RESUMEN
PURPOSE: Imaging glioma biology holds great promise to unravel the complex nature of these tumors. Besides well-established imaging techniques such O-(2-[18F]fluoroethyl)-L-tyrosine (FET)-PET and dynamic susceptibility contrast (DSC) perfusion imaging, amide proton transfer-weighted (APTw) imaging has emerged as a promising novel MR technique. In this study, we aimed to better understand the relation between these imaging biomarkers and how well they capture cellularity and vascularity in newly diagnosed gliomas. METHODS: Preoperative MRI and FET-PET data of 46 patients (31 glioblastoma and 15 lower-grade glioma) were segmented into contrast-enhancing and FLAIR-hyperintense areas. Using established cutoffs, we calculated hot-spot volumes (HSV) and their spatial overlap. We further investigated APTw and CBV values in FET-HSV. In a subset of 10 glioblastoma patients, we compared cellularity and vascularization in 34 stereotactically targeted biopsies with imaging. RESULTS: In glioblastomas, the largest HSV was found for APTw, followed by PET and CBV (p < 0.05). In lower-grade gliomas, APTw-HSV was clearly lower than in glioblastomas. The spatial overlap of HSV was highest between APTw and FET in both tumor entities and regions. APTw correlated significantly with cellularity, similar to FET, while the association with vascularity was more pronounced in CBV and FET. CONCLUSIONS: We found a relevant spatial overlap in glioblastomas between hotspots of APTw and FET both in contrast-enhancing and FLAIR-hyperintense tumor. As suggested by earlier studies, APTw was lower in lower-grade gliomas compared with glioblastomas. APTw meaningfully contributes to biological imaging of gliomas.
Asunto(s)
Neoplasias Encefálicas , Glioma , Amidas , Aminoácidos , Biología , Neoplasias Encefálicas/diagnóstico por imagen , Glioma/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Perfusión , Tomografía de Emisión de Positrones , Protones , TirosinaRESUMEN
BACKGROUND AND PURPOSE: Glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging allows the direct measurement and mapping of glycosaminoglycans. In this study, we aimed to evaluate the usefulness of gagCEST imaging in the quantitative assessment of intervertebral disc degeneration in a comparison with Pfirrmann grade and T1-ρ measurements. MATERIALS AND METHODS: Ninety-six lumbar intervertebral discs in 24 volunteers (36.0 ± 8.5 years of age, 21 men and 3 women) were examined with both gagCEST imaging and T1-ρ measurements. The gagCEST imaging was performed at 3T with a saturation pulse with 1.0-second duration and the B1 amplitude of 0.8 µT followed by imaging by a 2D fast spin-echo sequence. The Z-spectra were obtained at 25 frequency offsets from -3 to +3 ppm (step, 0.25 ppm). A point-by-point B0 correction was performed with a B0 map. The gagCEST signal and T1-ρ values were measured in the nucleus pulposus in each intervertebral disc. The Pfirrmann grades were assessed on T2-weighted images. RESULTS: The gagCEST signal at grade I (5.36% ± 2.79%) was significantly higher than those at Pfirrmann grade II (3.15% ± 1.40%, P = .0006), grade III (0.14% ± 1.03%, P < .0001), grade IV (-1.75% ± 2.82%, P < .0001), and grade V (-1.47% ± 0.36%, P < .0001). The gagCEST signal at grade II was significantly higher than those of grade III (P < .0001), grade IV (P < .0001), and grade V (P < .0001). The gagCEST signal was significantly correlated negatively with Pfirrmann grade (P < .0001) and positively correlated with T1-ρ (P < .0001). CONCLUSIONS: GagCEST imaging could be a reliable and quantitative technique for assessing intervertebral disc degeneration.
Asunto(s)
Glicosaminoglicanos/análisis , Procesamiento de Imagen Asistido por Computador/métodos , Degeneración del Disco Intervertebral/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adulto , Correlación de Datos , Femenino , Humanos , Vértebras Lumbares , Masculino , Persona de Mediana EdadRESUMEN
A method is presented which allows precise temperature and longitudinal (T(1)) relaxation time measurements with high spatial and temporal resolution. This is achieved by combining dynamic variable flip angle based T(1) relaxation mapping with proton resonance frequency shift based thermometry. Herein, dynamic T(1) mapping is either used as a complementary measure of temperature or for the detection of T(1) contrast agent release. For the first application, the temperature evolution during a high-intensity focused ultrasound tissue ablation experiment was measured in both, porcine fat and muscle, simultaneously. In this application, temperature accuracies of 2.5 K for T(1)-based thermometry in fat and 1.2 K for proton resonance frequency shift-based thermometry in muscle were observed. The second application relates to MR-guidance of high-intensity focused ultrasound-induced local drug delivery by means of thermo-sensitive liposomes labeled with a T(1) contrast agent (Gd-HPDO3A). When the measured temperature exceeded the phase transition temperature of the liposomes, T(1) was observed to decrease with a good temporal and spatial correlation due to the release of Gd-HPDO3A. The presented results demonstrate the feasibility of the proposed method for two important applications in MR-guided noninvasive therapy. It offers a high temporal resolution when compared with interleaved Look-Locker based T(1) mapping techniques and thus represents an interesting candidate for simultaneous real-time monitoring of T(1) and temperature changes.