1.
Orthopade ; 51(1): 29-35, 2022 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-34919162

RESUMEN

The complex kinematics of the saddle joint has been a challenge in the development of trapeziometacarpal prostheses. The introduction of the dual-mobility design increases the range of motion and limits strains on the cup fixation. Therefore, rates of loosening and dislocation have been markedly reduced. Furthermore, several studies showed a similar relief of pain, range of movement and grip strength compared to the results of resection arthroplasty. The preservation of the length of the first ray as well as the more stable and functional joint can be favourable in younger and active patients. Further investigation is needed to determine whether or not those higher demands affect long-term survivorship. The high grade of patient satisfaction, the shorter recovery time and the safe surgical technique motivates considering the implantation of a total endoprosthesis with a dual-mobility cup as an attractive alternative to resection arthroplasty in the operative treatment for trapeziometacarpal osteoarthritis.


Asunto(s)
Artroplastia de Reemplazo , Articulaciones Carpometacarpianas , Prótesis Articulares , Hueso Trapecio , Artroplastia , Articulaciones Carpometacarpianas/diagnóstico por imagen , Articulaciones Carpometacarpianas/cirugía , Estudios de Seguimiento , Humanos , Rango del Movimiento Articular , Pulgar/diagnóstico por imagen , Pulgar/cirugía , Hueso Trapecio/cirugía
2.
Int Orthop ; 42(8): 1835-1843, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29392383

RESUMEN

PURPOSE: Opening wedge high tibial osteotomy (HTO) as a treatment in unicompartimental osteoarthritis of the knee can significantly relieve pain and prevent or at least delay an early joint replacement. The fixation of the osteotomy has undergone development and refinements during the last years. The angle-stable plate fixator is currently one of the most commonly used plates in HTOs. The angular stable fixation between screws and the plate offers a high primary stability to retain the correction with early weight-bearing protocols. This surgical technique is performed as a standard of care and generally well tolerated by the patients. Nevertheless, some studies observed that many patients complained about discomfort related to the implant. METHODS: Therefore, the stability of two different intramedullary nails, a short implant used in humeral fractures and a long device used in tibial fractures for stabilization in valgus HTOs, was investigated as an alternative fixation technique. The plate fixator was defined as reference standard. Nine synthetic tibia models were standardly osteotomized and stabilized by one of the fixation devices. Axial compression was realized using a special testing machine and two protocols were performed: a multi-step fatigue test and a load-to-failure test. RESULTS: Overall motion, medial, and lateral displacements were documented. Fractures always occurred at the lateral cortex. Axial cyclic loading up to 800 N was tolerated by all implants without failure. The tibia nail provided highest fatigue strength under the load-to-failure conditions. CONCLUSIONS: The results suggest that intramedullary nailing might be used as an alternative concept in HTO.


Asunto(s)
Clavos Ortopédicos/efectos adversos , Fijación Intramedular de Fracturas/métodos , Osteotomía/métodos , Diseño de Prótesis/efectos adversos , Fracturas de la Tibia/cirugía , Fenómenos Biomecánicos , Placas Óseas , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/instrumentación , Humanos , Articulación de la Rodilla/cirugía , Modelos Anatómicos , Osteoartritis de la Rodilla/cirugía , Osteotomía/efectos adversos , Falla de Prótesis , Tibia/cirugía
3.
Tissue Eng Part C Methods ; 16(5): 877-86, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19891540

RESUMEN

An effective isolation protocol for outgrowth endothelial cells (OEC) resulting in higher cell numbers and a reduced expansion time would facilitate the therapeutical application. In this study a standard protocol based on the isolation of mononuclear cells from adult peripheral blood was modified by adding a passaging step 7 days after the isolation. OEC colonies gained by both protocols were evaluated after 28 days and resulted in different frequencies of OEC colonies depending on the donor and culture protocol. Accordingly, we defined two groups, namely, high colony-forming cultures (HCC) and low colony-forming cultures (LCC) for further analysis. LCC revealed no increase in OEC colonies by the modified protocol, whereas in HCC the frequency of OEC colonies was significantly improved by the passaging step. Quantitative real-time polymerase chain reaction, flow cytometry, and immunofluorescence for endothelial markers indicated an enrichment of OEC by protocol modification in HCC. In addition, HCC revealed higher expression of CD34 and CD133 compared to LCC and resulted in higher numbers of OEC gained per donor, which was further improved by the modified protocol. We conclude that the modified protocol supports the selection of OEC from adult peripheral blood with a high clonogenic potential and results in a better efficacy in OEC isolation.


Asunto(s)
División Celular , Endotelio/química , Células Madre/citología , Proliferación Celular , Células Cultivadas , Citometría de Flujo , Técnica del Anticuerpo Fluorescente , Expresión Génica , Humanos , Reacción en Cadena de la Polimerasa