Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Appl Radiat Isot ; 181: 110093, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34995841

RESUMEN

Laser resonance ionization at the RISIKO 30 kV mass separator has been used to produce isotopically and isobarically pure and well quantified 222Rn emanation standards. Based upon laser-spectroscopic preparation studies, ion implantation into aluminum and tungsten targets has been carried out, providing overall implantation efficiencies of 40% up to 60%. The absolute implanted activity of 226Ra was determined by the technique of defined solid-angle α-particle spectrometry, where excellent energy resolution was observed. The 222Rn emanation coefficient of the produced targets was studied using α-particle and γ-ray spectrometry, and yielded results between 0.23 and 0.34, with relative uncertainty on the order of 1%. No dependence exceeding a 1% change of the emanation on humidity could be identified in the range of 15 %rH to 75 %rH, whereas there were hints of a slight correlation between the emanation and temperature. Additionally, and as expected, the emanation coefficient was found to be dependent on the target material as well as the implanted dose.

2.
Phys Rev Lett ; 125(7): 073001, 2020 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-32857542

RESUMEN

Two lowest-energy odd-parity atomic levels of actinium, 7s^{2}7p^{2}P_{1/2}^{o}, 7s^{2}7p^{2}P_{3/2}^{o}, were observed via two-step resonant laser-ionization spectroscopy and their respective energies were measured to be 7477.36(4) and 12 276.59(2) cm^{-1}. The lifetimes of these states were determined as 668(11) and 255(7) ns, respectively. In addition, we observed the effect of the hyperfine structure on the line for the transition to ^{2}P_{3/2}^{o}. These properties were calculated using a hybrid approach that combines configuration interaction and coupled-cluster methods, in good agreement with the experiment. The data are of relevance for understanding the complex atomic spectra of actinides and for developing efficient laser cooling and ionization schemes for actinium, with possible applications for high-purity medical-isotope production and future fundamental physics experiments.

3.
Rev Sci Instrum ; 90(5): 053304, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31153223

RESUMEN

To measure the mass of the electron neutrino, the "Electron Capture in Holmium-163" (ECHo) collaboration aims at calorimetrically measuring the spectrum following electron capture in 163Ho. The success of the ECHo experiment depends critically on the radiochemical purity of the 163Ho sample, which is ion-implanted into the calorimeters. For this, a 30 kV high transmission magnetic mass separator equipped with a resonance ionization laser ion source is used. To meet the ECHo requirements, the ion source unit was optimized with respect to its thermal characteristics and material composition by means of the finite element method thermal-electric calculations and chemical equilibrium simulation using the Gibbs energy minimization method. The new setup provides an improved selectivity of laser ionization vs interfering surface ionization of 2700(500) and an overall efficiency of 41(5)% for the ion-implantation process.

SELECCIÓN DE REFERENCIAS