Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Anal Chem ; 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38857882

RESUMEN

An ion source concept is described where the sample flow is stopped in a confined volume of an ion mobility spectrometer creating time-dependent patterns of ion patterns of signal intensities for ions from mixtures of volatile organic compounds and improved signal-to-noise rate compared to conventional unidirectional drift gas flow. Hydrated protons from a corona discharge were introduced continuously into the confined volume with the sample in air at ambient pressure, and product ions were extracted continuously using an electric field for subsequent mobility analysis. Ion signal intensities for protonated monomers and proton bound dimers were measured and computationally extracted using mobilities from mobility spectra and exhibited distinct times of appearance over 30 s or more after sample injection. Models, and experimental findings with a ternary mixture, suggest that the separation of vapors as ions over time was consistent with differences in the reaction rate for reactions between primary ions from hydrated protons and constituents and from cross-reactions that follow the initial step of ionization. The findings suggest that the concept of stopped flow, introduced here for the first time, may provide a method for the temporal separation of atmospheric pressure ions. This separation relies on ion kinetics and does not require chromatographic technology.

2.
Front Oncol ; 14: 1352509, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38746683

RESUMEN

Introduction: Brain tumors are a major source of disease burden in pediatric population, with the most common tumor types being pilocytic astrocytoma, ependymoma and medulloblastoma. In every tumor entity, surgery is the cornerstone of treatment, but the importance of gross-total resection and the corresponding patient prognosis is highly variant. However, real-time identification of pediatric CNS malignancies based on the histology of the frozen sections alone is especially troublesome. We propose a novel method based on differential mobility spectrometry (DMS) analysis for rapid identification of pediatric brain tumors. Methods: We prospectively obtained tumor samples from 15 pediatric patients (5 pilocytic astrocytomas, 5 ependymomas and 5 medulloblastomas). The samples were cut into 36 smaller specimens that were analyzed with the DMS. Results: With linear discriminant analysis algorithm, a classification accuracy (CA) of 70% was reached. Additionally, a 75% CA was achieved in a pooled analysis of medulloblastoma vs. gliomas. Discussion: Our results show that the DMS is able to differentiate most common pediatric brain tumor samples, thus making it a promising additional instrument for real-time brain tumor diagnostics.

3.
Ann Otol Rhinol Laryngol ; 132(11): 1330-1335, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36691987

RESUMEN

OBJECTIVE: Detecting bacteria as a causative pathogen of acute rhinosinusitis (ARS) is a challenging task. Electronic nose technology is a novel method for detecting volatile organic compounds (VOCs) that has also been studied in association with the detection of several diseases. The aim of this pilot study was to analyze maxillary sinus secretion with differential mobility spectrometry (DMS) and to determine whether the secretion demonstrates a different VOC profile when bacteria are present. METHODS: Adult patients with ARS symptoms were examined. Maxillary sinus contents were aspirated for bacterial culture and DMS analysis. k-Nearest neighbor and linear discriminant analysis were used to classify samples as positive or negative, using bacterial cultures as a reference. RESULTS: A total of 26 samples from 15 patients were obtained. After leave-one-out cross-validation, k-nearest neighbor produced accuracy of 85%, sensitivity of 67%, specificity of 94%, positive predictive value of 86%, and negative predictive value of 84%. CONCLUSIONS: The results of this pilot study suggest that bacterial positive and bacterial negative sinus secretion release different VOCs and that DMS has the potential to detect them. However, as the results are based on limited data, further conclusions cannot be made. DMS is a novel method in disease diagnostics and future studies should examine whether the method can detect bacterial ARS by analyzing exhaled air.


Asunto(s)
Seno Maxilar , Sinusitis , Adulto , Humanos , Seno Maxilar/microbiología , Proyectos Piloto , Nariz Electrónica , Sinusitis/diagnóstico , Sinusitis/microbiología , Bacterias , Enfermedad Aguda
4.
Curr Oncol ; 29(5): 3252-3258, 2022 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-35621655

RESUMEN

Isocitrate dehydrogenase (IDH) mutation status is an important factor for surgical decision-making: patients with IDH-mutated tumors are more likely to have a good long-term prognosis, and thus favor aggressive resection with more survival benefit to gain. Patients with IDH wild-type tumors have generally poorer prognosis and, therefore, conservative resection to avoid neurological deficit is favored. Current histopathological analysis with frozen sections is unable to identify IDH mutation status intraoperatively, and more advanced methods are therefore needed. We examined a novel method suitable for intraoperative IDH mutation identification that is based on the differential mobility spectrometry (DMS) analysis of the tumor. We prospectively obtained tumor samples from 22 patients, including 11 IDH-mutated and 11 IDH wild-type tumors. The tumors were cut in 88 smaller specimens that were analyzed with DMS. With a linear discriminant analysis (LDA) algorithm, the DMS was able to classify tumor samples with 86% classification accuracy, 86% sensitivity, and 85% specificity. Our results show that DMS is able to differentiate IDH-mutated and IDH wild-type tumors with good accuracy in a setting suitable for intraoperative use, which makes it a promising novel solution for neurosurgical practice.


Asunto(s)
Neoplasias Encefálicas , Glioma , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/cirugía , Glioma/genética , Glioma/cirugía , Humanos , Isocitrato Deshidrogenasa/genética , Mutación , Análisis Espectral
5.
Anal Chim Acta ; 1202: 339659, 2022 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-35341512

RESUMEN

The primary treatment of breast cancer is the surgical removal of the tumor with an adequate healthy tissue margin. An intraoperative method for assessing surgical margins could optimize tumor resection. Differential ion mobility spectrometry (DMS) is applicable for tissue analysis and allows for the differentiation of malignant and benign tissues. However, the number of cancer cells necessary for detection remains unknown. We studied the detection threshold of DMS for cancer cell identification with a widely characterized breast cancer cell line (BT-474) dispersed in a human myoma-based tumor microenvironment mimicking matrix (Myogel). Predetermined, small numbers of cultured BT-474 cells were dispersed into Myogel. Pure Myogel was used as a zero sample. All samples were assessed with a DMS-based custom-built device described as "the automated tissue laser analysis system" (ATLAS). We used machine learning to determine the detection threshold for cancer cell densities by training binary classifiers to distinguish the reference level (zero sample) from single predetermined cancer cell density levels. Each classifier (sLDA, linear SVM, radial SVM, and CNN) was able to detect cell density of 3700 cells µL-1 and above. These results suggest that DMS combined with laser desorption can detect low densities of breast cancer cells, at levels clinically relevant for margin detection, from Myogel samples in vitro.


Asunto(s)
Neoplasias de la Mama , Espectrometría de Movilidad Iónica , Neoplasias de la Mama/diagnóstico , Femenino , Humanos , Microambiente Tumoral
6.
Exp Mol Pathol ; 125: 104759, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35337806

RESUMEN

Pathological gross examination of breast carcinoma samples is sometimes laborious. A tissue pre-mapping method could indicate neoplastic areas to the pathologist and enable focused sampling. Differential Mobility Spectrometry (DMS) is a rapid and affordable technology for complex gas mixture analysis. We present an automated tissue laser analysis system for imaging approaches (iATLAS), which utilizes a computer-controlled laser evaporator unit coupled with a DMS gas analyzer. The system is demonstrated in the classification of porcine tissue samples and three human breast carcinomas. Tissue samples from eighteen landrace pigs were classified with the system based on a pre-designed matrix (spatial resolution 1-3 mm). The smoke samples were analyzed with DMS, and tissue classification was performed with several machine learning approaches. Porcine skeletal muscle (n = 1030), adipose tissue (n = 1329), normal breast tissue (n = 258), bone (n = 680), and liver (n = 264) were identified with 86% cross-validation (CV) accuracy with a convolutional neural network (CNN) model. Further, a panel tissue that comprised all five tissue types was applied as an independent validation dataset. In this test, 82% classification accuracy with CNN was achieved. An analogous procedure was applied to demonstrate the feasibility of iATLAS in breast cancer imaging according to 1) macroscopically and 2) microscopically annotated data with 10-fold CV and SVM (radial kernel). We reached a classification accuracy of 94%, specificity of 94%, and sensitivity of 93% with the macroscopically annotated data from three breast cancer specimens. The microscopic annotation was applicable to two specimens. For the first specimen, the classification accuracy was 84% (specificity 88% and sensitivity 77%). For the second, the classification accuracy was 72% (specificity 88% and sensitivity 24%). This study presents a promising method for automated tissue imaging in an animal model and lays foundation for breast cancer imaging.


Asunto(s)
Neoplasias de la Mama , Mama , Animales , Mama/patología , Neoplasias de la Mama/patología , Femenino , Humanos , Espectrometría de Movilidad Iónica , Rayos Láser , Análisis Espectral , Porcinos
7.
J Breath Res ; 16(1)2021 12 02.
Artículo en Inglés | MEDLINE | ID: mdl-34794137

RESUMEN

Over the last few decades, breath analysis using electronic nose (eNose) technology has become a topic of intense research, as it is both non-invasive and painless, and is suitable for point-of-care use. To date, however, only a few studies have examined nasal air. As the air in the oral cavity and the lungs differs from the air in the nasal cavity, it is unknown whether aspirated nasal air could be exploited with eNose technology. Compared to traditional eNoses, differential mobility spectrometry uses an alternating electrical field to discriminate the different molecules of gas mixtures, providing analogous information. This study reports the collection of nasal air by aspiration and the subsequent analysis of the collected air using a differential mobility spectrometer. We collected nasal air from ten volunteers into breath collecting bags and compared them to bags of room air and the air aspirated through the device. Distance and dissimilarity metrics between the sample types were calculated and statistical significance evaluated with Kolmogorov-Smirnov test. After leave-one-day-out cross-validation, a shrinkage linear discriminant classifier was able to correctly classify 100% of the samples. The nasal air differed (p< 0.05) from the other sample types. The results show the feasibility of collecting nasal air by aspiration and subsequent analysis using differential mobility spectrometry, and thus increases the potential of the method to be used in disease detection studies.


Asunto(s)
Pruebas Respiratorias , Nariz Electrónica , Aire , Pruebas Respiratorias/métodos , Humanos , Boca , Análisis Espectral
8.
Exp Mol Pathol ; 117: 104526, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32888958

RESUMEN

Pathologic examination of clinical tissue samples is time consuming and often does not involve the comprehensive analysis of the whole specimen. Automated tissue analysis systems have potential to make the workflow of a pathologist more efficient and to support in clinical decision-making. So far, these systems have been based on application of mass spectrometry imaging (MSI). MSI provides high fidelity and the results in tissue identification are promising. However, the high cost and need for maintenance limit the adoption of MSI in the clinical setting. Thus, there is a need for new innovations in the field of pathological tissue imaging. In this study, we show that differential ion mobility spectrometry (DMS) is a viable option in tissue imaging. We demonstrate that a DMS-driven solution performs with up to 92% accuracy in differentiating between two grossly distinct animal tissues. In addition, our model is able to classify the correct tissue with 81% accuracy in an eight-class setting. The DMS-based system is a significant innovation in a field dominated by mass-spectrometry-based solutions. By developing the presented platform further, DMS technology could be a cost-effective and helpful tool for automated pathological analysis.


Asunto(s)
Toma de Decisiones Clínicas , Espectrometría de Movilidad Iónica/métodos , Espectrometría de Masas/métodos , Imagen Molecular/métodos , Automatización , Humanos , Manejo de Especímenes
9.
Future Microbiol ; 15: 233-240, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32271111

RESUMEN

Aim: Rapid identification of bacteria would facilitate timely initiation of therapy and improve cost-effectiveness of treatment. Traditional methods (culture, PCR) require reagents, consumables and hours to days to complete the identification. In this study, we examined whether differential mobility spectrometry could classify most common bacterial species, genera and between Gram status within minutes. Materials & methods: Cultured bacterial sample gaseous headspaces were measured with differential mobility spectrometry and data analyzed using k-nearest-neighbor and leave-one-out cross-validation. Results: Differential mobility spectrometry achieved a correct classification rate 70.7% for all bacterial species. For bacterial genera, the rate was 77.6% and between Gram status, 89.1%. Conclusion: Largest difficulties arose in distinguishing bacteria of the same genus. Future improvement of the sensor characteristics may improve the classification accuracy.


Asunto(s)
Bacterias/aislamiento & purificación , Técnicas de Tipificación Bacteriana/métodos , Bacterias/química , Bacterias/clasificación , Bacterias/genética , Infecciones Bacterianas/microbiología , Humanos , Análisis Espectral/métodos
10.
J Neurosurg ; : 1-7, 2019 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-31200382

RESUMEN

OBJECTIVE: There is a need for real-time, intraoperative tissue identification technology in neurosurgery. Several solutions are under development for that purpose, but their adaptability for standard clinical use has been hindered by high cost and impracticality issues. The authors tested and preliminarily validated a method for brain tumor identification that is based on the analysis of diathermy smoke using differential mobility spectrometry (DMS). METHODS: A DMS connected to a special smoke sampling system was used to discriminate brain tumors and control samples ex vivo in samples from 28 patients who had undergone neurosurgical operations. They included meningiomas (WHO grade I), pilocytic astrocytomas (grade I), other low-grade gliomas (grade II), glioblastomas (grade IV), CNS metastases, and hemorrhagic or traumatically damaged brain tissue as control samples. Original samples were cut into 694 smaller specimens in total. RESULTS: An overall classification accuracy (CA) of 50% (vs 14% by chance) was achieved in 7-class classification. The CA improved significantly (up to 83%) when the samples originally preserved in Tissue-Tek conservation medium were excluded from the analysis. The CA further improved when fewer classes were used. The highest binary classification accuracy, 94%, was obtained in low-grade glioma (grade II) versus control. CONCLUSIONS: The authors' results show that surgical smoke from various brain tumors has distinct DMS profiles and the DMS analyzer connected to a special sampling system can differentiate between tumorous and nontumorous tissue and also between different tumor types ex vivo.

11.
Nanoscale Adv ; 1(10): 4025-4040, 2019 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-36132092

RESUMEN

As the Earth's atmosphere contains an abundant amount of water as vapors, a device which can capture a fraction of this water could be a cost-effective and practical way of solving the water crisis. There are many biological surfaces found in nature which display unique wettability due to the presence of hierarchical micro-nanostructures and play a major role in water deposition. Inspired by these biological microstructures, we present a large scale, facile and cost-effective method to fabricate water-harvesting functional surfaces consisting of high-density copper oxide nanoneedles. A controlled chemical oxidation approach on copper surfaces was employed to fabricate nanoneedles with controlled morphology, assisted by bisulfate ion adsorption on the surface. The fabricated surfaces with nanoneedles displayed high wettability and excellent fog harvesting capability. Furthermore, when the fabricated nanoneedles were subjected to hydrophobic coating, these were able to rapidly generate and shed coalesced droplets leading to further increase in fog harvesting efficiency. Overall, ∼99% and ∼150% increase in fog harvesting efficiency was achieved with non-coated and hydrophobic layer coated copper oxide nanoneedle surfaces respectively when compared to the control surfaces. As the transport of the harvested water is very important in any fog collection system, hydrophilic channels inspired by leaf veins were made on the surfaces via a milling technique which allowed an effective and sustainable way to transport the captured water and further enhanced the water collection efficiency by ∼9%. The system presented in this study can provide valuable insights towards the design and fabrication of fog harvesting systems, adaptable to arid or semi-arid environmental conditions.

12.
Eur J Surg Oncol ; 45(2): 141-146, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30366874

RESUMEN

INTRODUCTION: Breast cancer is the most frequent cancer in women worldwide. The primary treatment is breast-conserving surgery or mastectomy with an adequate clearance margin. Diathermy blade is used extensively in breast-conserving surgery. Surgical smoke produced as a side product has cancer-specific molecular features. Differential mobility spectrometry (DMS) is a rapid and affordable technology for analysis of complex gas mixtures. In our study we examined surgical smoke from malignant and benign breast tissue created with a diathermy blade using DMS. MATERIAL AND METHODS: Punch biopsies of 4 mm diameter from breast cancer surgical specimens were taken during gross dissection of fresh surgical specimen and placed in a well plate. The measurement system is a custom-built device called automatic tissue analysis system (ATAS) based on a DMS sensor. Each specimen was incised with a diathermy blade and the surgical smoke was analyzed. RESULTS: We examined 106 carcinoma samples from 21 malignant breast tumors. Benign samples (n = 198) included macroscopically normal mammary gland (n = 82), adipose tissue (n = 88) and vascular tissue (n = 28). The classification accuracy when comparing malignant samples to all benign samples was 87%. The sensitivity was 80% and the specificity was 90%. The classification accuracy of carcinomas to ductal and lobular was 94%, 47%, respectively. CONCLUSIONS: Benign and malignant breast tissue can be identified with ATAS. These results lay foundation for intraoperative margin assessment with DMS from surgical smoke.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/cirugía , Diatermia , Espectrometría de Movilidad Iónica , Humo/análisis , Adulto , Biopsia , Neoplasias de la Mama/patología , Diagnóstico Diferencial , Femenino , Humanos , Persona de Mediana Edad , Sensibilidad y Especificidad
13.
Anticancer Res ; 39(1): 73-79, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30591442

RESUMEN

BACKGROUND/AIM: Most pancreatic cancer patients are diagnosed at an advanced stage, since the diagnosis is demanding. Field asymmetric waveform ion mobility spectrometry (FAIMS) is a sensitive technique used for the detection of volatile organic compounds (VOC). We evaluated the ability of FAIMS to discriminate between pancreatic cancer and healthy controls from a urine sample. PATIENTS AND METHODS: For a proof-of-concept study in three Finnish hospitals, 68 patients with pancreatic cancer, 36 with acute pancreatitis, 18 with chronic pancreatitis, 8 with pancreatic pre-malign lesions and 52 healthy controls were prospectively recruited. Urine samples were collected at the time of diagnosis and stored at -70°C. The samples were subsequently measured with FAIMS. The data were processed with linear discriminant analysis and cross-validated with leave-one-out cross-validation. RESULTS: FAIMS distinguished pancreatic cancer from controls with a sensitivity of 79% and specificity of 79%. CONCLUSION: As a non-invasive and rapid urine test, FAIMS can discriminate patients with pancreatic cancer from healthy controls.


Asunto(s)
Neoplasias Pancreáticas/orina , Lesiones Precancerosas/orina , Compuestos Orgánicos Volátiles/orina , Anciano , Femenino , Humanos , Espectrometría de Movilidad Iónica/métodos , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/patología , Lesiones Precancerosas/patología , Urinálisis/métodos , Compuestos Orgánicos Volátiles/aislamiento & purificación
14.
Eur Arch Otorhinolaryngol ; 275(9): 2273-2279, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30043078

RESUMEN

Acute rhinosinusitis (ARS) is a sudden, symptomatic inflammation of the nasal and paranasal mucosa. It is usually caused by respiratory virus infection, but bacteria complicate for a small number of ARS patients. The differential diagnostics between viral and bacterial pathogens is difficult and currently no rapid methodology exists, so antibiotics are overprescribed. The electronic nose (eNose) has shown the ability to detect diseases from gas mixtures. Differential mobility spectrometry (DMS) is a next-generation device that can separate ions based on their different mobility in high and low electric fields. Five common rhinosinusitis bacteria (Streptococcus pneumoniae, Haemophilus influenzae, Moraxella catarrhalis, Staphylococcus aureus, and Pseudomonas aeruginosa) were analysed in vitro with DMS. Classification was done using linear discriminant analysis (LDA) and k-nearest neighbour (KNN). The results were validated using leave-one-out cross-validation and separate train and test sets. With the latter, 77% of the bacteria were classified correctly with LDA. The comparative figure with KNN was 79%. In one train-test set, P. aeruginosa was excluded and the four most common ARS bacteria were analysed with LDA and KNN; the correct classification rate was 83 and 85%, respectively. DMS has shown its potential in detecting rhinosinusitis bacteria in vitro. The applicability of DMS needs to be studied with rhinosinusitis patients.


Asunto(s)
Nariz Electrónica , Bacilos y Cocos Aerobios Gramnegativos/aislamiento & purificación , Haemophilus influenzae/aislamiento & purificación , Rinitis/microbiología , Sinusitis/microbiología , Staphylococcus aureus/aislamiento & purificación , Streptococcus pneumoniae/aislamiento & purificación , Enfermedad Aguda , Humanos , Análisis Espectral
15.
Ann Biomed Eng ; 46(8): 1091-1100, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29691788

RESUMEN

Electrosurgery is widely used in various surgical operations. When tissue is cut with high-frequency current, the cell contents at the incision area evaporate and together with water and possible soot particles, form surgical smoke. The smoke contains cell metabolites, and therefore, possible biomarkers for cancer or bacterial infection. Thus, the analysis of surgical smoke could be used in intraoperative medical diagnostics. We present a method that can be used to detect the characteristics of various tissue types by means of differential ion mobility spectrometry (DMS) analysis of surgical smoke. We used our method to test tissue identification with ten different porcine tissues. We classified the DMS responses with cross-validated linear discriminant analysis models. The classification accuracy in a measurement set with ten tissue types was 95%. The presented tissue identification by DMS analysis of surgical smoke is a proof-of-concept, which opens the possibility to research the method in diagnosing human tissues and diseases in the future.


Asunto(s)
Electrocirugia , Espectrometría de Movilidad Iónica , Humo/análisis , Animales , Humanos , Cuidados Intraoperatorios/instrumentación , Cuidados Intraoperatorios/métodos , Porcinos
16.
PLoS One ; 13(4): e0195274, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29649244

RESUMEN

Electrosurgery produces surgical smoke. Different tissues produce different quantities and types of smoke, so we studied the particle characteristics of this surgical smoke in order to analyze the implications for the occupational health of the operation room personnel. We estimated the deposition of particulate matter (PM) from surgical smoke on the respiratory tract of operation room personnel using clinically relevant tissues from Finnish landrace porcine tissues including skeletal muscle, liver, subcutaneous fat, renal pelvis, renal cortex, lung, bronchus, cerebral gray and white matter, and skin. In order to standardize the electrosurgical cuts and smoke concentrations, we built a customized computer-controlled platform. The smoke particles were analyzed with an electrical low pressure impactor (ELPI), which measures the concentration and aerodynamic size distribution of particles with a diameter between 7 nm and 10 µm. There were significant differences in the mass concentration and size distribution of the surgical smoke particles depending on the electrocauterized tissue. Of the various tissues tested, liver yielded the highest number of particles. In order to better estimate the health hazard, we propose that the tissues can be divided into three distinct classes according to their surgical smoke production: 1) high-PM tissue for liver; 2) medium-PM tissues for renal cortex, renal pelvis, and skeletal muscle; and 3) low-PM tissues for skin, gray matter, white matter, bronchus, and subcutaneous fat.


Asunto(s)
Electricidad , Exposición Profesional/efectos adversos , Exposición Profesional/análisis , Seguridad , Humo/efectos adversos , Humo/análisis , Procedimientos Quirúrgicos Operativos/efectos adversos , Animales , Salud Laboral , Porcinos
17.
Eur Surg Res ; 59(1-2): 1-11, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29320769

RESUMEN

BACKGROUND: Soft tissue infections, including postoperative wound infections, result in a significant burden for modern society. Rapid diagnosis of wound infections is based on bacterial stains, cultures, and polymerase chain reaction assays, and the results are available earliest after several hours, but more often not until days after. Therefore, antibiotic treatment is often administered empirically without a specific diagnosis. METHODS: We employed our electronic nose (eNose) system for this proof-of-concept study, aiming to differentiate the most relevant bacteria causing wound infections utilizing a set of clinical bacterial cultures on identical blood culture dishes, and established bacterial lines from the gaseous headspace. RESULTS: Our eNose system was capable of differentiating both methicillin-sensitive Staphylococcus aureus (MSSA) and methicillin-resistant Staphylococcus aureus (MRSA), Streptococcus pyogenes, Escherichia coli, Pseudomonas aeruginosa, and Clostridium perfringens with an accuracy of 78% within minutes without prior sample preparation. Most importantly, the system was capable of differentiating MRSA from MSSA with a sensitivity of 83%, a specificity of 100%, and an overall accuracy of 91%. CONCLUSIONS: Our results support the concept of rapid detection of the most relevant bacteria causing wound infections and ultimately differentiating MRSA from MSSA utilizing gaseous headspace sampling with an eNose.


Asunto(s)
Bacterias/aislamiento & purificación , Nariz Electrónica , Infección de Heridas/microbiología , Humanos , Staphylococcus aureus Resistente a Meticilina/aislamiento & purificación
18.
PLoS One ; 9(12): e114279, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25526592

RESUMEN

UNLABELLED: Urinary tract infection (UTI) is a common disease with significant morbidity and economic burden, accounting for a significant part of the workload in clinical microbiology laboratories. Current clinical chemisty point-of-care diagnostics rely on imperfect dipstick analysis which only provides indirect and insensitive evidence of urinary bacterial pathogens. An electronic nose (eNose) is a handheld device mimicking mammalian olfaction that potentially offers affordable and rapid analysis of samples without preparation at athmospheric pressure. In this study we demonstrate the applicability of ion mobility spectrometry (IMS) -based eNose to discriminate the most common UTI pathogens from gaseous headspace of culture plates rapidly and without sample preparation. We gathered a total of 101 culture samples containing four most common UTI bacteries: E. coli, S. saprophyticus, E. faecalis, Klebsiella spp and sterile culture plates. The samples were analyzed using ChemPro 100i device, consisting of IMS cell and six semiconductor sensors. Data analysis was conducted by linear discriminant analysis (LDA) and logistic regression (LR). The results were validated by leave-one-out and 5-fold cross validation analysis. In discrimination of sterile and bacterial samples sensitivity of 95% and specificity of 97% were achieved. The bacterial species were identified with sensitivity of 95% and specificity of 96% using eNose as compared to urine bacterial cultures. IN CONCLUSION: These findings strongly demonstrate the ability of our eNose to discriminate bacterial cultures and provides a proof of principle to use this method in urinanalysis of UTI.


Asunto(s)
Nariz Electrónica , Urinálisis/métodos , Infecciones Urinarias/microbiología , Estudios de Casos y Controles , Humanos , Microbiota , Sensibilidad y Especificidad , Urinálisis/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA