Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Glob Health ; 12: 04033, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35493777

RESUMEN

Background: Frontline health care workers use World Health Organization Integrated Management of Childhood Illnesses (IMCI) guidelines for child pneumonia care in low-resource settings. IMCI guideline pneumonia diagnostic criterion performs with low specificity, resulting in antibiotic overtreatment. Digital auscultation with automated lung sound analysis may improve the diagnostic performance of IMCI pneumonia guidelines. This systematic review aims to summarize the evidence on detecting adventitious lung sounds by digital auscultation with automated analysis compared to reference physician acoustic analysis for child pneumonia diagnosis. Methods: In this review, articles were searched from MEDLINE, Embase, CINAHL Plus, Web of Science, Global Health, IEEExplore database, Scopus, and the ClinicalTrial.gov databases from the inception of each database to October 27, 2021, and reference lists of selected studies and relevant review articles were searched manually. Studies reporting diagnostic performance of digital auscultation and/or computerized lung sound analysis compared against physicians' acoustic analysis for pneumonia diagnosis in children under the age of 5 were eligible for this systematic review. Retrieved citations were screened and eligible studies were included for extraction. Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. All these steps were independently performed by two authors and disagreements between the reviewers were resolved through discussion with an arbiter. Narrative data synthesis was performed. Results: A total of 3801 citations were screened and 46 full-text articles were assessed. 10 studies met the inclusion criteria. Half of the studies used a publicly available respiratory sound database to evaluate their proposed work. Reported methodologies/approaches and performance metrics for classifying adventitious lung sounds varied widely across the included studies. All included studies except one reported overall diagnostic performance of the digital auscultation/computerised sound analysis to distinguish adventitious lung sounds, irrespective of the disease condition or age of the participants. The reported accuracies for classifying adventitious lung sounds in the included studies varied from 66.3% to 100%. However, it remained unclear to what extent these results would be applicable for classifying adventitious lung sounds in children with pneumonia. Conclusions: This systematic review found very limited evidence on the diagnostic performance of digital auscultation to diagnose pneumonia in children. Well-designed studies and robust reporting are required to evaluate the accuracy of digital auscultation in the paediatric population.


Asunto(s)
Neumonía , Ruidos Respiratorios , Auscultación , Niño , Humanos , Pulmón , Neumonía/diagnóstico , Ruidos Respiratorios/diagnóstico
2.
Vaccine ; 38(42): 6508-6516, 2020 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-32873404

RESUMEN

BACKGROUND: Pneumococcal conjugate vaccine (PCV) effectiveness against radiographic pneumonia in South Asia is unknown. Bangladesh introduced PCV10 in 2015 using a three dose primary series (3 + 0). We sought to measure PCV10 effectiveness for two or more vaccine doses on radiographic pneumonia among vaccine-eligible children in rural Bangladesh. METHODS: We conducted a matched case-control study over two years from 2015 to 2017 using clinic and community controls in three subdistricts of Sylhet, Bangladesh. Cases were vaccine eligible 3-35 month olds at Upazila Health Complex outpatient clinics with World Health Organization-defined radiographic primary endpoint pneumonia (radiographic pneumonia). Clinic controls were matched to cases within a one week time window by age, sex, and clinic and had an illness unlikely to be Streptococcus pneumoniae; community controls were healthy and similarly matched within a one week time window by age and sex, and distance from the clinic. We estimated adjusted vaccine effectiveness (aVE) using conditional logistic regression. RESULTS: We matched 1262 cases with 2707 clinic and 2461 community controls. Overall, aVE using clinic controls was 21.4% (95% confidence interval, -0.2%, 38.4%) for ≥2 PCV10 doses and among 3-11 month olds was 47.3% (10.5%, 69.0%) for three doses. aVE increased with higher numbers of doses in clinic control sets (p = 0.007). In contrast, aVE using community controls was 7.6% (95% confidence interval, -22.2%, 30.0%) for ≥2 doses. We found vaccine introduction in the study area faster and less variable than expected with 75% coverage on average, which reduced power. Information bias may also have affected community controls. CONCLUSIONS: Clinic control analyses show PCV10 prevented radiographic pneumonia in Bangladesh, especially among younger children receiving three doses. While both analyses were underpowered, community control enrollment - compared to clinic controls - was more difficult in a complex, pluralistic healthcare system. Future studies in comparable settings may consider alternative study designs.


Asunto(s)
Infecciones Neumocócicas , Neumonía Neumocócica , Neumonía , Asia , Bangladesh/epidemiología , Estudios de Casos y Controles , Niño , Humanos , Lactante , Vacunas Neumococicas , Neumonía/epidemiología , Neumonía/prevención & control , Neumonía Neumocócica/epidemiología , Neumonía Neumocócica/prevención & control , Vacunas Conjugadas
3.
BMJ Open Respir Res ; 6(1): e000393, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31179000

RESUMEN

Introduction: To evaluate WHO chest radiograph interpretation processes during a pneumococcal vaccine effectiveness study of children aged 3-35 months with suspected pneumonia in Sylhet, Bangladesh. Methods: Eight physicians masked to all data were standardised to WHO methodology and interpreted chest radiographs between 2015 and 2017. Each radiograph was randomly assigned to two primary readers. If the primary readers were discordant for image interpretability or the presence or absence of primary endpoint pneumonia (PEP), then another randomly selected, masked reader adjudicated the image (arbitrator). If the arbitrator disagreed with both primary readers, or concluded no PEP, then a masked expert reader finalised the interpretation. The expert reader also conducted blinded quality control (QC) for 20% of randomly selected images. We evaluated agreement between primary readers and between the expert QC reading and the final panel interpretation using per cent agreement, unadjusted Cohen's kappa, and a prevalence and bias-adjusted kappa. Results: Among 9723 images, the panel classified 21.3% as PEP, 77.6% no PEP and 1.1% uninterpretable. Two primary readers agreed on interpretability for 98% of images (kappa, 0.25; prevalence and bias-adjusted kappa, 0.97). Among interpretable radiographs, primary readers agreed on the presence or absence of PEP in 79% of images (kappa, 0.35; adjusted kappa, 0.57). Expert QC readings agreed with final panel conclusions on the presence or absence of PEP for 92.9% of 1652 interpretable images (kappa, 0.75; adjusted kappa, 0.85). Conclusion: Primary reader performance and QC results suggest the panel effectively applied the WHO chest radiograph criteria for pneumonia.


Asunto(s)
Vacunas Neumococicas , Neumonía Neumocócica/diagnóstico por imagen , Neumonía Neumocócica/prevención & control , Radiografía Torácica , Bangladesh , Preescolar , Estudios de Cohortes , Humanos , Lactante , Variaciones Dependientes del Observador , Distribución Aleatoria
4.
Gates Open Res ; 2: 21, 2018 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-29984359

RESUMEN

The study examines the impact of the introduction of 10-valent Pneumococcal Conjugate Vaccine (PCV10) into Bangladesh's national vaccine program. PCV10 is administered to children under 1 year-old; the scheduled ages of administration are at 6, 10, and 18 weeks. The study is conducted in ~770,000 population containing ~90,000 <5 children in Sylhet, Bangladesh and has five objectives: 1) To collect data on community-based pre-PCV incidence rates of invasive pneumococcal diseases (IPD) in 0-59 month-old children in Sylhet, Bangladesh; 2) To evaluate the effectiveness of PCV10 introduction on Vaccine Type (VT) IPD in 3-59 month-old children using an incident case-control study design. Secondary aims include measuring the effects of PCV10 introduction on all IPD in 3-59 month-old children using case-control study design, and quantifying the emergence of Non Vaccine Type IPD; 3) To evaluate the effectiveness of PCV10 introduction on chest radiograph-confirmed pneumonia in children 3-35 months old using incident case-control study design. We will estimate the incidence trend of clinical and radiologically-confirmed pneumonia in 3-35 month-old children in the study area before and after introduction of PCV10; 4) To determine the feasibility and utility of lung ultrasound for the diagnosis of pediatric pneumonia in a large sample of children in a resource-limited setting. We will also evaluate the effectiveness of PCV10 introduction on ultrasound-confirmed pneumonia in 3-35 month-old children using an incident case-control design and to examine the incidence trend of ultrasound-confirmed pneumonia in 3-35 month-old children in the study area before and after PCV10 introduction; and 5) To determine the direct and indirect effects of vaccination status on nasopharyngeal colonization on VT pneumococci among children with pneumonia .  This paper presents the methodology. The study will allow us to conduct a comprehensive and robust assessment of the impact of national introduction of PCV10 on pneumococcal disease in Bangladesh.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...