Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
J Am Heart Assoc ; 13(11): e032465, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38804218

RESUMEN

BACKGROUND: New methods to identify patients who benefit from a primary prophylactic implantable cardioverter-defibrillator (ICD) are needed. T-wave alternans (TWA) has been shown to associate with arrhythmogenesis of the heart and sudden cardiac death. We hypothesized that TWA might be associated with benefit from ICD implantation in primary prevention. METHODS AND RESULTS: In the EU-CERT-ICD (European Comparative Effectiveness Research to Assess the Use of Primary Prophylactic Implantable Cardioverter-Defibrillators) study, we prospectively enrolled 2327 candidates for primary prophylactic ICD. A 24-hour Holter monitor reading was taken from all recruited patients at enrollment. TWA was assessed from Holter monitoring using the modified moving average method. Study outcomes were all-cause death, appropriate shock, and survival benefit. TWA was assessed both as a contiguous variable and as a dichotomized variable with cutoff points <47 µV and <60 µV. The final cohort included 1734 valid T-wave alternans samples, 1211 patients with ICD, and 523 control patients with conservative treatment, with a mean follow-up time of 2.3 years. TWA ≥60 µV was a predicter for a higher all-cause death in patients with an ICD on the basis of a univariate Cox regression model (hazard ratio, 1.484 [95% CI, 1.024-2.151]; P=0.0374; concordance statistic, 0.51). In multivariable models, TWA was not prognostic of death or appropriate shocks in patients with an ICD. In addition, TWA was not prognostic of death in control patients. In a propensity score-adjusted Cox regression model, TWA was not a predictor of ICD benefit. CONCLUSIONS: T-wave alternans is poorly prognostic in patients with a primary prophylactic ICD. Although it may be prognostic of life-threatening arrhythmias and sudden cardiac death in several patient populations, it does not seem to be useful in assessing benefit from ICD therapy in primary prevention among patients with an ejection fraction of ≤35%.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Electrocardiografía Ambulatoria , Prevención Primaria , Humanos , Prevención Primaria/métodos , Masculino , Femenino , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Electrocardiografía Ambulatoria/métodos , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Medición de Riesgo/métodos , Factores de Riesgo , Arritmias Cardíacas/terapia , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/prevención & control , Arritmias Cardíacas/mortalidad , Resultado del Tratamiento , Valor Predictivo de las Pruebas , Factores de Tiempo , Europa (Continente)/epidemiología , Pronóstico , Frecuencia Cardíaca/fisiología
2.
Heart Rhythm ; 2024 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-38597856

RESUMEN

BACKGROUND: Data on the prognostic significance of temporal variability of spatial heterogeneity of electrocardiographic repolarization in coronary artery disease (CAD) are limited. OBJECTIVE: The purpose of this study was to evaluate the prognostic value of temporal variability of T-wave morphology analyzed from a 5-minute resting electrocardiogram in CAD. METHODS: The standard deviation (SD) of T-wave morphology dispersion (TMD-SD) and the SD of total cosine R-to-T were analyzed on a beat-to-beat basis from a 5-minute period of the standard resting 12-lead electrocardiogram obtained before the clinical stress test in 1702 patients with angiographically verified CAD and well-preserved left ventricular function. RESULTS: During an average of 8.7 ± 2.2 years of follow-up, 60 patients experienced sudden cardiac death/arrest (SCD/SCA) (3.5%), 69 patients nonsudden cardiac death (NSCD) (4.1%), and 161 patients noncardiac death (9.5%). TMD-SD was significantly higher in patients who experienced SCD/SCA than in other patients (1.72 ± 2.00 vs 1.12 ± 1.75; P = .01) and higher in patients who succumbed to NSCD than in other patients (1.57 ± 1.74 vs 1.12 ± 1.76; P = .04), but it did not differ significantly between patients who experienced noncardiac death and those without such an event (1.16 ± 1.42 vs 1.14 ± 1.79; P = .86). In the Cox multivariable hazards model, TMD-SD retained its significant association with the risk of SCD/SCA (hazard ratio 1.119; 95% confidence interval 1.015-1.233; P = .024) but not with the risk of NSCD (hazard ratio 1.089; 95% confidence interval 0.983-1.206; P = .103). CONCLUSION: TMD-SD is independently associated with the long-term risk of SCD/SCA in patients with CAD.

3.
Europace ; 25(3): 820-827, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36635858

RESUMEN

AIMS: To evaluate the relationship between spatial heterogeneity of electrocardiographic repolarization and spatial heterogeneity of atrial depolarization with arrhythmic substrate represented by left ventricular fibrosis. METHODS AND RESULTS: We assessed the associations of T- and P-wave morphology parameters analysed from the standard 12-lead electrocardiograms with left ventricular fibrosis in 378 victims of unexpected sudden cardiac death (SCD) who underwent medico-legal autopsy. Based on autopsy findings, the SCD victims were categorized into four different groups according to different stages of severity of left ventricular fibrosis (substantial fibrosis, moderate patchy fibrosis, scattered mild fibrosis, no fibrosis). T-wave and P-wave area dispersion (TWAd: 0.0841 ± 0.496, 0.170 ± 0.492, 0.302 ± 404, 0.296 ± 0.476, P = 0.008; PWAd: 0.574 ± 0.384, 0.561 ± 0.367, 0.654 ± 0.281, 0.717 ± 0.257, P = 0.011, respectively; low values abnormal), non-dipolar components of T-wave and P-wave morphology (T_NonDipolarABS: 0.0496 ± 0.0377, 0.0571 ± 0.0487, 0.0432 ± 0.0476, 0.0380 ± 0.0377, P = 0.027; P_NonDipolarABS: 0.0132 ± 0.0164, 0.0130 ± 0.0135, 0.0092 ± 0.0117, 0.0069 ± 0.00472, P = 0.005, respectively, high values abnormal), T-wave morphology dispersion (TMD: 45.9 ± 28.3, 40.5 ± 25.8, 35.5 ± 24.9, 33.0 ± 24.6, P = 0.030, respectively, high values abnormal), and P-wave heterogeneity (PWH: 20.0 ± 9.44, 19.7 ± 8.87, 17.9 ± 9.78, 15.4 ± 4.60, P = 0.019, respectively, high values abnormal) differed significantly between the groups with different stages of left ventricular fibrosis. After adjustment with heart weight, T_NonDipolarABS [standardized ß (sß) = 0.131, P = 0.014], PWAd (sß = -0.161, P = 0.003), P_NonDipolarABS (sß = 0.174, P = 0.001), and PWH (sß = 0.128, P = 0.015) retained independent association, and TWAd (sß = -0.091, P = 0.074) and TMD (sß = 0.097, P = 0.063) tended to retain their association with the degree of myocardial fibrosis. CONCLUSION: Our findings suggest that abnormal values of T- and P-wave morphology are associated with arrhythmic substrate represented by ventricular fibrosis partly explaining the mechanism behind their prognostic significance.


Asunto(s)
Electrocardiografía , Fibrosis , Ventrículos Cardíacos , Humanos , Fibrilación Atrial , Muerte Súbita Cardíaca/etiología
4.
Europace ; 25(1): 164-174, 2023 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-35852923

RESUMEN

AIMS: To evaluate the prognostic significance of novel P-wave morphology descriptors in general population. METHODS AND RESULTS: Novel P-wave morphology variables were analyzed from orthogonal X-, Y-, Z-leads of the digitized electrocardiogram using a custom-made software in 6906 middle-aged subjects of the Mini-Finland Health Survey. A total of 3747 (54.3%) participants died during the follow-up period of 24.3 ± 10.4 years; 379 (5.5%) of the study population succumbed to sudden cardiac death (SCD), 928 (13.4%) to non-SCD (NSCD) and 2440 (35.3%) patients to non-cardiac death (NCD). In univariate comparisons, most of the studied P-wave morphology parameters had a significant association with all modes of death (P from <0.05 to <0.001). After relevant adjustments in the Cox multivariate hazards model, P-wave morphology dispersion (PMD) still tended to predict SCD [hazard ratio (HR): 1.006, 95% confidence interval (CI): 1.000-1.012, P = 0.05) but not NSCD (HR: 0.999, 95% CI: 0.995-1.003, P = 0.68) or NCD (HR: 0.999, 95% CI: 0.997-1.001, P = 0.44). The P-wave maximum amplitude in the lead Z (P-MaxAmp-Z) predicted SCD even after multivariate adjustments (HR: 1.010, 95% CI: 1.005-1.015, P = 0.0002) but also NSCD (HR: 1.005, 95% CI: 1.002-1.009, P = 0.0005) and NCD (HR: 1.002, 95% CI: 1.000-1.005, P = 0.03). CONCLUSION: Abnormalities of P-wave morphology are associated with the risk of all modes of death in general population. After relevant adjustments, PMD was still closely associated with the risk of SCD but not with NSCD or NCD. P-MaxAmp-Z predicted SCD even after adjustments, however, it also retained its association with NSCD and NCD.


Asunto(s)
Enfermedades no Transmisibles , Persona de Mediana Edad , Humanos , Medición de Riesgo , Factores de Riesgo , Pronóstico , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía/métodos
5.
Eur Heart J ; 43(47): 4923-4930, 2022 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-36172703

RESUMEN

AIMS: At least 50% of deaths due to coronary artery disease (CAD) are sudden cardiac deaths (SCDs), but the role of acute plaque complications on the incidence of sudden death in CAD is somewhat unclear. The present study aimed to investigate plaque histology and concomitant myocardial disease in sudden coronary death. METHODS AND RESULTS: The study population is derived from the Fingesture study, which has collected data from 5869 consecutive autopsy-verified SCD victims in Northern Finland (population ≈600 000) between 1998 and 2017. In this substudy, histological examination of culprit lesions was performed in 600 SCD victims whose death was due to CAD. Determination of the cause of death was based on the combination of medical records, police reports, and autopsy data. Plaque histology was classified as either (i) plaque rupture or erosion, (ii) intraplaque haemorrhage, or (iii) stable plaque. The mean age of the study subjects was 64.9 ± 11.2 years, and 82% were male. Twenty-four per cent had plaque rupture or plaque erosion, 24% had an intraplaque haemorrhage, and 52% had a stable plaque. Myocardial hypertrophy was present in 78% and myocardial fibrosis in 93% of victims. The presence of myocardial hypertrophy or fibrosis was not associated with specific plaque histology. CONCLUSION: Less than half of sudden deaths due to CAD had evidence of acute plaque complication, an observation which is contrary to historical perceptions. The prevalence of concomitant myocardial disease was high and independent of associated plaque morphology.


Asunto(s)
Cardiomiopatías , Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/patología , Placa Aterosclerótica/complicaciones , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/diagnóstico , Cardiomiopatías/complicaciones , Hemorragia/complicaciones , Hipertrofia/complicaciones , Factores de Riesgo
6.
Europace ; 24(12): 1942-1951, 2022 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-36037009

RESUMEN

AIMS: To evaluate the prognostic significance of the temporal variability of P-wave morphology, specifically in relation to cardiac autonomic regulation. METHODS AND RESULTS: We analyzed the standard deviation of P-wave residuum (PWRSD) from five consecutive beats of the standard 12-lead ECG in 1236 patients with angiographically verified coronary artery disease (CAD). We evaluated the prognostic value of PWRSD, of PWRSD and PWR in relation to the 24 h standard deviation of normal-to-normal intervals (PWRSD/SDNN and PWR/SDNN). After 8.7 ± 2.2 years of follow-up on average, 43 patients (3.5%) experienced sudden cardiac death (SCD) or were resuscitated from sudden cardiac arrest (SCA), 34 (2.8%) succumbed to non-sudden cardiac death (NSCD) and 113 (9.1%) to non-cardiac death (NCD). In the Cox regression analysis, PWRSD (≥0.002727) had a significant univariate (uv) [hazard ratio (HR): 4.27, 95% confidence interval (CI): 2.26-8.08, P = 0.000008] and multivariate (mv) (HR: 2.58, 95% CI: 1.31-5.08, P = 0.006) association with SCD/SCA but not with NSCD (uv P = 0.76, mv P = 0.33) or NCD (uv P = 0.57, mv P = 0.66). All the studied P-morphology parameters retained a significant association with the risk of SCD/SCA after relevant adjustment (mv P-values from 0.00003 to <0.05) but not with NSCD or NCD. When dichotomized PWRSD, PWR, PWRSD/SDNN, and PWR/SDNN were added to the clinical risk model for SCD/SCD, the C-index increased from 0.799 to 0.834 and integrated discrimination index and net reclassification index improved significantly (P < 0.001). CONCLUSION: Variability of P-morphology representing temporo-spatial heterogeneity of atrial depolarization, specifically when combined with cardiac autonomic regulation, independently predicts the risk of SCD in patients with CAD.


Asunto(s)
Fibrilación Atrial , Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Fibrilación Atrial/complicaciones , Medición de Riesgo , Factores de Riesgo , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Electrocardiografía/métodos
7.
Sci Rep ; 12(1): 6783, 2022 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-35474073

RESUMEN

Fragmented QRS (fQRS) is an electrocardiographic (ECG) marker of myocardial conduction abnormality, characterized by additional notches in the QRS complex. The presence of fQRS has been associated with an increased risk of all-cause mortality and arrhythmia in patients with cardiovascular disease. However, current binary visual analysis is prone to intra- and inter-observer variability and different definitions are problematic in clinical practice. Therefore, objective quantification of fQRS is needed and could further improve risk stratification of these patients. We present an automated method for fQRS detection and quantification. First, a novel robust QRS complex segmentation strategy is proposed, which combines multi-lead information and excludes abnormal heartbeats automatically. Afterwards extracted features, based on variational mode decomposition (VMD), phase-rectified signal averaging (PRSA) and the number of baseline-crossings of the ECG, were used to train a machine learning classifier (Support Vector Machine) to discriminate fragmented from non-fragmented ECG-traces using multi-center data and combining different fQRS criteria used in clinical settings. The best model was trained on the combination of two independent previously annotated datasets and, compared to these visual fQRS annotations, achieved Kappa scores of 0.68 and 0.44, respectively. We also show that the algorithm might be used in both regular sinus rhythm and irregular beats during atrial fibrillation. These results demonstrate that the proposed approach could be relevant for clinical practice by objectively assessing and quantifying fQRS. The study sets the path for further clinical application of the developed automated fQRS algorithm.


Asunto(s)
Fibrilación Atrial , Electrocardiografía , Algoritmos , Fibrilación Atrial/diagnóstico , Electrocardiografía/métodos , Humanos , Aprendizaje Automático , Máquina de Vectores de Soporte
8.
Heart Rhythm ; 19(8): 1297-1303, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35472593

RESUMEN

BACKGROUND: QRS duration and corrected QT (QTc) interval have been associated with sudden cardiac death (SCD), but no data are available on the significance of repolarization component (JTc interval) of the QTc interval as an independent risk marker in the general population. OBJECTIVE: In this study, we sought to quantify the risk of SCD associated with QRS, QTc, and JTc intervals. METHODS: This study was conducted using data from 3 population cohorts from different eras, comprising a total of 20,058 individuals. The follow-up period was limited to 10 years and age at baseline to 30-61 years. QRS duration and QT interval (Bazett's) were measured from standard 12-lead electrocardiograms at baseline. JTc interval was defined as QTc interval - QRS duration. Cox proportional hazards models that controlled for confounding clinical factors identified at baseline were used to estimate the relative risk of SCD. RESULTS: During a mean period of 9.7 years, 207 SCDs occurred (1.1 per 1000 person-years). QRS duration was associated with a significantly increased risk of SCD in each cohort (pooled hazard ratio [HR] 1.030 per 1-ms increase; 95% confidence interval [CI] 1.017-1.043). The QTc interval had borderline to significant associations with SCD and varied among cohorts (pooled HR 1.007; 95% CI 1.001-1.012). JTc interval as a continuous variable was not associated with SCD (pooled HR 1.001; 95% CI 0.996-1.007). CONCLUSION: Prolonged QRS durations and QTc intervals are associated with an increased risk of SCD. However, when the QTc interval is deconstructed into QRS and JTc intervals, the repolarization component (JTc) appears to have no independent prognostic value.


Asunto(s)
Muerte Súbita Cardíaca , Electrocardiografía , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Humanos , Pronóstico , Modelos de Riesgos Proporcionales , Factores de Riesgo
9.
Heart Rhythm ; 19(6): 952-959, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35181482

RESUMEN

BACKGROUND: Poor R-wave progression (PRWP) is a common clinical finding on the standard 12-lead electrocardiogram (ECG), but its prognostic significance is unclear. OBJECTIVE: The purpose of this study was to examine the prognosis associated with PRWP in terms of sudden cardiac death (SCD), cardiac death, and all-cause mortality in general population subjects with and without coronary artery disease (CAD). METHODS: Data and 12-lead ECGs were collected from a Finnish general population health examination survey conducted during 1978-1980 with follow-up until 2011. The study population consisted of 6854 subjects. Main end points were SCD, cardiac death, and all-cause mortality. PRWP was defined as R-wave amplitude ≤ 0.3 mV in lead V3 and R-wave amplitude in lead V2 ≤ R-wave amplitude in lead V3. RESULTS: PRWP occurred in 213 subjects (3.1%). During the follow-up period of 24.3 ± 10.4 years, 3723 subjects (54.3%) died. PRWP was associated with older age, higher prevalence of heart failure and CAD, and ß-blocker medication. In multivariate analyses, PRWP was associated with SCD (hazard ratio [HR] 2.13; 95% confidence interval [CI] 1.34-3.39), cardiac death (HR 1.75; 95% CI 1.35-2.15), and all-cause mortality (HR 1.29; 95% CI 1.08-1.54). In the subgroup with CAD, PRWP had a stronger association with cardiac mortality (HR 1.71; 95% CI 1.19-2.46) than in the subgroup without CAD, while the association with SCD was significant only in the subgroup with CAD (HR 2.62; 95% CI 1.38-4.98). CONCLUSION: PRWP was associated with adverse prognosis in the general population and with SCD in subjects with CAD.


Asunto(s)
Enfermedad de la Arteria Coronaria , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Electrocardiografía , Humanos , Pronóstico , Modelos de Riesgos Proporcionales , Factores de Riesgo
10.
Eur J Appl Physiol ; 122(1): 223-232, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34655331

RESUMEN

PURPOSE: Upper-body exercise performed in a cold environment may increase cardiovascular strain, which could be detrimental to patients with coronary artery disease (CAD). This study compared cardiovascular responses of CAD patients during graded upper-body dynamic and static exercise in cold and neutral environments. METHODS: 20 patients with stable CAD performed 30 min of progressive dynamic (light, moderate, and heavy rating of perceived exertion) and static (10, 15, 20, 25 and 30% of maximal voluntary contraction) upper body exercise in cold (- 15 °C) and neutral (+ 22 °C) environments. Heart rate (HR), blood pressure (BP) and electrocardiographic (ECG) responses were recorded and rate pressure product (RPP) calculated. RESULTS: Dynamic-graded upper-body exercise in the cold increased HR by 2.3-4.8% (p = 0.002-0.040), MAP by 3.9-5.9% (p = 0.038-0.454) and RPP by 18.1-24.4% (p = 0.002-0.020) when compared to the neutral environment. Static graded upper-body exercise in the cold resulted in higher MAP (6.3-9.1%; p = 0.000-0.014), lower HR (4.1-7.2%; p = 0.009-0.033), but unaltered RPP compared to a neutral environment. Heavy dynamic exercise resulted in ST depression that was not related to temperature. Otherwise, ECG was largely unaltered during exercise in either thermal condition. CONCLUSIONS: Dynamic- and static-graded upper-body exercise in the cold involves higher cardiovascular strain compared with a neutral environment among patients with stable CAD. However, no marked changes in electric cardiac function were observed. The results support the use of upper-body exercise in the cold in patients with stable CAD. TRIAL REGISTRATION: Clinical trial registration NCT02855905 August 2016.


Asunto(s)
Frío , Enfermedad de la Arteria Coronaria/fisiopatología , Ejercicio Físico/fisiología , Presión Sanguínea , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad
11.
Europace ; 24(5): 774-783, 2022 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-34849744

RESUMEN

AIM: The association of standard 12-lead electrocardiogram (ECG) markers with benefits of the primary prophylactic implantable cardioverter-defibrillator (ICD) has not been determined in the contemporary era. We analysed traditional and novel ECG variables in a large prospective, controlled primary prophylactic ICD population to assess the predictive value of ECG in terms of ICD benefit. METHODS AND RESULTS: Electrocardiograms from 1477 ICD patients and 700 control patients (EU-CERT-ICD; non-randomized, controlled, prospective multicentre study; ClinicalTrials.gov Identifier: NCT02064192), who met ICD implantation criteria but did not receive the device, were analysed. The primary outcome was all-cause mortality. In ICD patients, the co-primary outcome of first appropriate shock was used. Mean follow-up time was 2.4 ± 1.1 years to death and 2.3 ± 1.2 years to the first appropriate shock. Pathological Q waves were associated with decreased mortality in ICD patients [hazard ratio (HR) 0.54, 95% confidence interval (CI) 0.35-0.84; P < 0.01] and patients with pathological Q waves had significantly more benefit from ICD (HR 0.44, 95% CI 0.21-0.93; P = 0.03). QTc interval increase taken as a continuous variable was associated with both mortality and appropriate shock incidence, but commonly used cut-off values, were not statistically significantly associated with either of the outcomes. CONCLUSION: Pathological Q waves were a strong ECG predictor of ICD benefit in primary prophylactic ICD patients. Excess mortality among Q wave patients seems to be due to arrhythmic death which can be prevented by ICD.


Asunto(s)
Desfibriladores Implantables , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Electrocardiografía , Humanos , Prevención Primaria/métodos , Estudios Prospectivos , Factores de Riesgo
12.
J Electrocardiol ; 69: 105-110, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34656915

RESUMEN

BACKGROUND: Negative T-waves are associated with sudden cardiac death (SCD) risk in the general population. Whether flat T-waves also predict SCD is not known. The aim of the study was to examine the clinical characteristics and risk of SCD in general population subjects with flat T-waves. METHODS: We examined the electrocardiograms of 6750 Finnish general population adults aged ≥30 years and classified the subjects into 3 groups: 1) negative T-waves with an amplitude ≥0.1 mV in ≥2 of the leads I, II, aVL, V4-V6, 2) negative or positive low amplitude T-waves with an amplitude <0.1 mV and the ratio of T-wave and R-wave <10% in ≥2 of the leads I, II, aVL, V4-V6, and 3) normal positive T-waves (not meeting the aforesaid criteria). The association between T-wave classification and SCD was assessed during a 10-year follow-up. RESULTS: A total of 215 (3.2%) subjects had negative T-waves, 856 (12.7%) flat T-waves, and 5679 (84.1%) normal T-waves. Flat T-wave subjects were older and had more often cardiovascular morbidities compared to normal T-wave subjects, while negative T-wave subjects were the oldest and had most often cardiovascular morbidities. After adjusting for multiple factors, both flat T-waves (hazard ratio [HR] 1.81; 95% confidence interval [CI] 1.13-2.91) and negative T-waves (HR 3.27; 95% CI 1.85-5.78) associated with SCD. CONCLUSIONS: Cardiovascular risk factors and disease are common among subjects with flat T-waves, but these minor T-wave abnormalities are also independently associated with increased SCD risk.


Asunto(s)
Arritmias Cardíacas , Electrocardiografía , Adulto , Muerte Súbita Cardíaca/epidemiología , Humanos , Pronóstico , Modelos de Riesgos Proporcionales , Medición de Riesgo , Factores de Riesgo
13.
Ann Noninvasive Electrocardiol ; 26(3): e12830, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33486851

RESUMEN

BACKGROUND: The possible relationship between temporal variability of electrocardiographic spatial heterogeneity of repolarization and the risk of sudden cardiac death (SCD) in patients with coronary artery disease (CAD) is not completely understood. METHODS: The standard deviation of T-wave morphology dispersion (TMD-SD), of QRST angle (QRSTA-SD), and of T-wave area dispersion (TW-Ad-SD) were analyzed on beat-to-beat basis from 10 min period of the baseline electrocardiographic recording in ARTEMIS study patients with angiographically verified CAD. RESULTS: After on average of 8.6 ± 2.3 years of follow-up, a total of 66 of the 1,678 present study subjects (3.9%) had experienced SCD or were resuscitated from sudden cardiac arrest (SCA). TMD-SD was most closely associated with the risk for SCD and was significantly higher in patients who had experienced SCD/SCA compared with those who remained alive (3.61 ± 2.83 vs. 2.64 ± 2.52, p = .008, respectively), but did not differ significantly between the patients who had experienced non-SCD (n = 71, 4.2%) and those who remained alive (3.20 ± 2.73 vs. 2.65 ± 2.53, p = .077, respectively) or between the patients who succumbed to non-cardiac death (n = 164, 9.8%) and those who stayed alive (2.64 ± 2.17 vs. 2.68 ± 2.58, p = .853). After adjustments with relevant clinical risk indicators of SCD/SCA, TMD-SD still predicted SCD/SCA (HR 1.107, 95% CIs 1.035-1.185, p = .003). CONCLUSIONS: Temporal variability of electrocardiographic spatial heterogeneity of repolarization represented by TMD-SD independently predicts long-term risk of SCD/SCA in patients with CAD.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/epidemiología , Muerte Súbita Cardíaca/epidemiología , Electrocardiografía/métodos , Anciano , Causalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Medición de Riesgo , Factores de Tiempo
14.
Front Physiol ; 11: 1045, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32982784

RESUMEN

INTRODUCTION: The prognostic significance of beat-to-beat variability of spatial heterogeneity of repolarization measured from standard 12-lead ECG is not well-understood. METHODS: We measured the short-term variability of repolarization parameters, such as T-wave heterogeneity in leads V4-V6 (TWH) and QT interval (QT), from five consecutive beats of previously recorded standard 12-lead ECG in 200 victims of unexpected sudden cardiac death (SCD) confirmed to be due to complicated atherosclerotic coronary artery disease (CAD) in medico-legal autopsy and 200 age- and sex-matched controls with angiographically confirmed CAD. The short-term variability of repolarization heterogeneity was defined as the standard deviation (SD) of the measured repolarization parameters. All ECGs were in sinus rhythm, and no premature ventricular contractions were included in the measured segment. RESULTS: TWH-SD and QT-SD were significantly higher in SCD victims than in subjects with CAD (6.9 ± 5.6 µV vs. 3.8 ± 2.6 µV, p = 1.8E-11; 8.3 ± 13.1 ms vs. 3.8 ± 7.1 ms, p = 0.00003, respectively). After adjusting in the multivariate clinical model with factors, such as diabetes, RR interval, and beta blocker medication, TWH-SD and QT-SD retained their significant power in discriminating between the victims of SCD and the patients with CAD (p = 0.00003, p = 0.006, respectively). TWH-SD outperformed QT-SD in identifying the SCD victims among the study subjects (area under the curve in the receiver operating characteristics curve 0.730 vs. 0.679, respectively). CONCLUSION: Increased short-term variability of repolarization heterogeneity measured from standard 12-lead ECG is associated with SCD.

15.
Am J Cardiol ; 130: 70-77, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32684284

RESUMEN

Heart failure (HF) is one of the leading causes of hospitalization in the Western world. Women have a lower HF hospitalization rate and mortality compared with men. The role of electrocardiography as a risk marker of future HF in women is not well known. We studied association of electrocardiographic (ECG) risk factors for HF hospitalization in women from a large middle-aged general population with a long-term follow-up and compared the risk profile to men. Standard 12-lead ECG markers were analyzed from 10,864 subjects (49% women), and their predictive value for HF hospitalization was analyzed. During the follow-up (30 ± 11 years), a total of 1,743 subjects had HF hospitalization; of these, 861 were women (49%). Several baseline characteristics, such as age, body mass index, blood pressure, and history of previous cardiac disease predicted the occurrence of HF both in women and men (p <0.001 for all). After adjusting for baseline variables, ECG sign of left ventricular hypertrophy (LVH) (p <0.001), and atrial fibrillation (p <0.001) were the only baseline ECG variables that predicted future HF in women. In men, HF was predicted by fast heart rate (p = 0.008), T wave inversions (p <0.001), abnormal Q-waves (p = 0.002), and atrial fibrillation (p <0.001). Statistically significant gender interactions in prediction of HF were observed in ECG sign of LVH, inferolateral T wave inversions, and heart rate. In conclusion, ECG sign of LVH predicts future HF in middle-aged women, and T wave inversions and elevated heart rate are associated with HF hospitalization in men.


Asunto(s)
Electrocardiografía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Hospitalización/estadística & datos numéricos , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Medición de Riesgo , Factores de Riesgo , Distribución por Sexo
16.
Europace ; 22(8): 1173-1181, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32556298

RESUMEN

AIMS: Identifying subjects at high and low risk of atrial fibrillation (AF) is of interest. This study aims to assess the risk of AF associated with electrocardiographic (ECG) markers linked to atrial fibrosis: P-wave prolongation, 3rd-degree interatrial block, P-terminal force in lead V1, and orthogonal P-wave morphology. METHODS AND RESULTS: P-wave parameters were assessed in a representative Finnish population sample aged ≥30 years (n = 7217, 46.0% male, mean age 51.4 years). Subjects (n = 5489) with a readable ECG including the orthogonal leads, sinus rhythm, and a predefined orthogonal P-wave morphology type [positive in leads X and Y and either negative (Type 1) or ± biphasic (Type 2) in lead Z; Type 3 defined as positive in lead X and ± biphasic in lead Y], were followed 10 years from the baseline examinations (performed 1978-80). Subjects discharged with AF diagnosis after any-cause hospitalization (n = 124) were defined as having developed AF. Third-degree interatrial block was defined as P-wave ≥120 ms and the presence of ≥2 ± biphasic P waves in the inferior leads. Hazard ratios (HRs) and confidence intervals (CIs) were assessed with Cox models. Third-degree interatrial block (n = 103, HR 3.18, 95% CI 1.66-6.13; P = 0.001) and Type 3 morphology (n = 216, HR 3.01, 95% CI 1.66-5.45; P < 0.001) were independently associated with the risk of hospitalization with AF. Subjects with P-wave <110 ms and Type 1 morphology (n = 2074) were at low risk (HR 0.46, 95% CI 0.26-0.83; P = 0.006), compared to the rest of the subjects. CONCLUSION: P-wave parameters associate with the risk of hospitalization with AF.


Asunto(s)
Fibrilación Atrial , Alta del Paciente , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Electrocardiografía , Femenino , Finlandia/epidemiología , Hospitales , Humanos , Bloqueo Interauricular , Masculino , Persona de Mediana Edad
17.
J Electrocardiol ; 61: 1-9, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32460128

RESUMEN

BACKGROUND: Fragmented QRS (fQRS) on 12-lead electrocardiogram (ECG) is associated with scarred myocardium and adverse outcome. However, the data on gender differences in terms of its prevalence and prognostic value is sparse. The aim of this study was to evaluate whether gender differences in fQRS exist among subjects drawn from populations with different risk profiles. METHODS: We analyzed fQRS from 12-lead ECG in 953 autopsy-confirmed victims of sudden cardiac death (SCD) (78% men; 67.0 ± 11.4 yrs), 1900 coronary artery disease (CAD) patients with angiographically confirmed stenosis of ≥50% (70% men; 66.6 ± 9.0 yrs, 43% with previous myocardial infarction [MI]), and in 10,904 adults drawn from the Finnish adult general population (52% men; 44.0 ± 8.5 yrs). RESULTS: Prevalence of fQRS was associated with older age, male sex and the history and severity of prior cardiac disease of subjects. Among the general population fQRS was more commonly found among men in comparison to women (20.5% vs. 14.8%, p < 0.001). The prevalence of fQRS rose gradually along with the severity of prior cardiac disease in both genders, yet remained significantly higher in the male population: subjects with suspected or known cardiac disease (25.4% vs. 15.8% p < 0.001), CAD patients without prior MI (39.9% vs. 26.4%, p < 0.001), CAD patients with prior MI (42.9% vs. 31.2%, p < 0.001), and victims of SCD (56.4% vs. 44.4%, p < 0.001). CONCLUSIONS: The prevalence of QRS fragmentation varies in different populations. The fragmentation is clearly related to the underlying cardiac disease in both genders, however women seem to have significantly lower prevalence of fQRS in each patient population in comparison to men.


Asunto(s)
Electrocardiografía , Caracteres Sexuales , Adulto , Anciano , Femenino , Finlandia , Humanos , Masculino , Valor Predictivo de las Pruebas , Prevalencia , Pronóstico
18.
Eur Heart J ; 41(21): 1988-1999, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32259257

RESUMEN

AIMS: To determine whether the combination of standard electrocardiographic (ECG) markers reflecting domains of arrhythmic risk improves sudden and/or arrhythmic death (SAD) risk stratification in patients with coronary heart disease (CHD). METHODS AND RESULTS: The association between ECG markers and SAD was examined in a derivation cohort (PREDETERMINE; N = 5462) with adjustment for clinical risk factors, left ventricular ejection fraction (LVEF), and competing risk. Competing outcome models assessed the differential association of ECG markers with SAD and competing mortality. The predictive value of a derived ECG score was then validated (ARTEMIS; N = 1900). In the derivation cohort, the 5-year cumulative incidence of SAD was 1.5% [95% confidence interval (CI) 1.1-1.9] and 6.2% (95% CI 4.5-8.3) in those with a low- and high-risk ECG score, respectively (P for Δ < 0.001). A high-risk ECG score was more strongly associated with SAD than non-SAD mortality (adjusted hazard ratios = 2.87 vs. 1.38 respectively; P for Δ = 0.003) and the proportion of deaths due to SAD was greater in the high vs. low risk groups (24.9% vs. 16.5%, P for Δ = 0.03). Similar findings were observed in the validation cohort. The addition of ECG markers to a clinical risk factor model inclusive of LVEF improved indices of discrimination and reclassification in both derivation and validation cohorts, including correct reclassification of 28% of patients in the validation cohort [net reclassification improvement 28 (7-49%), P = 0.009]. CONCLUSION: For patients with CHD, an externally validated ECG score enriched for both absolute and proportional SAD risk and significantly improved risk stratification compared to standard clinical risk factors including LVEF. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT01114269. ClinicalTrials.gov ID NCT01114269.


Asunto(s)
Enfermedad Coronaria , Función Ventricular Izquierda , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Electrocardiografía , Humanos , Valor Predictivo de las Pruebas , Pronóstico , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico
19.
Physiol Meas ; 41(4): 04NT01, 2020 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-32217820

RESUMEN

OBJECTIVE: To validate the accuracy of the Oura ring in the quantification of resting heart rate (HR) and heart rate variability (HRV). BACKGROUND: Wearable devices have become comfortable, lightweight, and technologically advanced for assessing health behavior. As an example, the novel Oura ring integrates daily physical activity and nocturnal cardiovascular measurements. Ring users can follow their autonomic nervous system responses to their daily behavior based on nightly changes in HR and HRV, and adjust their behavior accordingly after self-reflection. As wearable photoplethysmogram (PPG) can be disrupted by several confounding influences, it is crucial to demonstrate the accuracy of ring measurements. APPROACH: Nocturnal HR and HRV were assessed in 49 adults with simultaneous measurements from the Oura ring and the gold standard ECG measurement. Female and male participants with a wide age range (15-72 years) and physical activity status were included. Regression analysis between ECG and the ring outcomes was performed. MAIN RESULTS: Very high agreement between the ring and ECG was observed for nightly average HR and HRV (r2 = 0.996 and 0.980, respectively) with a mean bias of -0.63 bpm and -1.2 ms. High agreement was also observed across 5 min segments within individual nights in (r2 = 0.869 ± 0.098 and 0.765 ± 0.178 in HR and HRV, respectively). SIGNIFICANCE: Present findings indicate high validity of the Oura ring in the assessment of nocturnal HR and HRV in healthy adults. The results show the utility of this miniaturised device as a lifestyle management tool in long-term settings. High quality PPG signal results prompt future studies utilizing ring PPG towards clinically relevant health outcomes.


Asunto(s)
Electrocardiografía , Frecuencia Cardíaca , Fotopletismografía/instrumentación , Adolescente , Adulto , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Recuperación de la Función , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Adulto Joven
20.
PLoS One ; 15(3): e0230655, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32208439

RESUMEN

BACKGROUND: T-wave area dispersion (TW-Ad) is a novel electrocardiographic (ECG) repolarization marker associated with sudden cardiac death. However, limited data is available on the clinical correlates of TW-Ad. In addition, there are no previous studies on cardiovascular drug effects on TW-Ad. In this study, we examined the relation between TW-Ad and left ventricular mass. We also studied the effects of four commonly used antihypertensive drugs on TW-Ad. METHODS: A total of 242 moderately hypertensive males (age, 51±6 years; office systolic/diastolic blood pressure during placebo, 153±14/100±8 mmHg), participating in the GENRES study, were included. Left ventricular mass index was determined by transthoracic echocardiography. Antihypertensive four-week monotherapies (a diuretic, a beta-blocker, a calcium channel blocker, and an angiotensin receptor antagonist) were administered in a randomized rotational fashion. Four-week placebo periods preceded all monotherapies. The average value of measurements (over 1700 ECGs in total) from all available placebo periods served as a reference to which measurements during each drug period were compared. RESULTS: Lower, i.e. risk-associated TW-Ad values correlated with a higher left ventricular mass index (r = -0.14, p = 0.03). Bisoprolol, a beta-blocker, elicited a positive change in TW-Ad (p = 1.9×10-5), but the three other drugs had no significant effect on TW-Ad. CONCLUSIONS: Our results show that TW-Ad is correlated with left ventricular mass and can be modified favorably by the use of bisoprolol, although demonstration of any effects on clinical endpoints requires long-term prospective studies. Altogether, our results suggest that TW-Ad is an ECG repolarization measure of left ventricular arrhythmogenic substrate.


Asunto(s)
Antihipertensivos/uso terapéutico , Ventrículos Cardíacos/fisiopatología , Hipertensión/tratamiento farmacológico , Antagonistas Adrenérgicos beta/farmacología , Antagonistas Adrenérgicos beta/uso terapéutico , Antagonistas de Receptores de Angiotensina/farmacología , Antagonistas de Receptores de Angiotensina/uso terapéutico , Antihipertensivos/farmacología , Bisoprolol/farmacología , Bisoprolol/uso terapéutico , Presión Sanguínea , Bloqueadores de los Canales de Calcio/farmacología , Bloqueadores de los Canales de Calcio/uso terapéutico , Muerte Súbita Cardíaca/prevención & control , Diuréticos/farmacología , Diuréticos/uso terapéutico , Método Doble Ciego , Ecocardiografía , Ventrículos Cardíacos/anatomía & histología , Ventrículos Cardíacos/efectos de los fármacos , Humanos , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Función Ventricular/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA