Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Pediatr ; 275: 114222, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39097264

RESUMEN

OBJECTIVE: To identify delivery room (DR) characteristics of patients with transposition of the great arteries (TGA) who underwent preoperative balloon atrial septostomy (BAS). STUDY DESIGN: Retrospective cohort study of all patients with prenatally diagnosed TGA delivered at our center between 2013 and 2023 who underwent arterial switch operation during the newborn admission. RESULTS: A total of 168 patients were included (median gestational age 39.5 weeks, 64% male, 33% with ventricular septal defect, 8% with aortic arch hypoplasia). BAS was performed in 84 patients (50%). Patients who underwent BAS had higher proportion of intubation in the DR (87% vs 33%, P < .001), lower maximum oxygen saturation in the first 10 minutes (64% vs 74%, P < .001) and 20 minutes (71% vs 81%, P < .001) of life, and lower maximum oxygen saturation at any point in the DR (79% vs 87%, P < .001). Adjusting for confounders (ventricular septal defect, aortic arch anomaly, 5-minute Apgar, birth weight), intubation in the DR (aOR 9.5, 95% CI 3.9, 25.0) and lower maximum oxygen saturation in the DR (aOR 0.9, 95% CI 0.8, 0.9) were independently associated with BAS. By receiver operating characteristic analysis, a maximum oxygen saturation of less than 86% at any time point in the DR discriminated for BAS with a specificity of 0.88, sensitivity of 0.70, and area under the curve of 0.82. CONCLUSIONS: Intubation and lower oxygen saturation in the DR are independently associated with BAS in patients with TGA born at our center. A maximum DR saturation of less than 86% best discriminates patients who undergo BAS in our population.

2.
World J Pediatr Congenit Heart Surg ; 15(2): 209-214, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38321748

RESUMEN

Although current studies do not support the routine use of corticosteroids after cardiopulmonary bypass in pediatric patients, there is incomplete understanding of the potential hemodynamic contribution of postoperative critical illness-related corticosteroid insufficiency in the intensive care unit. By reviewing the available studies and underlying pathophysiology of these phenomena in critically ill neonates, we can identify a subset of patients that may benefit from optimal diagnosis and treatment of receiving postoperative steroids. A suggested algorithm used at our institution is provided as a guideline for treatment of this high-risk population.


Asunto(s)
Insuficiencia Suprarrenal , Procedimientos Quirúrgicos Cardíacos , Recién Nacido , Humanos , Niño , Enfermedad Crítica , Insuficiencia Suprarrenal/diagnóstico , Insuficiencia Suprarrenal/epidemiología , Corticoesteroides , Unidades de Cuidados Intensivos
3.
Pediatr Crit Care Med ; 23(5): e257-e266, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35250003

RESUMEN

OBJECTIVES: Umbilical venous cannulation is the favored approach to perinatal central access worldwide but has a failure rate of 25-50% and the insertion technique has not evolved in decades. Improving the success of this procedure would have broad implications, particularly where peripherally inserted central catheters are not easily obtained and in neonates with congenital heart disease, in whom umbilical access facilitates administration of inotropes and blood products while sparing vessels essential for later cardiac interventions. We sought to use real-time, point-of-care ultrasound to achieve central umbilical venous access in patients for whom conventional, blind placement techniques had failed. DESIGN: Multicenter case series, March 2019-May 2021. SETTING: Cardiac and neonatal ICUs at three tertiary care children's hospitals. PATIENTS: We identified 32 neonates with congenital heart disease, who had failed umbilical venous cannulation using traditional, blind techniques. INTERVENTIONS: Real-time ultrasound guidance and liver pressure were used to replace malpositioned catheters and achieve successful placement at the inferior cavoatrial junction. MEASUREMENTS AND MAIN RESULTS: In 32 patients with failed prior umbilical venous catheter placement, real-time ultrasound guidance was used to successfully "rescue" the line and achieve central position in 23 (72%). Twenty of 25 attempts (80%) performed in the first 48 hours of life were successful, and three of seven attempts (43%) performed later. Twenty-four patients (75%) were on prostaglandin infusion at the time of the procedure. We did not identify an association between patient weight or gestational age and successful placement. CONCLUSIONS: Ultrasound guidance has become standard of care for percutaneous central venous access but is a new and emerging technique for umbilical vessel catheterization. In this early experience, we report that point-of-care ultrasound, together with liver pressure, can be used to markedly improve success of placement. This represents a significant advance in this core neonatal procedure.


Asunto(s)
Cateterismo Venoso Central , Cateterismo Periférico , Catéteres Venosos Centrales , Cardiopatías Congénitas , Cateterismo Venoso Central/métodos , Cateterismo Periférico/métodos , Catéteres , Niño , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/terapia , Humanos , Recién Nacido , Ultrasonografía , Ultrasonografía Intervencional/métodos
4.
J Vasc Access ; 23(4): 624-627, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33706604

RESUMEN

Central venous access, a common and essential component of the care of the critically ill neonate, is associated with complications such as infection, thrombosis, and bleeding. Unintentional arterial cannulation of a venous catheter is a rare but potentially dangerous complication. In the report, we describe the accidental cannulation of an artery with an epicutaneo-caval catheter in an extremely low birth weight infant. We discuss the physical and radiological findings that raise the suspicion of an arterial placement of a catheter, the diagnostic tools to confirm the misplacement, the potential complications, and strategies to prevent it.


Asunto(s)
Cateterismo Venoso Central , Catéteres Venosos Centrales , Trombosis , Cateterismo Venoso Central/efectos adversos , Catéteres de Permanencia , Enfermedad Crítica , Humanos , Lactante , Recién Nacido , Trombosis/prevención & control
5.
Cancer Res ; 73(7): 2117-26, 2013 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-23378345

RESUMEN

Chronic inflammation is a major risk factor for cancer, including gastric cancers and other gastrointestinal cancers. For example, chronic inflammation caused by autoimmune gastritis (AIG) is associated with an increased risk of gastric polyps, gastric carcinoid tumors, and possibly adenocarcinomas. In this study, we characterized the progression of gastric cancer in a novel mouse model of AIG. In this model, disease was caused by CD4(+) T cells expressing a transgenic T-cell receptor specific for a peptide from the H(+)/K(+) ATPase proton pump, a protein expressed by parietal cells in the stomach. AIG caused epithelial cell aberrations that mimicked most of those seen in progression of human gastric cancers, including chronic gastritis followed by oxyntic atrophy, mucous neck cell hyperplasia, spasmolytic polypeptide-expressing metaplasia, dysplasia, and ultimately gastric intraepithelial neoplasias. Our work provides the first direct evidence that AIG supports the development of gastric neoplasia and provides a useful model to study how inflammation drives gastric cancer.


Asunto(s)
Enfermedades Autoinmunes/etiología , Linfocitos T CD4-Positivos/inmunología , Gastritis/complicaciones , ATPasa Intercambiadora de Hidrógeno-Potásio/inmunología , Inflamación/complicaciones , Receptores de Antígenos de Linfocitos T/fisiología , Neoplasias Gástricas/etiología , Adenocarcinoma/etiología , Adenocarcinoma/metabolismo , Adenocarcinoma/patología , Animales , Enfermedades Autoinmunes/metabolismo , Enfermedades Autoinmunes/patología , Western Blotting , Linfocitos T CD4-Positivos/metabolismo , Linfocitos T CD4-Positivos/patología , Citometría de Flujo , Técnica del Anticuerpo Fluorescente , Mucosa Gástrica/inmunología , Mucosa Gástrica/metabolismo , Mucosa Gástrica/patología , Gastritis/inmunología , Gastritis/patología , Humanos , Técnicas para Inmunoenzimas , Inflamación/inmunología , Inflamación/patología , Interferón gamma/metabolismo , Ganglios Linfáticos/inmunología , Ganglios Linfáticos/metabolismo , Ganglios Linfáticos/patología , Metaplasia/complicaciones , Metaplasia/inmunología , Metaplasia/patología , Ratones , Ratones Endogámicos BALB C , Ratones Transgénicos , ARN Mensajero/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Neoplasias Gástricas/metabolismo , Neoplasias Gástricas/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...