Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
2.
J Am Heart Assoc ; 11(18): e027119, 2022 09 20.
Artículo en Inglés | MEDLINE | ID: mdl-36047732

RESUMEN

Background Many hospitalized patients are not administered prescribed doses of pharmacologic venous thromboembolism prophylaxis. Methods and Results In this cluster-randomized controlled trial, all adult non-intensive care units (10 medical, 6 surgical) in 1 academic hospital were randomized to either a real-time, electronic alert-triggered, patient-centered education bundle intervention or nurse feedback intervention to evaluate their effectiveness for reducing nonadministration of venous thromboembolism prophylaxis. Primary outcome was the proportion of nonadministered doses of prescribed pharmacologic prophylaxis. Secondary outcomes were proportions of nonadministered doses stratified by nonadministration reasons (patient refusal, other). To test our primary hypothesis that both interventions would reduce nonadministration, we compared outcomes pre- versus postintervention within each cohort. Secondary hypotheses were tested comparing the effectiveness between cohorts. Of 11 098 patient visits, overall dose nonadministration declined significantly after the interventions (13.4% versus 9.2%; odds ratio [OR], 0.64 [95% CI, 0.57-0.71]). Nonadministration decreased significantly (P<0.001) in both arms: patient-centered education bundle, 12.2% versus 7.4% (OR, 0.56 [95% CI, 0.48-0.66]), and nurse feedback, 14.7% versus 11.2% (OR, 0.72 [95% CI, 0.62-0.84]). Patient refusal decreased significantly in both arms: patient-centered education bundle, 7.3% versus 3.7% (OR, 0.46 [95% CI, 0.37-0.58]), and nurse feedback, 9.5% versus 7.1% (OR, 0.71 [95% CI, 0.59-0.86]). No differential effect occurred on medical versus surgical units. The patient-centered education bundle was significantly more effective in reducing all nonadministered (P=0.03) and refused doses (P=0.003) compared with nurse feedback (OR, 1.28 [95% CI, 1.0-1.61]; P=0.03 for interaction). Conclusions Information technology strategies like the alert-triggered, targeted patient-centered education bundle, and nurse-focused audit and feedback can improve venous thromboembolism prophylaxis administration. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT03367364.


Asunto(s)
Tromboembolia Venosa , Adulto , Anticoagulantes/efectos adversos , Retroalimentación , Hospitalización , Humanos , Educación del Paciente como Asunto , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/tratamiento farmacológico , Tromboembolia Venosa/prevención & control
5.
Int Urogynecol J ; 30(8): 1329-1336, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30191250

RESUMEN

INTRODUCTION AND HYPOTHESIS: The Miya Model ™ (Miyazaki Enterprises, Winston-Salem, NC, USA) was designed as a realistic vaginal surgery simulation model. Our aim was to describe this model and present pilot data on validity and reliability of the model as an assessment tool of vaginal hysterectomy skills. METHODS: We video recorded ten obstetrics and gynecology residents (novice group) and ten practicing gynecologists (expert group) performing vaginal hysterectomy using the Miya model. Blood loss and time taken to complete the procedure were documented. Participants evaluated the model using a postsimulation survey. In addition, two experienced gynecologic surgeons independently evaluated video recordings of each participant's performance using two previously validated global rating scales: Reznick's Objective Structured Assessment of Technical Skill (OSATS) and Vaginal Surgical Skills Index (VSSI). RESULTS: Most participants (80% of novice and 100% of expert group) rated the model as effective or highly effective for vaginal hysterectomy training and assessment. Median time to procedure completion was significantly higher in the novice group, whereas median estimated blood loss was no different between groups. No significant differences were observed in the composite median OSATS or VSSI scores between groups. The interrater reliability indices for subscales and composite scores of the OSATS and VSSI were high and ranged from 0.79 to 0.90 and 0.77 to 0.93, respectively. CONCLUSIONS: With further study, the Miya Model may be a useful tool for teaching and assessing vaginal surgical skills.


Asunto(s)
Ginecología/educación , Histerectomía Vaginal/educación , Modelos Educacionales , Obstetricia/educación , Entrenamiento Simulado , Adulto , Competencia Clínica , Femenino , Humanos , Persona de Mediana Edad , Proyectos Piloto , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...