Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Clin Pharmacol Ther ; 115(1): 42-51, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37597239

RESUMEN

Nirmatrelvir is a potent and selective severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) main protease inhibitor. Nirmatrelvir co-packaged with ritonavir (as PAXLOVID) received US Food and Drug Administration (FDA) Emergency Use Authorization (EUA) on December 22, 2021, as an oral treatment for coronavirus disease 2019 (COVID-19) and subsequent new drug application approval on May 25, 2023. Pharmacokinetic (PK) capillary blood sampling at-home using Tasso-M20 micro-volumetric sampling device was implemented in the program, including three phase II/III outpatient and several clinical pharmacology studies supporting the EUA. The at-home sampling complemented venous blood sampling procedures to enrich the PK dataset, to decrease the need for patients' site visit for PK sampling, and to allow different sampling approaches for flexibility and convenience. To demonstrate concordance/equivalence, bridging between venous plasma and Tasso dried blood results was conducted by comparing concentrations and derived PK parameters from both sampling approaches. In addition, a two-compartment population PK model was utilized to bridge the plasma and Tasso data by estimating the PK parameters using blood-to-plasma ratio as a slope parameter. Operational challenges were successfully managed to implement at-home PK sampling in global phase II/III trials. Sample quality was generally very good with less than 3% samples deemed as "not usable" from over 800 samples collected in all the studies. Experience gained from sites and patients will guide future broader implementations.


Asunto(s)
Lactamas , Ritonavir , Estados Unidos , Humanos , Leucina , Atención Dirigida al Paciente
2.
Bioanalysis ; 15(17): 1083-1094, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37584365

RESUMEN

Aim: A sensitive and selective method for the determination of PF-07059013 in dried blood collected by Mitra™ tips was developed and qualified from 50 to 50,000 ng/ml. Materials & methods: PF-07059013 is isolated from 10 µl of human dried blood by extraction with methanol and analyzed by HPLC-MS/MS. Results & conclusions: In addition to routine validation elements, impact of hematocrit and Mitra tip's lot-to-lot variation on assay accuracy were evaluated. The qualified method was used in one clinical study with excellent performance. Correlation coefficient between blood concentrations obtained from liquid-incurred blood samples and dried-incurred blood samples is 0.95. Clinical Trial Registration: NCT04323124 (ClinicalTrials.gov).


Asunto(s)
Pruebas con Sangre Seca , Espectrometría de Masas en Tándem , Humanos , Espectrometría de Masas en Tándem/métodos , Pruebas con Sangre Seca/métodos , Manejo de Especímenes , Cromatografía Líquida de Alta Presión/métodos , Hematócrito
3.
Bioanalysis ; 14(20): 1305-1315, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36541270

RESUMEN

Aim: A sensitive and selective method for the determination of nirmatrelvir in dried human blood collected by Tasso-M20 was developed and validated from 20.0 to 20,000 ng/ml. Materials & methods: Nirmatrelvir and its stable-labeled internal standard were isolated from approximately 20 µl of blood dried on one volumetric absorptive pad inside the Tasso-M20 device by extraction with methanol, followed by dilution of the supernatant. The extracts were analyzed by high-performance liquid chromatography coupled with tandem mass spectrometric detection. Results & conclusion: The method was fully validated. Hematocrit levels do not impact assay accuracy. Stabilities to cover sample drying and storage at a variety of conditions were conducted. The validated method was used in multiple clinical studies with excellent performance.


Asunto(s)
Pruebas con Sangre Seca , Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida/métodos , Pruebas con Sangre Seca/métodos , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Lactamas , Reproducibilidad de los Resultados
4.
Clin Transl Sci ; 15(12): 2785-2795, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36129129

RESUMEN

Advances in the technologies to enable patient-centric sampling (PCS) have the potential to improve blood sample collection by enabling clinical trial participants to collect samples via self-collection or with the help of a caregiver in their home. Typically, blood samples to assess pharmacokinetics and pharmacodynamics of a drug during clinical development are collected at a clinical site via venous blood draw. In this position paper by the International Consortium for Innovation and Quality in Pharmaceutical Development (IQ), the potential value PCS can bring to patients, to the clinical datasets generated, and to clinical trial sponsors is discussed, along with considerations for program decision making, bioanalytical feasibility, operations, and regulatory implications. With an understanding of the value of PCS and considerations when implementing during clinical drug development, we can bring the promise of PCS closer to reality and enable decentralized clinical trials.


Asunto(s)
Desarrollo de Medicamentos , Atención Dirigida al Paciente , Humanos
5.
Clin Pharmacol Ther ; 112(4): 892-900, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35712797

RESUMEN

Nirmatrelvir coadministered with ritonavir is highly efficacious in reducing the risk of coronavirus disease 2019 (COVID-19) adverse outcomes among patients at increased risk of progression to severe disease, including patients with chronic kidney disease. Because nirmatrelvir is eliminated by the kidneys when given with ritonavir, this phase I study evaluated the effects of renal impairment on pharmacokinetics, safety, and tolerability of nirmatrelvir/ritonavir. Participants with normal renal function (n = 10) or mild, moderate, or severe renal impairment (n = 8 each) were administered a single 100-mg nirmatrelvir dose with 100 mg ritonavir given 12 hours before, together with and 12 and 24 hours after the nirmatrelvir dose. Systemic nirmatrelvir exposure increased with increasing renal impairment, with mild, moderate, and severe renal impairment groups having respective adjusted geometric mean ratio areas under the plasma concentration-time profile from time 0 extrapolated to infinite time of 124%, 187%, and 304% vs. the normal renal function group. Corresponding ratios for maximum plasma concentration were 130%, 138%, and 148%. Apparent clearance was positively correlated with estimated glomerular filtration rate, and geometric mean renal clearance values were particularly lower for the moderate (47% decrease) and severe (80% decrease) renal impairment groups vs. the normal renal function group. Nirmatrelvir/ritonavir exhibited an acceptable safety profile; treatment-related adverse events were mild in severity, and there were no significant findings regarding laboratory measurements, vital signs, or electrocardiogram assessments. These findings led to a dose reduction recommendation for nirmatrelvir/ritonavir in patients with moderate renal impairment (150/100 mg nirmatrelvir/ritonavir instead of 300/100 mg twice daily for 5 days). NCT04909853.


Asunto(s)
Tratamiento Farmacológico de COVID-19 , Insuficiencia Renal , Antivirales/efectos adversos , Inhibidores Enzimáticos , Humanos , Inhibidores de Proteasas , Ritonavir/efectos adversos
6.
Bioanalysis ; 14(9): 505-580, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35578993

RESUMEN

The 15th edition of the Workshop on Recent Issues in Bioanalysis (15th WRIB) was held on 27 September to 1 October 2021. Even with a last-minute move from in-person to virtual, an overwhelmingly high number of nearly 900 professionals representing pharma and biotech companies, contract research organizations (CROs), and multiple regulatory agencies still eagerly convened to actively discuss the most current topics of interest in bioanalysis. The 15th WRIB included 3 Main Workshops and 7 Specialized Workshops that together spanned 1 week in order to allow exhaustive and thorough coverage of all major issues in bioanalysis, biomarkers, immunogenicity, gene therapy, cell therapy and vaccines. Moreover, in-depth workshops on biomarker assay development and validation (BAV) (focused on clarifying the confusion created by the increased use of the term "Context of Use - COU"); mass spectrometry of proteins (therapeutic, biomarker and transgene); state-of-the-art cytometry innovation and validation; and, critical reagent and positive control generation were the special features of the 15th edition. This 2021 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2021 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 1A) covers the recommendations on Endogenous Compounds, Small Molecules, Complex Methods, Regulated Mass Spec of Large Molecules, Small Molecule, PoC. Part 1B covers the Regulatory Agencies' Inputs on Bioanalysis, Biomarkers, Immunogenicity, Gene & Cell Therapy and Vaccine. Part 2 (ISR for Biomarkers, Liquid Biopsies, Spectral Cytometry, Inhalation/Oral & Multispecific Biotherapeutics, Accuracy/LLOQ for Flow Cytometry) and Part 3 (TAb/NAb, Viral Vector CDx, Shedding Assays; CRISPR/Cas9 & CAR-T Immunogenicity; PCR & Vaccine Assay Performance; ADA Assay Comparabil ity & Cut Point Appropriateness) are published in volume 14 of Bioanalysis, issues 10 and 11 (2022), respectively.


Asunto(s)
Vesículas Extracelulares , Vacunas , Biomarcadores/análisis , Tratamiento Basado en Trasplante de Células y Tejidos , Vesículas Extracelulares/química , Humanos , Espectrometría de Masas/métodos , Nanomedicina
7.
Bioanalysis ; 13(19): 1477-1486, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34601943

RESUMEN

Aims: A chiral HPLC-MS/MS method for quantitation of an active metabolite (M2) of abrocitinib was validated in human plasma. Methods: Protein precipitation extraction and normal phase LC with baseline separation of five analytes (abrocitinib; isomeric metabolites M1, M2, M3 and M4) were achieved followed by mass spectrometric quantitation of M2 using positive-mode APCI. Results: With a 5-5000 ng/ml assay range using 100 µl K2EDTA aliquot, the assay provided short (17-min) runtime and robust separation up to approximately 330 injections on one column. Interday and intraday accuracy ranged from -6.80% to 13.4%; between-day and within-day precision was ≤10.4%. Conclusion: The method was used in multiple clinical studies, with excellent run passing rate and incurred sample reproducibility.


Asunto(s)
Pirimidinas , Sulfonamidas
8.
Bioanalysis ; 11(23): 2099-2132, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31833782

RESUMEN

The 2019 13th Workshop on Recent Issues in Bioanalysis (WRIB) took place in New Orleans, LA on 1-5 April 2019 with an attendance of over 1000 representatives from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5-day, week-long event - a full immersion week of bioanalysis, biomarkers, immunogenicity and gene therapy. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small- and large-molecule bioanalysis involving LCMS, hybrid LBA/LCMS, LBA cell-based/flow cytometry assays and qPCR approaches. This 2019 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2019 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 2) covers the recommendations on the 2018 FDA BMV guidance, 2019 ICH M10 BMV draft guideline and regulatory agencies' input on bioanalysis, biomarkers, immunogenicity and gene therapy. Part 1 (Innovation in small molecules and oligonucleotides and mass spectrometry method development strategies for large molecules bioanalysis) and Part 3 (New insights in biomarker assay validation, current and effective strategies for critical reagent management, flow cytometry validation in drug discovery and development and CLSI H62, interpretation of the 2019 FDA immunogenicity guidance and gene therapy bioanalytical challenges) are published in volume 10 of Bioanalysis, issues 22 and 24 (2019), respectively.


Asunto(s)
Bioensayo/normas , Biomarcadores/análisis , Guías como Asunto , Fenómenos Inmunogenéticos , Informe de Investigación , United States Food and Drug Administration/legislación & jurisprudencia , Humanos , Estados Unidos
9.
Bioanalysis ; 9(22): 1807-1825, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29148835

RESUMEN

The 2017 11th Workshop on Recent Issues in Bioanalysis (11th WRIB) took place in Los Angeles/Universal City, California from 3 April 2017 to 7 April 2017 with participation of close to 750 professionals from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5-day, weeklong event - A Full Immersion Week of Bioanalysis, Biomarkers and Immunogenicity. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small and large molecule analysis involving LCMS, hybrid LBA/LCMS and ligand-binding assay (LBA) approaches. This 2017 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2017 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 1) covers the recommendations for Small Molecules, Peptides and Small Molecule Biomarkers using LCMS. Part 2 (Biotherapeutics, Biomarkers and Immunogenicity Assays using Hybrid LBA/LCMS and Regulatory Agencies' Inputs) and Part 3 (LBA: Immunogenicity, Biomarkers and PK Assays) are published in volume 9 of Bioanalysis, issues 23 and 24 (2017), respectively.


Asunto(s)
Biomarcadores/análisis , Cromatografía Líquida de Alta Presión , Espectrometría de Masas , Péptidos/análisis , Bibliotecas de Moléculas Pequeñas/análisis , Conferencias de Consenso como Asunto , Guías como Asunto , Ligandos , Bibliotecas de Moléculas Pequeñas/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA