Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
2.
Behav Pharmacol ; 35(4): 147-155, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38651979

RESUMEN

Previous exposure to drugs of abuse produces impairments in studies of reversal learning, delay discounting and response inhibition tasks. While these studies contribute to the understanding of normal decision-making and how it is impaired by drugs of abuse, they do not fully capture how decision-making impacts the ability to delay gratification for greater long-term benefit. To address this issue, we used a diminishing returns task to study decision-making in rats that had previously self-administered cocaine. This task was designed to test the ability of the rat to choose to delay gratification in the short-term to obtain more reward over the course of the entire behavioral session. Rats were presented with two choices. One choice had a fixed amount of time delay needed to obtain reward [i.e. fixed delay (FD)], while the other choice had a progressive delay (PD) that started at 0 s and progressively increased by 1 s each time the PD option was selected. During the 'reset' variation of the task, rats could choose the FD option to reset the time delay associated with the PD option. Consistent with previous results, we found that prior cocaine exposure reduced rats' overall preference for the PD option in post-task reversal testing during 'no-reset' sessions, suggesting that cocaine exposure made rats more sensitive to the increasing delay of the PD option. Surprisingly, however, we found that rats that had self-administered cocaine 1-month prior, adapted behavior during 'reset' sessions by delaying gratification to obtain more reward in the long run similar to control rats.


Asunto(s)
Cocaína , Descuento por Demora , Recompensa , Autoadministración , Animales , Cocaína/farmacología , Cocaína/administración & dosificación , Masculino , Descuento por Demora/efectos de los fármacos , Ratas , Conducta de Elección/efectos de los fármacos , Condicionamiento Operante/efectos de los fármacos , Inhibidores de Captación de Dopamina/farmacología , Inhibidores de Captación de Dopamina/administración & dosificación , Toma de Decisiones/efectos de los fármacos , Trastornos Relacionados con Cocaína/psicología , Ratas Long-Evans , Factores de Tiempo
3.
Zhonghua Gan Zang Bing Za Zhi ; 32(1): 35-39, 2024 Jan 20.
Artículo en Chino | MEDLINE | ID: mdl-38320789

RESUMEN

Objective: The transjugular or transfemoral approach is used as a common method for hepatic venous pressure gradient (HVPG) measurement in current practice. This study aims to confirm the safety and effectiveness of measuring HVPG via the forearm venous approach. Methods: Prospective recruitment was conducted for patients with cirrhosis who underwent HVPG measurement via the forearm venous approach at six hospitals in China and Japan from September 2020 to December 2020. Patients' clinical baseline information and HVPG measurement data were collected. The right median cubital vein or basilic vein approach for all enrolled patients was selected. The HVPG standard process was used to measure pressure. Research data were analyzed using SPSS 22.0 statistical software. Quantitative data were used to represent medians (interquartile ranges), while qualitative data were used to represent frequency and rates. The correlation between two sets of data was analyzed using Pearson correlation analysis. Results: A total of 43 cases were enrolled in this study. Of these, 41 (95.3%) successfully underwent HVPG measurement via the forearm venous approach. None of the patients had any serious complications. The median operation time for HVPG detection via forearm vein was 18.0 minutes (12.3~38.8 minutes). This study confirmed that HVPG was positively closely related to Child-Pugh score (r = 0.47, P = 0.002), albumin-bilirubin score (r = 0.37, P = 0.001), Lok index (r = 0.36, P = 0.02), liver stiffness (r = 0.58, P = 0.01), and spleen stiffness (r = 0.77, P = 0.01), while negatively correlated with albumin (r = -0.42, P = 0.006). Conclusion: The results of this multi-centre retrospective study suggest that HVPG measurement via the forearm venous approach is safe and feasible.


Asunto(s)
Hipertensión Portal , Humanos , Hipertensión Portal/complicaciones , Estudios Retrospectivos , Estudios Prospectivos , Antebrazo , Cirrosis Hepática/complicaciones , Presión Portal , Albúminas , Presión Venosa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...