Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Orthop Traumatol ; 25(1): 38, 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39143399

RESUMEN

BACKGROUND: Modular acetabular components for total hip arthroplasty (THA) provide intraoperative flexibility; however, polyethylene liner dissociation may occur. This study aimed to examine the incidence and causes of liner dissociation associated with a specific acetabular component design at a single centre. MATERIALS AND METHODS: A retrospective analysis of 7027 patients who underwent primary THA was performed to identify isolated liner dislocations. Patient demographics, clinical presentations, surgical and implant details, and both radiographic and computed tomography (CT) findings were analysed. Patients with liner dislocation were matched to a control group via 2:1 propensity score matching, and a logistic regression analysis was employed to identify associated risk factors. RESULTS: A total of 32 patients (0.45%) experienced liner dislocation at a mean 71.47 ± 60.10 months post surgery. Significant factors contributing to dislocations included the use of a conventional compared with a highly crosslinked polyethylene component (p = 0.049) and screw fixation (p = 0.028). Radiographic and CT analysis highlighted the importance of proper component orientation, revealing that patients experiencing dislocations demonstrated significantly lower acetabular cup anteversion angles (p = 0.001) compared with the control group. Impingement and malposition, identified in 41% and 47% of the cases, respectively, further underscored the multifactorial nature of dislocation risks. CONCLUSIONS: While the overall rate of polyethylene liner dislocation was low, the findings of this study highlight the importance of appropriate cup placement to decrease the risk of dissociation. It further substantiates the influence of impingement and malposition in liner displacement, with increased mechanical stress exerted on the locking mechanism under adverse conditions and the potential risk increase due to screw placement.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Polietileno , Diseño de Prótesis , Falla de Prótesis , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Estudios Retrospectivos , Masculino , Femenino , Prótesis de Cadera/efectos adversos , Estudios de Casos y Controles , Persona de Mediana Edad , Anciano , Factores de Riesgo , Acetábulo/cirugía , Tomografía Computarizada por Rayos X , Puntaje de Propensión
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...