Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 977
Filtrar
1.
J Am Heart Assoc ; 13(15): e034298, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39101495

RESUMEN

BACKGROUND: Studies have shown inconclusive results on the effectiveness of cerebral protection devices (CPDs) with transcatheter aortic valve replacement. We aimed to analyze the national statistics on stroke and other outcomes with CPD use. METHODS AND RESULTS: The Nationwide Readmissions Database (2017-2020) was queried to obtain data on patients undergoing transcatheter aortic valve replacement. Outcomes were compared between patients with a CPD and patients without a CPD. Of 271 804 patients undergoing transcatheter aortic valve replacement, CPD was used in 7.3% of patients. In a multivariable logistic regression analysis, CPD use was not associated with lower overall stroke rates (1.6% versus 1.9% without CPD; odds ratio, 0.95 [95% CI, 0.84-1.07]; P=0.364), but it was significantly associated with lower major stroke rates (1.2% versus 1.5% without CPD; odds ratio, 0.85 [95% CI, 0.74-0.98]; P=0.02). Patients with a CPD also had a shorter length of stay, higher routine discharges to home/self-care (74.9% versus 70.6%), and lower mortality rates (0.7% versus 1.3%). The 30-day (9.6% versus 11.7%) and 180-day (24.6% versus 28.2%) readmission rates were significantly lower in the CPD cohort. Among patients who developed stroke, patients with a CPD had more frequent routine discharges. Prior valve surgery was associated with the highest risk of overall and major stroke. CONCLUSIONS: CPD use during transcatheter aortic valve replacement was not independently associated with a lower risk of overall stroke but was associated with a lower risk of major stroke in a multivariable model. Data from future randomized trials that may offset any potential confounders in our study are required to help identify patients who would benefit from the use of these devices.


Asunto(s)
Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Masculino , Femenino , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Anciano de 80 o más Años , Anciano , Factores de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estados Unidos/epidemiología , Dispositivos de Protección Embólica , Medición de Riesgo/métodos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Resultado del Tratamiento , Readmisión del Paciente/estadística & datos numéricos , Estudios Retrospectivos , Bases de Datos Factuales , Incidencia , Factores de Tiempo
2.
J Soc Cardiovasc Angiogr Interv ; 3(7): 102019, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39132010

RESUMEN

Iatrogenic mitral stenosis is a rare complication of the MitraClip procedure for which limited therapeutic options exist. We present a unique case using real-time echocardiographic and hemodynamic data demonstrating a potential role for interatrial septostomy creation as a percutaneous management option in this challenging population.

3.
J Soc Cardiovasc Angiogr Interv ; 3(5): 101345, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-39132458

RESUMEN

Background: Transcatheter edge-to-edge repair (TEER) improved outcomes in patients with heart failure (HF) and severe secondary mitral regurgitation (SMR) compared with guideline-directed medical therapy (GDMT) alone regardless of the severity of baseline left ventricular ejection fraction (LVEF). The study aimed to evaluate the effect of early changes in LVEF after TEER and GDMT alone in patients with HF and severe SMR. Methods: Within the COAPT trial, we evaluated outcomes according to changes in LVEF from baseline to 30 days. The primary outcome was all-cause death or HF hospitalization (HFH) between 30 days and 2 years. Results: Among 432 patients with paired echocardiographic data, 182 (42.1%) had increased LVEF (LVEF change 6.0% ± 4.9%) and 250 (57.9%) had a decrease or no change in LVEF (LVEF change -6.6% ± 5.6%) from baseline to 30 days. LVEF at 30 days increased more frequently with GDMT alone compared with TEER plus GDMT (51.4% vs 33.0%; P = .0001). Between 30 days and 2 years, there were no significant differences in death or HFH in the increase LVEF and the decrease LVEF groups (58.8% vs 51.4%; multivariable-adjusted HR, 0.97; 95% CI, 0.87-1.08; P = .59). TEER plus GDMT reduced the 30-day to 2-year rate of death or HFH compared with GDMT alone consistently in patients with increase LVEF and decrease LVEF (Pint = 0.75). Conclusions: Among patients with HF and severe SMR, early improvements in LVEF were more frequent with GDMT alone compared with TEER plus GDMT but were not associated with subsequent outcomes at 2 years. TEER reduced death or HFH during 2-year follow-up irrespective of early LVEF changes.

4.
Circulation ; 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39101203

RESUMEN

BACKGROUND: Previous transcatheter valve therapy registry analyses of transcatheter mitral valve in valve (MViV) replacement of degenerated bioprosthesis reported early experience in the United States. Given recent increases in transseptal MViV volumes and introduction of the SAPIEN 3 Ultra valve, it is important to determine contemporary outcomes for patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV replacement. METHODS: The Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy Registry was used to extract data for all patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV from 2015 to September 2022. Primary efficacy outcome was 1-year all-cause mortality. Secondary end points included 30-day mortality, functional class, quality of life, and mitral valve performance. Primary safety outcomes were device success and in-hospital complications. RESULTS: A total of 4243 patients with a mean STS score of 9.2±7.7 underwent transseptal MViV at 455 sites. The rate of Mitral Valve Academic Research Consortium technical (96.6%) success was high, and procedural complications were low. All-cause in-hospital, 30-day, and 1-year mortality rates were 3.2%, 4.3%, and 13.4%, respectively. Significant improvements in New York Heart Association class (New York Heart Association I/II, 18% to 87%) and quality of life (Kansas City Cardiomyopathy Questionnaire score, 38 to 78) were noted at 1 year (P<0.0001 for both) after MViV. Upon stratifying by STS scores, it was observed that the low-risk group (STS<4) had a significantly lower in-hospital mortality rate of 0.4%, whereas the intermediate-risk group (STS, 4-8) had an in-hospital mortality rate of 1.9%. From 2015 to 2022, the number of transseptal MViV cases/year increased significantly, whereas procedure times, length of stay, and intensive care unit hours shortened significantly. At the same time, there was a significant trend toward reduced in-hospital (P=0.0005), 30-day (P=0.004), and 1-year mortality rates (P=0.01). CONCLUSIONS: This multicenter, prospective study reports excellent procedural outcomes, 1-year mortality rates, and a significant improvement in quality of life for patients undergoing transseptal MViV in the contemporary era. Patients in the low-risk and intermediate-risk STS score categories had significantly better outcomes compared with those in the high-risk category. MViV is a reasonable therapy for the majority of patients with degenerated bioprosthetic mitral valves, who are anatomical candidates.

6.
Circ Cardiovasc Interv ; : e013750, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39056187

RESUMEN

BACKGROUND: PINNACLE FLX (Protection Against Embolism for Nonvalvular AF Patients: Investigational Device Evaluation of the WATCHMAN FLX LAA Closure Technology) demonstrated improved outcomes and low incidence of adverse events with the WATCHMAN FLX device in a controlled setting. The National Cardiovascular Disease Registry's Left Atrial Appendage Occlusion Registry was utilized to assess the safety and effectiveness of WATCHMAN FLX in contemporary clinical practice in the United States. METHODS: The WATCHMAN FLX Device Surveillance Post Approval Analysis Plan used data from the Left Atrial Appendage Occlusion registry to identify patients undergoing WATCHMAN FLX implantation between August 2020 and September 2022. The key safety end point was defined as all-cause death, ischemic stroke, systemic embolism, or device or procedure-related events requiring open cardiac surgery or major endovascular intervention between device implantation and hospital discharge. Major adverse events were reported at hospital discharge, 45 days, and 1 year. RESULTS: Among 97 185 patients in the Left Atrial Appendage Occlusion registry undergoing WATCHMAN FLX, successful implantation occurred in 97.5% (n=94 784) of patients. The key safety end point occurred in 0.45% of patients. At 45 days post-procedure, all-cause death occurred in 0.81% patients, ischemic stroke in 0.23%, major bleeding in 3.1%, pericardial effusion requiring intervention in 0.50%, device-related thrombus in 0.44%, and device embolism in 0.04% patients. No peri-device leak was observed in 83.1% of patients at 45 days. At 1 year, the rate of all-cause death was 8.2%, the rate of any stroke was 1.5% (ischemic stroke, 1.2%), and major bleeding occurred in 6.4% of patients. CONCLUSIONS: In a large contemporary cohort of patients with the WATCHMAN FLX device, the rates of implant success and clinical outcomes through 1 year were comparable with the PINNACLE FLX study, demonstrating that favorable outcomes achieved in the pivotal approval study can be replicated in routine clinical practice.

7.
Am J Cardiol ; 227: 29-36, 2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-38950689

RESUMEN

Heart failure (HF) and moderate-to-severe mitral regurgitation (MR) with residual elevations in left atrial pressure (LAP) after MitraClip may remain symptomatic and experience subsequent HF readmissions. The V-Wave interatrial shunt system is a permanent interatrial septal implant that shunts blood from the left-to-right atrium and serves to continuously unload the left atrium. Although the V-Wave shunt has previously been studied in patients with HF, the safety and feasibility of its deployment at the time of the MitraClip procedure is unknown. The V-Wave Shunt MitraClip Study (NCT04729933) is an early feasibility study that aims to demonstrate the safety and efficacy of implantation of the V-Wave shunt device at the time of MitraClip procedure. Patients with moderate-to-severe secondary MR with left ventricular ejection fraction 20% to 50% and New York Heart Association functional class III/IV symptoms despite optimal medical therapy, residual mean LAP ≥20 mm Hg after MitraClip, and mean LAP-right atrial pressure difference ≥5 mm Hg are included. The primary safety end point is a composite outcome of all-cause death, stroke, myocardial infarction device embolization, cardiac tamponade, or device-related re-intervention or surgery at 30 days. Patients will be followed up to 5 years. Enrollment is ongoing, with 30-day results expected by the end of 2024. The V-Wave Shunt Mitraclip Study aims to demonstrate the safety and efficacy of the implantation of the V-Wave interatrial shunt device at the time of index MitraClip placement which may serve as an adjunctive method by which continuous left atrial unloading may be achieved.

8.
Am Heart J ; 276: 49-59, 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39032584

RESUMEN

BACKGROUND: Skeletal muscle mass (SMM) plays a crucial role in risk assessment in transcatheter aortic valve replacement (TAVR) candidates, yet it remains underutilized. Traditional methods focus on weakness or performance but omit SMM. This study compared traditional and novel markers of sarcopenia and frailty in terms of their ability to predict adverse outcomes post-TAVR. METHODS: Three risk models were evaluated for the composite outcome of perioperative complications, 1-year rehospitalization, or 1-year mortality: (1) sarcopenia by combining low muscle mass (LMM) and weakness/performance assessed by hand grip strength or gait speed; (2) frailty by an Adapted Green score; and (3) frailty by the Green-SMI score incorporating LMM by multilevel opportunistic pre-TAVR thoracic CT segmentation. RESULTS: In this study we included 184 eligible patients from January to December of 2018, (96.7%) of which were balloon expandable valves. The three risk models identified 22.8% patients as sarcopenic, 63.6% as frail by the Adapted Green score, and 53.8% as frail by the Green-SMI score. There were higher rates of the composite outcome in patients with sarcopenia (54.8%) and frailty (41.9% with the Adapted Green and 50.5% with the Green-SMI score) compared to their nonsarcopenic (30.3%) and nonfrail counterparts (25.4% with the Adapted Green and 18.8% with the Green-SMI score). Sarcopenia and frailty by Green-SMI, but not by the Adapted Green, were associated with higher risks of the composite outcome on multivariable adjustment (HR 2.2 [95% CI: 1.25-4.02], P = .007 and HR 3.4 [95% CI: 1.75-6.65], P < .001, respectively). CONCLUSIONS: The integration of preoperative CT-based SMM to a frailty score significantly improves the prediction of adverse outcomes in patients undergoing TAVR.

9.
AsiaIntervention ; 10(2): 96-97, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39070973
10.
Artículo en Inglés | MEDLINE | ID: mdl-38904577

RESUMEN

BACKGROUND: Current therapies for pulmonary vein stenosis (PVS) or pulmonary vein total occlusion (PVTO) involving angioplasty and stenting are hindered by high rates of restenosis. OBJECTIVES: This study compares a novel approach of drug-coated balloon (DCB) angioplasty and stenting with the current standard of care in PVS or PVTO due to pulmonary vein isolation (PVI). METHODS: A retrospective single-center study analyzed patients with PVS or PVTO due to PVI who underwent either angioplasty and stenting (NoDCB group; December 2012-December 2016) or DCB angioplasty and stenting (DCB group; January 2018-January 2021). Multivariable Andersen-Gill regression analysis assessed the risk of restenosis and target lesion revascularization (TLR). RESULTS: The NoDCB group comprised 58 patients and 89 veins, with a longer median follow-up of 35 months, whereas the DCB group included 26 patients and 33 veins, with a median follow-up of 11 months. The DCB group exhibited more PVTO (NoDCB: 12.3%; DCB: 42.4%; P = 0.0001), with a smaller reference vessel size (NoDCB: 10.2 mm; DCB: 8.4 mm; P = 0.0004). Follow-up computed tomography was performed in 82% of NoDCB and 85% of DCB, revealing lower unadjusted rates of restenosis (NoDCB: 26%; DCB: 14.3%) and TLR (NoDCB: 34.2%; DCB: 10.7%) in the DCB group. DCB use was associated with a significantly lower risk of restenosis and TLR (HR: 0.003: CI: 0.00009-0.118; P = 0.002). CONCLUSIONS: The novel approach of DCB angioplasty followed by stenting is effective and safe and significantly reduces the risk of restenosis and reintervention compared with the standard of care in PVS or PVTO due to PVI.

11.
Artículo en Inglés | MEDLINE | ID: mdl-38837174

RESUMEN

Background: Cerebral embolic protection devices (EPDs) were developed to mitigate the risk of stroke during transcatheter aortic valve replacement (TAVR), but their benefit remains unproven. In the PROTECTED-TAVR trial, EPD use did not reduce periprocedural stroke (primary study outcome) but led to a 62% reduction in the secondary endpoint of disabling stroke. Given these results, the impact of EPDs during TAVR remains unclear. Methods: We used STS/ACC TVT registry data to examine the association between EPD use and a proxy for disabling stroke among transfemoral TAVR patients between 1/2018-6/2023. The primary outcome was in-hospital disabling stroke-defined as stroke associated with either in-hospital death or discharge to a non-home location. We evaluated the association between EPD use and disabling stroke using instrumental variable (IV) analysis with site-level preference for EPD use as the instrument-a quasi-experimental approach that can support causal inference. In addition, we performed a propensity-score based comparison using overlap weighting as a secondary analysis. Results: The study population consisted of 414,649 patients of whom 53,389 (12.9%) received an EPD. The unadjusted rate of in-hospital disabling stroke was 0.7% among the EPD group and 0.9% in the no EPD group. EPD use was associated with a reduction in disabling stroke in both IV analysis (RR 0.87; 95% CI: 0.73-1.00) and propensity-weighted (PW) analysis (OR 0.79; 95% CI: 0.70-0.90) but was not associated with a reduction in non-disabling stroke. In subgroup analyses, the benefit of EPD was greater among those with versus without prior stroke (interaction p<0.05 for IV and PW). Conclusions: In the largest study to date, among patients undergoing TAVR, EPD use was associated with a small, borderline significant reduction in stroke associated with death or a discharge to a non-home location (a proxy for disabling stroke) that is likely to be causal in nature. Taken together with previous mechanistic and clinical studies, these findings provide credible evidence that EPDs benefit patients undergoing TAVR.

12.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38866455

RESUMEN

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estimulación Cardíaca Artificial , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Factores de Riesgo , Anciano , Factores de Tiempo , Anciano de 80 o más Años , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/mortalidad , Estados Unidos/epidemiología
13.
JACC Adv ; 3(5): 100959, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38939639

RESUMEN

Background: The prognostic value of cardiac damage staging classification based on the extent of extravalvular damage has been proposed in moderate/severe aortic stenosis (AS). Objectives: The purpose of this study was to assess the association of cardiac damage staging with mortality across the spectrum of patients with AS following aortic surgical or transcatheter aortic valve replacement (AVR). Methods: We conducted a pooled meta-analysis of Kaplan-Meier-derived reconstructed time-to-event data from studies published through February 2023. Results: In total, 16 studies (n = 14,499) met our eligibility criteria and included 12,282 patients with symptomatic severe AS and 2,217 patients with asymptomatic severe/moderate AS. For patients with symptomatic severe AS, all-cause mortality was 24.0%, 27.7%, 38.0%, 56.3%, and 57.3% at 5 years in patients with cardiac damage stage 0, 1, 2, 3, and 4, respectively (stage 0 as reference; HR in stage 1: 1.30 [95% CI: 1.03-1.64]; P = 0.029; stage 2: 1.74 [95% CI: 1.41-2.16]; P < 0.001; stage 3: 2.92 [95% CI: 2.35-3.64]; P < 0.001, and stage 4: 3.51 [95% CI: 2.79-4.41]; P < 0.001). For patients with asymptomatic moderate/severe AS, all-cause mortality was 19.3%, 36.9%, 51.7%, and 67.8% at 8 years in patients with cardiac damage stage 0, 1, 2, and 3 to 4, respectively (HR in stage 1: 1.70 [95% CI: 1.21-2.38]; P = 0.002; stage 2: 2.20 [95% CI: 1.60-3.02]; P < 0.001; and stage 3 to 4: 3.90 [95% CI: 2.79-5.47]; P < 0.001). Conclusions: In patients undergoing AVR across the symptomatic and severity spectrum of AS, cardiac damage staging at baseline has important prognostic implications. This pooled meta-analysis in patients undergoing AVR suggests that staging of baseline cardiac damage could be considered for timing and selection of therapy in patients with moderate or severe AS to determine the need for earlier AVR or adjunctive pharmacotherapy to prevent irreversible cardiac damage and improve the long-term prognosis.

15.
Artículo en Inglés | MEDLINE | ID: mdl-38795108

RESUMEN

BACKGROUND: Functional mitral regurgitation induces adverse effects on the left ventricle and the left atrium. Left atrial (LA) dilatation and reduced LA strain are associated with poor outcomes in heart failure (HF). Transcatheter edge-to-edge repair (TEER) of the mitral valve reduces heart failure hospitalization (HFH) and all-cause death in selected HF patients. OBJECTIVES: The aim of this study was to evaluate the impact of LA strain improvement 6 months after TEER on the outcomes of patients enrolled in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial. METHODS: The difference in LA strain between baseline and the 6-month follow-up was calculated. Patients with at least a 15% improvement in LA strain were labeled as "LA strain improvers." All-cause death and HFH were assessed between the 6 and 24-month follow-up. RESULTS: Among 347 patients (mean age 71 ± 12 years, 63% male), 106 (30.5%) showed improvement of LA strain at the 6-month follow-up (64 [60.4%] from the TEER + guideline-directed medical therapy [GDMT] group and 42 [39.6%] from the GDMT alone group). An improvement in LA strain was significantly associated with a reduction in the composite of death or HFH between the 6-month and 24-month follow-up, with a similar risk reduction in both treatment arms (Pinteraction = 0.27). In multivariable analyses, LA strain improvement remained independently associated with a lower risk of the primary composite endpoint both as a continuous variable (adjusted HR: 0.94 [95% CI: 0.89-1.00]; P = 0.03) and as a dichotomous variable (adjusted HR: 0.49 [95% CI: 0.27-0.89]; P = 0.02). The best outcomes were observed in patients treated with TEER in whom LA strain improved. CONCLUSIONS: In symptomatic HF patients with severe mitral regurgitation, improved LA strain at the 6-month follow-up is associated with subsequently lower rates of the composite endpoint of all-cause mortality or HFH, both after TEER and GDMT alone. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [COAPT]; NCT01626079).

16.
Open Heart ; 11(1)2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769066

RESUMEN

OBJECTIVE: Patients with moderate aortic stenosis (AS) exhibit high morbidity and mortality. Limited evidence exists on the role of aortic valve replacement (AVR) in this patient population. To investigate the benefit of AVR in moderate AS on survival and left ventricular function. METHODS: In a retrospective cohort study, patients with moderate AS between 2008 and 2016 were selected from the Cleveland Clinic echocardiography database and followed until 2018. Patients were classified as receiving AVR or managed medically (clinical surveillance). All-cause and cardiovascular mortality were assessed by survival analyses. Temporal haemodynamic and structural changes were assessed with longitudinal analyses using linear mixed effects models. RESULTS: We included 1421 patients (mean age, 75.3±5.4 years and 39.9% women) followed over a median duration of 6 years. Patients in the AVR group had lower risk of all-cause (adjusted HR (aHR)=0.51, 95% CI: 0.34 to 0.77; p=0.001) and cardiovascular mortality (aHR=0.50, 95% CI: 0.31 to 0.80; p=0.004) compared with those in the clinical surveillance group irrespective of sex, receipt of other open-heart surgeries and underlying malignancy. These findings were seen only in those with preserved left ventricular ejection fraction (LVEF) ≥50%. Further, patients in the AVR group had a significant trend towards an increase in LVEF and a decrease in right ventricular systolic pressure compared with those in the clinical surveillance group. CONCLUSIONS: In patients with moderate AS, AVR was associated with favourable clinical outcomes and left ventricular remodelling.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Función Ventricular Izquierda , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico , Femenino , Masculino , Estudios Retrospectivos , Anciano , Implantación de Prótesis de Válvulas Cardíacas/métodos , Función Ventricular Izquierda/fisiología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Factores de Tiempo , Índice de Severidad de la Enfermedad , Estudios de Seguimiento , Factores de Riesgo , Ecocardiografía/métodos , Anciano de 80 o más Años , Tasa de Supervivencia/tendencias , Medición de Riesgo/métodos , Volumen Sistólico/fisiología
18.
Artículo en Inglés | MEDLINE | ID: mdl-38693866

RESUMEN

AIMS: Evaluation of left and right ventricular longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and right ventricular longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30-days and 1-year after aortic valve replacement (AVR). METHODS AND RESULTS: LV longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER-2A surgical AVR (SAVR) arm (n=985) and from the PARTNER-2 SAPIEN-3 registry (n=719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline were associated with increased risk of the composite of death, hospitalization, and stroke at 5-years (Adjusted-HRs for LV LS<15%: 1.24 95%CI 1.05-1.45, p=0.001; TAPSE<14mm: 1.44 95%CI 1.21-1.73, p<0.001; RV/PA coupling<0.55mm/mmHg: 1.32 95% CI 1.07-1.63, p=0.011). Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5-years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95%CI 1.08-1.68, p=0.009) but not with TAVR (HR: 1.12, 95%CI 0.88-1.42). Lower RV-PA coupling at 30-days showed the strongest association with cardiac mortality. CONCLUSION: SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30-days were associated with inferior clinical outcomes at 5-years. In patients with LVEF<50%, TAVR was associated with superior 5-year outcomes.

19.
J Am Heart Assoc ; 13(10): e033601, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38761069

RESUMEN

BACKGROUND: The aims of this study were to understand the incidence and outcomes of patients with cardiogenic shock (CS) due to severe aortic stenosis (AS), and the impact of conventional treatment strategies in this population. METHODS AND RESULTS: All patients admitted to the Cleveland Clinic cardiac intensive care unit between January 1, 2010 and December 31, 2021 with CS were retrospectively identified and categorized into those with CS in the setting of severe AS versus CS without AS. The impact of various treatment strategies on mortality was further assessed. We identified 2754 patients with CS during the study period, of whom 216 patients (8%) had CS in the setting of severe AS. Medical management was associated with the highest 30-day mortality when compared with either balloon aortic valve replacement or aortic valve replacement (surgical or transcatheter aortic valve replacement) (hazard ratio, 3.69 [95% CI, 2.04-6.66]; P<0.0001). Among patients who received transcatheter therapy, 30-day mortality was significantly higher in patients who received balloon aortic valvuloplasty versus transcatheter aortic valve replacement (26% versus 4%, P=0.02). Both surgical and transcatheter aortic valve replacement had considerably lower mortality than medical management and balloon aortic valvuloplasty at 30 days and 1 year (P<0.05 for both comparisons). CONCLUSIONS: CS due to severe AS is associated with high in-hospital and 30-day mortality, worse compared with those with CS without AS. In suitable patients, urgent surgical aortic valvuloplasty or transcatheter aortic valve replacement is associated with favorable short- and long-term outcomes. Although balloon aortic valvuloplasty may be used to temporize patients with CS in the setting of severe AS, mortality is ≈50% if not followed by definitive aortic valve replacement within 90 days.


Asunto(s)
Estenosis de la Válvula Aórtica , Índice de Severidad de la Enfermedad , Choque Cardiogénico , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Choque Cardiogénico/terapia , Choque Cardiogénico/etiología , Choque Cardiogénico/mortalidad , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano de 80 o más Años , Valvuloplastia con Balón/mortalidad , Valvuloplastia con Balón/efectos adversos , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Factores de Riesgo , Factores de Tiempo , Incidencia
20.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38703375

RESUMEN

AIMS: Ablation of monomorphic ventricular tachycardia (MMVT) has been shown to reduce shock frequency and improve survival. We aimed to compare cause-specific risk factors for MMVT and polymorphic ventricular tachycardia (PVT)/ventricular fibrillation (VF) and to develop predictive models. METHODS AND RESULTS: The multicentre retrospective cohort study included 2668 patients (age 63.1 ± 13.0 years; 23% female; 78% white; 43% non-ischaemic cardiomyopathy; left ventricular ejection fraction 28.2 ± 11.1%). Cox models were adjusted for demographic characteristics, heart failure severity and treatment, device programming, and electrocardiogram metrics. Global electrical heterogeneity was measured by spatial QRS-T angle (QRSTa), spatial ventricular gradient elevation (SVGel), azimuth, magnitude (SVGmag), and sum absolute QRST integral (SAIQRST). We compared the out-of-sample performance of the lasso and elastic net for Cox proportional hazards and the Fine-Gray competing risk model. During a median follow-up of 4 years, 359 patients experienced their first sustained MMVT with appropriate implantable cardioverter-defibrillator (ICD) therapy, and 129 patients had their first PVT/VF with appropriate ICD shock. The risk of MMVT was associated with wider QRSTa [hazard ratio (HR) 1.16; 95% confidence interval (CI) 1.01-1.34], larger SVGel (HR 1.17; 95% CI 1.05-1.30), and smaller SVGmag (HR 0.74; 95% CI 0.63-0.86) and SAIQRST (HR 0.84; 95% CI 0.71-0.99). The best-performing 3-year competing risk Fine-Gray model for MMVT [time-dependent area under the receiver operating characteristic curve (ROC(t)AUC) 0.728; 95% CI 0.668-0.788] identified high-risk (> 50%) patients with 75% sensitivity and 65% specificity, and PVT/VF prediction model had ROC(t)AUC 0.915 (95% CI 0.868-0.962), both satisfactory calibration. CONCLUSION: We developed and validated models to predict the competing risks of MMVT or PVT/VF that could inform procedural planning and future randomized controlled trials of prophylactic ventricular tachycardia ablation. CLINICAL TRIAL REGISTRATION: URL:www.clinicaltrials.gov Unique identifier:NCT03210883.


Asunto(s)
Desfibriladores Implantables , Prevención Primaria , Taquicardia Ventricular , Fibrilación Ventricular , Humanos , Femenino , Masculino , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/prevención & control , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Persona de Mediana Edad , Estudios Retrospectivos , Prevención Primaria/métodos , Factores de Riesgo , Medición de Riesgo , Anciano , Fibrilación Ventricular/prevención & control , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/terapia , Resultado del Tratamiento , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Electrocardiografía , Ablación por Catéter , Factores de Tiempo , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...