Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Acta Otolaryngol ; 139(11): 1008-1013, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31512546

RESUMEN

Background: Serum thyroid hormone levels are closely related to the normal functioning of the cochlea. However, the relationship between initial auditory brainstem response (ABR) results and levels of thyroid hormone remained unclear until we adopted ABR as a prognostic factor in Idiopathic sudden sensorineural hearing loss (ISSNHL) patients. Objective: This investigation aimed to elucidate the association between ABR and outcomes in patients with ISSNHL. Material and methods: Thirty-three patients presenting with unilateral ISSNHL underwent blood sampling and ABR tests on the day of admission. The mean latencies of the ABR results were compared among the groups which were classified by ISSNHL outcome, based on Siegel's criteria. The association between the ABR results and the thyroid hormone serum levels (TSH, T3, and free T4) were assessed. Results: The overall successful recovery rate was 60.6% (n = 20). The mean latencies of all the ABR parameters were not significantly different between the different treatment outcome groups (Mann-Whitney U test). Wave V latency, III-V interval and I-V interval were negatively associated with T3 serum levels. Conclusion: The results indicate that clinical caution should be exercised when conducting ABR tests without assessing thyroid hormone levels.


Asunto(s)
Potenciales Evocados Auditivos del Tronco Encefálico , Pérdida Auditiva Sensorineural/diagnóstico , Pérdida Auditiva Súbita/diagnóstico , Adulto , Anciano , Femenino , Pérdida Auditiva Sensorineural/sangre , Pérdida Auditiva Súbita/sangre , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Hormonas Tiroideas/sangre , Adulto Joven
2.
J Audiol Otol ; 23(3): 145-152, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31315391

RESUMEN

BACKGROUND AND OBJECTIVES: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. SUBJECTS AND METHODS: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. RESULTS: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. CONCLUSIONS: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...