Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Mikrochim Acta ; 191(3): 156, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38407632

RESUMEN

A magnetic fluorescent molecularly imprinted sensor was successfully prepared and implemented to determine catechol (CT). Fe3O4 nanoparticles were synthesized by the solvothermal technique and mesoporous Fe3O4@SiO2@mSiO2 imprinted carriers were prepared by coating nonporous and mesoporous SiO2 shells on the surface of the Fe3O4 subsequently. The magnetic surface molecularly imprinted fluorescent sensor was created after the magnetic mesoporous carriers were modified with γ-methacryloxyl propyl trimethoxy silane to introduce double bonds on the surface of the carries and the polymerization was carried out in the presence of CT and fluorescent monomers. The magnetic mesoporous carriers were modified with γ-methacryloxyl propyl trimethoxy silane and double bonds were introduced on the surface of the carriers. After CT binding with the molecularly imprinted polymers (MIPs), the fluorescent intensity of the molecularly imprinted polymers (Ex = 400 nm, Em = 523 nm) increased significantly. The fluorescent intensity ratio (F/F0) of the sensor demonstrated a favorable linear correlation with the concentration of CT between 5 and 50 µM with a detection limit of 0.025 µM. Furthermore, the sensor was successfully applied to determine CT in actual samples with recoveries of 96.4-105% and relative standard deviations were lower than 3.5%. The results indicated that the research of our present work provided an efficient approach for swiftly and accurately determining organic pollutant in water.

2.
Mikrochim Acta ; 190(4): 161, 2023 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-36976361

RESUMEN

A sensitive molecularly imprinted ratiometric fluorescence sensor was constructed for the first time to visually detect tetrabromobisphenol A (TBBPA). The blue fluorescent carbon quantum dots (CQDs) were coated with SiO2 through the reverse microemulsion method to obtain a stable internal reference signal CQDs@SiO2. The ratiometric fluorescence sensor was finally prepared using red fluorescent CdTe QDs as the response signal in the presence of CQDs@SiO2. When the molecularly imprinted polymers were combined with TBBPA, the fluorescence of CdTe QDs (Ex = 365 nm, Em = 665 nm) was rapidly quenched, while that of CQDs (Ex = 365 nm, Em = 441 nm) remained stable, resulting in a noticeable fluorescence color change. Moreover, the fluorescence intensity ratio (I665/I441)0/(I665/I441) of the sensor showed a linear response to TBBPA in the concentration range 0.1 to 10 µM with a low detection limit of 3.8 nM. The prepared sensor was successfully applied to detect TBBPA in water samples. The recoveries were in the range 98.2-103%, with relative standard deviations lower than 2.5%. Furthermore, a fluorescent test strip for visual monitoring of TBBPA was constructed to streamline the procedure. The excellent results demonstrate that the prepared test strip has a broad prospect for the offline detection of pollutants.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...