Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Adv Mater ; : e2306568, 2023 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-37677058

RESUMEN

Wide-bandgap (WBG) perovskites have attracted considerable attention due to their adjustable bandgap properties, making them ideal candidates for top subcells in tandem solar cells (TSCs). However, WBG perovskites often face challenges such as inhomogeneous crystallization and severe nonradiative recombination loss, leading to high open-circuit voltage (VOC ) deficits and poor stability. To address these issues, a multifunctional phenylethylammonium acetate (PEAAc) additive that enhances uniform halide phase distribution and reduces defect density in perovskite films by regulating the mixed-halide crystallization rate, is introduced. This approach successfully develops efficient WBG perovskite solar cells (PSCs) with reduced VOC loss and enhanced stability. By applying this universal strategy to the FAMACsPb(I1- x Brx )3 system with a range of bandgaps of 1.73, 1.79, 1.85, and 1.92 eV, power conversion efficiencies (PCE) of 21.3%, 19.5%, 18.1%, and 16.2%, respectively, are attained. These results represent some of the highest PCEs reported for the corresponding bandgaps. Furthermore, integrating WBG perovskite with organic photovoltaics, an impressive PCE of over 24% for two-terminal perovskite/organic TSCs, with a record VOC of ≈ 2.2 V is achieved. This work establishes a foundation for addressing phase separation and inhomogeneous crystallization in Br-rich perovskite components, paving the way for the development of high-performance WBG PSCs and TSCs.

2.
Micromachines (Basel) ; 10(11)2019 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-31717824

RESUMEN

We applied a thermal-desorption gas-chromatograph mass-spectrometer (TD-GC-MS) system to identify the marker volatile organic compounds (VOCs) in the aroma of red wine. After obtaining the marker VOC, we utilized surface acoustic waves (SAWs) to develop a highly sensitive sensing system as 'electronic nose' to detect these marker VOC. The SAW chips were fabricated on a LiNbO3 substrate with a lithographic process. We coated sensing polymers on the sensing area to adsorb the marker VOC in a sample gas. The adsorption of the marker VOC altered the velocity of the SAW according to a mass-loading effect, causing a frequency decrease. This experiment was conducted with wines of three grape varieties-cabernet sauvignon, merlot and black queen. According to the results of TD-GC-MS, the King brand of red wine is likely to have unique VOC, which are 2-pentanone, dimethyl disulfide, 2-methylpropyl acetate and 2-pentanol; Blue Nun-1 probably has a special VOC such as 2,3-butanedione. We hence used a SAW sensor array to detect the aroma of red wines and to distinguish their components by their frequency shift. The results show that the use of polyvinyl butyral (PVB) as a detecting material can distinguish Blue Nun-2 from the others and the use of polyvinyl alcohol (PVA) can distinguish King from the others. We conducted random tests to prove the accuracy and the reliability of our SAW sensors.

3.
Biomed Mater ; 15(1): 015005, 2019 12 09.
Artículo en Inglés | MEDLINE | ID: mdl-31634880

RESUMEN

Using three-dimensional (3D) bone engineering to fabricate bone segments is a better choice for repairing bone defects than using autologous bone. However, biomaterials for bone engineering are burdened with some clinical safety concerns. In this study, we layered commonly found clinical materials, hemostatic gelatin sponges, in a novel manner to create a 3D scaffold for bone engineering purposes. We further examined the comparable benefits of our design with both closed- and open-bottom holders. Cells in stacked layer disc systems were examined after a week of growth and differentiation. Osteoblasts in the outer layers of both closed- and open-bottom holder systems displayed gradually increased alkaline phosphatase (ALP) activity but decreased osteopontin (OPN) expression. Further, cell proliferation assays and LIVE/DEAD staining revealed decreased viable cell counts in the top layer with increased incubation time. However, while layered disc systems with closed-bottom holders underwent differentiation, they kept more differentiated cells alive within the gelatin sponge disc scaffold after 28 d of culturing. Whether cells were inoculated into the top, middle, or bottom portions of the layered disc stack, osteoblasts showed a preference for migrating to the top layer, in keeping with the oxygen and nutrients gradients. Regarding practical application, this study offers valuable information to promote the use of hemostatic gelatin sponges for bone engineering.


Asunto(s)
Osteoblastos/citología , Ingeniería de Tejidos/métodos , Andamios del Tejido/química , Células 3T3 , Animales , Materiales Biocompatibles/química , Trasplante Óseo/métodos , Diferenciación Celular , Movimiento Celular , Supervivencia Celular , Espuma de Fibrina/química , Gelatina/química , Esponja de Gelatina Absorbible/química , Hemostáticos/química , Humanos , Ensayo de Materiales , Ratones , Osteoblastos/fisiología , Osteogénesis/fisiología
4.
Micromachines (Basel) ; 9(8)2018 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-30424331

RESUMEN

A device to monitor particulate matter of size 2.5 µm (PM2.5) that has been designed and developed includes a surface-acoustic-wave sensor operating in a shear horizontal mode (SH-SAW) combined with a cyclone separator. In our tests, aerosols generated as incense smoke were first separated and sampled inside a designed cyclone separator; the sampled PM2.5 was then introduced into the sensing area of an SH-SAW sensor for detection. The use of microcentrifuge tubes as a cyclone separator effectively decreases the size and power consumption of the device; the SAW sensor in a well design and operating at 122 MHz was fabricated with MEMS techniques. After an explanation of the design of the cyclone separator, a simulation of the efficiency and the SAW sensor detection are discussed. A microcentrifuge tube (volume 0.2 mL, inlet and outlet diameters 0.5 mm) as a separator has separation cutoff diameters 50% (d50) at 2.5 µm; the required rate of volumetric flow at the inlet is 0.125 LPM, according to simulation with computational fluid dynamics (CFD) software; the surface-acoustic-wave (SAW) sensor exhibits sensitivity approximately 9 Hz/ng; an experiment for PM2.5 detection conducted with the combined device shows a strong positive linear correlation with a commercial aerosol monitor. The limit of detection (LOD) is 11 µg/m³ with sample time 160 s and total detection duration about 5 min.

5.
Lab Chip ; 18(1): 106-114, 2017 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-29211085

RESUMEN

A cancer immunotherapy µ-environment LabChip, equipped with titanium oxide phthalocyanine (TiOPc)-based optoelectronic tweezers (OET) to achieve direct cell-cell contact, can be used to study the interaction between immune cells and other cells for real-time analysis of NK cells' behavior. In microfluidic devices, it is difficult to solve dead zone problems and observe dynamic cell-cell interactions. We have created a stable and static culture µ-environment which can enhance NK cell activities. In addition, OET is used to solve dead zone problems by manipulating a single cell into four-leaf-clover-shaped (FLCS) microwells made of poly(ethylene glycol) diacrylate (PEG-DA) through optofluidic maskless lithography, causing direct cell-cell contact. Our design reconstructed an in vitro human immune system for the study of dynamic immunological response. When the NK cells came into contact with the target cells in the µ-environment LabChip, we observed that the target cells showed apoptotic characteristics (i.e. cell shrinkage and blebbing within 2 h and then die within 3 h). In addition, our µ-environment LabChip demonstrated higher NK cell activity compared with conventional analysis. We have created an innovative cancer immunotherapy µ-environment LabChip to provide a stable and static µ-environment for cell-cell interaction study. Furthermore, our µ-environment LabChip showed the potential to enhance NK cell activity and to study immunological interactions between immune cells and cancer cells dynamically.


Asunto(s)
Inmunoterapia , Dispositivos Laboratorio en un Chip , Modelos Biológicos , Pinzas Ópticas , Microambiente Tumoral , Animales , Antineoplásicos/farmacología , Apoptosis/efectos de los fármacos , Apoptosis/inmunología , Línea Celular , Diseño de Equipo , Humanos , Células K562 , Células Asesinas Naturales/efectos de los fármacos , Células Asesinas Naturales/inmunología , Ratones , Microambiente Tumoral/efectos de los fármacos , Microambiente Tumoral/inmunología
6.
Artículo en Inglés | MEDLINE | ID: mdl-21096657

RESUMEN

This work proposes an innovative textile sensor system to monitor dynamic body movement and human posture by attaching wearable digital sensors to analyze body motion. The proposed system can display and analyze signals when individuals are walking, running, veering around, walking up and down stairs, as well as falling down with a wearable monitoring system, which reacts to the coordination between the body and feet. Several digital sensor designs are embedded in clothing and wear apparel. Any pressure point can determine which activity is underway. Importantly, wearable digital sensors and a wearable monitoring system allow adaptive, real-time postures, real time velocity, acceleration, non-invasive, transmission healthcare, and point of care (POC) for home and non-clinical environments.


Asunto(s)
Aceleración , Accidentes por Caídas/prevención & control , Vestuario , Manometría/instrumentación , Monitoreo Ambulatorio/instrumentación , Movimiento/fisiología , Textiles , Transductores , Diseño de Equipo , Análisis de Falla de Equipo , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...