Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Analyst ; 136(14): 2981-7, 2011 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-21666910

RESUMEN

In this paper, we examine how variations in normal tissue can influence disease classification of Raman spectra. Raman spectra from normal areas may be affected by previous disease or proximity to areas of dysplasia. Spectra were acquired in vivo from 172 patients and classified into five tissue categories: true normal (no history of disease), previous disease normal (history of disease, current normal diagnosis), adjacent normal (disease on cervix, spectra acquired from visually normal area), low grade, and high grade. Taking into account the various "normal" states of the tissue before statistical analysis led to a disease classification accuracy of 97%. These results indicate that abnormal changes significantly affect Raman spectra, even when areas are histopathologically normal. The sensitivity of Raman spectroscopy to subtle biochemical differences must be considered in order to successfully implement it in a clinical setting for diagnosing cervical dysplasia and cancer.


Asunto(s)
Espectrometría Raman/métodos , Displasia del Cuello del Útero/clasificación , Cuello del Útero/patología , Femenino , Humanos , Índice de Severidad de la Enfermedad , Displasia del Cuello del Útero/diagnóstico , Displasia del Cuello del Útero/patología
2.
J Biophotonics ; 2(1-2): 81-90, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19343687

RESUMEN

Cervical cancer is the second most common malignancy among women worldwide, with over 490 000 cases diagnosed and 274 000 deaths each year. Although current screening methods have dramatically reduced cervical cancer incidence and mortality in developed countries, a "See and Treat" method would be preferred, especially in developing countries. Results from our previous work have suggested that Raman spectroscopy can be used to detect cervical precancers; however, with a classification accuracy of 88%, it was not clinically applicable. In this paper, we describe how incorporating a woman's hormonal status, particularly the point in menstrual cycle and menopausal state, into our previously developed classification algorithm improves the accuracy of our method to 94%. The results of this paper bring Raman spectroscopy one step closer to being utilized in a clinical setting to diagnose cervical dysplasia.


Asunto(s)
Espectrometría Raman/métodos , Displasia del Cuello del Útero/diagnóstico , Adolescente , Adulto , Anciano , Algoritmos , Femenino , Humanos , Menopausia , Ciclo Menstrual , Persona de Mediana Edad , Análisis Multivariante , Frotis Vaginal , Adulto Joven
3.
Am J Obstet Gynecol ; 200(5): 512.e1-5, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19236872

RESUMEN

OBJECTIVE: The objective of the study was to characterize the variations in normal cervical spectra because of menopausal status and location within the menstrual cycle. Using the information obtained, the accuracy of Raman spectroscopy to diagnose low-grade squamous intraepithelial lesion (LGSIL) will be improved. STUDY DESIGN: A total of 133 patients undergoing either colposcopy or Papanicolaou smear were recruited from either Vanderbilt University or Tri-State Women's Health. Raman spectra were collected from both normal and diseased areas. The data were processed and analyzed using a multiclass discrimination and classification algorithm to determine whether the spectra were correctly classified. RESULTS: Stratifying the data by menopausal state resulted in correctly classifying LGSIL 97% of the time (from 74%). CONCLUSION: This study brings Raman spectroscopy one step closer to clinical use by improving the sensitivity to differentiate LGSIL from normal.


Asunto(s)
Hormonas/metabolismo , Menopausia , Ciclo Menstrual , Espectrometría Raman/normas , Displasia del Cuello del Útero/diagnóstico , Adulto , Algoritmos , Colposcopía , Diagnóstico Diferencial , Femenino , Humanos , Persona de Mediana Edad , Ovulación , Prueba de Papanicolaou , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría Raman/instrumentación , Displasia del Cuello del Útero/metabolismo , Frotis Vaginal
4.
J Raman Spectrosc ; 40(2): 205-211, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21691450

RESUMEN

Raman spectroscopy has the potential to differentiate among the various stages leading to high-grade cervical cancer such as normal, squamous metaplasia, and low-grade cancer. For Raman spectroscopy to successfully differentiate among the stages, an applicable statistical method must be developed. Algorithms like linear discriminant analysis (LDA) are incapable of differentiating among three or more types of tissues. We developed a novel statistical method combining the method of maximum representation and discrimination feature (MRDF) to extract diagnostic information with sparse multinomial logistic regression (SMLR) to classify spectra based on nonlinear features for multiclass analysis of Raman spectra. We found that high-grade spectra classified correctly 95% of the time; low-grade data classified correctly 74% of the time, improving sensitivity from 92 to 98% and specificity from 81 to 96% suggesting that MRDF with SMLR is a more appropriate technique for categorizing Raman spectra. SMLR also outputs a posterior probability to evaluate the algorithm's accuracy. This combined method holds promise to diagnose subtle changes leading to cervical cancer.

5.
Appl Spectrosc ; 62(5): 575-82, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18498700

RESUMEN

A common goal of most Raman spectroscopists is the acquisition of clear Raman spectra in short integration times. It is paramount, then, that the hardware used in a Raman system be optimized for throughput, signal-to-noise ratio, and resolution. To this end, we performed a systematic comparison of two Raman spectrographs: the widely used Kaiser HoloSpec and a relatively new commercial offering, the Raman Explorer by Headwall Photonics. Both strong and weak Raman scattering samples were measured using various launching conditions. When resolution-matched, the throughputs of both spectrographs were found to be roughly similar over the central range of the fingerprint region (approximately 800 to 1140 cm(-1), using 785 nm illumination), with the Raman Explorer demonstrating a slight throughput advantage outside this range. Other factors are also considered such that end users may better select the optimum spectrograph for their particular application.


Asunto(s)
Espectrometría Raman/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Tecnología de Fibra Óptica , Espectrofotometría Infrarroja , Espectrofotometría Ultravioleta , Espectrometría Raman/instrumentación
6.
Dis Markers ; 25(6): 323-37, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-19208950

RESUMEN

Epithelial cancers, including those of the skin and cervix, are the most common type of cancers in humans. Many recent studies have attempted to use Raman spectroscopy to diagnose these cancers. In this paper, Raman spectral markers related to the temporal and spatial effects of cervical and skin cancers are examined through four separate but related studies. Results from a clinical cervix study show that previous disease has a significant effect on the Raman signatures of the cervix, which allow for near 100% classification for discriminating previous disease versus a true normal. A Raman microspectroscopy study showed that Raman can detect changes due to adjacent regions of dysplasia or HPV that cannot be detected histologically, while a clinical skin study showed that Raman spectra may be detecting malignancy associated changes in tissues surrounding nonmelanoma skin cancers. Finally, results of an organotypic raft culture study provided support for both the skin and the in vitro cervix results. These studies add to the growing body of evidence that optical spectroscopy, in this case Raman spectral markers, can be used to detect subtle temporal and spatial effects in tissue near cancerous sites that go otherwise undetected by conventional histology.


Asunto(s)
Biomarcadores de Tumor/análisis , Transformación Celular Neoplásica/patología , Neoplasias Glandulares y Epiteliales/diagnóstico , Neoplasias Glandulares y Epiteliales/patología , Neoplasias Cutáneas/diagnóstico , Neoplasias Cutáneas/patología , Espectrometría Raman/métodos , Neoplasias del Cuello Uterino/diagnóstico , Neoplasias del Cuello Uterino/patología , Adolescente , Adulto , Anciano , Técnicas de Cultivo de Célula , Cuello del Útero/patología , Progresión de la Enfermedad , Femenino , Humanos , Persona de Mediana Edad , Neoplasias Glandulares y Epiteliales/química , Sensibilidad y Especificidad , Piel/patología , Neoplasias Cutáneas/química , Neoplasias del Cuello Uterino/química
7.
J Biomed Opt ; 11(4): 041123, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16965151

RESUMEN

Ovarian cancer is the fifth leading cause of cancer death in women, in part because of the limited knowledge about early stage disease. We develop a novel rat model of ovarian cancer and perform a pilot study to examine the harvested ovaries with complementary optical imaging modalities. Rats are exposed to repeated daily dosing (20 days) with 4-vinylcyclohexene diepoxide (VCD) to cause early ovarian failure (model for postmenopause), and ovaries are directly exposed to 7,12-dimethylbenz(a)anthracene (DMBA) to cause abnormal ovarian proliferation and neoplasia. Harvested ovaries are examined with optical coherence tomography (OCT) and light-induced fluorescence (LIF) at one, three, and five months post-DMBA treatment. VCD causes complete ovarian follicle depletion within 8 months after onset of dosing. DMBA induces abnormal size, cysts, and neoplastic changes. OCT successfully visualizes normal and abnormal structures (e.g., cysts, bursa, follicular remnant degeneration) and the LIF spectra show statistically significant changes in the ratio of average emission intensity at 390:450 nm between VCD-treated ovaries and both normal cycling and neoplastic DMBA-treated ovaries. Overall, this pilot study demonstrates the feasibility of both the novel animal model for ovarian cancer and the ability of optical imaging techniques to visualize ovarian function and health.


Asunto(s)
Modelos Animales de Enfermedad , Microscopía Fluorescente/métodos , Neoplasias Ováricas/patología , Ovario/patología , Lesiones Precancerosas/patología , Tomografía de Coherencia Óptica/métodos , 9,10-Dimetil-1,2-benzantraceno , Animales , Carcinógenos , Ciclohexenos , Femenino , Neoplasias Ováricas/inducido químicamente , Proyectos Piloto , Lesiones Precancerosas/inducido químicamente , Ratas , Ratas Endogámicas F344 , Ratas Sprague-Dawley , Compuestos de Vinilo
8.
Phys Med Biol ; 51(6): 1563-75, 2006 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-16510963

RESUMEN

Optical coherence tomography (OCT) is an imaging modality capable of acquiring cross-sectional images of tissue using back-reflected light. Conventional OCT images have a resolution of 10-15 microm, and are thus best suited for visualizing tissue layers and structures. OCT images of collagen (with and without endothelial cells) have no resolvable features and may appear to simply show an exponential decrease in intensity with depth. However, examination of these images reveals that they display a characteristic repetitive structure due to speckle. The purpose of this study is to evaluate the application of statistical and spectral texture analysis techniques for differentiating living and non-living tissue phantoms containing various sizes and distributions of scatterers based on speckle content in OCT images. Statistically significant differences between texture parameters and excellent classification rates were obtained when comparing various endothelial cell concentrations ranging from 0 cells/ml to 25 million cells/ml. Statistically significant results and excellent classification rates were also obtained using various sizes of microspheres with concentrations ranging from 0 microspheres/ml to 500 million microspheres/ml. This study has shown that texture analysis of OCT images may be capable of differentiating tissue phantoms containing various sizes and distributions of scatterers.


Asunto(s)
Tomografía de Coherencia Óptica/métodos , Algoritmos , Animales , Aorta/metabolismo , Artefactos , Bovinos , Células Cultivadas , Colágeno/química , Células Endoteliales/metabolismo , Gelatina/química , Interpretación de Imagen Asistida por Computador , Luz , Microesferas , Modelos Estadísticos , Fantasmas de Imagen , Dispersión de Radiación , Propiedades de Superficie , Tomografía , Tomografía Óptica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...