1.
Cardiovasc Revasc Med ; 19(8S): 56-57, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29779974

RESUMEN

Severe radial artery spasm is a complication of transradial cardiac catheterization. We describe a case of severe radial artery spasm causing catheter entrapment. The spasm was refractory and resistant to intra-arterial vasodilators, systemic vasodilators, and moderate sedation. Rotaglide™ (Boston Scientific, Marlborough, MA) solution via continuous infusion was delivered through the catheter and then the sheath, resolving the spasm and allowing the removal of the catheter and sheath without injury to the radial artery.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Arteria Radial , Espasmo/tratamiento farmacológico , Vasodilatación/efectos de los fármacos , Vasodilatadores/administración & dosificación , Angiografía , Humanos , Infusiones Intravenosas , Masculino , Persona de Mediana Edad , Espasmo/diagnóstico , Espasmo/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...