ablation using NaI (I-131) 1,110 MBq, who were satisfying the following requirements: (1) patients who have no evidence of distant metastases, (2) whose living environments were appropriate for outpatient I-131 (1,110 MBq) therapy, and (3) patients who gave written informed consent. The dose rate at a distance of 1 m from the body surface of the patient at the moment of release was measured using survey meters of the GM type or ionization chamber type. The dose level for the caregiver was measured with a personal dosimeter in all cases. RESULTS: The dose rate at a distance of 1 m from the patient's body surface 1 h after I-131 administration was in the range of 29-115 µSv/h (mean 63.8 µSv/h). The 7-day cumulative effective dose of caregivers was 0.11 ± 0.08 mSv, on an average, in 34 dosimeters. In 31 of 34 dosimeters, cumulative effective dose of caregivers was below 0.2 mSv. Dose levels exceeding 0.2 mSv were recorded in 3 cases (0.21, 0.35 and 0.43 mSv in one case each). These results suggest that the exposure level of family members (caregiver and others) was minimal and is lower than the radiation levels affecting human environments. CONCLUSION: Outpatient-based remnant thyroid ablation with I-131 (1,110 MBq) performed after total thyroidectomy in patients with differentiated thyroid cancer is safe if applied in accordance with the appropriate supervision and guidance by experts with certain qualifications.


Asunto(s)
Técnicas de Ablación/métodos , Atención Ambulatoria/métodos , Exposición a Riesgos Ambientales/análisis , Control Social Formal , Neoplasias de la Tiroides/cirugía , Tiroidectomía , Actividades Cotidianas , Adulto , Anciano , Cuidadores , Familia , Femenino , Humanos , Radioisótopos de Yodo/efectos adversos , Radioisótopos de Yodo/uso terapéutico , Masculino , Persona de Mediana Edad , Neoplasia Residual , Dosis de Radiación , Neoplasias de la Tiroides/patología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...