Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Bioanalysis ; 15(18): 1115-1128, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37681562

RESUMEN

Background: Volumetric absorptive microsampling has emerged as a less invasive alternative to venous sampling for small-molecule pharmacokinetic studies, but its application to novel therapeutics such as antisense oligonucleotides (ASOs) is not well-established. Results: A workflow was developed using Mitra microsampling coupled with hybridization LC-MS/MS for accurate determination of fomivirsen, a 21-mer ASO, in human blood. Quantitative recovery was achieved regardless of blood hematocrit level or microsample age by implementing impact-assisted extraction. A thorough method evaluation confirmed sensitivity, linearity, precision/accuracy, matrix effect, metabolite interference and four months of microsample stability. Conclusion: The combined impact-assisted extraction and hybridization LC-MS/MS workflow demonstrated the successful quantitation of fomivirsen, establishing the validity and applicability of the approach for ASO drug candidates.


Asunto(s)
Oligonucleótidos Antisentido , Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida , Hibridación de Ácido Nucleico
2.
Bioanalysis ; 14(12): 849-848, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35735179

RESUMEN

Anahita Keyhani speaks to Sankeetha Nadarajah, Commissioning Editor.


Asunto(s)
Diversidad Cultural , Industrias
3.
Bioanalysis ; 13(8): 609-619, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33847160

RESUMEN

The 13th Global CRO Council (GCC) closed forum for bioanalysis was held in New Orleans, LA, USA on 5 April 2019. This GCC meeting was organized to discuss the contents of the 2019 ICH M10 Bioanalytical Method Validation Draft Guideline published in February 2019 and consolidate the feedback of the GCC members. While ICH M10 will cover requirements for reference standards, one of the biggest challenges facing the CRO community is the lack of consistency and completeness of Certificates of Analysis for reference standards used in regulated bioanalysis. Similar challenges exist with critical reagents (e.g., capture and detection antibodies) used for assays supporting biologics. The recommendations provided in this publication are the minimum requirements for the content that GCC members believe should be included in Certificates of Analysis for reference standards obtained from commercial vendors, sponsors and compendial suppliers, for use in regulated bioanalytical studies. In addition, recommendations for internal standards, metabolites and critical reagents are discussed.


Asunto(s)
Anticuerpos/análisis , Bioensayo/normas , Humanos , Estándares de Referencia
4.
Biomark Med ; 13(14): 1209-1225, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31379197

RESUMEN

Aim: Detection of drug-induced dystrophin in patient muscle biopsy is a surrogate outcome measure for Duchenne muscular dystrophy. We sought to establish and validate an orthogonal approach to measurement of dystrophin protein and RNA in muscle biopsies. Materials & methods: Validated methods were developed for dystrophin western blotting, mass spectrometry, immunostaining and reverse transcriptase PCR of biopsy mRNA using muscle biopsy standards. Results: Both western blotting and mass spectrometry validated methods demonstrated good linearity, and acceptable precision and accuracy with a lower limit of quantitation at 1%. Immunostaining and reverse transcriptase PCR methods were shown to be reliable. Conclusion: The described orthogonal approach is sufficient to support measures of dystrophin as a surrogate outcome in a clinical trial.


Asunto(s)
Descubrimiento de Drogas , Distrofina/análisis , Biopsia , Western Blotting , Exones/genética , Humanos , Espectrometría de Masas , ARN Mensajero/análisis
5.
Bioanalysis ; 11(12): 1129-1138, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31319683

RESUMEN

The 12th GCC Closed Forum was held in Philadelphia, PA, USA, on 9 April 2018. Representatives from international bioanalytical Contract Research Organizations were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The issues discussed at the meeting included: critical reagents; oligonucleotides; certificates of analysis; method transfer; high resolution mass spectrometry; flow cytometry; recent regulatory findings and case studies involving stability and nonclinical immunogenicity. Conclusions and consensus from discussions of these topics are included in this article.


Asunto(s)
Certificación , Técnicas de Química Analítica , Citometría de Flujo , Espectrometría de Masas , Oligonucleótidos/análisis , Control Social Formal , Sociedades Científicas , Indicadores y Reactivos/química
6.
Bioanalysis ; 11(7): 645-653, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30993999

RESUMEN

Over the last decade, the use of biomarker data has become integral to drug development. Biomarkers are not only utilized for internal decision-making by sponsors; they are increasingly utilized to make critical decisions for drug safety and efficacy. As the regulatory agencies are routinely making decisions based on biomarker data, there has been significant scrutiny on the validation of biomarker methods. Contract research organizations regularly use commercially available immunoassay kits to validate biomarker methods. However, adaptation of such kits in a regulated environment presents significant challenges and was one of the key topics discussed during the 12th Global Contract Research Organization Council for Bioanalysis (GCC) meeting. This White Paper reports the GCC members' opinion on the challenges facing the industry and the GCC recommendations on the classification of commercial kits that can be a win-win for commercial kit vendors and end users.


Asunto(s)
Bioensayo/métodos , Biomarcadores/análisis , Bioensayo/normas , Descubrimiento de Drogas , Humanos , Ligandos , Preparaciones Farmacéuticas/química , Preparaciones Farmacéuticas/metabolismo , Preparaciones Farmacéuticas/normas , Control de Calidad , Juego de Reactivos para Diagnóstico , Estándares de Referencia , Sociedades Farmacéuticas , Encuestas y Cuestionarios
7.
Bioanalysis ; 10(7): 433-444, 2018 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-29701066

RESUMEN

The 11th Global CRO Council Closed Forum was held in Universal City, CA, USA on 3 April 2017. Representatives from international CRO members offering bioanalytical services were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The second CRO-Pharma Scientific Interchange Meeting was held on 7 April 2017, which included Pharma representatives' sharing perspectives on the topics discussed earlier in the week with the CRO members. The issues discussed at the meetings included cumulative stability evaluations, matrix stability evaluations, the 2016 US FDA Immunogenicity Guidance and recent and unexpected FDA Form 483s on immunogenicity assays, the bioanalytical laboratory's role in writing PK sample collection instructions, biosimilars, CRO perspectives on the use of chiral versus achiral methods, hybrid LBA/LCMS assays, applications of fit-for-purpose validation and, at the Global CRO Council Closed Forum only, the status and trend of current regulated bioanalytical practice in China under CFDA's new BMV policy. Conclusions from discussions of these topics at both meetings are included in this report.


Asunto(s)
Bioensayo/métodos , Biomarcadores/análisis , Biosimilares Farmacéuticos/uso terapéutico , China , Humanos , Proyectos de Investigación
8.
Bioanalysis ; 9(22): 1761-1769, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29148829

RESUMEN

AIM: Volumetric absorptive microsampling (VAMS) is a recent technology available for sampling and analyzing low blood volume. The present work describes the utilization of VAMS for the quantitation of naproxen and ritonavir in human blood using a novel bead-based impact-assisted extraction (IAE) procedure. RESULTS: Sampling volume accuracy of the VAMS device was independent of the blood hematocrit (HCT) level, however analyte recovery decreased with increasing HCT when extracted using ultrasonication. In contrast, IAE was unaffected by HCT, resulting in quantitative recovery for all levels evaluated. Precision and accuracy batches, as well as matrix effect evaluation, met acceptance criteria. CONCLUSION: The IAE procedure coupled with VAMS is immune to HCT biases affecting sampling volume and recovery.


Asunto(s)
Recolección de Muestras de Sangre/métodos , Adsorción , Cromatografía Líquida de Alta Presión , Pruebas con Sangre Seca , Hematócrito , Humanos , Naproxeno/sangre , Naproxeno/aislamiento & purificación , Ritonavir/sangre , Ritonavir/aislamiento & purificación , Sonicación , Espectrometría de Masas en Tándem
9.
Bioanalysis ; 9(7): 505-516, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28339299

RESUMEN

The 10th Global CRO Council (GCC) Closed Forum was held in Orlando, FL, USA on 18 April 2016. In attendance were decision makers from international CRO member companies offering bioanalytical services. The objective of this meeting was for GCC members to meet and discuss scientific and regulatory issues specific to bioanalysis. The issues discussed at this closed forum included reporting data from failed method validation runs, GCP for clinical sample bioanalysis, extracted sample stability, biomarker assay validation, processed batch acceptance criteria, electronic laboratory notebooks and data integrity, Health Canada's Notice regarding replicates in matrix stability evaluations, critical reagents and regulatory approaches to counteract fraud. In order to obtain the pharma perspectives on some of these topics, the first joint CRO-Pharma Scientific Interchange Meeting was held on 12 November 2016, in Denver, Colorado, USA. The five topics discussed at this Interchange meeting were reporting data from failed method validation runs, GCP for clinical sample bioanalysis, extracted sample stability, processed batch acceptance criteria and electronic laboratory notebooks and data integrity. The conclusions from the discussions of these topics at both meetings are included in this report.


Asunto(s)
Biomarcadores/análisis , Técnicas de Química Analítica/normas , Recolección de Datos/normas , Guías como Asunto , Preparaciones Farmacéuticas/análisis , Estabilidad de Medicamentos , Regulación Gubernamental , Humanos , Informe de Investigación
10.
Bioanalysis ; 8(6): 487-95, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26916197

RESUMEN

The 9th GCCClosed Forum was held just prior to the 2015 Workshop on Recent Issues in Bioanalysis (WRIB) in Miami, FL, USA on 13 April 2015. In attendance were 58 senior-level participants, from eight countries, representing 38 CRO companies offering bioanalytical services. The objective of this meeting was for CRO bioanalytical representatives to meet and discuss scientific and regulatory issues specific to bioanalysis. The issues selected at this year's closed forum include CAPA, biosimilars, preclinical method validation, endogenous biomarkers, whole blood stability, and ELNs. A summary of the industry's best practices and the conclusions from the discussion of these topics is included in this meeting report.


Asunto(s)
Biomarcadores/análisis , Biosimilares Farmacéuticos/análisis , Evaluación Preclínica de Medicamentos/métodos , Biomarcadores/sangre , Registros Electrónicos de Salud , Laboratorios , Sociedades Médicas , Estudios de Validación como Asunto
SELECCIÓN DE REFERENCIAS