Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Nanomaterials (Basel) ; 14(19)2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39404313

RESUMEN

Thermal lens spectrometry is a high-sensitivity method for measuring the optical and thermal parameters of samples of different nature. To obtain both thermal diffusivity and absorbance-based signal measurements with high accuracy and precision, it is necessary to pay attention to the factors that influence the trueness of photothermal measurements. In this study, the features of liquid objects are studied, and the influence of optical and thermal effects accompanying photothermal phenomena are investigated. Thermal lens analysis of dispersed solutions and systems with photoinduced activity is associated with a large number of side effects, the impact of which on trueness is not always possible to determine. It is necessary to take into account the physicochemical properties and optical and morphological features of the nanophase and components exhibiting photoinduced activity. The results obtained make it possible to reduce systematic and random errors in determining the thermal-diffusivity-based and absorbance-based photothermal signals for liquid objects, and also contribute to a deeper understanding of the physicochemical processes in the sample.

2.
Molecules ; 29(18)2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39339429

RESUMEN

Redox metabolism is an integral part of the glutathione system, encompassing reduced and oxidized glutathione, hydrogen peroxide, and associated enzymes. This core process orchestrates a network of thiol antioxidants like thioredoxins and peroxiredoxins, alongside critical thiol-containing proteins such as mercaptoalbumin. Modifications to thiol-containing proteins, including oxidation and glutathionylation, regulate cellular signaling influencing gene activities in inflammation and carcinogenesis. Analyzing thiol antioxidants, especially glutathione, in biological fluids offers insights into pathological conditions. This review discusses the analytical methods for biothiol determination, mainly in blood plasma. The study includes all key methodological aspects of spectroscopy, chromatography, electrochemistry, and mass spectrometry, highlighting their principles, benefits, limitations, and recent advancements that were not included in previously published reviews. Sample preparation and factors affecting thiol antioxidant measurements are discussed. The review reveals that the choice of analytical procedures should be based on the specific requirements of the research. Spectrophotometric methods are simple and cost-effective but may need more specificity. Chromatographic techniques have excellent separation capabilities but require longer analysis times. Electrochemical methods enable real-time monitoring but have disadvantages such as interference. Mass spectrometry-based approaches have high sensitivity and selectivity but require sophisticated instrumentation. Combining multiple techniques can provide comprehensive information on thiol antioxidant levels in biological fluids, enabling clearer insights into their roles in health and disease. This review covers the time span from 2010 to mid-2024, and the data were obtained from the SciFinder® (ACS), Google Scholar (Google), PubMed®, and ScienceDirect (Scopus) databases through a combination search approach using keywords.


Asunto(s)
Antioxidantes , Compuestos de Sulfhidrilo , Humanos , Antioxidantes/análisis , Antioxidantes/metabolismo , Antioxidantes/química , Compuestos de Sulfhidrilo/análisis , Compuestos de Sulfhidrilo/sangre , Líquidos Corporales/química , Líquidos Corporales/metabolismo , Espectrometría de Masas/métodos , Oxidación-Reducción , Animales , Glutatión/análisis , Glutatión/sangre , Técnicas Electroquímicas/métodos
3.
Nanomaterials (Basel) ; 13(14)2023 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-37513137

RESUMEN

Modern heat-conducting materials require special attention to analyze their thermophysical properties. Compared to classical methods, thermal lens spectrometry (TLS) has advantages due to its high sensitivity to physical and chemical composition. To avoid a systematic error in the analysis of complex systems, it is necessary to realize the limits of the applicability of the method. This study considers the features of thermal-diffusivity measurements by TLS in the stationary state for dispersed systems with absorbances up to 0.05. The limits of applicability of the method in analyzing heterogeneous systems are shown, and a mathematical apparatus is proposed for indicating a systematic error in finding thermal diffusivity that does not exceed 1%. Graphene oxide (GO), which has attractive physicochemical properties, was used as the object of analysis. GO belongs to 2D objects, the study of which requires highly sensitive methods and special attention when discussing the results. The thermophysical properties of aqueous dispersions of graphene oxide in a wide range of concentrations (up to 2 g/L) and lateral sizes (up to 4 µm) were studied by TLS. It has been found that with increasing nanophase concentration, the thermal diffusivity of graphene oxide dispersions passes through a minimum, which can be used in solving thermal insulation problems. It has been established that prolonged laser irradiation of the dispersion leads to a change in thermal diffusivity, which indicates the photochemical reduction of graphene oxide.

4.
Nanomaterials (Basel) ; 13(6)2023 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-36985901

RESUMEN

The growing interest in heat-conducting nanofluids requires highly sensitive methods for analyzing the thermal properties. Thermal lens spectrometry (TLS), despite its advantages over classical methods, does not have a general approach for measuring and interpreting results for dispersed systems. In this paper, for nanofluids of silicon oxide in water in a wide range of concentrations and sizes, the selection of measurement parameters for transient and steady-state thermal lensing is justified, and the interpretation of the results of thermal diffusivity measurements is substantiated. The features of the measurements of thermal diffusivity by TLS under stationary states for dispersed systems are considered. Using this approach, it is possible to detect and distinguish thermal effects with high accuracy. For dispersions of silicon oxide, with increasing concentrations, the thermal diffusivity passes through a minimum threshold. Silicon oxide dispersions can be used both as coolants or as heat-removing liquids by selecting the particle size and concentration.

5.
Int J Mol Sci ; 24(5)2023 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-36901910

RESUMEN

Nanoplatforms applied for the loading of anticancer drugs is a cutting-edge approach for drug delivery to tumors and reduction of toxic effects on healthy cells. In this study, we describe the synthesis and compare the sorption properties of four types of potential doxorubicin-carriers, in which iron oxide nanoparticles (IONs) are functionalized with cationic (polyethylenimine, PEI), anionic (polystyrenesulfonate, PSS), and nonionic (dextran) polymers, as well as with porous carbon. The IONs are thoroughly characterized by X-ray diffraction, IR spectroscopy, high resolution TEM (HRTEM), SEM, magnetic susceptibility, and the zeta-potential measurements in the pH range of 3-10. The degree of doxorubicin loading at pH 7.4, as well as the degree of desorption at pH 5.0, distinctive to cancerous tumor environment, are measured. Particles modified with PEI were shown to exhibit the highest loading capacity, while the greatest release at pH 5 (up to 30%) occurs from the surface of magnetite decorated with PSS. Such a slow release of the drug would imply a prolonged tumor-inhibiting action on the affected tissue or organ. Assessment of the toxicity (using Neuro2A cell line) for PEI- and PSS-modified IONs showed no negative effect. In conclusion, the preliminary evaluation of the effects of IONs coated with PSS and PEI on the rate of blood clotting was carried out. The results obtained can be taken into account when developing new drug delivery platforms.


Asunto(s)
Doxorrubicina , Neoplasias , Humanos , Doxorrubicina/farmacología , Sistemas de Liberación de Medicamentos/métodos , Neoplasias/metabolismo , Nanopartículas Magnéticas de Óxido de Hierro , Iones/uso terapéutico
6.
Nanomaterials (Basel) ; 13(3)2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36770391

RESUMEN

Thermal-lens spectrometry is a sensitive technique for determination of physicochemical properties and thermophysical parameters of various materials including heterogeneous systems and nanoparticles. In this paper, we consider the issues of the correctness (trueness) of measurements of the characteristic time of the thermal-lens effect and, thus, of the thermal diffusivity determined by dual-beam mode-mismatching thermal lensing. As sources of systematic errors, major factors-radiation sources, sample-cell and detector parameters, and general measurement parameters-are considered using several configurations of the thermal-lens setups, and their contributions are quantified or estimated. Furthermore, with aqueous ferroin and Sudan I in ethanol as inert colorants, the effects of the intermolecular distance of the absorbing substance on the correctness of finding the thermophysical parameters are considered. The recommendations for checking the operation of the thermal-lens setup to ensure the maximum accuracy are given. The results obtained help reducing the impact of each investigated factor on the value of systematic error and correctly measure the thermophysical parameters using thermal-lens spectrometry.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...